Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "metody inżynierskie" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Sound power level estimation - choice of the prior distribution
Autorzy:
Stępień, Bartłomiej
Powiązania:
https://bibliotekanauki.pl/articles/24201994.pdf
Data publikacji:
2023
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
sound power level
engineering methods
Bayesian statistics
prior distribution
poziom mocy akustycznej
metody inżynierskie
statystyka bayesowska
rozkład a priori
Opis:
Bayesian inference is one of the methods used to determine the sound power level of sound sources. This method requires knowledge of two probability distributions. The first is the sampling density, while the second is the prior distribution. In this study, the effect of the prior distribution on the sound power level estimation results was investigated. For this purpose, three prior distributions were used: 1) a normal distribution, 2) a distribution determined using the kernel density estimator, 3) a uniform distribution. The sound power level results determined by the engineering method were used to illustrate the proposed solutions and carry out the analysis. The results of the experiment were compared with the results of the sound power level determined using the precision method in the hemi-anechoic room according to ISO 3745:2012. The statistical inference has been carried out based on results of non-parametric statistical tests at the significance level α = 0.05.
Źródło:
Vibrations in Physical Systems; 2023, 34, 1; art. no. 2023110
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zapobieganie pożarom za granicą
Fire Prevention Abroad
Autorzy:
Ratajczak, D.
Powiązania:
https://bibliotekanauki.pl/articles/372956.pdf
Data publikacji:
2013
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
dyrektywa budowlana
rozporządzenie budowlane
bezpieczeństwo pożarowe budynków
metody inżynierskie
ewakuacja
hydranty wewnętrzne
okresowe kontrole budynków
construction products directive
construction products regulation
fire safety of buildings
engineering methods
evacuation
indoor hydrants
periodic inspections of buildings
Opis:
W artykule przedstawiono zagadnienia związane z konsekwencjami wejścia w życie Rozporządzenia Parlamentu Europejskiego i Rady (UE) Nr 305/2011 z dnia 9 marca 2011 r. ustanawiającego zharmonizowane warunki wprowadzania do obrotu wyrobów budowlanych i uchylającego dyrektywę Rady 89/106/EWG dla obowiązujących w Polsce przepisów dotyczących bezpieczeństwa pożarowego budynków. Ponieważ przepisy unijnego rozporządzenia są zgodne z rozwiązaniami stosowanymi od lat w Europie Zachodniej, natomiast Polska musi się do nich dostosować, autor wskazał te najważniejsze rozwiązania, które w zaistniałej sytuacji powinny być w naszym kraju zaadaptowane. Kluczowa jest tu kwestia wyraźnego rozgraniczenia w przepisach sytuacji, w których zapewnia się użytkownikom budynków możliwość ewakuacji w przypadku pożaru, od takich, gdzie ludzie mają zapewnione przetrwanie pożaru w bezpiecznej części budynku. Wymaganie rozporządzenia unijnego, aby konstrukcja budynku zachowała w razie pożaru nośność przez dający się określić czas, wystarczający do zapewnienia możliwości opuszczenia budynku przez ludzi i uwzględniający bezpieczeństwo ekip ratowniczych, znacząco ogranicza zbyt szeroki w Polsce zakres stosowania budynków klasy „E” odporności pożarowej, których konstrukcja nośna nie musi mieć zapewnionej żadnej klasy odporności ogniowej. W państwach Unii duży nacisk kładzie się na działania użytkowników obiektów po wykryciu pożaru, prowadzących do ograniczenia jego rozwoju, jeszcze przed przybyciem ekip ratowniczych z zewnątrz. Niezbędna do tego jest możliwość korzystania z łatwych w użyciu hydrantów wewnętrznych z wężem półsztywnym. W coraz większej liczbie państw przepisy techniczno-budowlane formułowane są w sposób umożliwiający szerokie stosowanie metod inżynierskich. Metody te pozwalają na najlepsze dopasowanie rozwiązań stosowanych w budynku do potrzeb związanych z bezpieczeństwem, a doskonalsze dopasowanie oznacza niższe koszty inwestycji. Unijne rozporządzenie budowlane zawiera obowiązek zachowywania podstawowych wymagań dla budynków, w tym bezpieczeństwa pożarowego, przez cały okres ich użytkowania. Sprawdzeniu realizacji tego obowiązku służą okresowe kontrole budynków, które w Polsce należało by rozszerzyć o powszechne kontrole spełniania wymagań bezpieczeństwa pożarowego budynków, gdyż aktualnie są one realizowane jedynie w bardzo niewielkim zakresie.
This article describes questions related to coming into force of Regulation (EU) No 305/2011 of The European Parliament and The Council of 9 March 2011 laying down harmonized conditions for the marketing of construction products and repealing Council Directive 89/106/EEC, for existing in Poland regulations on fire safety of buildings. The provisions of the EU Regulation are in accordance with the solutions being used for many years in Western Europe, however, Poland has to start adjusting them, that is why the author pointed out the significant improvements that need to be adapted in our country in this situation. The key issue indicated in the provisions is a clear distinction between two situations: when in case of fire a possibility for people to escape from buildings is provided, and when people are enabled to survive fire in a safe part of the building. The requirement of the EU Regulation that the structure of the building needs to keep load capacity during fire by certain time frame sufficiently enough to ensure the opportunity to leave the building by the people and taking into account the safety of rescue teams significantly reduces too wide scope of building with class ‘E’ fire resistance set in Poland, in which the supporting construction do not need to have any fire resistance category. In the EU, the emphasis is placed on the action taken by the building users after fire is detected, leading to a reduction of fire spreading, even before the arrival of rescue teams. The possibility to use user-friendly indoor hydrants with semirigid hose is essential. Nowadays in many countries technical and building regulations are formulated in such a way that benefits from widespread use of engineering methods. These methods allow the best solutions being fit to the buildings to meet the security standards and this also means lower investment costs. The EU Construction Products Regulation contains obligation to remain the basic requirements for buildings, including fire safety requirements throughout their usage time. Periodic inspections of buildings check if these requirements are fulfilled; however, in Poland there is a need to extend this control with general inspections checking fulfilment of the requirements of fire safety of buildings, as they are currently implemented only to a very limited extent.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2013, 3; 11-15
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obliczanie czasu bufora projektu w harmonogramach jednopunktowych z ujemną zwłoką na relacjach typu ZR między zadaniami
How to calculate project buffer time in PDM diagram with negative lag in FS relationship types between tasks
Autorzy:
Polonski, M.
Powiązania:
https://bibliotekanauki.pl/articles/886325.pdf
Data publikacji:
2011
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
obiekty inzynierskie
harmonogramy prac
planowanie
metody planowania
sieci jednopunktowe
bufory czasu
Źródło:
Scientific Review Engineering and Environmental Sciences; 2011, 20, 3[53]
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody monitoringu osuwisk i wczesnego ostrzegania on-line na przykładzie badań geologiczno-inżynierskich w Beskidzie Niskim i Średnim
Landslide monitoring and on-line early warning methods based on geological engineering investigations in the Beskid Niski and Beskid Średni Mountains
Autorzy:
Bednarczyk, Z.
Powiązania:
https://bibliotekanauki.pl/articles/2075322.pdf
Data publikacji:
2015
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
metody monitoringu osuwisk
badania geologiczno-inżynierskie
stabilizacja osuwiska
landslide monitoring systems
engineering geology investigations
landslide stabilization
Opis:
The objective of this paper is to presents results and conclusions from landslide monitoring and early warning methods implemented by the author for road and infrastructure stabilization projects. Research present monitoring for 23 Carpathian landslides and 8 counteraction projects. Implemented instrumentation besides standard monitoring methods included automatic on-line measurements with real-time transfer of landslide data to the Internet. The initial site investigations were funded under the Landslide Counteraction Project (2005–2009). Standard monitoring measurements was financed by author and Poltegor-Institute (2006–2015). Real-time measurements were realized inside the EU Innovative Economy Programme (2008–2013). These measurements are conducted and financed by the author till now. The instrumentation consists of 26 standard inclinometers to depths of 5–21 m. Up to Fifty five series of measurements performed 4–9 times a year from 2006 till now detected displacement from several millimetres to 49 cm. These were observed at depths of 1–17 m. Modern automatic, early warning, real time system was installed in May 2010. The system is the first of its kind in Poland and one of several such a systems in the world. The installation was carried out in consultation with the Local Road Authority in Gorlice. It contained three automatic field stations investigating landslide parameters to the depths of 12–16 m and the weather station. The displacements were measured by in-place inclinometers, and innovative 3D continuous inclinometer systems with sensors located every 0.5 m. It has possibility to measure much greater range of movements compare to the standard systems. The obtained data allowed better recognition of geohazards triggering parameters and control of landslide stabilization works. It included definition of risk conditions. The early-warning about the risk to the road owner and the Carpathian Branch of Polish Geological Survey were implemented. Chosen monitoring methods and numerical modelling could help in forecasting of the landslide movement for estimation of remediation possibilities and improve effectiveness of stabilization works. However, landslide stabilization works are usully difficult and should be connected with control monitoring measurements.
Źródło:
Przegląd Geologiczny; 2015, 63, 10/3; 1220--1229
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies