Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "mikrotomografia" wg kryterium: Temat


Tytuł:
Modeling of X-ray propagation in bone microstructure
Autorzy:
Binkowski, M.
Król, Z.
Wróbel, Z.
Zeilhofer, H.-F.
Powiązania:
https://bibliotekanauki.pl/articles/333863.pdf
Data publikacji:
2005
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
mikrotomografia
mikrostruktury kości
tłumienie promieniowania rentgenowskiego
wizualizacja
tomografia komputerowa
erozja
microtomography
X-ray propagation
bone microstructure
attenuation of X-ray radiation
visualization
computed tomography
erosion
Opis:
This paper presents some results concerning the analysis of X-ray propagation through biological structures. We introduce a physical model of the phenomenon and a numerical method based on this model for simulation of X-ray radiation propagation. The proposed method enables generation of radiological projections like those in the computed tomography or microtomography. We have focused our attention on the attenuation of X-ray radiation in bone tissue. Our computational model enables simulation of radiation propagation in the virtual specimen. The virtual bone microstructures used in our experiments are derived from the microtomography datasets of real bone specimens. The main advantage of our approach is that we can change the microstructure of the virtual sample in many ways by using the image processing methods. Results presented in this paper contain simulations of X-ray propagation for modified and unmodified trabecular microstructures as well as the visualization of the radiation intensity distribution for the simulated cases. With this new simulation technique, it is possible for example to analyze the propagation of X-ray radiation for different pathologic types of bone microstructure (e.g. virtually generated osteoporosis).
Źródło:
Journal of Medical Informatics & Technologies; 2005, 9; 75-82
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heterogeneous pores distribution in polyurethane expanding foams detected via X-ray computed microtomography
Niejednorodność rozkładu porów w ekspandujących piankach poliuretanowych obserwowana metodą mikrotomografii komputerowej
Autorzy:
Blażejczyk, A.
Wierzbicka, P.
Powiązania:
https://bibliotekanauki.pl/articles/947301.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
rentgenowska mikrotomografia komputerowa
obrazowanie pianki
pianki poliuretanowe
pory
więzadła
X-ray computed microtomography
foam imaging
polyurethane foams
pores
struts
Opis:
X-ray computed microtomography (μ-CT) was applied as a noninvasive three-dimensional (3D) imaging technique for characterization of solid cellular material microstructure. Comparison between morphologies of two versions (summer and winter) of polyurethane (PUR) expanding foam (commercially available as the one-component 1K hand-held foams, applicable in building sector) was done. The evident relationship between processing and microstructure was explained. The most significant morphometric parameters were obtained via quantitative and qualitative 3D microstructure μ-CT analysis. The analysis embraced computing: dimensions of the selected structural elements (struts or pores), the average surface areas and volumes either of solid matrix or pores (open and close), as well as porosity assessment. The pores diameters (structure separation) statistical distributions were found and resulted as heterogeneous for both PUR versions, as revealed via proposed Gaussian μ-CT data analysis (“double Gauss” model).
Do charakterystyki mikrostruktury materiału komórkowego zastosowano rentgenowską mikrotomografię komputerową (µ-CT) – nieinwazyjną technikę obrazowania trójwymiarowego (3D). Porównano morfologie dwóch wersji (letniej i zimowej)pianki poliuretanowej (PUR), dostępnej w handlu w postaci jednoskładnikowej ekspandującej pianki typu 1K do zastosowań w budownictwie. Omówiono zaobserwowaną zależność między technologią przetwarzania a mikrostrukturą pianki. Na podstawie ilościowej i jakościowej mikrotomograficznej analizy trójwymiarowej mikrostruktury, obejmującej obliczenia wymiarów podstawowych elementów struktury (więzadeł i porów), a także powierzchni i objętości matrycy stałej i porów (otwartych i zamkniętych), wyznaczono najistotniejsze parametry morfometryczne. Dokonano też oceny porowatości pianki. Rozkłady średnic porów (structure separation) uzyskane w wyniku zaproponowanej gaussowskiej analizy danych mikrotomograficznych (double Gauss model) okazały się niejednorodne w wypadku obu wersji pianek PUR.
Źródło:
Polimery; 2018, 63, 10; 685-693
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie mikrotomografii komputerowej (μCT) w diagnostyce jakości zabezpieczenia otworów wiertniczych przed migracją gazu
Computer microtomography (μCT) application in wells anti gas migration sealing quality inspections
Autorzy:
Bolewski, Ł.
Karpiński, B.
Kmieć, M.
Szkodo, M.
Powiązania:
https://bibliotekanauki.pl/articles/167396.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Górnictwa
Tematy:
migracja gazu
mikrotomografia komputerowa
jakość zacementowania
gas migration
computed microtomography (μCT)
cementing job quality
Opis:
Artykuł opisuje badania nad negatywnym zjawiskiem występującym w wiertnictwie otworowym pod nazwą migracja gazu z wykorzystaniem metody mikrotomografii komputerowej μCT (ang. computed microtomography). Opisano główne przyczyny powstawania tego negatywnego zjawiska polegającego na przepływie gazów, a także płynów w zaczynie cementacyjnym lub kamieniu cementowym. Przygotowano próbki imitujące zacementowany odcinek rur okładzinowych. Skupiono się na wykorzystaniu mikrotomografii komputerowej, oraz analizie zrekonstruowanego trójwymiarowego obrazu w celu sprawdzenia jakości zacementowania. Przedstawiono zalety tej metody oraz możliwości analizy powstałych kamieni cementowych.
This paper presents a description of the gas migration phenomenon. Main causes of this negative phenomenon consisting in fluid or gas flow in the cement slurry or bounded cement sheath have been described. The paper describes the use of the computed microtomography (μCT) and analysis of the reconstructed three-dimensional (3D) images, in order to check the quality of cementation samples prepared at the Faculty of Mechanical Engineering. The paper presents the advantages and opportunities of X-ray computed microtomography analysis of the bonded cement sheath.
Źródło:
Przegląd Górniczy; 2017, 73, 5; 50-57
0033-216X
Pojawia się w:
Przegląd Górniczy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A multistep approach for micro tomography obtained medical image segmentation
Autorzy:
Buczkowski, M.
Saeed, K.
Powiązania:
https://bibliotekanauki.pl/articles/332884.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
image segmentation
bilateral filter
Canny-Deriche edge detector
microtomography
porous materials
segmentacja obrazu
filtr dwustronny
wykrywanie krawędzi
mikrotomografia
materiały porowate
Opis:
This paper presents a multistep approach for segmentation of micro tomography images. Various images of porous structures were studied. Proper segmentation of that images is necessary to create 3D models of these structures. The introduced algorithm concerns finding the proper way of image filtering before the use of Canny-Deriche edge detection to obtain the best possible segmentation.
Źródło:
Journal of Medical Informatics & Technologies; 2014, 23; 69-76
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Struktura wewnętrzna i geneza współczesnej pokrywy solnej solniska Salar de Uyuni (Boliwia) w świetle badań tomograficznych
Internal structure and origin of modern salt crust of Salar de Uyuni (Bolivia) salt pan based on tomographic research
Autorzy:
Burliga, S.
Dohnalik, M.
Powiązania:
https://bibliotekanauki.pl/articles/183455.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
Salar de Uyuni
współczesne osady solne
poligony z wysychania
mikrotomografia rentgenowska
modern salt deposits
desiccation polygons
X-ray microtomography
Opis:
W pracy przedstawiono rezultaty badań budowy wewnętrznej współczesnej pokrywy solnej solniska Salar de Uyuni w południowo-zachodniej Boliwii. Analizie poddano również budowę wypełnień szczelin z wysychania. Podstawową techniką badawczą była mikrotomografia rentgenowska, obrazująca pełną strukturę wewnętrzną prób bez ich destrukcji. Badania wykazały trójdzielność struktury pokrywy: obecność powłoki halitowej na powierzchni, warstwy halitytów komórkowych poniżej powłoki oraz warstwy halitytów wielkoporowych w części spągowej pokrywy. Szczeliny z wysychania wypełniają halityty pęcherzykowate. Rozmieszczenie materiału mułowego w próbie oraz rozmycia kryształów przypowierzchniowych wskazują na wielokrotność cykli rozpuszczania soli, krystalizacji halitu i depozycji mułów. Na tej podstawie sformułowano wniosek, iż obserwowane w skałach warstwowanie nie odzwierciedla rocznych cykli sedymentacyjno-ewaporacyjnych, lecz cykle wieloletnie. Tłumaczy to niskie średnie tempo przyrostu osadów na solnisku.
This paper presents the results of a study on the internal structure of modern salt crust of Salar de Uyuni in SW Bolivia. Additionally, the structure of desiccation fissure infill was investigated. X-ray microtomography was used as the main analytical method because it enabled the complete structure of the sample's interior to be imaged without its destruction. Based on microtomographic images three layers were distinguished in the crust between the surface and its base: a halite shell at the top, a cellular halite layer in the middle and a large-pore halite layer at the base. Results revealed that the desiccation fissures are filled with extremely porous bubble-halite. Distribution of mud in the sample as well as wash-out of the surfical halite crystals indicate the cyclicity of halite dissolution, its crystallisation and mud accumulation. These observations provide an explanation for low rate salt accumulation in the salt pan. This leads to the conclusion that the observed layering in the rocks does not reflect annual sedimentation-evaporation cycles but rather long-term cycles.
Źródło:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie; 2011, 37, 2; 215-229
0138-0974
Pojawia się w:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie 3D struktury przestrzeni porowej cementów metodą mikrotomografii rentgenowskiej (micro-CT)
Examination of internal pore space 3D images of cement rock with use of Roentgen Computed Tomography (Micro-CT)
Autorzy:
Dohnalik, M.
Zalewska, J.
Kut, Ł.
Kaczmarczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/349787.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
cement
struktura porowa kamieni cementowych
rozwój porowatości
mikrotomografia
cement rock pore structure
pore structure evolution
microtomography
Opis:
Metoda mikrotomografii rentgenowskiej (micro-CT) jest nieniszczącą metodą badawczą, która umożliwia wizualizację budowy wewnętrznej obiektów (w geologii np. skał i cementów). Metoda polega na rejestracji projekcji promieniowania X badanej próbki pod różnymi kątami, a następnie rekonstrukcji na tej podstawie struktury wewnętrznej próbki. Wizualizowanym parametrem jest współczynnik atenuacji liniowej, który zależy od energii promieniowania X, liczby atomowej pierwiastków budujących obiekt oraz gęstości badanej próbki. Micro-CT może być stosowana zarówno do jakościowej wizualizacji wewnętrznej struktury cementów, jak również do pozyskiwania danych ilościowych. Celem tego artykułu jest przedstawienie zastosowania mikrotomografii rentgenowskiej w badaniu cementów. W pracy zaprezentowano, po raz pierwszy w kraju, wyniki mikrotomograficznych badań mikrostruktury zaczynów cementowych w różnym wieku (1 do 28 dni). Wyniki pozwoliły przeanalizować zmiany w sieci porowej zaczynów podczas ich starzenia. Wykazano znaczące różnice w ewolucji porów pomiędzy próbami zaczynów o różnych składach. Wyniki te pokazują możliwości metody micro-CT w badaniu materiałów cementowych. Główną zaletą metody jest możliwość odtworzenia sieci porowej oraz prześledzenia zmian wielkości porów w czasie. Dzięki tej metodzie możliwe jest także badanie nowych cech, takich jak dystrybucja przestrzenna struktury porowej oraz określenie jej przewodności.
The X-ray computed microtomography (micro-CT) is a non-destrictive method for visualization of objects' internal structures (in geology - e.g. rocks or cement stones). Sample's X-ray projections at different angles are recorded and, on the basis of them, the objects' internal structure is reconstructed. Visualized parameter is the linear attenuation coefficient (proportional to X-ray's energy, material's density and atomic number of elements in object's structure). The micro-CT may be used to visualize the cement's internal structure and its quantitative analysis. The aim of this paper is to show application of micro-CT in cementary rocks examination. In this work the results of micro-CT measurement for cements of different age (1-28 days) are shown first time in Poland. Obtained results allowed to analyze changes of pore network during the cement rock's shrinking. Significant pore space evolution changes in case of cement rocks with different composition were observed. Results shown that micro-CT method is applicable for cement rocks examination. The main adventage of micro-CT is the ability to reconstruction of pore space and observation of its changes in time. Also the pores' spatial distribution and tortuosity may be examined.
Źródło:
Górnictwo i Geoinżynieria; 2010, 34, 4; 157-165
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary porowatości skał metodą rentgenowskiej mikrotomografii komputerowej (Micro-CT)
Rock porosity measurements using Roentgen computed microtomography (Micro-CT)
Autorzy:
Dohnalik, M.
Zalewska, J.
Powiązania:
https://bibliotekanauki.pl/articles/183665.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
porowatość
mikrotomografia
porosity
microtomography
Opis:
Roentgen computed microtomography is an imaging technique that generates high resolution 3D images of internal structure, basing on difference in X-rays absorption inside the sample. Micro-CT provides new possibilities to obtain up to few microns resolution images of reservoir rocks in non destructive way. Such images enables to visualize and quantitative analysis of mineral composition and pore structure (volume, shape and pore throat diameter), which can be used to better understanding petrophysical properties such as permeability. This paper shows test of direct, quantitative porosity measurement based on 3D images obtained using Benchtop device and AVIZO software.
Źródło:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie; 2009, 35, 2/1; 617-624
0138-0974
Pojawia się w:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka utworów czerwonego spągowca w aspekcie badań rentgenowskiej mikrotomografii komputerowej i mikroskopii optyczne
Characteristics of Rotliegend sediments in view of X-ray microtomohraphy and optical microscopy investigations
Autorzy:
Dohnalik, Marek
Ziemianin, Konrad
Powiązania:
https://bibliotekanauki.pl/articles/1833915.pdf
Data publikacji:
2020
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
czerwony spągowiec
mikrotomografia
petrografia
własności zbiornikowe
Rotliegend
microtomography
petrography
reservoir properties
Opis:
The article presents the results of microtomographic and petrographic investigations of Rotliegend sandstones collected from core material from wells located in the area of the Fore-Sudetic Monocline in its central and northern parts and also on the border of the Fore-Sudetic Monocline and the Mogilno - Łódź Synclinorium. Three areas were selected for the study: Czarna Wieś–Parzęczewo (19 samples), Środa Wielkopolska–Kromolice (21 samples) and Siekierki–Miłosław (21 samples). The aim of the petrologic and microtomographic studies was to investigate how the different reservoir properties of sandstones will be reflected in the results of the methods used. Strong differences between samples from the region of Środa Wielkopolska–Kromolice and the other studied areas have been demonstrated. In the case of this area several key factors were noticed: the highest average value of effective porosity; the highest average content of pores belonging to class VII (pore volume subsystem classification); three times higher average value of the CT porosity coefficient and the largest length of the average chord. Also in terms of petrography (composition of grains, cement type) it is a region where major differences, especially compared to the region of Czarna Wieś–Parzęczewo, can be seen. Based on the obtained results, it was possible to rank the examined regions in terms of their reservoir properties – from the worst (Czarna Wieś–Parzęczewo) to the best (Środa Wielkopolska–Kromolice). These conclusions are also confirmed by other petrophysical analyses (eg. mercury porosimetry, permeability analysis). Combination of the obtained microtomographic and petrographic results allowed to obtain a full characterization of the investigated samples – both in terms of the mineralogical composition of grains, as well as the development of the pore space. These data, especially in combination with the results of density and porosity analyses (helium pycnometry and mercury porosimetry), open up a number of possibilities to carry out different types of modeling (porosity, permeability) both on the scale of the sample itself, as well as the scale of a single well or even the whole basin, which is crucial for creating a hydrocarbon exploration strategy.
Źródło:
Nafta-Gaz; 2020, 76, 11; 765--773
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of the tension and compression behavior of sintered 316L using micro computed tomography
Autorzy:
Doroszko, M.
Seweryn, A.
Powiązania:
https://bibliotekanauki.pl/articles/387023.pdf
Data publikacji:
2015
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
finite element method
X-ray microtomography
porous materials
mechanical properties
plasticity
metoda elementów skończonych (MES)
mikrotomografia rentgenowska
materiały porowate
plastyczność
właściwości mechaniczne
Opis:
This paper describes the method of numerical modeling of the tension and compression behavior of sintered 316L. In order to take into account the shape of the mesostructures of materials in the numerical modeling, X-ray microtomography was used. Based on the micro-CT images, three-dimensional geometrical models mapped shapes of the porosity were generated. To the numerical calculations was used finite element method. Based on the received stress and strain fields was described the mechanism of deformation of the materials until fracture. The influence of material discontinuities at the mesoscopic scale on macromechanical properties of the porous materials was investigated.
Źródło:
Acta Mechanica et Automatica; 2015, 9, 2; 70-74
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przestrzenne badanie systemu porowego skał węglanowych na podstawie cyfrowej analizy obrazów mikrotomograficznych z wykorzystaniem języka Python
Spatial analysis of carbonate pore system based on digital image analysis of X-ray microtomography data using Python language
Autorzy:
Fheed, Adam
Hadro, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2076181.pdf
Data publikacji:
2021
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
mikrotomografia rentgenowska
Phyton
węglanowe skały zbiornikowe
porowatość
X-ray microtomography
Python
carbonate reservoir rocks
porosity
Opis:
The main aim of this contribution is to combine a Python-supported analysis of X-ray microtomography (µCT) images and the transmitted-light microscopy to resolve the factors controlling the variability of petrophysical parameters in carbonate rocks. A self-developed Python script for the evaluation of pore connectivity and the computation of pore sizes based on µCT data was prepared. The script was launched on a carbonate sample with drawn from a drill core representing the Late Permian Zechstein Limestone (Ca1) formation from the Wolsztyn Ridge area in West Poland. The sample was taken from the upper part of the isolated Kokorzyn Reef, corresponding to a brachiopod and bivalve-rich zone. The plug had a cylindrical shape, the diameter of 2.54 cm and the height of approximately 4.6cm. The entire volume of the plug was scanned using a GE Nanotom Sdevice. The 3D-reconstructeddatasetobtainedwith spatial resolution of 0.02 mm underwent cropping, contrast adjustment, noise reduction and porosity extraction using open-source Fiji software. The binarized porosity image was loaded into the Python script. Python scripting was found efficient in carbonate pore system examination. The code first extracted the connected pore system of the largest volume and computed the smallest distances between porosity voxels and corresponding pore walls. The obtained results were confronted with the spatially-adjusted microphotographs taken in plane-polarized transmitted light. The results have shown that narrow and isolated pores occurred within the spines of brachiopods. The largest voids were found inside the brachiopod shells. Moreover, many pores were associated with partially dissolved fragments of bivalves. Porosity reduction was -most outlined in the zones showing the scarcity of fossils.
Źródło:
Przegląd Geologiczny; 2021, 69, 6; 357--360
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problem of the objects detection on low quality 3D image – example solution
Autorzy:
Gądek-Moszczak, A.
Powiązania:
https://bibliotekanauki.pl/articles/114988.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
image processing
low contrast
noise
X-ray microtomography
przetwarzanie obrazu
hałas
mikrotomografia rentgenowska
redukcja szumów
poprawa kontrastu
Opis:
Precise detection of analyzed objects is crucial and the most important task in quantitative and qualitative image of the microstructure analysis. The most common image distortion is noise, artefacts and low contrast. In the paper, author on the example of poor quality image of the polyurethane-polystyren composite structure, obtained with the X-ray microtomograph, presented possible methods of noise reduction, contrast enhancement, and correction of detection errors on the binary image.
Źródło:
Zeszyty Naukowe. Quality. Production. Improvement; 2017, 1 (6); 134-141
2544-2813
Pojawia się w:
Zeszyty Naukowe. Quality. Production. Improvement
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parametry morfologiczne pian stałych –metody i wyzwania
Morphological parameters of solid foams – chalanges faced
Autorzy:
Gancarczyk, A.
Iwaniszyn, M.
Piątek, M.
Leszczyński, B.
Ziółkowski, G.
Piech, D.
Janus, B.
Kleszcz, T.
Kołodziej, A.
Powiązania:
https://bibliotekanauki.pl/articles/306081.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Instytut Inżynierii Chemicznej PAN
Tematy:
piany stałe
parametry morfologiczne
mikrotomografia komputerowa
solid foam
morphological parameters
computed microtomography
Opis:
Parametry morfologiczne pian stałych wyznaczone zostały przy użyciu mikrotomografii komputerowej, mikroskopii optycznej oraz piknometrii helowej. Dla pierwszej z zaproponowanych technik sprawdzono wpływ wielkości woksela oraz metody binaryzacji obrazów na mierzone wielkości. Porównano wartości parametrów morfologicznych pian stałych otrzymane zaproponowanymi technikami oraz przedyskutowano ewentualne różnice.
Morphological parameters of the solid foams have been determined using computed microtomography, optical microscopy and helium pycnometry. For the first technique, impacts were studied of the voxel size and method of the image binarization on the measured parameters. Morphological parameters derived were compared and the differences discussed.
Źródło:
Prace Naukowe Instytutu Inżynierii Chemicznej Polskiej Akademii Nauk; 2016, 20; 155-165
1509-0760
Pojawia się w:
Prace Naukowe Instytutu Inżynierii Chemicznej Polskiej Akademii Nauk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interpretacja jakościowa i ilościowa przestrzeni porowej piaskowca karbońskiego na podstawie wyników rentgenowskiej tomografii komputerowej
Qualitative and quantitative interpretation of Carboniferous sandstone pore space on the basis of X-ray computed tomography results
Autorzy:
Gołda, P.
Krakowska, P.
Powiązania:
https://bibliotekanauki.pl/articles/1835253.pdf
Data publikacji:
2018
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
petrofizyka
rentgenowska mikrotomografia komputerowa
przestrzeń porowa
krętość kanałów porowych
porowatość całkowita
porowatość efektywna
petrophysics
computed microtomography
pore space
tortuosity
total porosity
effective porosity
Opis:
W pracy przedstawiono analizę przestrzeni porowej dwóch próbek karbońskich piaskowców kwarcowych z wykorzystaniem rentgenowskiej tomografii komputerowej (CT). Pierwszy etap prac stanowiło przetwarzanie obrazów CT. Przetwarzanie miało na celu poprawę stosunku sygnału do szumu oraz podniesienie rozpiętości tonalnej obrazów. Kolejnym etapem było stworzenie obrazu zbinaryzowanego. Następnie na podstawie przekrojów 2D i obrazu 3D dokonano interpretacji jakościowej i ilościowej przestrzeni porowej. Interpretacja jakościowa polegała na porównaniu uzyskanych podgrup sieci porowej między sobą, jak też między próbkami. Wyliczono porowatość całkowitą oraz zmiany porowatości w kolejnych przekrojach CT. Dane posłużyły również do analizy pola powierzchni porów oraz do policzenia charakterystyki Eulera. Obiekt charakteryzujący się największą objętością został użyty do obliczenia porowatości efektywnej, długości sieci porowej, liczby gałęzi i skrzyżowań, krętości kanału porowego. Uzyskana porowatość całkowita była zbliżona do obliczonej z wykorzystaniem innych metod laboratoryjnych. Policzono też liczbę porów przypadającą na każdy przekrój oraz średni rozmiar porów na przekrój CT. Dokonano podziału przestrzeni porowej próbek na klasy powierzchni, obliczono liczbę porów przyporządkowanych do danej klasy oraz ich procentowy udział w budowaniu całej przestrzeni porowej. Dla sieci porów odizolowanych dokonano podziału na klasy objętości, następnie stwierdzono liczbę elementów w danej klasie oraz jej procentowy udział. Próbka nr 1 wykazała heterogeniczność w wykształceniu przestrzeni porowej, cechowała się większą liczbą porów, lepszą jakością połączeń struktury porowej oraz miała więcej porów o mniejszych objętościach. Średni rozmiar porów próbki nr 2 był większy. Przestrzeń porową próbki nr 2 tworzyły pory o większej powierzchni. Obliczona krętość kanału porowego wynosiła 2,17. Micro-CT okazało się dobrym narzędziem do szczegółowej analizy budowy przestrzeni porowej skał.
The paper presents an analysis of the pore space of two Carboniferous quartz sandstone samples using X-ray computed tomography (CT). The first stage of the work was the processing of CT images. The processing was aimed at improving the signal-to-noise ratio and increasing the tonal range of images. The next stage was to create a binary image. Next, a qualitative and quantitative interpretation of the pore space was made on the basis of 2D sections and 3D images. The qualitative interpretation consisted in comparing the obtained pore network subgroups with each other and between samples. The total porosity and changes in porosity in subsequent CT cross-sections were calculated. The data also served to analyze the pore surface area and to calculate the Euler’s characteristics. The object with the largest volume was used to calculate the effective porosity, the length of the pore network, the number of branches and intersections, and the tortuosity of the pore channel. The obtained total porosity was similar to that calculated using other laboratory methods. The number of pores per each cross-section and the average pore size per CT section were also counted. The pore space of samples was divided into surface classes. The number of pores assigned to a given class was calculated as well as their percentage share in building the entire pore space. For the network of isolated pores, the division into volume classes was made, then the number of elements in a given class and its percentage share were counted. Sample no. 1 showed heterogeneity in the development of pore space, was characterized by more pores, better quality of pore structure connections and had more pores with smaller volumes. The average pore size of sample no. 2 was larger. The pore space of sample no. 2 was made up of pores with a larger surface area. The calculated tortuosity of the pore channel was 2.17. Micro-CT proved to be a good tool for a detailed analysis of the structure of the rocks pore space.
Źródło:
Nafta-Gaz; 2018, 74, 7; 487-494
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie mikrotomografii komputerowej do badania orientacji klastów w glinach lodowcowych
Application of computed microtomography in clast orientation studies in glacial tills
Autorzy:
Hermanowski, Piotr
Duda, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2075992.pdf
Data publikacji:
2019
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
mikrotomografia
gliny lodowcowe
drumlin
procesy subglacjalne
stargardzkie pole drumlinowe
microtomography
glacial till
subglacial processes
Stargard drumlin field
Opis:
Limitations of macroscopic measurements and observations of glacial tills, no matter how informative they are, have contributed to the development of micromorphological analysis first in thin sections, since the 80’s using X-ray computed tomography, and recently X-ray computed microtomography (μ-CT). The цCT has found wide applications in science including earth sciences where is used for imagining various geological samples in the 3D view. The sampling procedure and preparation of samples do not generate much effort, and eventually, allow analysis of samples with a preserved undisturbed structure. Herein, we present a short review and methodology of μCT as well as its application to the study of glacial tills. For example, we analyzed a subglacial till sample from the lee side of a drumlin located in the Stargard drumlin field area, NW Poland. The results show a distinctive bimodal pattern of clast fabrics which is interpreted as a result of subglacial till squeezing. Smaller clasts are obliquely oriented to the major direction of the ice flow whereas the larger clasts orientation is approximately in accordance with the major shear stress direction. Overall, our data emphasize the potential of the μ-CT in glacial till studies.
Źródło:
Przegląd Geologiczny; 2019, 67, 8; 653--661
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości wykorzystania wysokorozdzielczej mikrotomografii komputerowej w badaniach geologiczno-inżynierskich na przykładzie analizy iłów mio-plioceńskich
The possibility of using high-resolution X-ray computed microtomography in engineering geology analysis, based on a study of Mio-Pliocene clays
Autorzy:
Kaczmarek, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/2075555.pdf
Data publikacji:
2016
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
wysokorozdzielcza mikrotomografia
geologia inżynierska
iły mio-plioceńskie
stacja metra Kopernik
computed microtomography
engineering geology
Mio-Pliocene clay
Kopernik underground station
Opis:
The paper considers the use of high-resolution X-ray computed microtomography (μCT) as a possible method in engineering-geological laboratory research for indicating areas of weakness, location of fissures and determining homogeneity of clay samples. Furthermore, the studies were used to provide methodological guidance. Mio-Pliocene (Neogene) clay samples were taken from an excavation site of the Kopernik underground station in Warsaw. First, natural humidity, bulk density and fraction analyses of samples were made. Secondly, μCT scans were conducted, with the use of copper filters. In the final stage of the study, internal structure images for samples were processed and analysed. Furthermore, a numerical model of dry sample was developed. During the study it was observed that the increase of temperature caused by X-ray radiation has a destructive effect on the sample. This effect was eliminated by applying a protective layer on the sample, using engine oil. The article quantifies the ratio of radiation-heated fissure volume to dry sample volume and the natural fissure volume to sample volume. Moreover, sample areas with different densities or chemical composition were studied. The results lead to the conclusion that the μCT technique is applicable to characterise of Mio-Pliocene clay, supplying internal structure assessment and fissure quantification that allow for samples verification to further engineering geology in-depth analysis.
Źródło:
Przegląd Geologiczny; 2016, 64, 2; 105--112
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies