Tytuł:
Application of Model-Based Tests for Analysing the Consequences of Mine Fires
Autorzy:
Tutak, M.
Powiązania:
https://bibliotekanauki.pl/articles/2064980.pdf
Data publikacji:
2018
Wydawca:
STE GROUP
Tematy:
mine fires
methane combustion
numerical analysis
Opis:
One of the most common and most dangerous hazards in underground coal mines is fire hazard. Mine fires can be exogenous or endogenous in nature. In the case of the former, a particular hazard is posed by methane fires that occur in dog headings and longwalls. Endogenous and exogenous fires are large hazard for working crew in mining headings and cause economics losses for mining plants. Mine fires result in emission of harmful chemical products and have a crucial impact on the physical parameters of the airflow. The subject of the article concerns the analysis of the consequences of methane fires in dog headings. These consequences were identified by means of model-based tests. For this purpose, a model was developed and boundary conditions were adopted to reflect the actual layout of the headings and the condition of the atmosphere in the area under analysis. The objective of the test was to determine the effects of methane fires on the chemical composition of the atmosphere and the physical parameters of the gas mixture generated in the process. The results obtained clearly indicate that fires have a significant impact on the above-mentioned values. The paper presents the distributions for the physical parameters of the resulting gas mixture and the concentration of fire gases. Moreover, it shows the distributions of temperature and oxygen concentration levels in the headings under analysis. The methodology developed for the application of model-based tests to analyse fire events in mine headings represents a new approach to the problem of investigating the consequences of such fires. It is also suitable for variant analyses of the processes related to the ventilation of underground mine workings as well as for analyses of emergency states. Model-based tests should support the assessment of the methane hazard levels and, subsequently, lead to an improvement of work safety in mines.
Źródło:
Multidisciplinary Aspects of Production Engineering; 2018, 1, 1; 767--774
2545-2827
Pojawia się w:
Multidisciplinary Aspects of Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Danger zone of spontaneous combustion in the gob with lower entry retained along the gob
Strefa zagrożenia spontanicznym spalaniem w zrobach z podścianowym chodnikiem utrzymywanym wzdłuż zrobów
Autorzy:
Shu-jie, Y.
Powiązania:
https://bibliotekanauki.pl/articles/164957.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Górnictwa
Tematy:
pożary podziemne
spontaniczne spalanie
pożary w zrobach
mine fires
spontaneous combustion
fires in gob
Opis:
In recent years, with the increase in mining depth and the change of mining methods (such as: mining with entry retained along the gob, using Y- type ventilation system), the risk of spontaneous combustion has increased, threatening the safety in coal mine. In order to determine the danger zone of spontaneous combustion in the gob, so as to provide the basis for fire prevention, temperature probes and gas exhausting pipes were embedded in the gob along the upper entry and behind supports. Temperature and oxygen concentration at different sites were obtained. Based on the rate of temperature rise and oxygen concentration changes, the risk zone of spontaneous combustion and the features of the “three zones” in the gob were obtained. The heat dissipation zone is very narrow, the widest position of the heat dissipation zone and the oxidation zone are in the triangle strip formed by hydraulic supports and the wall of gangue bags along the lower entry retained along the gob.
W ostatnich latach, wraz ze wzrostem głębokości oraz zmianą sposobów wybierania pokładów węgla (np. wybieranie z chodnikiem przyścianowym utrzymywanym wzdłuż zrobów, używanie systemu wentylacji ścianowej typu Y), zwiększone ryzyko samozapłonu zagraża bezpieczeństwu w kopalniach węgla kamiennego. W celu określenia strefy zagrożenia spontanicznym spalaniem w zrobach i zapewnieniu podstaw zapobiegania pożarom, osadzono sondy temperatury i czujniki tlenu w zrobach wzdłuż chodnika nadścianowego, za obudową zmechanizowaną. Następnie przebadano temperaturę oraz stężenie tlenu w różnych miejscach pomiaru. Na podstawie tempa wzrostu temperatury i zmian stężenia tlenu wyznaczono strefę zagrożenia samozapaleniem. W ten sposób wyznaczono «trzy strefy» w zrobach. Strefę rozpraszania ciepła, która jest bardzo wąska, szersze są strefy rozpraszania ciepła i utleniania, które znajdują się w trójkącie utworzonym przez obudowy hydrauliczne i ścianę.
Źródło:
Przegląd Górniczy; 2017, 73, 9; 1-5
0033-216X
Pojawia się w:
Przegląd Górniczy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zabezpieczenie prądów powietrza sprowadzanych na upad w kopalniach węgla kamiennego
Protection of airways with descending air currents in hard coal mines
Autorzy:
Szlązak, N.
Obracaj, D.
Powiązania:
https://bibliotekanauki.pl/articles/164218.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Górnictwa
Tematy:
wentylacja kopalń
pożary podziemne
schodzące prądy powietrza
mine ventilation
mine fires
descending air currents
Opis:
W ostatnich latach powiększa się liczba kopalń prowadzących eksploatację poniżej poziomu udostępnienia. Wiąże się to z istnieniem wyrobisk, w których prądy powietrza sprowadzane są na upad. W artykule omówiono możliwości zaburzeń przepływu powietrza podczas powstania pożaru w takich wyrobiskach. Wskazano na czynniki, które powodują odwracanie się prądów powietrza ze szczególnym uwzględnieniem lokalizacji wyrobiska w strukturze sieci wentylacyjnej. Na podstawie przykładu ściany eksploatacyjnej poniżej poziomu udostępnienia wykazano trudności w odwróceniu prądu powietrza sprowadzanego na upad. Ustosunkowano się do zabezpieczeń prądów powietrza sprowadzanych na upad w obowiązujących przepisach górniczych. Zaakcentowano istotną rolę monitoringu parametrów powietrza i zabezpieczeń przeciwpożarowych w wyrobiskach ze schodzącymi prądami powietrza.
The number of mines operating below the development level has increased in recent years. This is related to the existence of airways with descending air currents. Disturbances in airflow, while a fire breaks out in such airways, are discussed in the article. The factors that cause the reversion of airflows, with particular regard to the location of the airway in the structure of the ventilation network, were presented. On the basis of the example of the longwall panel below the development level, difficulties in reversing the descensional airflow are shown. The expression of authors’ standpoint with respect to the protection against the reversion of descending airways according to mining law and regulations is presented. The important role of monitoring of air parameters and fire protection in airways with descending air currents has been emphasized.
Źródło:
Przegląd Górniczy; 2017, 73, 6; 38-43
0033-216X
Pojawia się w:
Przegląd Górniczy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of spontaneous combustion "three zones" in goaf of no. 713 fully mechanized longwall of Qinan Coal Mine
Wyznaczenie "trzech stref" pożaru endogenicznego w zrobach ściany zmechanizowanej nr 713 w kopalni węgla kamiennego w Qinan
Autorzy:
Dai, G. L.
Zhang, S. C.
Tang, M. G.
Powiązania:
https://bibliotekanauki.pl/articles/348813.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
bezpieczeństwo w kopalni
pożary w kopalniach
pożary w zrobach
safety in coal mines
mine fires
fires in goaf
Opis:
In goaf of No.713 fully mechanized longwall of Qinan Coal Mine spontaneous combustion parameters test system was installed and different gases concentration and temperature distribution in the goaf were obtained. By use of specialized computational fluid dynamics software FLUENT leakage flow field distribution in the goaf was simulated. Finally, on the basis of oxygen concentration and temperature trends and air leakage speed distribution in the goaf, the "three zones" in the goaf was determined. The results showed that distribution of "three zones" in the goaf is not symmetrical. Along the side of intake in the goaf heat dissipation zone width is 0-30 m from the working face, oxidation zone width is 30-90 m. Along the side of return airway in the goaf heat dissipation zone width is 0-20 m from the working face, oxidation zone width is 20-80 m. The results provide a guidance for developing scientific and effective fire prevention and control measures in goaf.
W zrobach ściany zmechanizowanej nr 713 kopalni węgla kamiennego w Qinan zainstalowano system badania parametrów pożaru endogenicznego, za pomocą którego uzyskano parametry różnych stężeń gazów i zakresu temperatur występujących w zrobach. Poprzez wykorzystanie specjalistycznego oprogramowania FLUENT (obliczeniowa mechanika płynów) wykonano symulację pola przepływu gazów. Na podstawie wartości stężenia tlenu oraz wskazań temperatury i prędkości przepływu powietrza w zrobach wyznaczono "trzy strefy" spalania. Wyniki pokazują, że rozkład "trzech stref' w zrobach jest niesymetryczny. Szerokość wzdłuż wlotu powietrza w strefie rozpraszania ciepła w zrobach wynosi 0-K30 m od strony wyrobiska ścianowego, szerokość obszaru utleniania to 30-90 m. Szerokość wzdłuż kanału powrotnego powietrza w strefie rozpraszania ciepła w zwalisku wynosi 0-20 m od strony roboczej, szerokość obszaru utleniania to 20-80 m. Wyniki stanowią podstawy do opracowania skutecznego i opartego na wiedzy naukowej systemu ochrony przeciwpożarowej i zabezpieczeń w zrobach.
Źródło:
AGH Journal of Mining and Geoengineering; 2012, 36, 3; 99-113
1732-6702
Pojawia się w:
AGH Journal of Mining and Geoengineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation of flow of fire gases in a ventilation network of a mine with a application of mathematical models of a different complexity implemented in the VentGraph software
Symulacja przepływu gazów pożarowych w sieci wyrobisk kopalni za pomocą programu VentGraph dla modeli matematycznych o zróżnicowanym stopniu uproszczenia
Autorzy:
Dziurzyński, W.
Krawczyk, J.
Krach, A.
Pałka, T.
Powiązania:
https://bibliotekanauki.pl/articles/348815.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
wentylacja kopalń
pożary podziemne
przepływ nieustalony
wilgotne powietrze
mine ventilation
mine fires
unsteady flow
humid air
numerical simulations
Opis:
VENTGRAPH computer programmes, enable the forecasting of ventilation processes under normal conditions and in emergency situations, such as a fire. The state of the flow of air in a network of headings may be forecasted by numerical simulations using a set of mathematical models, which are constructed at various degrees of simplification. Variants considering dry air only and more complex mathematical model, which takes into consideration the flow of the mix of humid air and gases were compared. Both variants consider relevant fire models and exchange of heat along the flow routes of fire gases and buoyancy effects. This models are the result of the optimal selection of individual components, performed in such a way as to conduct a sufficiently reliable simulation of the phenomena as set forward herein in as short a time as possible. Paper contains a study that is devoted to an instance of forecasting the process of ventilation that are caused by an open subsurface fire in the operational headings of mines that are ventilated by upward air current. This has made it possible to execute a qualitative analysis of the changes in the flow rate of the mix of air and fire gases, and also to verify the possibility of reversing the air currents that ventilate the longwalls. The results obtained have been presented in the form of time graphs of changes in the observed parameters.
System programów komputerowych VENTGRAPH jest przeznaczony do prognozowania procesów przewietrzania w warunkach normalnych oraz w stanie awaryjnym jakim jest pożar i charakteryzuje się szerokimi możliwościami obliczeniowymi i łatwością obsługi programu jak i interpretacji wyników jego obliczeń. Stan przepływu powietrza w sieci wyrobisk można przewidywać przy pomocy badań symulacyjnych w oparciu o złożone modele matematyczne konstruowane w różnym stopniu uproszczenia. W artykule porównano warianty opisujące przepływ suchego lub wilgotnego powierza. Oba warianty uwzględniają odpowiednie modele ogniska pożaru a także przepływ mieszaniny powietrza i gazów z równoczesną wymianą ciepła wzdłuż dróg przepływu gazów pożarowych a także wpływ depresji pożaru. Modele te są efektem optymalnego doboru poszczególnych składników, dokonanego tak aby w możliwie krótkim czasie prowadzić dostatecznie wierną symulację rozpatrywanych zjawisk. Przedstawiono przykład prognozy procesu przewietrzania wywołanego otwartym pożarem podziemnym w wyrobiskach czynnych kopalń przewietrzanych prądem wznoszącym. Pozwoli to na dokonanie analizy jakościowej zmian wydatku przepływu mieszaniny powietrza i gazów pożarowych oraz sprawdzenia możliwości odwrócenia prądów powietrza, którymi przewietrzane są ściany. Uzyskane wyniki przedstawiono w postaci wykresów czasowych zmian obserwowanych parametrów.
Źródło:
AGH Journal of Mining and Geoengineering; 2012, 36, 3; 115-126
1732-6702
Pojawia się w:
AGH Journal of Mining and Geoengineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ składu chemicznego suchego powietrza kopalnianego na dodatkowe zabezpieczenie nadpoziomowych robót wydobywczych o schodzącym przewietrzaniu przed bezpośrednim zadymieniem w czasie pożarów w schodzącym prądzie niezależnym
The influence of dry mine air chemical composition on additional protection of active upper level mining works with descending ventilation against fogging during fires in the descending independent air current
Autorzy:
Bystroń, H.
Powiązania:
https://bibliotekanauki.pl/articles/187013.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
pożary kopalniane
wentylacja kopalń
fires
mine ventilation
Opis:
Dla systemu wentylacji kopalni głębokiej i adekwatnych do niego dwu zmodyfikowanych systemów wentylacji [3] opracowano pola procentowych udziałów składników chemicznych suchego powietrza kopalnianego. Wychodząc z tych pól i pól temperatury (termometru suchego) tego powietrza w wymienionych systemach wentylacji, opracowano pola temperatury wirtualnej tegoż powietrza w tych systemach wentylacji. Tak samo jak w pracy [3] badaniem objęto trzy struktury topologiczne wymienionych systemów wentylacji - przedstawione za pomocą zamkniętych dwuoczkowych schematów kanonicznych. Każdy z nich złożony jest z trzech bocznic wypadkowych: bocznica wypadkowa b- z grupą robót wydobywczych (II), bocznica wypadkowa w - z grupą robót wydobywczych (I) z formującym się pożarem węgla oraz bocznica wypadkowa z - z wentylatorem głównym. Przepływy turbulentne powietrza kopalnianego traktowano jako jednowymiarowe ustalone z wymianą masy i ciepła, powietrze kopalniane - jako mieszaninę pary wodnej, kropelek ciekłej wody i czystego powietrza suchego (czynnik termodynamiczny), którego skład chemiczny nie zależy od miejsca. Dla każdej z wymienionych struktur topologicznych metodą termodynamiczną wyprowadzono warunek zachowania pierwotnego (prostego) kierunku prądu w bocznicach wypadkowych b i w oraz ich dotyczące stopnie bezpieczeństwa. Na dyskusji uzyskanych wyników oparto wnioski.
For a deep mine ventilation system and two adequate modified ventilation systems [3] it was elaborated the fields of percentage share of chemical components of dry mine air. These fields, along with temperature fields (dry bulb temperature) of this air were the basis to work out virtual temperature fields of this air in these ventilation systems. Similarly to [3], the tests covered three topological structures of the mentioned ventilation systems - presented by means of two-mesh closed canonical schemes. Each of them is composed of three resultant splits: the b split - with a group of mining works (II), the w split - with a group of mining works (I) with a forming coal fire, and the z split - with the main fan. Turbulent flows of mine air were treated as one-dimensional and steady with mass and heat exchange, and mine air - as a mixture of water vapour, liquid water droplets and pure dry air (pure substance) whose chemical composition does not depend on the location. For each of the mentioned topological structures the author introduced the condition of preserving original (straight) air direction in the b and w splits along with their safety degrees. The conclusions were based on the results obtained.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2011, R. 49, nr 2, 2; 5-17
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the average fire gas temperature in a mine drift with multiple fires
Autorzy:
Hansen, R.
Powiązania:
https://bibliotekanauki.pl/articles/91997.pdf
Data publikacji:
2018
Wydawca:
Główny Instytut Górnictwa
Tematy:
multiple fires
mine drifts
average fire gas temperature
pożary wielokrotne
chodniki kopalniane
średnia temperatura gazu pożarowego
Opis:
The average fire gas temperature of multiple fires in a mine drift with longitudinal ventilation is investigated. The output of a quasi-steady model is investigated and compared with experimental results from model scale fire experiments. During the analysis it was found that the calculated average fire gas temperature of the model correlates quite well with the measured temperature, except for the period when the fire closest to the measuring point reached a peak of heat release rate. This poor correlation is likely due to flame impingement as the distance to the nearest fire decreases. Uncertainty of the calculations is caused by the fire gas temperature at the site of each individual fire and further studies into the fire growth rate and maximum heat release rates of multiple fires are recommended in order to remedy this uncertainty. When calculating the average fire gas temperature, a key parameter is determined with respect to the smoke spread in a mine drift as well as the risk of fire spread.
Źródło:
Journal of Sustainable Mining; 2018, 17, 4; 226-238
2300-1364
2300-3960
Pojawia się w:
Journal of Sustainable Mining
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation and optimization of evacuation routes in case of fire in underground mines
Autorzy:
Adjiski, V.
Mirakovski, D.
Despodov, Z.
Mijalkovski, S.
Powiązania:
https://bibliotekanauki.pl/articles/91938.pdf
Data publikacji:
2015
Wydawca:
Główny Instytut Górnictwa
Tematy:
underground mine
fire scenario
modeling fires
optimization
simulation
evacuation plan
kopalnia podziemna
scenariusz pożaru
modelowanie pożaru
optymalizacja
symulacja
plan ewakuacji
Opis:
Risks of fire occurrence in underground mines are known for a long time. Evacuation and rescue plans allow to each underground mine to respond and establish control in case of emergency. The primary goal of this paper is to determine the optimal system for evacuation in case of fire in underground mines and through a process of computer simulation to be presented to all workers that are affected by this issue. In this study is developed a system that allows by using available software to work out the complete evacuation plans that include analysis of fire scenarios and optimal routes for evacuation. With development of database of fire scenarios, it is possible to plan routes for evacuation in all situations. This presented methodology can serve to make effective system for evacuation and rescue in case of fire and to help save lives and protect the financial investment in the mine. This methodology represents the most economical option of making an effective system for evacuation and also can serve as an idea of making a software package that includes all the steps of making a system for evacuation and rescue in case of fire in underground mines. This presented model will have increased accuracy compared to other models presented so far, because of the prepared 3D model of the underground mine which includes the actual dimensions of the mine along with its associated elements from which the fire dynamics and system for evacuation depends.
Źródło:
Journal of Sustainable Mining; 2015, 14, 3; 133-143
2300-1364
2300-3960
Pojawia się w:
Journal of Sustainable Mining
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies