Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "measurement uncertainty estimation" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Estimation of measurement uncertainty with the use of uncertainty database calculated for optical coordinate measurements of basic geometry elements
Autorzy:
Owczarek, D.
Ostrowska, K.
Harmatys, W
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/101965.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
estimation of measurement uncertainty
optical coordinate measuring systems
Opis:
The paper presents a method for estimating the uncertainty of optical coordinate measurement based on the use of information about the geometry and the size of measured object as well as information about the measurement system, i.e. maximum permissible error (MPE) of the machine, selection of a sensor, and also the required measurement accuracy, the number of operators, measurement strategy and external conditions contained in the developed uncertainty database. Estimation of uncertainty is done with the use of uncertainties of measurements of basic geometry elements determined by methods available in the Laboratory of Coordinate Metrology at Cracow University of Technology (LCM CUT) (multi-position, comparative and developed in the LCM CUT method dedicated for non-contact measurements) and then with the use of them to determine the uncertainty of a given measured object. Research presented in this paper are aimed at developing a complete database containing all information needed to estimate the measurement uncertainty of various objects, even of a very complex geometry based on previously performed measurements.
Źródło:
Advances in Science and Technology. Research Journal; 2015, 9, 27; 112-117
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model badawczy elektroimpedancyjnego tomografu komputerowego
Researching model of computer electroimpedance tomography system
Autorzy:
Potyrański, P.
Dorozhovets, M.
Powiązania:
https://bibliotekanauki.pl/articles/158009.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
system tomografii elektroimpedancyjnej
pomiar
weryfikacja
szacowanie niepewności
method electroimpedance tomography system
measurement
verification
uncertainty estimation
Opis:
W artykule przedstawiono laboratoryjne rozwiązanie badawczego modelu elektroimpedancyjnego tomografu komputerowego. System opracowano dla badania właściwości nowej metody weryfikacji dokładności systemów tomografii elektroimpedancyjnej. Zaprezentowano założenia i budowę systemu oraz sposób szacowania jego dokładności.
In this paper the laboratory application of computer electroimpedance tomography systems researching model are presented. The system is elaborated for new accuracy verification method of electroimpedance tomography systems properties investigation. The system assumptions and construction and its accuracy estimating way are described.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 12, 12; 55-57
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niepewność wytrzymałości betonu na ściskanie uzyskiwana na próbkach sześciennych
Uncertainty of strength for cubical samples concrete
Autorzy:
Sobolewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/40491.pdf
Data publikacji:
2012
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
materialy budowlane
beton
wytrzymalosc na sciskanie
niepewnosc wynikow pomiaru
szacowanie niepewnosci pomiarow
klasy wytrzymalosci
building material
concrete
compression strength
measurement uncertainty
measurement uncertainty estimation
strength class
Źródło:
Acta Scientiarum Polonorum. Architectura; 2012, 11, 1
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oszacowanie niepewności wytrzymałości betonu na ściskanie uzyskiwanej na próbkach sześciennych
Estimation of uncertainty of strength for cubical samples concrete
Autorzy:
Sobolewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/40754.pdf
Data publikacji:
2012
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
materialy budowlane
beton
wytrzymalosc na sciskanie
niepewnosc wynikow pomiaru
szacowanie niepewnosci pomiarow
klasy wytrzymalosci
building material
concrete
compression strength
measurement uncertainty
measurement uncertainty estimation
strength class
Źródło:
Acta Scientiarum Polonorum. Architectura; 2012, 11, 4
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estymacja niepewności charakterystyki z pomiarów w punktach kontrolnych
Estimation of the uncertainty of function values from measurements at control points
Autorzy:
Warsza, Z. L.
Puchalski, J.
Powiązania:
https://bibliotekanauki.pl/articles/277555.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
estymacja
niepewność badanej funkcji
punkty kontrolne
pomiary pośrednie
multimenzurand
błędy graniczne
estimation of the uncertainty of the examined function
measurement checkpoints
indirect measurements
multidimension measurand
limited errors
Opis:
W pracy omówiono dwie metody estymacji niepewności kilku wartości funkcji opisującej badaną charakterystykę na podstawie pomiarów w punktach kontrolnych. Metoda I, nazwana deterministyczną, wykorzystuje w interpolacji niepewności typu B w tych punktach korzystając z liniowej aproksymacji przebiegu maksymalnych dopuszczalnych błędów przyrządów. Metoda II polega na statystycznej estymacji niepewności dla wartości funkcji jako liniowej kombinacji wyników pomiarów w punktach kontrolnych. Do wyznaczenia niepewności użyto macierzowego równania propagacji wariancji w pośrednich pomiarach wieloparametrowych, podanego w Suplemencie 2 do Przewodnika GUM. Jest to rozszerzenie zastosowania tego Suplementu. Dla dwu interpolowanych wartości porównano wyniki estymacji niepewności względnych i bezwzględnych oraz ich sumy i różnicy otrzymane obiema metodami. Do interpolacji badanej funkcji w całym zakresie podano zasadę minimalizacji liczby kontrolnych punktów pomiarowych. Obie metody można stosować w wielu obszarach współczesnej metrologii.
The paper discusses two methods of interpolation and extrapolation of the uncertainty of a values of the tested function, based on measurements in several its points. The first of these is the deterministic method based on a linear approximation of the uncertainty function without considering the correlation of its interpolated values. The second statistical method consists in the statistical estimation of uncertainty for any values of the function under test as a linear combination of the measurement result parameters at several control points. To determine the uncertainty, a matrix equation for the propagation of variances of indirectly measured multivariable measurand, was used. This is an extension of the scope of application of Supplement 2 to the GUM guide. The relative and absolute uncertainties of values of linear function are interpolated by both methods and their sum and difference were compared. Interpolations in the whole range of the examined function were proposed and the procedure of minimizing the number of measuring points was presented. Both methods can be useful in all areas of modern metrology applications.
Źródło:
Pomiary Automatyka Robotyka; 2018, 22, 4; 39-50
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena niepewności punktów charakterystyki z dwu pomiarów kontrolnych
Estimation uncertainties of points of function from two control measurements
Autorzy:
Warsza, Zygmunt Lech
Puchalski, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/267312.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
estymacja
niepewności punktów charakterystyki
punkty kontrolne
dopuszczalny maksymalny błąd pomiaru
pomiary pośrednie
macierz kowariancji
współczynnik korelacji
indirect measurements
permissible maximum measurement error
uncertainty estimation
values of the characteristic
control points
covariance matrix
correlation coefficient
Opis:
Omówiono szacowanie niepewności punktów funkcji opisującej badaną charakterystykę na podstawie wyników pomiarów w dwu punktach kontrolnych. Zastosowano dwie metody I i II. Metodą I estymuje się składowe niepewności typu B na podstawie wartości dopuszczalnych maksymalnych błędów aparatury stosowanej do pomiarów w punktach kontrolowanych tej charakterystyki. Przy stabilnych warunkach pomiaru kilku wartości i pomijalnej niepewności typu A, należy dla wyników przyjąć współczynnik korelacji równy 1. Metodą statystyczną II, na podstawie pomiarów w punktach kontrolnych estymuje się składowe niepewności typu A oraz niepewności złożone dla punktów badanej funkcji i korelację pomiędzy ich wynikami. Korzysta z równania wiążącego macierze kowariancji w pomiarach pośrednich wieloparametrowych wg Suplementu 2 Przewodnika GUM. Wyznaczono też niepewności względne i bezwzględne dla sumy i różnicy wartości dwu punktów i podano przykłady obliczeń. Przy ograniczonej liczbie i czasie wykonywania pomiarów, metodą tą można wyznaczaniu niepewności funkcji opisującej badaną charakterystykę i wykorzystać ja w monitoringu, kontroli i diagnostyce różnych obiektów.
The estimation of the uncertainty of points of the function describing the tested characteristics based on measurement results at two control points is discussed. Two methods were used. By method I, the type B uncertainty component is estimated from the permissible values of the maximum error of the apparatus used for measurements at the controlled points of this tested characteristic. With stable measurement conditions and negligible uncertainty of type A of measurements, a correlation coefficient equal to 1 should be assumed for results of several points measured by the same insturment. The method II is statistical It is based on measurement data at control points and is used for estimation of type A and combined uncertainties of the function values of the points being tested. Correlation coefficient between their results are also estimated. Used for that is the equation binding the covariance matrices in indirect multiparameter measurements according to the Supplement 2 of the GUM Guide. Relative and absolute uncertainties for the sum and difference of values of two points were also determined and few examples of calculations were given. With a limited number and duration of measurements, this method can be used in the monitoring, automatic control and diagnosis of various objects.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 66; 101-108
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The analysis of approaches to measurement uncertainty evaluation for calibration
Analiza przypadków w ocenie niepewności pomiaru na potrzeby kalibracji
Autorzy:
Zhussupbekov, Sarsenbek S.
Khan, Svetlana G.
Ibrayeva, Lida K.
Powiązania:
https://bibliotekanauki.pl/articles/952721.pdf
Data publikacji:
2019
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
measurement uncertainty
GUM and Monte Carlo uncertainty estimation method
calibration of an electromagnetic flowmeter
niepewność pomiaru
metoda szacowania niepewności GUM i Monte Carlo
kalibracja przepływomierza elektromagnetycznego
Opis:
A comparative analysis of the measurement uncertainty estimation result is carried out. The results are obtained by GUM method described in the Guide to the expression of uncertainty in measurement, as well as by Monte-Carlo method recommended in Supplement 1 to the Guide. Examples of calculations of uncertainty of relative error for electromagnetic flow meters calibration by two methods are given. The features of application, advantages and disadvantages of these methods are described.
W pracy omówiono analizę porównawczą wyniku oszacowania niepewności pomiaru. Wyniki uzyskano metodą GUM, opisaną w przewodniku do wyrażania niepewności pomiaru, a także metodą Monte-Carlo zalecaną w Suplemencie 1 do tego przewodnika. Podano przykłady obliczeń niepewności błędu względnego dla kalibracji przepływomierzy elektromagnetycznych za pomocą dwóch metod. W artykule opisano cechy zastosowaia, w tym: zalety oraz wady tych metod.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2019, 9, 3; 26-29
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies