Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "medium voltage insulation" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Monitoring of Partial Discharges in Cable Insulation and Cable Head Using Acoustic Method
Autorzy:
Ranachowski, Zbigniew
Wieczorek, Krzysztof
Ranachowski, Przemysław
Dębowski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2141672.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
partial discharges
medium voltage insulation
acoustic emission
Opis:
The article presents the application of Acoustic Emission (AE) method for detection and registration of partial discharges (PD) generated in medium voltage (MV) cable isolation and MV cable head. The insulation of the high voltage cable is made of a flexible material whose properties are characterised by a high coefficient of attenuation of the acoustic signals. For this reason, the AE method has not been used so far to detect PD in energetic cables. The subjects of the research were the MV cable and the standard T-type cable head. The cable contained defects which were the source of partial discharges. In case of cable head the PD were provoked by thin grounded electrode which was introduced into connector opening. The results of AE measurements are presented in the form of spectrograms. Acoustic Emission was evoked when the applied voltage level reached the value of 7.5 kV for the cable and 4 kV for the cable head. The authors used the acoustic instrumentation of their own design intended for future field use. Obtaining successful results of partial discharges measurements using the acoustic method in the cable insulation makes an original contribution of the presented work.
Źródło:
Archives of Acoustics; 2022, 47, 2; 259-265
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The modeling of non-homogenous structure of power cables insulation systems
Modelowanie niejednorodnej struktury układu izolacyjnego kabli elektroenergetycznych
Autorzy:
Adamczyk, B.
Florkowska, B.
Pędzisz, K.
Powiązania:
https://bibliotekanauki.pl/articles/266525.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
kable średniego napięcia
pole elektryczne
awaryjność
wyładowania niezupełne
procesy degradacji
medium voltage cables
electric field distribution
failure
partial discharges
insulation degradation
Opis:
Among exploitation stresses of power cables are electrical stresses, created by electric field strength in an insulation system. Insulation system of power cables typically has a non homogenous distribution of the electric field strength, where its maximum value is critical. Local defects in a structure of power cables influence the field distribution. Its value around defects can exceed the working electric field strength and initial field of partial discharge inception. The electric field strength in medium voltage cables with ethylene-propylene insulation are analyzed in the paper. Local defects similar to the exploitation ones were assumed as potential sources of partial discharges. The presented patterns of electric field strength illustrate the impact of the defect type and its localization in the insulation system on changes of field distribution and local field strength increase.
Do zespołu narażeń eksploatacyjnych kabli elektroenergetycznych należą narażenia elektryczne, jakie stanowi oddziaływanie pola elektrycznego w izolacji. Układ izolacyjny kabli charakteryzuje nierównomierny rozkład pola elektrycznego, którego wartość maksymalna oznacza robocze natężenia pola dla danej konstrukcji. Lokalne defekty w izolacji powodują, że jej struktura staje się niejednorodna, ulega zmianie rozkład pola elektrycznego. Jego wartość w otoczeniu defektów może przewyższyć natężenie robocze w kablu oraz natężenie początkowe wyładowań niezupełnych. W artykule przedstawiono analizę rozkładu pola elektrycznego w kablu średniego napięcia o izolacji etylenowo-propylenowej. Przyjęto warunki występowania w jego konstrukcji lokalnych defektów w izolacji, które w eksploatacji mogą stać się ośrodkami wyładowań niezupełnych. Przedstawiono obrazy pola elektrycznego ilustrujące wpływ rodzaju defektu i jego usytuowania w izolacji na zmiany rozkładu pola i lokalny wzrost jego wartości.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2010, 28; 27-30
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies