Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "micro-channel" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
PIV analysis of turbulent flow in a micro-channel
Analiza przepływu turbulentnego w mikro-kanale przy wykorzystaniu cyfrowej anemometrii obrazowej
Autorzy:
Błoński, S.
Kowalewski, T. A.
Powiązania:
https://bibliotekanauki.pl/articles/279173.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
micro-channel
micro-PIV
turbulence
Opis:
Turbulent flow of water in a short 0.4 mm high micro-channel of an emulsifier is investigated experimentally using a micro-PIV technique and compared with numerical predictions. The micro-flow measurements are based on epi-fluorescence illumination and high-speed imaging. Velocity fields obtained from the measurements and direct numerical simulations indicate that flow turbulization is delayed and develops only at the outlet region of the micro-channel.
W pracy przedstawiono analizę turbulentnego przepływu wody przez mikro-kanał emulsyfikatora. Wyniki uzyskane eksperymentalną techniką Cyfrowej Anemometrii Obrazowej (PIV - Particle Image Velocimetry) zaadoptowanej do pomiarów w mikroskali (micro-PIV) porównano z wynikami symulacji numerycznych przeprowadzonych zarówno poprzez bezpośrednie rozwiązanie równań Naviera-Stokesa (DNS - Direct Numerical Simulation), jak i wykorzystując hipotezę Reynoldsa uśredniającą fluktuacje prędkości i ciśnienia (model k-...). Część eksperymentalna pracy przeprowadzona została na unikalnym stanowisku pomiarowym bazującym na mikroskopii epifluorescencyjnej i szybkim obrazowaniu analizowanego przepływu. Charakterystyki przepływu wyznaczone eksperymentalnie i numerycznie symulacją DNS wykazały, że turbulizacja przepływu pojawia się dopiero w końcowym przekroju mikro-kanału, osiągając maksimum w kanale wylotowym emulsyfikatora.
Źródło:
Journal of Theoretical and Applied Mechanics; 2007, 45, 3; 489-503
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Boiling in micro-channels
Autorzy:
Hetsroni, G.
Powiązania:
https://bibliotekanauki.pl/articles/199886.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
micro-channel
boiling
pressure drop
heat transfer
fluctuation
Opis:
Boiling heat transfer in micro-channels is a subject of intense academic and practical interest. Though many heat transfer correlations have been proposed, most were empirically formulated from experimental data. However, hydrodynamic and thermal aspects of boiling in micro-channels are not well understood. Moreover, there are only a few theoretical models that link the heat transfer mechanism with flow regimes in micro-channels. Also, there are discrepancies between different sets of published results, and heat transfer coefficients have either well exceeded, or fallen far below, those predicted for conventional channels. Here we consider these problems with regard to micro-channels with hydraulic diameters ranging roughly from 5 ěm to 500 ěm, to gain a better understanding of the distinct properties of the measurement techniques and uncertainties, the conditions under which the experimental results should be compared to analytical or numerical predictions, boiling phenomenon, as well as different types of micro-channel heat sinks. Two-phase flow maps and heat transfer prediction methods for vaporization in macro-channels are not applicable in micro-channels, because surface tension dominates the phenomena, rather than gravity forces. The models of convection boiling should correlate the frequencies, sizes and velocities of the bubbles and the coalescence processes, which control the flow pattern transitions, together with the heat flux and the mass flux. Therefore, the vapour bubble size distribution must be taken into account. The flow pattern in parallel micro-channels is quite different from that in a single micro-channel. At same values of heat and mass flux, different, time dependent, flow regimes occur in a given micro-channel. At low vapour quality, heat flux causes a sudden release of energy into the vapour bubble, which grows rapidly and occupies the entire channel cross section. The rapid bubble growth pushes the liquid-vapour interface on both caps of the vapour bubble, at the upstream and the downstream ends, and leads to a reverse flow. We term this phenomenon as explosive boiling. One of the limiting operating conditions with flow boiling is the critical heat flux (CHF). The CHF phenomenon is different from that observed in conventional size channels.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2010, 58, 1; 155-163
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examination of Different Heat Exchangers and the Thermal Activities of Different Designs
Autorzy:
Ipek, O.
Kan, M.
Gurel, B.
Powiązania:
https://bibliotekanauki.pl/articles/1031281.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
heat exchangers
compact heat exchanger
micro channel heat exchanger
Opis:
In this study, instead of gasketed or brazed plate heat exchangers, which are used in various fields of application, a direct metal sintering method is used to design a heat exchanger with its original geometry and with different geometries. Studies of heat exchangers found in published literature were reviewed, and the thermal behaviors of the proposed unique designs were examined. Usually heat exchangers using this design do not use channel spacing angles of 30-45-60-75° for the plate ducts. The thermal behaviors of the fluid-circulating systems were analyzed using ANSYS FLUENT software, and they used the boundary conditions found in the literature for this design. Heat transfer between the heat exchanger channels and channel walls was calculated. The analyses results show that an increase in the amount of heat transfer surface area and also an increase in surface roughness increased the amount of positive heat transfer.
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 580-584
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studium nad łączeniem mikro kanalikowych wymienników ciepła w wymiennik integralny
Studies on the Micro Heat Exchangers Coupling into Integral Heat Exchanger
Autorzy:
Kaczmarczyk, O.
Mikielewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/1818558.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
mikro kanalikowy wymiennik ciepła
sieć wymienników
ORC
micro channel heat exchanger
heat exchangers grid
Opis:
As it is commonly known, heat exchangers are widely used in power generators equipment. The biggest disadvantage of conventional heat exchangers is that, in case of the energy load variation, it must be replaced by the one of different size. The aim of this work is to specify a method of combining micro channel heat exchangers into a grid, realising different powers. It was ment to specify the most accurate micro channel heat exchangers connection, in order to increase the intensity of the heat exchange process. Studied problem was about heating the ORC working medium (R134a) using waste heat (hot water). In this paper, there has been studied the fenomenon of the heat exchange process in the micro channel heat exchanger grid, which will be further called the integral heat exchanger. There have been studied three cases of micro channel heat exchangers connections, such as: parallel-parallel, parallel (heating water)-serial (R134a) and parallel (R134a) – serial (heating water). On the basis of the results of the analytical analysis it has been stated, that the serial (heating water)-parallel (R134a 7) micro channel heat exchangers combination is the most suitable for the most intensive heat exchange.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 1; 485-506
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel approach to enhance performance of multilayer coated carbide insert in hard turning
Nowe podejście do poprawy osiągów w toczeniu na twardo przy użyciu wielowarstwowej płytki z ceramiki narzędziowej
Autorzy:
Shihab, S. K.
Khan, Z. A.
Siddiquee, A. N.
Khan, N. Z.
Powiązania:
https://bibliotekanauki.pl/articles/140027.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hard turning
flank wear
Taguchi approach
multi-coated carbide
micro-channel
toczenie na twardo
zużycie krawędzi
podejście Taguchi
węglik wielowarstwowy
mikrokanał
Opis:
Flank wear of multilayer coated carbide (TiN/TiCN/Al2O3/TiN) insert in dry hard turning is studied. Machining under wet condition is also performed and flank wear is measured. A novel micro-channel is devised in the insert to deliver the cutting fluid directly at the tool-chip interface. Lower levels of cutting parameters yield the minimum flank wear which is significantly affected by cutting speed and feed rate. In comparison to dry and wet machining, insert with micro-channel reduces the flank wear by 48.87% and 3.04% respectively. The tool with micro-channel provides saving of about 87.5% in the consumption of volume of cutting fluid and energy.
W pracy przedstawiono badania nad zużyciem krawędzi skrawającej wielowarstwowej płytki z ceramiki narzędziowej (TiN/TiCN/Al2O3/TiN) w toczeniu twardym na sucho. Badano także zużycie krawędzi skrawającej w warunkach toczenia na mokro. Nowatorskim rozwiązaniem było zastosowanie mikrokanału w płytce skrawającej, przez który płyn smarny dostarczany jest bezpośrednio do styku między narzędziem i wiórem. Uzyskany tą drogą niższy poziom parametrów skrawania zapewnia minimalne zużycie krawędzi skrawającej, na które w istotny sposób wpływają prędkość skrawania i szybkość posuwu. W porównaniu do warunków toczenia na sucho i na mokro, zastosowanie mikrokanału zmniejsza zużycie krawędzi skrawającej o odpowiednio 48,87% i 3,04%. Narzędzie z mikrokanałem zapewnia także oszczędność zużycia płynu smarnego i energii o ok. 87,5%.
Źródło:
Archive of Mechanical Engineering; 2015, LXII, 4; 539-552
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies