Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "model biomechaniczny" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Research of cyclist’s spine dynamical model
Autorzy:
Griskevicius, J.
Linkel, A.
Pauk, J
Powiązania:
https://bibliotekanauki.pl/articles/306676.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
accelerometer
bicycling
biomechanical model
dynamics
spine
akcelerometr
rower
model biomechaniczny
dynamika
kręgosłup
Opis:
The purpose of the paper is to present a dynamic model of bicyclist’s lumbar spine for the evaluation of linear and angular variation of intervertebral distance in sagittal plane. Ten degrees of freedom biomechanical model of the spine was solved numerically. Larger loads acting on a cyclist spine occur mostly while sitting in a sport position in comparison with recreation or middle sitting. The load on lumbar spine region is influenced by cycle’s tire pressure, road bumps and wheeling speed. The biggest linear and angular displacements were found between L4–L5 vertebras. The biggest load protractile spine muscle experiences in the sport sitting position. Maximum vertebrae rotation and linear variation values in wheeling regime with 1.5 Bar tyres pressure and at a speed of 10 km/h are 0.46° and 0.46 mm. Maximum vertebrae rotation and linear variation values for a 23 year old, 1.74 m high and 73 kg of mass (bicycle mass ~ 7 kg) man in wheeling regime with 3.5 Bar tyres pressure and at a speed of 30 km/h are 3.9° and 1.23 mm. The biggest variation of rotation in sagittal plane between two nearest lumbar spines is about 1°. Because of this displacement the frontal part of last mentioned disc is compressed with 530 N more and dorsal disc part as much less.
Źródło:
Acta of Bioengineering and Biomechanics; 2014, 16, 1; 37-44
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Applanation pressure function in Goldmann tonometry and its correction
Autorzy:
Śródka, W.
Powiązania:
https://bibliotekanauki.pl/articles/306833.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
eyeball
biomechanical model
tonometry
IOP
correction factors
gałka oczna
tonometria
korekcja
model biomechaniczny
Opis:
So far applanation tonometry has not worked out any theoretical basis for correcting the result of intraocular pressure measurement carried out on a cornea with noncalibration dimensions by means of the Goldmann tonometer. All the tables of instrument reading corrections for cornea thickness or cornea curvature radius are based exclusively on measurements. This paper represents an attempt at creating a mechanical description of corneal apex deformation in Goldmann applanation tonometry. The functional dependence between intraocular pressure and the pressure exerted on the corneal apex by the tonometer was determined from a biomechanical model. Numerical GAT simulations, in which this function was also interrelated with the cornea’s curvature radius and thickness were run and a constitutive equation for applanation tonometry, i.e. a full analytical description of intraocular pressure as a function of the above variables, was derived on this basis. The correction factors were defined and an algorithm for correcting the measured pressure was formulated. The presented formalism puts the results of experimental tonometry in new light. Analytical correction factors need not to come exclusively from measurements. A geometric interdependence between them and their dependence on pressure have been revealed. The theoretical description of applanation tonometry contained in the constitutive equation consists of a pressure function developed for a cornea with calibration dimensions and a coefficient correcting this calibration function, dependent exclusively on the cornea’s actual thickness and curvature radius. The calibration function is a generalization of the Imbert–Fick law.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 3; 97-106
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Budowa i animacja realistycznego modelu 3D mięśnia dwugłowego ramienia
Construction and animation of realistic biceps 3D model
Autorzy:
Poleszak, S.
Kopniak, P.
Powiązania:
https://bibliotekanauki.pl/articles/98272.pdf
Data publikacji:
2016
Wydawca:
Politechnika Lubelska. Instytut Informatyki
Tematy:
modelowanie 3D
animacja komputerowa
model biomechaniczny
analiza ruchu
3D modeling
computer animation
biomechanical model
motion analysis
Opis:
Artykuł dotyczy opracowania sposobu budowy modelu trójwymiarowego mięśnia dwugłowego ramienia człowieka tak aby mięsień wyglądał i zachowywał się realistycznie podczas animacji. Dane do animacji są pozyskiwane przez systemy akwizycji ruchu - Motion Capture. Do zaprojektowania modelu bryły wykorzystano oprogramowanie Blender v.2.76. Na jego podstawie możliwe jest przeprowadzanie badań dotyczących analizy ruchu ramienia z wykorzystaniem danych zapisanych w plikach BVH.
The article concerns the development of three-dimensional model of how to build biceps human with the muscle looked and behaved realistically when animation. Data for animation are obtained by acquisition systems Motion - Motion Capture. Blender software v.2.76 was used to design a solid model. On this basis it is possible to carry out research on the analysis of the movement of the arm using data stored in BVH files.
Źródło:
Journal of Computer Sciences Institute; 2016, 2; 93-97
2544-0764
Pojawia się w:
Journal of Computer Sciences Institute
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies