Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "membrane air separation" wg kryterium: Temat


Wyświetlanie 1-13 z 13
Tytuł:
Technology of oxygen production in the membrane-cryogenic air separation system for a 600 MW oxy-type pulverized bed boiler
Autorzy:
Berdowska, S.
Skorek-Osikowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/240451.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kriogeniczny rozdział powietrza
membranowy separator
produkcja tlenu
cryogenic air separation
membrane air separation
oxygen production
Opis:
In this paper the results of the thermodynamic analysis of the oxy-combustion type pulverized bed boiler integrated with a hybrid, membrane-cryogenic oxygen separation installation are presented. For the calculations a 600 MW boiler with live steam parameters at 31.1 MPa /654.9[degrees]C and reheated steam at 6.15 MPa/672.4[degrees]C was chosen. In this paper the hybrid membrane-cryogenic technology as oxygen production unit for pulverized bed boiler was proposed. Such an installation consists of a membrane module and two cryogenic distillation columns. Models of these installations were built in the Aspen software. The energy intensity of the oxygen production process in the hybrid system was compared with the cryogenic technology. The analysis of the influence of membrane surface area on the energy intensity of the process of air separation as well as the influence of oxygen concentration at the inlet to the cryogenic installation on the energy intensity of a hybrid unit was performed.
Źródło:
Archives of Thermodynamics; 2012, 33, 3; 65-76
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza przydatności materiałów membranowych do procesu zatężania metanu z powietrza wentylacyjnego kopalń
The analysis of the suitability of membrane materials for the enrichment of methane from ventilation air
Autorzy:
Janusz-Cygan, Aleksandra
Tańczyk, Marek
Jaschik, Manfred
Jaschik, Jolanta
Wojdyła, Artur
Sołtys, Elżbieta
Powiązania:
https://bibliotekanauki.pl/articles/306064.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Instytut Inżynierii Chemicznej PAN
Tematy:
metan z powietrza wentylacyjnego kopalń (VAM)
separacja membranowa
membrany polimerowe
membrany nieorganiczne
membrany MMMs
ventilation air methane (VAM)
membrane separation
polymeric membranes
inorganic membranes
MMMs membranes
Opis:
Przeprowadzono analizę możliwości wykorzystania istniejących materiałów membranowych na potrzeby separacji metanu zawartego w mieszaninach gazowych. Wytypowano grupę materiałów, które potencjalnie można zastosować do procesów zatężania metanu z powietrza wentylacyjnego kopalń. Przeprowadzono także obliczenia symulacyjne procesu permeacji dla jednej wytypowanej membrany. Stwierdzono, że w procesie membranowym, wykorzystującym taką membranę, można uzyskać gaz wzbogacony o stężeniu metanu co najmniej 0,5%, które jest wystarczające z punktu widzenia produkcji użytecznego ciepła w autotermicznym reaktorze rewersyjnym.
An analysis of the possibilities of using existing membrane materials for the separation of methane contained gas mixtures was carried out. A group of materials was selected that could potentially be used for the recovery of methane from mine ventilation air. Simulation of the permeation process for the selected membrane were also carried out. It was found that in such a process the enriched stream containing at least 0.5 vol% of methane can be produced, which should ensure the heat recovery when fed to a thermal reverse-flow reactor.
Źródło:
Prace Naukowe Instytutu Inżynierii Chemicznej Polskiej Akademii Nauk; 2019, 23; 7-22
1509-0760
Pojawia się w:
Prace Naukowe Instytutu Inżynierii Chemicznej Polskiej Akademii Nauk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie separacji membranowej do zatężania metanu pochodzącego z powietrza wentylacyjnego kopalń
The enrichment of ventilation air methane by membrane separation
Autorzy:
Jaschik, M.
Tańczyk, M.
Wojdyła, A.
Janusz-Cygan, A.
Warmuziński, K.
Sołtys, E.
Powiązania:
https://bibliotekanauki.pl/articles/306112.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Instytut Inżynierii Chemicznej PAN
Tematy:
separacja membranowa
komercyjne moduły membranowe
metan z powietrza wentylacyjnego kopalń (VAM)
membrane separation
commercial membrane modules
ventilation air methane (VAM)
Opis:
Celem pracy było określenie możliwości zatężania metanu pochodzącego z powietrza wentylacyjnego kopalń w komercyjnych modułach membranowych firmy UBE. Przeprowadzono badania doświadczalne procesu separacji mieszaniny zawierającej 0,3% obj. metanu w azocie zarówno w instalacji jednostopniowej, jak i wielostopniowej. Dokonano doświadczalnej weryfikacji opracowanego modelu matematycznego procesu separacji membranowej. Stwierdzono, że uzyskanie dwukrotnego zatężania metanu wymaga zastosowania kaskady modułów membranowych pracującej pod dużymi ciśnieniami, sięgającymi 7 bar(a). Opracowany model matematyczny może służyć do obliczeń projektowych i optymalizacyjnych procesu membranowego zatężania metanu pochodzącego z powietrza wentylacyjnego.
The basic aim of this study was to analyze the possibility of using commercial membrane modules in the recovery of methane from ventilation air. Experimental investigations concerning the separation of gaseous mixture containing 0.3 vol.% of methane in nitrogen were carried out. However, no satisfactory increase in methane concentration was observed in the product in a single-step installation. Therefore, a multi-step membrane system was proposed with UMS-A5 module. It was found that the developed mathematical model can be used for design calculations and optimization in the enrichment of lean methane-nitrogen mixtures.
Źródło:
Prace Naukowe Instytutu Inżynierii Chemicznej Polskiej Akademii Nauk; 2017, 21; 5-17
1509-0760
Pojawia się w:
Prace Naukowe Instytutu Inżynierii Chemicznej Polskiej Akademii Nauk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air separation in PVTMS membrane module
Separacja powietrza w membranowym module PVTMS
Autorzy:
Kluziński, W.
Gierycz, P.
Powiązania:
https://bibliotekanauki.pl/articles/258132.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
separacja gazów
moduł membranowy
powietrze
poliwinylotrimetylosilan
gas separation
membrane module
air
polyvinyltrimethylsilane
Opis:
The air separation was carried out using Russian industrial (Kriogenmash) PVTMS membrane module. The investigations have been performed in a pilot plant scale installation especially designed for this purpose. The separation measurements have been done, at different pressure ratios, for four types of membrane module sets as follows: one membrane module; a set of two parallel membrane modules; a set of two serial membrane modules with permeate from the first one feeding the second module; and, a set of two serial membrane modules with retentate from the first one feeding the second module. Obtained separation results have been discussed from the point of view of efficiency and conditions of using PVTMS membrane modules for such purposes. The results have been also used for evaluation of quality and properties of the membrane module.
Przeprowadzono separację powietrza w rosyjskim, przemysłowym (Kriogenmash), membranowym module PVTMS, w półtechnicznej skali, na specjalnie zaprojektowanej do tego celu aparaturze. Pomiary wykonano dla różnych stosunków ciśnień i czterech różnych układów modułów membranowych: pojedynczego modułu, układu dwóch równolegle połączonych modułów, układu dwóch szeregowo połączonych modułów, w którym moduł drugi był zasilany permeatem z modułu pierwszego oraz układu dwóch szeregowo połączonych modułów, w którym moduł drugi był zasilany retentatem z modułu pierwszego. Otrzymane wyniki doświadczalne zostały przedyskutowane z punktu widzenia warunków stosowania modułów PVTMS oraz wydajności prowadzonych procesów separacji powietrza. Ponadto, posłużyły one do określenia własności i jakości badanych modułów membranowych.
Źródło:
Problemy Eksploatacji; 2008, 4; 101-112
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gas separation in MMK-PMP-ST and LAMBDA membrane module
Separacja gazów w membranowych modułach MMK-PMP-ST i LAMBDA
Autorzy:
Kluziński, W.
Gierycz, P.
Powiązania:
https://bibliotekanauki.pl/articles/257681.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
separacja
gaz
moduł membranowy
powietrze
azot
wodór
gas separation
membrane module
air
hydrogen
nitrogen
poly-4-methylopentane-1
Opis:
The air separation was carried out using two MMK-PMP-ST and one LAMBDA industrial (Institute of Chemical Fibers, Łódź, Poland) membrane modules. The investigations have been performed in a pilot plant scale installation especially designed for this purpose. The separation measurements have been done at pressure ratio equal to 0.1 and 0.2. An extra investigation, concerning the separation of the hydrogen, has been done using the LAMBDA module, for the hydrogen-nitrogen mixture. Obtained separation results have been discussed from the point of view of efficiency and conditions of using membrane modules for such purposes. The results have been also used for evaluation of quality and properties of the membrane modules.
Przeprowadzono separację powietrza w przemysłowych, membranowych modułach MMK-PMP-ST i LAMBDA (wyprodukowanych przez Instytut Włókien Chemicznych w Łodzi), w półtechnicznej skali, na specjalnie zaprojektowanej do tego celu aparaturze. Pomiary wykonano dla różnych stosunków ciśnień w dwóch modułach MMK-PMP-ST różniących się powierzchnią separacji i module LAMBDA. Moduł LAMBDA zastosowano dodatkowo do separacji wodoru z mieszaniny wodór-azot. Otrzymane wyniki doświadczalne zostały przedyskutowane z punktu widzenia warunków stosowania modułów MMK-PMP-ST i LAMBDA oraz wydajności prowadzonych procesów separacji powietrza i wodoru. Ponadto posłużyły one do określenia własności i jakości badanych modułów membranowych.
Źródło:
Problemy Eksploatacji; 2009, 3; 107-116
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the efficiency of the unit based on circulating fluidized bed boiler integrated with three-end high-temperature membrane for air separation
Analiza efektywności układu kotła cyrkulacyjnego typu oxy z membraną wysokotemperaturową typu three-end do separacji powietrza
Autorzy:
Kotowicz, J.
Balicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/172915.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kocioł fluidalny
membrana typu three-end
separacja powietrza
fluidized boiler
three-end membrane
air separation
Opis:
W artykule analizie poddano kocioł z cyrkulacyjnym złożem fluidalnym. Do spalania węgla brunatnego w kotle użyto tlenu wytworzonego w wysokotemperaturowej membranie typu three-end. Pokazano sposób określenia powierzchni membran oraz energochłonności procesu membranowej separacji powietrza. Sprawność termiczną kotła, energochłonność membranowej separacji powietrza i powierzchnię modułu membranowego wyznaczono w funkcji odzysku tlenu w membranie. Zaproponowano wykorzystanie azotu z instalacji separacji powietrza do suszenia węgla. Dla takiego wariantu również wyznaczono charakterystyki układu. Stwierdzono, że przy wykorzystaniu azotu do suszenia sprawności termicznej kotła rośnie z 76% do 87%, przy wzroście stopnia odzysku tlenu od 0,45 do 0,9, i jest wyższa odpowiednio od 12% do 6% w porównaniu do układu bez suszenia. W zaproponowanym układzie separacji powietrza powierzchnia modułu membranowego zawiera się w przedziale 76,5-95,0 tys. m².
In this paper boiler with circulating fluidized bed was analyzed. For the combustion of lignite in the boiler oxygen produced in the three-end high-temperature membrane was used. Paper shows a method of determining the surface of the membranes and energy consumption of the air separation process. Boiler thermal efficiency, energy consumption of the process and air separation membrane module surface was determined as a function of oxygen recovery in the membrane. Nitrogen from the air separation unit was proposed to be used for drying lignite. For this variant characteristics of the system were determined. It was found that the thermal efficiency of the boiler in case where nitrogen was used for lignite drying increased from 76% to 87% with increasing value of oxygen recovery ratio from 0.45 to 0.9 and is higher, respectively, from 12% to 6% in comparison to the system without drying. In the proposed air separation unit required membrane surface is in the range 76500-95000 m².
Źródło:
Archiwum Energetyki; 2012, 42, 2; 59-71
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of technical and economic parameters of an ionic transport membrane air separation unit working in a supercritical power plant
Autorzy:
Kotowicz, J.
Michalski, S.
Balicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/185699.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
four-end type ionic transport membrane module
air separation
supercritical power plant
separacja powietrza
elektrownia nadkrytyczna
Opis:
In this paper an air separation unit was analyzed. The unit consisted of: an ionic transport membrane contained in a four-end type module, an air compressor, an expander fed by gas that remains after oxygen separation and heat exchangers which heat the air and recirculated flue gas to the membrane operating temperature (850 °C). The air separation unit works in a power plant with electrical power equal to 600 MW. This power plant additionally consists of: an oxy-type pulverized-fuel boiler, a steam turbine unit and a carbon dioxide capture unit. Life steam parameters are 30 MPa/650 °C and reheated steam parameters are 6 MPa/670 °C. The listed units were analyzed. For constant electrical power of the power plant technical parameters of the air separation unit for two oxygen recovery rate (65% and 95%) were determined. One of such parameters is ionic membrane surface area. In this paper the formulated equation is presented. The remaining technical parameters of the air separation unit are, among others: heat exchange surface area, power of the air compressor, power of the expander and auxiliary power. Using the listed quantities, the economic parameters, such as costs of air separation unit and of individual components were determined. These quantities allowed to determine investment costs of construction of the air separation unit. In addition, they were compared with investment costs for the entire oxy-type power plant.
Źródło:
Chemical and Process Engineering; 2016, 37, 3; 359-371
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of selected parameters on the efficiency and economic charactersistics of the oxy-type coal unit with a membrane-cryogenic oxygen separator
Autorzy:
Kotowicz, J.
Berdowska, S.
Powiązania:
https://bibliotekanauki.pl/articles/240290.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
oxygen production
membrane air separation
produkcja tlenu
membranowy separator
Opis:
In this paper a 600 MW oxy-type coal unit with a pulverized bed boiler and a membrane-cryogenic oxygen separator and carbon capture installation was analyzed. A membrane-cryogenic oxygen separation installation consists of a membrane module and two cryogenic distillation columns. In this system oxygen is produced with the purity equal to 95%. Installation of carbon capture was based on the physical separation method and allows to reduce the CO2 emission by 90%. In this work the influence of the main parameter of the membrane process – the selectivity coefficient, on the efficiency of the coal unit was presented. The economic analysis with the use of the break-even point method was carried out. The economic calculations were realized in view of the break-even price of electricity depending on a coal unit availability.
Źródło:
Archives of Thermodynamics; 2016, 37, 1; 73-85
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamic evaluation of supercritical oxy-type power plant with high-temperature three-end membrane for air separation
Autorzy:
Kotowicz, J.
Balicki, A.
Michalski, S.
Powiązania:
https://bibliotekanauki.pl/articles/240116.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
oxy-combustion
membrane technology
air separation unit
thermodynamic evaluation
oxy-spalanie
technologie membranowe
separator powietrza
ocena termodynamiczna
Opis:
Among the technologies which allow to reduce greenhouse gas emissions, mainly of carbon dioxide, special attention deserves the idea of 'zero-emission' technology based on boilers working in oxy-combustion technology. In the paper a thermodynamic analysis of supercritical power plant fed by lignite was made. Power plant consists of: 600 MW steam power unit with live steam parameters of 650°C/30 MPa and reheated steam parameters of 670°C/6 MPa; circulating fluidized bed boiler working in oxy-combustion technology; air separation unit and installation of the carbon dioxide compression. Air separation unit is based on high temperature membrane working in three-end technology. Models of steam cycle, circulation fluidized bed boiler, air separation unit and carbon capture installation were made using commercial software. After integration of these models the net electricity generation efficiency as a function of the degree of oxygen recovery in high temperature membrane was analyzed.
Źródło:
Archives of Thermodynamics; 2014, 35, 3; 105-116
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical models of the air separation through polymer membranes at magnetic field
Autorzy:
Strzelewicz, A.
Grzywna, Z. J.
Powiązania:
https://bibliotekanauki.pl/articles/346951.pdf
Data publikacji:
2007
Wydawca:
Politechnika Bydgoska im. Jana i Jędrzeja Śniadeckich. Wydział Technologii i Inżynierii Chemicznej
Tematy:
diffusion
membrane
time lags
gas mixtures
air separation
Opis:
This paper is addressed to the membrane air separation i.e. the gas mixture of quite similar gases in many respects, except one: oxygen is paramagnetic whereas nitrogen is diamagnetic. This fact forms the basis for their separation. The numerical studies and theoretical predictions concerning the air membrane separation in the presence of a magnetic field are discussed. Some experimental data concerning the „magnetic membranes” i.e. ethylcellulose membranes with neodymium powder, are also presented.
Źródło:
Ars Separatoria Acta; 2007, 5; 34-44
1731-6340
Pojawia się w:
Ars Separatoria Acta
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Teoretyczna analiza zatężania metanu w powietrzu wentylacyjnym kopalń w procesach adsorpcji zmiennociśnieniowej i membranowym
Theoretical analysis of the enrichment of methane in ventilation air by pressure swing adsorption and membrane separation
Autorzy:
Tańczyk, M.
Jaschik, M.
Warmuziński, K.
Janusz-Cygan, A.
Jaschik, J.
Wojdyła, A.
Sołtys, E.
Powiązania:
https://bibliotekanauki.pl/articles/306110.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Instytut Inżynierii Chemicznej PAN
Tematy:
adsorpcja zmiennociśnieniowa
separacja membranowa
metan z powietrza wentylacyjnego kopalń (VAM)
pressure swing adsorption
membrane separation
ventilation air methane (VAM)
Opis:
Celem pracy było określenie, poprzez wielowariantowe obliczenia symulacyjne, możliwości zatężania metanu w mieszaninie z azotem w procesie adsorpcji zmiennociśnieniowej (PSA) i procesie membranowym. W przypadku procesu PSA, w którym adsorbentem był węgiel aktywny Takeda G2X7/12, określono zależność stężenia metanu w gazie wzbogaconym i sprawności odzysku CH4 od podstawowych parametrów ruchowych. Stwierdzono, że w symulowanym procesie można z bardzo dużą sprawnością odzysku (~90%) uzyskiwać strumień gazowy o stężeniu metanu wynoszącym około 1% obj., co umożliwia jego wykorzystanie w turbinach gazowych na paliwo ubogie. W przypadku procesu membranowego symulowano pracę modułu UBE CO-C05, określając zależność między stężeniem metanu, sprawnością jego odzysku, ciśnieniem po stronie zasilania i liczbą permeacji. Stwierdzono, że w module tym można uzyskać gaz wzbogacony o stężeniu metanu 0,5%, które jest wystarczające z punktu widzenia produkcji użytecznego ciepła w autotermicznym reaktorze rewersyjnym.
In this study the enrichment of methane in ventilation air by pressure swing adsorption (PSA) and by membrane separation was investigated theoretically. In the case of the PSA process, which uses Takeda G2X7/12 activated carbon, the impact of various process parameters on the concentration of CH4 in the enriched gas and methane recovery was determined. It was found that the PSA process can provide a gaseous stream containing ~1 vol. % of CH4 with a high methane recovery (~90%). Such a stream may be used in lean-fuel turbines. In the case of the membrane process the UBE CO-C05 module was used and the relationship between the concentration of methane and its recovery, the pressure of feed gas and the permeation number was determined. It was found that in such a process the enriched stream containing ~0.5 vol. % of methane can be produced, which should ensure the recovery of heat when fed to a thermal reverse-flow reactor.
Źródło:
Prace Naukowe Instytutu Inżynierii Chemicznej Polskiej Akademii Nauk; 2018, 22; 53-67
1509-0760
Pojawia się w:
Prace Naukowe Instytutu Inżynierii Chemicznej Polskiej Akademii Nauk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości zastosowania procesów adsorpcyjnych i membranowych do zatężania metanu pochodzącego z powietrza wentylacyjnego kopalń
Adsorption and membrane processes for the enrichment of methane in mine ventilation air
Autorzy:
Tańczyk, Marek
Janusz-Cygan, Aleksandra
Pawlaczyk-Kurek, Anna
Jaschik, Jolanta
Wojdyła, Artur
Sołtys, Elżbieta
Powiązania:
https://bibliotekanauki.pl/articles/27324063.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Instytut Inżynierii Chemicznej PAN
Tematy:
metan z powietrza wentylacyjnego kopalń
adsorpcja zmiennociśnieniowa
separacja membranowa
ventilation air methane (VAM)
pressure swing adsorption
membrane separation
Opis:
Przeprowadzono analizę metod adsorpcyjnych i membranowych pod kątem zatężania metanu w powietrzu wentylacyjnym kopalń (VAM). Stwierdzono, że możliwe jest zwiększenie stężenia VAM z 0,2-0,3% obj. do co najmniej 1% obj. przy wykorzystaniu obu technik separacyjnych, co powinno ułatwić jego utylizację w reaktorach rewersyjnych lub silnikach na paliwo ubogie.
Technologies for thermal utilization of ventilation air methane (VAM) require stabilization and/or increasing its concentration. This paper summarizes the results of research conducted at the IICh PAS in the area of adsorption and membrane processes for VAM enrichment. First of all adsorbents and membrane materials were selected and investigated for such processes. They were assessed in terms of CH4/N2 selectivity, as defined by Eqs 1 and 2, as well as adsorption capacity (adsorbents) and permeability (membranes). The properties of activated carbons and ZMS 5A investigated were presented in Table 1 and Fig. 1. In the case of membranes polyimide membranes, used in commercial UMS-A5 and CO-C05 UBE modules, as well as the Matrimid 5218/CMS composite membrane, were selected for membrane VAM enrichment process. The pressure swing adsorption process in two-bed (Fig. 2) and four-bed (Fig. 4) installations for VAM enrichment was also investigated. The process performance was presented in Fig. 3 and Figs 5-6, respectively. It has been found that in the case of the four-bed process with activated carbon G2X7/12 Takeda VAM can be enriched from 0.2 to over 1.2 vol.% with a recovery of at least 80%. The results of membrane VAM enrichment processes were summarized in Table 2. It was found that in the case of commercially available UBE modules UMS-A5 and CO-C05 the concentration of methane in VAM can be increased from 0.3 to 0.43 vol.% with moderate CH4 recovery (50-60%). Higher enrichment (up to 1,8 vol.% in a three-stage system) can be obtained in the case of the hybrid Matrimid 5218/CMS. For an assessment of the energy efficiency of the PSA and membrane enrichment processes two factors were defined: the unit power necessary to generate the pressure ratio pW/pN in the separation process (Eq. 3) and the unit heat output of the ventilation air (Eq. 4). These factors were presented in Fig. 7 along with unit thermal power of the enriched gas for the membrane (triangles) and adsorption (diamonds) VAM enrichment processes. It was found that regardless of the separation method and process parameters, the potential energy gain from the utilization of enriched VAM is much lower than the energy expenditure related to the implementation of the enrichment process, which is primarily due to the low unit thermal power of the ventilation air.
Źródło:
Prace Naukowe Instytutu Inżynierii Chemicznej Polskiej Akademii Nauk; 2022, 26; 17--36
1509-0760
Pojawia się w:
Prace Naukowe Instytutu Inżynierii Chemicznej Polskiej Akademii Nauk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania procesu rozdziału mieszaniny metan – azot w komercyjnych modułach membranowych
The study on the separation of methane–nitrogen mixtures in commercial membrane modules
Autorzy:
Warmuziński, K.
Jaschik, M.
Tańczyk, M.
Wojdyła, A.
Janusz-Cygan, A.
Sołtys, E.
Powiązania:
https://bibliotekanauki.pl/articles/306031.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Instytut Inżynierii Chemicznej PAN
Tematy:
separacja membranowa
komercyjne moduły membranowe
metan z powietrza wentylacyjnego kopalń
membrane separation
commercial membrane modules
ventilation air methane
Opis:
Zasadniczym celem badań było określenie przydatności dostępnych komercyjnie modułów membranowych w procesie wydzielania metanu z powietrza wentylacyjnego kopalń. Przeprowadzono doświadczalne badania procesu permeacji czystego metanu i azotu oraz mieszaniny tych gazów w trzech modułach membranowych. Istotnym wnioskiem płynącym z wykonanych prac jest fakt, że moduły firmy UBE mogłyby zostać wykorzystane do zatężania niskostężonej mieszaniny metan–azot.
The basic aim of this study was to analyze the possibility of using commercial membrane modules to the removal of CH4 from ventilation air methane (VAM). Experimental investigations concerning the permeation of pure gases (CH4, N2) and mixture of these gases, in three membrane modules, ware carried out. An important conclusion is that the UBE modules may successfully be used in the enrichment of dilute mixtures of methane and nitrogen.
Źródło:
Prace Naukowe Instytutu Inżynierii Chemicznej Polskiej Akademii Nauk; 2016, 20; 117-125
1509-0760
Pojawia się w:
Prace Naukowe Instytutu Inżynierii Chemicznej Polskiej Akademii Nauk
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-13 z 13

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies