Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "microbiological pollution" wg kryterium: Temat


Wyświetlanie 1-10 z 10
Tytuł:
Microbiological Risk in Rooms with Mechanical Ventilation
Autorzy:
Lisik, Katarzyna
Cichowicz, Robert
Powiązania:
https://bibliotekanauki.pl/articles/2202136.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
mechanical ventilation
microbiological pollution
dust pollution
air quality
bioaerosol
Opis:
The condition of air quality depends on many external (the amount of pollutant emissions, intensity and type of physico-chemical changes taking place in the atmosphere and large-scale movement of air pollutant masses) as well as internal factors (such as finishing materials, room equipment, heating systems, ventilation systems, and the presence of the humans themselves). As a result, there are various risks related to air quality, including the most important ones related to microbial contamination. For this reason, it was decided to analyze the quality of internal air in terms of microbiological contamination that may occur in university lecture halls with mechanical supply and exhaust ventilation. The analysis also took into account the impact of mechanical ventilation on physical parameters such as temperature, relative humidity as well as the concentration of PM10 and PM2.5 particulate matter pollutants, thus determining the impact of the tested parameters on human health and well-being. All the obtained results were compared with the applicable permissible standards and conclusions were drawn regarding the improvement of the quality of the indoor air microclimate.
Źródło:
Journal of Ecological Engineering; 2022, 23, 10; 164--171
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbiological pollution of soils and surface waters of the Pokuttia-Bukovyna Carpathians
Autorzy:
Masikevych, Andrij
Masikevych, Yurij
Malovanyу, Myroslav S.
Blyzniuk, Mykola
Powiązania:
https://bibliotekanauki.pl/articles/2174329.pdf
Data publikacji:
2022
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
bacteria
ecosystem
hydrosphere
microbiological pollution
national nature park
soil
Opis:
Based on the analysis of a number of studies, it was found that to assess the state of the environment (including surface waters and soils) it is advisable to use indicators of microbiological pollution, which in general integrally reflect the state of the ecosystem. To assess the dynamics of changes in the pollution of the studied areas, a comparison of monitoring data with the corresponding level of pollution in protected areas (Vyzhnytsia National Nature Park) was used. Research methods included soil and surface water sampling, inoculation on appropriate nutrient selective media, counting of colony forming units (CFU) and other microbiological indicators. To assess the biological activity of soils, urease activity was determined by a method generally accepted in biochemistry. It is established that within the protected areas, despite some existing annual fluctuations, the relative stability of the studied indicators of the hydrosphere is preserved. Studies have shown that soils of anthropogenically altered landscapes are characterised by a high content of sanitary-indicative bacteria. As our research shows, according to the colony forming units (CFU), total microbial count, and titer of Escherichia coli, the soils selected in the protected area of the Vyzhnytsia National Nature Park correspond to the “pure” level. The soils of the territories out of the National Nature Park are characterised by high biological capacity, as evidenced by the level of activity of the enzyme urease and the ratio of the main forms of nitrogen compounds.
Źródło:
Journal of Water and Land Development; 2022, 55; 91--96
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effectiveness of removing microbial pollutants from wastewater by the activated sludge method
Autorzy:
Budzińska, K.
Szejniuk, B.
Jurek, A.
Traczykowski, A.
Michalska, M.
Berleć, K.
Powiązania:
https://bibliotekanauki.pl/articles/208224.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
wastewater treatment
water pollution
microbiological pollution
Salmonella
activated sludge
pathogenic microorganisms
Enterobacteriaceae
oczyszczanie ścieków
zanieczyszczenie wody
zanieczyszczenie mikrobiologiczne
osad czynny
mikroorganizmy chorobotwórcze
bakterie jelitowe
Opis:
Wastewater contains numerous saprophytic microorganisms, pathogenic and potentially pathogenic. Detection of bacteria indicating the sanitary state of polluted waters shows the possibility of occurring of pathogenic microorganisms in that environment. In the presented paper, the effectiveness of removing microbiological pollutions from wastewater treated by the activated sludge method has been evaluated, by estimating the elimination of E. coli, faecal streptococci, rods of the genus Salmonella and bacteria of the family Enterobacteriaceae. Experimental research showed that often in spite of a high degree of elimination of bacteria at individual stages of treatment, they are still identified in wastewater discharged to the water environment. The fact of occurring bacteria of the family Enterobacteriaceae and rods of Salmonella in treated wastewater discharged to surface waters is particularly worrying.
Źródło:
Environment Protection Engineering; 2014, 40, 4; 53-67
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring stanu czystosci mikrobiologicznej wod Pradnika na terenie Ojcowskiego Parku Narodowego
Autorzy:
Chmiel, M
Zaprzelska, M.
Powiązania:
https://bibliotekanauki.pl/articles/797625.pdf
Data publikacji:
2006
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
czystosc mikrobiologiczna
rzeki
zanieczyszczenia mikrobiologiczne
monitoring
czystosc wod
Ojcowski Park Narodowy
rzeka Pradnik
microbiological purity
river
microbiological pollution
water purity
Ojcow National Park
Pradnik River
Opis:
W niniejszej pracy przedstawiono wyniki badań dotyczących czystości mikrobiologicznej wody rzeki Prądnik znajdującej się na obszarze Ojcowskiego Parku Narodowego. W ramach prowadzonych badań oznaczano liczebność bakterii mezofilnych, drożdży, grzybów pleśniowych oraz bakterii grupy coli. Uzyskane wyniki sugerują duże zmiany sezonowe w liczebności badanych grup mikroorganizmów zależne od temperatury powietrza i wody. Największe zanieczyszczenie mikrobiologiczne wody notowano w punktach położonych na terenie Ojcowa a najmniej skażone były próbki wody pobierane w punktach o dużej prędkości przepływu wody, zlokalizowane w bliskości źródeł zasilających potok oraz w oddaleniu od zabudowań gospodarczych. Potok Prądnik jest zbyt zanieczyszczony pod względem mikrobiologicznym, jak na ciek znajdujący się na terenie Parku Narodowego.
The paper presents the results of study on microbiological contamination of water of Prądnik river in the Ojcowski National Park area. The number of mesophilic bacteria, yeasts, moulds and MPN of coli group bacteria was examined. The obtained results suggest seasonal changes in the number of tested groups of microorganisms depending on the water and air temperature. A higher microbiological contamination of water was found in stations located in Ojców, while samples collected from stations of rapid water flow, located in the vacinity of the stream feeding sources, as well as those situated far from the farmhouses were least contaminated. Microbiological contamination of the Prądnik river far exceeded the limits expected for a stream situated within the boundaries of the National Park.
Źródło:
Zeszyty Problemowe Postępów Nauk Rolniczych; 2006, 515; 31-36
0084-5477
Pojawia się w:
Zeszyty Problemowe Postępów Nauk Rolniczych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagrożenia mikrobiologiczne w pomieszczeniach biurowych
Microbiological contaminants in office buildings
Autorzy:
Gołofit-Szymczak, M.
Skowroń, J.
Powiązania:
https://bibliotekanauki.pl/articles/180788.pdf
Data publikacji:
2005
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
zagrożenia mikrobiologiczne
zanieczyszczenie powietrza
pomieszczenia biurowe
microbiological hazards
air pollution
office space
Opis:
Czynnikami biologicznymi, na jakie może być narażony pracownik w pomieszczeniu biurowym, są bakterie, grzyby oraz wytwarzane przez nie struktury i substancje. W artykule zanieczyszczenia mikrobiologiczne, które mogą stanowić zagrożenie dla zdrowia osób narażonych na ich działanie. Mogą one wywoływać choroby alergiczne oraz infekcje dróg oddechowych.
Biological contamination of indoor air in office buildings includes bacteria and their spores, fungi, fungal spores and metabolic products from the microorganisms. Indoor biological contaminants can be responsible for a variety of adverse health effects. Physical symptoms related to biological contamination include allergy, hypersensitivity, and infectious diseases.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2005, 3; 29-31
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikrobiologiczne zanieczyszczenie powietrza na terenie oczyszczalni ścieków komunalnych
Microbiological air pollution in the area of municipal sewage treatment plant
Autorzy:
Budzińska, K.
Jurek, A.
Szejniuk, B.
Michalska, M.
Wroński, G.
Powiązania:
https://bibliotekanauki.pl/articles/1819427.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
komunalna oczyszczalnia ścieków
zanieczyszczenie powietrza
zanieczyszczenie mikrobiologiczne
municipal sewage treatment plant
air pollution
microbiological contamination
Opis:
Doświadczenia prowadzone w zasięgu oddziaływania oczyszczalni ścieków wykazały, że skład gatunkowy i ilościowy mikroflory powietrza jest ściśle powiązany z rodzajem i liczbą mikroorganizmów obecnych w ściekach. W skład bioaerozoli w rejonach oczyszczalni ścieków wchodzą bakterie, wirusy oraz liczne gatunki grzybów, w tym mikotoksyczne i alergizujące. Takie aerozole biologiczne sprzyjają odczynom alergicznym, chorobom zakaźnym, a nawet epidemiom i epizootiom. Według doniesień literaturowych [2, 5, 10] czynnikiem umożliwiającym powstawanie bioaerozolu wokół oczyszczalni jest liczba mikroorganizmów obecnych w ściekach. Jako graniczną wartość przyjmuje się zawartość drobnoustrojów na poziomie wyższym od 103 w 1 ml, co warunkuje możliwość uniesienia komórek do powietrza [15]. Do podstawowych parametrów decydujących o zasięgu i stopniu oddziaływania wpływu oczyszczalni ścieków na mikrobiologiczną czystość powietrza należą: wielkość obiektu, stosowana technologia procesów oczyszczania ścieków, sposób przeróbki i postępowania z osadami ściekowymi, staranność eksploatacji obiektów i inne [1, 2]. Drobnoustroje trafiają do powietrza przede wszystkim na skutek realizacji procesów związanych z napowietrzaniem i mieszaniem ścieków oraz rozprowadzaniem ich na urządzeniach biologicznych [11÷13]. W ciągu technologicznym oczyszczalni ścieków można wyróżnić kilka newralgicznych punktów, które w sposób szczególny wpływają na emisję bioaerozoli. Najbardziej negatywny wpływ odnotowano w przypadku urządzeń takich jak kratownia, pompownia wstępna, kanały ścieków surowych, piaskownik, komora napowietrzania i poletka osadowe [5]. Duże ryzyko zdrowotne związane z emisją szkodliwych bioaerozoli powoduje, że konieczne jest prowadzenie kontroli czystości mikrobiologicznej powietrza na terenie i wokół oczyszczalni ścieków. Celem badań było określenie zanieczyszczenia mikrobiologicznego powietrza na terenie mechaniczno-biologicznej oczyszczalni ścieków komunalnych.
The aim of this study was to estimate a degree of microbiological air pollution in the area of a mechanical-biological municipal sewage treatment plant. Four measurement points were situated in the area of the and one research stand was located outside the plant from the windward side (background) - near screen, near sand catchers, at aeration chambers, at sewage sludge deposition site. Air samples were collected in a trail of pollution with the compaction method using the sampler SAS 100. The microbiological analyses involved the quantitative analysis of the following microorganisms: total number of bacteria and fungi, haemolysing staphylococci and , mannitol-positive and mannitol-negative staphylococci, Pseudomonas fluorescens, actinomyces and bac-teria of the Enterobacteriaceae family. Total number of bacteria in particular measurement points varied and ranged from 320 to 4565 cfu in 1 m3 of air. The highest emission of those microorganisms was observed in the vicinity of appliances for mechanical sewage treatment (screen site). The next measurement point where a high number of bacteria was recorded was location in the vicinity of the sewage sludge deposition site. The number of mould fungi occurring in the air at all the measurement points was low and ranged from 420 to 5429 colonies.m-3. The highest concentration of actinomyces in the air was observed in the vicinity of the sewage sludge storage site, where their number ranged from 55 to 450 cfu.m-3. The highest emission of Pseudomonas fluorescens from sewage to the air was observed at the point over the aeration chamber, where in the summer period the number of these bacteria exceeded two-fold 50 cfu.m3, which indicates strong air pollution. The largest number of haemolysing bacteria of type was found at all measurement stands in the spring-summer period, where their concentration from 0 to 48 cfu.m-3. The number of type bacteria determined in the air at the measurement points was within the range from 0 to 27 cfu.m-3, and the largest number was found at the point located over the aeration chamber. The study also involved the determination of the number of mannitol-positive staphylo-cocci, which values permissible for clean air should not exceed 100 cfu.m-3. Mannitol-positive staphylococci in the examined air oc-curred at a low level and in no samples exceeded the number for clean air proposed in the project PN-Z-04111-1 concerning air cleanliness protection. The concentration of potentially pathogenic bacteria of the Entero-bacteriaceae family was the highest in air samples collected in the vicini-ty of the sewage sludge storage place, where their number oscillated from 67 to 523 cfu.m-3, and at the screen site (22-320 cfu.m-3). The results of the study show that sludge-drying beds are an important source of micro-organism emission on the premises of a sewage treatment plant. The greatest number of microorganisms was found in air samples collected in late spring and summer. The exception was actinomyces, which occurred in the maximal amount in autumn. The assessment of degree of air pollu-tion indicates that there is a potential risk of exposure sewage treatment plant staff to harmful biological factors leading to disease incidence (bacteria of the Enterobacteriaceae family, and -haemolysing microor-ganisms and mannitol-positive staphylococci). The investigations show the need for constant monitoring of the effect of a sewage treatment plant on the air environment, which will enable efficient prevention of people working at sewage treatment plants.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 1543-1558
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbial and chemical quality assessment of the small rivers entering the South Baltic. Part 1, Case study on the watercourses in the Baltic Sea catchment area
Autorzy:
Bączkowska, Emilia
Kalinowska, Agnieszka
Ronda, Oskar
Jankowska, Katarzyna
Bray, Rafał
Płóciennik, Bartosz
Polkowska, Żaneta
Powiązania:
https://bibliotekanauki.pl/articles/2073797.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Baltic Sea
environmental pollution
fecal coliforms
coastal rivers
microbiological quality
chemical quality
Coastal Landscape Park
Opis:
The area of the Coastal Landscape Park (CLP) due to its location is extremely attractive touristic area. In the summer season, a significant increase in population density is observed, which influences surface water quality. Large numbers of tourists generate an increased amount of municipal wastewater, being treated in local treatment plants and discharged into rivers and streams. The paper presents preliminary research from summer 2016 on three watercourses ending in the Baltic Sea: Piaśnica, Karwianka and Czarna Wda rivers. It is a part of a long-term project conducted in CLP to assess surface waters quality. The scope of research included measurements of in situ parameters (temperature, conductivity, pH, dissolved oxygen). Chemical Oxygen Demand was determined using a spectrophotometer. Ion chromatography was used to determine ions concentrations (including biogenic compounds). Sanitary state of watercourses was assessed based on fecal coliforms abundance, which number was determined by the cultivation method. The determination of microbiological parameters such as: prokaryotic cell abundance expressed as total cells number (TCN), prokaryotic cell biovolume expressed as average cell volume (ACV), the prokaryotic biomass (PB) and prokaryotic cell morphotype diversity was determined using epifluorescence microscopy method. Results showed that water quality of Piaśnica and Czarna Wda rivers were affected by discharged treated wastewater. In the case of Karwianka River, the main pollution source could be surface runoff from fields and unregulated sewage management in this area. The conducted research confirmed the urgent need for better protection of this area to conserve both its ecosystem and value for tourism.
Źródło:
Archives of Environmental Protection; 2021, 47, 4; 55--73
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Endotoxins and beta-glucans as markers of microbiological contamination - characteristics, detection, and environmental exposure
Autorzy:
Lawniczek-Walczyk, A
Gorny, R.L.
Powiązania:
https://bibliotekanauki.pl/articles/49660.pdf
Data publikacji:
2010
Wydawca:
Instytut Medycyny Wsi
Tematy:
environmental exposure
endotoxin
beta-glucan
structure
biological activity
detection
microbiological contamination
environment pollution
hygienic standard
standard
Polish standard
occupational exposure
Źródło:
Annals of Agricultural and Environmental Medicine; 2010, 17, 2; 193-208
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena czystosci mikrobiologicznej powietrza w rejonie oddzialywania oczszczalni sciekow w Chociwlu
Autorzy:
Hawrot-Paw, M
Jachura, A.
Powiązania:
https://bibliotekanauki.pl/articles/808028.pdf
Data publikacji:
2006
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
oczyszczalnia sciekow w Chociwlu
oczyszczalnie sciekow
zanieczyszczenia mikrobiologiczne
zanieczyszczenia powietrza
emisja zanieczyszczen
scieki komunalne
tereny przylegle
Sewage Treatment Plant in Chociwel
Chociwel settlement
microbiological pollutant
air pollution
pollutant emission
municipal sewage
surrounding area
Opis:
W prezentowanej pracy oceniano stopień zanieczyszczenia mikrobiologicznego powietrza w strefie emisji mechaniczno-biologicznej oczyszczalni ścieków w Chociwlu k/Stargardu Szczecińskiego. Próbki powietrza atmosferycznego do badań pobierano w 8 punktach pomiarowych zlokalizowanych na obszarze oczyszczalni ścieków i w odległości do 120 m od „biobloków”. Pomiary wykonywano w latach 2005 - 2006. Próby powietrza do badań mikrobiologicznych pobierano metodę sedymentacyjną. W ramach badań oznaczano ogólną liczebność bakterii, promieniowców, bakterii Pseudomonas fluorescens oraz liczebność grzybów. Stopień zanieczyszczenia powietrza atmosferycznego oceniano w oparciu o Polskie Normy - PN-89/Z04111/02 i 03. Dodatkowo określano liczebność bakterii Escherichia coli. Wszystkie oznaczenia wykonywano w trzech powtórzeniach. Oceniając wpływ oczyszczalni ścieków na mikrobiologiczną jakość powietrza atmosferycznego stwierdzono, że liczebność badanych grup drobnoustrojów zmieniała się w czasie i w przestrzeni. Pod względem bakteriologicznym powietrze na terenie oczyszczalni oraz na obszarze wokół obiektu określono jako silnie zanieczyszczone, przy czym istotny wpływ na ocenę miała stosunkowo wysoka - w porównaniu z normą - liczebność promieniowców (średnio 276 jtk w 1 m³ powietrza przy komorach napowietrzania i 178 jtk·m⁻³ w odległości do 120 m.). Oznaczona w badaniach liczebność grzybów klasyfikowała powietrze jako wolne od zanieczyszczeń, niezagrażające człowiekowi i środowisku naturalnemu (niezależnie od pory roku i odległości od źródła emisji). Obecność bakterii Escherichia coli, uważanych za wskaźnik zanieczyszczenia sanitarnego powietrza, stwierdzono jedynie na terenie oczyszczalni ścieków, wokół emitorów bioaerozoli.
The paper presents the evaluation of air microbial pollution level in the area of mechanical-biological sewage treatment plant in Chociwel near Stargard Szczeciński. Samples of atmospheric air were taken for determinations at 8 measurement points within the sewage treatment plant and at the distance of 120 m away from the „bio-blocks”. The determinations were made in 2005 - 2006. Air samples for microbial assays were taken by the means of sedimentation method. The total number of bacteria, actinomycetes, Pseudomonas fluorescens bacteria and fungi were determined. The level of atmospheric air pollution was evaluated on the base of Polish Norms - PN-89/Z04111/02 and PN-89/Z04111/03. In addition, a number of Escherichia coli bacteria was assessed. All determinations were made in three replications. The evaluation of the sewage treatment plant influence on microbial quality of air revealed that a number of determined microorganisms varied in time and space. In bacteriological aspect, the air within sewage treatment plant and around was considered as strongly polluted, but relatively high - as compared to the norm - number of actinomycetes (276 cfu in 1 m³ of air at aeration chambers and 178 cfu per m³ at the distance of 120 m) had a significant influence on the evaluation. The number of determined fungi classified the air as free from pollution the not hazardous to the man and natural environment (regardless the season and distance from the emission source). The presence of Escherichia coli bacteria considered as an indicator of air sanitary pollution was found only in the area of sewage treatment plant around the bio-aerosols emitters.
Źródło:
Zeszyty Problemowe Postępów Nauk Rolniczych; 2006, 515; 113-119
0084-5477
Pojawia się w:
Zeszyty Problemowe Postępów Nauk Rolniczych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbial and chemical quality assessment of the small rivers entering the South Baltic. Part II : Case study on the watercourses in the Puck Bay catchment area
Mikrobiologiczna i chemiczna ocena jakości małych rzek uchodzących do Południowego Bałtyku. Część II : Analiza cieków wodnych w zlewni Zatoki Puckiej
Autorzy:
Bączkowska, Emilia
Kalinowska, Agnieszka
Ronda, Oskar
Bray, Rafał
Płóciennik, Bartosz
Polkowska, Żaneta
Powiązania:
https://bibliotekanauki.pl/articles/2173784.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Baltic Sea
water pollution
coastal rivers
microbiological quality monitoring
chemical quality monitoring
fecal coliforms
coastal management
morze Bałtyckie
zanieczyszczenie wody
rzeki przybrzeżne
monitorowanie jakości mikrobiologicznej
monitorowanie jakości chemicznej
bakterie coli w kale
zarządzanie wybrzeżem
Opis:
Due to its location, Puck Bay is an area particularly vulnerable to pollution of anthropogenic origin. The aim of the study was to assess the water quality of small watercourses entering the inner part of Puck Bay. The paper presents the results of chemical and microbiological analyses of 10 rivers and canals at their estuaries located on the western shore of the internal Puck Bay. The following environmental parameters were analyzed: conductivity, pH, dissolved oxygen concentration (in situ measurements), COD (cuvette tests), concentrations of ions (ion chromatography). Microbiological analysis included assessment of sanitary condition based on the number of fecal coliforms by a cultivation method. The determination of basic microbiological parameters such as: prokaryotic cell abundance expressed as total cells number (TCN), prokaryotic cell biovolume expressed as average cell volume (ACV), the prokaryotic biomass (PB) and prokaryotic cell morphotype diversity were determined using epifluorescence microscopy method. Based on the obtained results, it was found that small watercourses may carry a notable load of anthropogenic pollution and thus affect the environment of Puck Bay. The results clearly indicate the need for quality monitoring in the rivers and canals in the Coastal Landscape Park, flowing into Puck Bay. The research showed that also smaller watercourses may have an impact on the coastal waters’ state, and thus on the Baltic Sea water quality.
Zatoka Pucka, ze względu na swoje położenie, jest obszarem szczególnie narażonym na zanieczyszczenia pochodzenia antropogenicznego. Celem pracy była ocena jakości wód małych cieków wodnych uchodzących do wewnętrznej części Zatoki Puckiej. W pracy przedstawiono wyniki analiz chemicznych i mikrobiologicznych 10 rzek i kanałów w ujściach zlokalizowanych na zachodnim brzegu wewnętrznej Zatoki Puckiej. Analizie poddano następujące parametry środowiskowe: przewodność, pH, stężenie tlenu rozpuszczonego (pomiary in situ), ChZT (testy kuwetowe), stężenie jonów (chromatografia jonowa). Analiza mikrobiologiczna obejmowała ocenę stanu sanitarnego na podstawie liczby bakterii grupy coli typu kałowego metodą hodowlaną. Oznaczenia parametrów mikrobiologicznych takich jak: liczebność komórek prokariotycznych, średnia objętość komórek, biomasa oraz zróżnicowanie morfotypowe komórek prokariotycznych określono metodą mikroskopii epifluorescencyjnej. Na podstawie uzyskanych wyników stwierdzono, że małe cieki mogą przenosić znaczny ładunek zanieczyszczeń antropogenicznych i tym samym wpływać na środowisko Zatoki Puckiej. Uzyskane wyniki jednoznacznie wskazują na potrzebę prowadzenia monitoringu jakości rzek i kanałów w Nadmorskim Parku Krajobrazowym uchodzących do Zatoki Puckiej. Z badań wynika, że również mniejsze cieki mogą mieć wpływ na stan wód przybrzeżnych, a tym samym na jakość wód Morza Bałtyckiego.
Źródło:
Archives of Environmental Protection; 2022, 48, 1; 58--74
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies