Wyszukujesz frazę "medical ultrasound" wg kryterium: Temat


Wyświetlanie 1-9 z 9
Tytuł:
Ultrasonic Measurement of Temperature Rise in Breast Cyst and in Neighbouring Tissues as a Method of Tissue Differentiation
Autorzy:
Gambin, B.
Byra, M.
Kruglenko, E.
Doubrovina, O.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/177465.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
medical ultrasound
temperature changes in vivo
breast tissue
ultrasonic temperature measurement
Opis:
Texture of ultrasound images contain information about the properties of examined tissues. The analysis of statistical properties of backscattered ultrasonic echoes has been recently successfully applied to differentiate healthy breast tissue from the benign and malignant lesions. We propose a novel procedure of tissue characterization based on acquiring backscattered echoes from the heated breast. We have proved that the temperature increase inside the breast modifies the intensity, spectrum of the backscattered signals and the probability density function of envelope samples. We discuss the differences in probability density functions in two types of tissue regions, e.g. cysts and the surrounding glandular tissue regions. Independently, Pennes bioheat equation in heterogeneous breast tissue was used to describe the heating process. We applied the finite element method to solve this equation. Results have been compared with the ultrasonic predictions of the temperature distribution. The results confirm the possibility of distinguishing the differences in thermal and acoustical properties of breast cyst and surrounding glandular tissues.
Źródło:
Archives of Acoustics; 2016, 41, 4; 791-798
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aspects of Applicability King - St. Clair Approximation in a Non-Newtonian Fluid Mechanics
Autorzy:
Włoch, A.
Czyż, H.
Jasiński, T.
Powiązania:
https://bibliotekanauki.pl/articles/1032505.pdf
Data publikacji:
2017-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
acoustic radiation force
acoustic standing wave
medical applications of ultrasound
separation of red blood cells from human blood
Opis:
This studyis a contribution to research on the biomedical and clinical applications of ultrasound. Our research concerns the procedure for the separation of human blood fractions - erythrocytes. Ultrasonic waves can be used for the separation of cells in human blood. From a physical point of view, the human blood is a suspension of liquids and solids (cell elements), and behaves like a non-Newtonian fluid. Our work is devoted to the problem of the motion of red cells in human blood under the influence of ultrasonic wave. It defines a range of the applicability of approximation consisting in neglecting the nonlinear term in the friction force. It also analyzes the general properties of the equation of motion of the cell in the case of large attenuation constants, corresponding to the values of the drift forces for the cells with radii of a few μm. Finally, it defines the applicability criterion of the so-called King-St Clair approximation consisting in the assumption of equilibrium between the drift and the Stokes viscosity forces, neglecting the term representing inertia. This approximation permits analytical estimation of the time constants for the cell transport to points of stable equilibrium in an ultrasonic standing wave field.
Źródło:
Acta Physica Polonica A; 2017, 132, 1; 164-166
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Opinie ratowników medycznych o możliwości wykorzystania badania ultrasonograficznego w zespołach ratownictwa medycznego
Opinions of medical rescuers on the possibility of using ultrasound in medical rescue teams
Autorzy:
Bujnowska, Małgorzata
Zakrzewska-Blusiewicz, Monika
Powiązania:
https://bibliotekanauki.pl/articles/473106.pdf
Data publikacji:
2017-09-01
Wydawca:
Collegium Witelona Uczelnia Państwowa
Tematy:
ultrasonografia
ratownictwo medyczne
ultrasound
medical emergency
Opis:
Badanie ultrasonograficzne w diagnostyce przedszpitalnej w Polsce jest właściwie niewykorzystywane ze względu na brak odpowiednich aktów prawnych zobowiązujących do posiadania aparatów USG w zespołach ratownictwa medycznego oraz ze względu na brak odpowiednich szkoleń. W USA oraz Europie Zachodniej USG standardowo wykorzystuje się w celu identyfikacji i diagnostyki odwracalnych przyczyn zatrzymania krążenia. Celem pracy była analiza przydatności badania ultrasonograficznego w warunkach przedszpitalnych na podstawie opinii ratowników medycznych pracujących w Zespołach Ratownictwa Medycznego. Do badań włączono 68 ratowników medycznych pracujących w pięciu stacjach pogotowia ratunkowego. Badania przeprowadzono za pomocą autorskiej ankiety. Wyniki pokazują, że ratownicy medyczni byliby skłonni do podjęcia szkolenia w zakresie protokołów ultrasonograficznych przydatnych w medycynie ratunkowej jedynie w sytuacji pozyskania na ten cel środków zewnętrznych. Za przydatne w ocenie ultrasonograficznej uznali cztery elementy składające się na badanie w protokole eFAST: ujawnienie płynu w jamie otrzewnowej oraz jamach opłucnowych, potwierdzenie odmy opłucnowej i ujawnienie wolnego płynu w worku osierdziowym (tamponady osierdzia). Elementy badania echokardiograficznego ( protokoły FATE, FEEL) zostały uznane za nieprzydatne, podobnie jak potwierdzenie za pomocą ultrasonografii położenia rurki intubacyjnej i teletransmisja obrazów ultrasonograficznych.
Ultrasound diagnosis in pre-hospital treatment in Poland is virtually non-existent because of the lack of relevant legislation obliging emergency medical teams to have ultrasound pocket machines and due to the lack of proper training. In the US and Western Europe, USG is normally used for identification and diagnosis of reversible causes. The aim of this study was to evaluate the usefulness of ultrasound in pre-hospital treatment based on the results of a survey conducted among paramedics working in Medical Rescue Teams. The study included 68 medical rescuers working in five emergency stations. The study was conducted using a proprietary questionnaire. Conclusions. The results show that the paramedics would only be willing to undertake training in the field of ultrasound protocols useful in emergency medical treatment in the case of obtaining funds for that purpose from some external sources. They recognize four elements of the study protocol Efast, which include disclosure of fluid in the peritoneal and pleural cavities, confirmation of pneumothorax and disclosure of free fluid in the pericardial sac (pericardial tamponade), to be useful for ultrasound evaluation. Echocardiographic elements (FATE and FEEL protocols) are considered as useless, similarly to confirmation by ultrasound endotracheal tube position and telematics ultrasound images.
Źródło:
Zeszyty Naukowe Państwowej Wyższej Szkoły Zawodowej im. Witelona w Legnicy; 2017, 3, 24
1896-8333
Pojawia się w:
Zeszyty Naukowe Państwowej Wyższej Szkoły Zawodowej im. Witelona w Legnicy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Physics in medicine and economy of contemporary society
Fizyka w medycynie i gospodarce współczesnego społeczeństwa
Autorzy:
Czyż, H.
Jasiński, T.
Powiązania:
https://bibliotekanauki.pl/articles/129547.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
laws of physics
human blood
centrifugation
filtration
acoustic standing wave
medical applications of ultrasound
prawa fizyki
ludzka krew
separacja krwi ludzkiej
wirowanie
filtracja
akustyczna fala stojąca
medyczne zastosowania ultradźwięków
Opis:
This paper describes the main methods of separating blood into components. The most common methods used in medicinal practice include centrifugation and filtration. Currently, there has been a lot of research on the application of ultrasound as the new, innovative method of separation of blood components. Ultrasound use is a theoretically elaborated method and experimental research is in process with the aim of its implementation in medical diagnostics. Contemporary societies are aware of the importance of findings of physics as well as of the fact that our everyday life is strongly connected to physics and to technical devices that have been created on the basis of its fundamental laws.
Współczesne społeczeństwa są świadome znaczenia odkryć fizycznych dla gospodarki i medycyny. Nasze codzienne życie jest silnie związane z urządzeniami technicznymi, które zostały wytworzone na podstawie fundamentalnych praw fizyki. W pracy analizowano fizyczne metody rozdzielania krwi ludzkiej na składniki. Obecnie w praktyce medycznej najczęściej stosowanymi metodami są wirowanie i filtracja. Dokonując analizy podstaw fizycznych metod tradycyjnych separacji krwi na składniki, zaprezentowano także innowacyjną metodę, która wykorzystuje fale ultradźwiękowe o parametrach dobranych do parametrów składników krwi. Metoda ta jest teoretycznie opracowana, wymaga natomiast weryfikacji eksperymentalnej w celu wdrożenia jej w diagnostyce medycznej.
Źródło:
Physics for Economy; 2017, 1, 1; 5-13
2544-7742
2544-7750
Pojawia się w:
Physics for Economy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Novel robotic system for remote ultrasonography - from an idea to the first prototype. Presentation of the ReMeDi project
Nowy system robotyczny do zdalnej ultrasonografii - od pomysłu do pierwszego prototypu. Prezentacja projektu ReMeDi
Autorzy:
Szczęśniak-Stańczyk, D.
Stańczyk, B.
Powiązania:
https://bibliotekanauki.pl/articles/2063844.pdf
Data publikacji:
2015
Wydawca:
Międzynarodowe Stowarzyszenie na rzecz Robotyki Medycznej
Tematy:
diagnostyka medyczna
ultrasonografia
system robotyczny
robot medyczny
prototyp
ReMeDi
medical diagnostics
ultrasound
robotic system
medical robot
prototype
Opis:
Nowadays the demand for specialized medical care becomes higher. Additionally increasing deficit of physician is observed in majority of countries worldwide. The solution for such a situation seems to be telemedicine. The ReMeDi project is aimed to developa robotic system for remote medical diagnostics, which can support physician by enhancing the (tele-) presence with intelligent cognitive autonomous features. This paper focuses on the interfaces of the ReMeDi system which are dedicated for remote ultrasonography and presents the work done during the two years of the project.
Zapotrzebowanie na specjalistyczną opiekę medyczną w dzisiejszych czasach staje się coraz większe. Dodatkowo obserwowany jest rosnący niedobór lekarz w większości krajów na całym świecie. Rozwiązaniem takiej sytuacji wydaje się być telemedycyna. Projekt ReMeDi ma na celu zbudowanie systemu robotycznego do zdalnej diagnostyki medycznej, który będzie wspierać lekarza poprzez umożliwienie zdalnej obecności przy wykorzystaniu inteligentnych i autonomicznych funkcji poznawczych. Ten artykuł skupia się na interfejsach systemu ReMeDi przeznaczonych do zdalnej ultrasonografii i prezentuje prace wykonane w ciągu dwóch lat trwania projektu.
Źródło:
Medical Robotics Reports; 2015, 4; 31--38
2299-7407
Pojawia się w:
Medical Robotics Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasound imaging in the general practitioner’s office – a literature review
Diagnostyka ultrasonograficzna w gabinecie lekarza rodzinnego – przegląd piśmiennictwa
Autorzy:
Genc, Alicja
Ryk, Małgorzata
Suwała, Magdalena
Żurakowska, Tatiana
Kosiak, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/1052776.pdf
Data publikacji:
2016
Wydawca:
Medical Communications
Tematy:
general practitioners
medical imaging
ultrasonography
ultrasound imaging
badanie obrazowe
diagnostyka ultrasonograficzna
lekarze rodzinni
ultrasonografia
Opis:
Ultrasound, which is a safe and non-invasive diagnostic modality that uses more and more advanced imaging techniques, has become the first-choice examination in various diseases. It is more and more often used in the general practitioner’s office to supplement physical examination and interview. Aim: The aim of this paper is to review the Polish medical literature pertaining to the usage of ultrasound imaging in general practice as well as to present advantages, disadvantages and utility associated with conducting ultrasound examinations by general practitioners based on selected publications. Material and methods: The analysis involved 15 articles found in Polish medical literature published in 1994–2013 in 9 medical journals. These publications were obtained using various data bases, such as Polish Medical Bibliography, Google Scholar as well as websites of “Lekarz Rodzinny” and “Ultrasonografia.” Results: Of 15 available publications, 5 papers present the usage of ultrasound imaging by a primary care physician for general purposes, 4 discuss the usage of abdominal scans, 3 – imaging of the neck and lymph nodes, 1 – lungs, and 2 discuss its usage for specific disease entities. In over 70% of the papers, the financial aspect associated with the usage of this modality in general practice is mentioned. More than a half of the publications draw attention to the possibility of using point-of-care ultrasound examinations. Advantages of ultrasonography most often mentioned by the authors include: good effects of screening, safety, short duration and low cost. The authors of eight publications also indicate disadvantages associated with ultrasound imaging used by a general practitioner. Conclusions: In the Polish literature, there are relatively few papers on the role of ultrasonography in the office of a primary care physician. This modality is more and more often becoming a tool that helps primary care physicians to establish diagnoses, accelerates the initiation of treatment and directs the further diagnostic process.
Ultrasonografia, będąca bezpieczną i nieinwazyjną metodą diagnostyczną, wykorzystującą coraz bardziej udoskonalone techniki obrazowania, stała się badaniem pierwszego wyboru w wielu schorzeniach. Coraz częściej stosowana jest w gabinecie lekarza rodzinnego jako metoda uzupełniająca badania podmiotowe i przedmiotowe. Cel: Celem pracy był przegląd piśmiennictwa polskiego opisującego wykorzystanie badania ultrasonograficznego w gabinecie lekarza rodzinnego oraz przedstawienie zalet, wad i przydatności wykonywania samodzielnego badania ultrasonograficznego przez lekarzy rodzinnych, na podstawie analizy wybranych artykułów. Materiał i metoda: Analiza objęła 15 artykułów wyszukanych w polskim piśmiennictwie, opublikowanych w latach 1994–2013 w 9 czasopismach medycznych. Publikacje znaleziono za pomocą różnych baz danych, takich jak Polska Bibliografia Lekarska, Google Scholar, strony internetowe pism „Lekarz Rodzinny” i „Ultrasonografia”. Wyniki: Z 15 dostępnych publikacji 5 stanowiły artykuły przedstawiające zastosowanie ultrasonografii w gabinecie lekarza rodzinnego w wymiarze ogólnym, w 4 opisano wykorzystanie badania jamy brzusznej, w 3 – szyi i węzłów chłonnych, w 1 – płuc oraz w 2 omówiono badanie w konkretnych jednostkach chorobowych. W ponad 70% prac poruszony został aspekt ekonomiczny związany z zastosowaniem ultrasonografii w gabinecie lekarza rodzinnego. W ponad połowie artykułów zwrócono uwagę na możliwość wykorzystania badań ultrasonograficznych typu point-of-care. Wśród zalet ultrasonografii najczęściej wymieniano korzystne badanie przesiewowe, bezpieczeństwo, krótki czas trwania, niski koszt badania. Autorzy ośmiu publikacji wskazali również wady związane ze stosowaniem USG w gabinecie lekarza rodzinnego. Wnioski: W polskim piśmiennictwie dostępnych jest niewiele publikacji opisujących rolę ultrasonografii w gabinecie lekarza pierwszego kontaktu. Ultrasonograf coraz częściej staje się narzędziem ułatwiającym lekarzowi podstawowej opieki zdrowotnej postawienie diagnozy, przyspiesza też rozpoczęcie leczenia pacjentów i ukierunkowuje dalszą diagnostykę.
Źródło:
Journal of Ultrasonography; 2016, 16, 64; 78-86
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Separation of Cells From Plasma by Means of Ultrasonics
Autorzy:
Włoch, Andrzej
Czyż, Henryka
Jasiński, Tadeusz
Powiązania:
https://bibliotekanauki.pl/articles/177025.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
ultrasound standing wave
medical diagnostics
body fluids
blood
red blood cells
cells separation
plasma
Opis:
This paper presents an analysis of use of ultrasonic standing wave in cell separation from bodily fluids based on the example of erythrocyte separation from plasma. It describes movement of red blood cells in plasma under the influence of the acoustic field (whose forces result from interaction of red blood cells with plasma as the vibrating medium) and under the influence of resistance forces in Stokes’ and Oseen’s approximation. The general properties of solutions of the motion equation are given. The solutions for the parameters of the ultrasonic wave and blood cells which are interesting in terms of practical applications in medical diagnostics are discussed. Time constants of the cell transportation to the regions of stable equilibrium in the field of ultrasonic standing wave are estimated. The formulas which determine the time needed to obtain the assumed concentration increase in plasma in nodes and/or anti-nodes of the standing wave are derived.
Źródło:
Archives of Acoustics; 2019, 44, 2; 357-363
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasonografia point-of-care w trakcie wykonywania misji ratunkowych na pokładzie śmigłowca Lotniczego Pogotowia Ratunkowego
Point-of-care ultrasonography during rescue operations on board a Polish Medical Air Rescue helicopter
Autorzy:
Darocha, Tomasz
Gałązkowski, Robert
Sobczyk, Dorota
Żyła, Zbigniew
Drwiła, Rafał
Powiązania:
https://bibliotekanauki.pl/articles/1057839.pdf
Data publikacji:
2014
Wydawca:
Medical Communications
Tematy:
emergency ultrasound
helicopter medical rescue service
rescue service
ratownictwo
ultrasonografia w stanach zagrożenia życia
śmigłowcowa służba ratownictwa medycznego
Opis:
Point-of-care ultrasound examination has been increasingly widely used in pre-hospital care. The use of ultrasound in rescue medicine allows for a quick differential diagnosis, identification of the most important medical emergencies and immediate introduction of targeted treatment. Performing and interpreting a pre-hospital ultrasound examination can improve the accuracy of diagnosis and thus reduce mortality. The authors’ own experiences are presented in this paper, which consist in using a portable, hand-held ultrasound apparatus during rescue operations on board a Polish Medical Air Rescue helicopter. The possibility of using an ultrasound apparatus during helicopter rescue service allows for a full professional evaluation of the patient’s health condition and enables the patient to be brought to a center with the most appropriate facilities for their condition.
Ukierunkowane badanie ultrasonograficzne (point-of-care ultrasound) jest coraz powszechniej stosowane w opiece przedszpitalnej. Zastosowanie ultrasonografii w medycynie ratunkowej umożliwia przeprowadzenie szybkiej diagnostyki różnicowej, identyfikację najważniejszych stanów zagrożenia życia i natychmiastowe wdrożenie ukierunkowanego leczenia. Wykonanie przedszpitalnego badania ultrasonograficznego wraz z jego interpretacją może poprawić dokładność diagnostyczną i tym samym wpłynąć na zmniejszenie śmiertelności. W niniejszej pracy przedstawiono doświadczenia własne autorów, dotyczące wykorzystania przenośnego, podręcznego aparatu ultrasonograficznego w trakcie wykonywania misji ratunkowych na pokładzie śmigłowca Lotniczego Pogotowia Ratunkowego. Wykorzystanie ultrasonografu w ramach służby śmigłowcowej daje możliwość pełnej profesjonalnej oceny stanu zdrowia pacjenta i pozwala na dotarcie pacjenta do ośrodka o najlepszym w danej sytuacji stopniu referencyjności.
Źródło:
Journal of Ultrasonography; 2014, 14, 59; 414-420
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Błędy i pomyłki w diagnostyce ultrasonograficznej tarczycy
Errors and mistakes in ultrasound diagnostics of the thyroid gland
Autorzy:
Dobruch-Sobczak, Katarzyna
Jędrzejowski, Maciej
Jakubowski, Wiesław
Trzebińska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/1058062.pdf
Data publikacji:
2014
Wydawca:
Medical Communications
Tematy:
fine needle biopsy
medical mistakes
thyroid
thyroid diseases
ultrasound imaging
biopsja cienkoigłowa
błędy w obrazowaniu tarczycy
choroby gruczołu tarczowego
tarczyca
Opis:
Ultrasound examination of the thyroid gland permits to evaluate its size, echogenicity, margins, and stroma. An abnormal ultrasound image of the thyroid, accompanied by other diagnostic investigations, facilitates therapeutic decision-making. The ultrasound image of a normal thyroid gland does not change substantially with patient’s age. Nevertheless, erroneous impressions in thyroid imaging reports are sometimes encountered. These are due to diagnostic pitfalls which cannot be prevented by either the continuing development of the imaging equipment, or the growing experience and skill of the practitioners. Our article discusses the most common mistakes encountered in US diagnostics of the thyroid, the elimination of which should improve the quality of both the ultrasound examination itself and its interpretation. We have outlined errors resulting from a faulty examination technique, the similarity of the neighboring anatomicalstructures, and anomalies present in the proximity of the thyroid gland. We have also pointed out the reasons for inaccurate assessment of a thyroid lesion image, such as having no access to clinical data or not taking them into account, as well as faulty qualification for a fine needle aspiration biopsy. We have presented guidelines aimed at limiting the number of misdiagnoses in thyroid diseases, and provided sonograms exemplifying diagnostic mistakes.
Badanie ultrasonograficzne tarczycy pozwala na ocenę jej wielkości, echogeniczności, granic oraz podścieliska. Zobrazowanie nieprawidłowego obrazu ultrasonograficznego tarczycy, w połączeniu z innymi badaniami diagnostycznymi, umożliwia podjęcie decyzji terapeutycznych. Obraz ultrasonograficzny prawidłowej tarczycy nie ulega istotnym zmianom wraz z wiekiem pacjenta. Mimo to w obrazowaniu tego gruczołu zdarzają się błędne opisy, wynikające z obecności pułapek diagnostycznych, którym nie są w stanie zapobiec stałe udoskonalanie sprzętu oraz wzrastające doświadczenie badających lekarzy. W artykule przedstawiono najczęstsze pomyłki w obrazowaniu ultrasonograficzym tarczycy, których wyeliminowanie powinno przyczynić się do poprawy jakości badań i ich interpretacji. Omówiono błędy wynikające z niewłaściwej techniki badania, podobieństwa anatomicznych struktur sąsiadujących z tarczycą oraz nieprawidłowych zmian występujących w sąsiedztwie gruczołu tarczowego. Wskazano również przyczyny złej interpretacji obrazu zmian w tarczycy, takie jak brak dostępu do danych klinicznych albo nieuwzględnienie ich, a także błędne kwalifikacje do biopsji cienkoigłowej. Przedstawiono wskazówki dotyczące postępowania w celu zminimalizowania występowania pomyłek w rozpoznawaniu chorób tarczycy oraz zaprezentowano przykłady obrazujące błędy diagnostyczne.
Źródło:
Journal of Ultrasonography; 2014, 14, 56; 61-73
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies