Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "measurement problem" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
Is Schrödingers cat dead or alive?
Autorzy:
Grygiel, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/942951.pdf
Data publikacji:
2005
Wydawca:
Copernicus Center Press
Tematy:
decoherence
measurement problem
quantum logic
quantum mechanics
Schrödinger's cat
Opis:
The Schrödinger's Cat paradox was proposed in 1935 by Edwin Schrodinger, one of the founders of quantum mechanics, as an attempt to visualize the macroscopic realization of a quantum superposition state. A cat is placed in a sealed box together with a vial of poison. A two-state particle (e.g. an electron) is sent into a detector in the box resulting either in a broken or an intact vial and a dead or live cat, respectively. The main problem consists in whether the superposition state of a microscopic particle can be transferred upon the macroscopic cat, that is, whether the cat can exist in a superposition state, being simultaneously dead and alive. Since the standard Copenhagen interpretation is unable to assign any reality to the quantum superposition state, the paradox finds no resolution within the regime of this interpretation. Von Neumann's insistence on the uniform treatment of both microscopic (quantum) and macroscopic (classical) objects according to the laws of quantum mechanics provides a more consistent framework for the resolution of the paradox. In particular, the discovery of the phenomenon of decoherence, whereby the disappearance of the quantum interferences at the macro level is accounted for, suggests the onset of an extremely efficient interference relaxation process (10-23 s) upon the interaction of the two state particle with the detector. As a result, Schrodinger's cat can exist macroscopically either as dead or alive and never as a combination of both. Decoherence not only aids the resolution of the Schrodinger's Cat paradox but also sheds light upon the mechanisms by which the macro-world emerges from the microscopic quantum realm.
Źródło:
Zagadnienia Filozoficzne w Nauce; 2005, 37; 119-139
0867-8286
2451-0602
Pojawia się w:
Zagadnienia Filozoficzne w Nauce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Does the quantum mechanical wave function exist?
Autorzy:
Kiefer, Claus
Powiązania:
https://bibliotekanauki.pl/articles/690936.pdf
Data publikacji:
2019
Wydawca:
Copernicus Center Press
Tematy:
wave function
quantum mechanics
ontology
quantum formalism
superposition principle
measurement problem
decoherence
quantum gravity
Opis:
I address the question whether the wave function in quantum theory exists as a real (ontic) quantity or not. For this purpose, I discuss the essentials of the quantum formalism and emphasize the central role of the superposition principle. I then explain the measurement problem and discuss the process of decoherence. Finally, I address the special features that the quantization of gravity brings into the game. From all of this I conclude that the wave function really exists, that is, it is a real (ontic) feature of Nature.
Źródło:
Zagadnienia Filozoficzne w Nauce; 2019, 66; 111-128
0867-8286
2451-0602
Pojawia się w:
Zagadnienia Filozoficzne w Nauce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of flow rate in square-sectioned duct bend
Pomiar strumienia płynu w kanale z łukiem kolana o przekroju kwadratowym
Autorzy:
Rup, K.
Malinowski, Ł.
Sarna, P.
Powiązania:
https://bibliotekanauki.pl/articles/280883.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
measurement of flow rate
inverse coefficient problem
Opis:
In this paper the authors describe an attempt to utilise installed square- sectioned elbows in order to measure the fluid flow rate. In order to practically accomplish the measurement of the volumetric flow rate of the air, a special research stand has been built, and square shaped elbows have been installed (80 × 80mm in dimension). The numerical computations were carried out using the software package FLUENT 6.2. The obtained results were compared to corresponding ones coming from orifice measurements and from experimental work available in the literature. The comparative analysis of the obtained numerical and experimental results evidenced a high degree of their conformity.
W pracy podjęto próbę wykorzystania zainstalowanych w kanałach przepływowych łuków kolan o przekroju kwadratowym do pomiaru strumienia objętości płynu. W tym celu wykorzystano opracowaną wcześniej metodę pomiaru pośredniego dla rurociągów o przekroju kołowym. Dla praktycznej realizacji pomiaru wspomnianego strumienia przepływu zbudowano stanowisko badawcze za łukiem kolana o przekroju poprzecznym w kształcie kwadratu (80 × 80mm). Obliczenia wykonano za pomocą pakietu FLUENT 6.2. Uzyskane rezultaty porównano z odpowiednimi zmierzonymi za pomocą kryzy pomiarowej oraz z innymi wynikami doświadczalnymi dostępnymi w literaturze. Z analizy porównawczej wynika wysoki stopień zgodności otrzymanych rezultatów pomiaru pośredniego.
Źródło:
Journal of Theoretical and Applied Mechanics; 2011, 49, 2; 301-311
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring of deep foundation deflection in model experiments by means of a magnetic method: theoretical study
Autorzy:
Wtorek, J.
Kurałowicz, Z.
Truyen, B.
Powiązania:
https://bibliotekanauki.pl/articles/241303.pdf
Data publikacji:
2004
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
pile deflection
measurement
magnetic method
inverse problem
Opis:
In this paper, a new contact-free method for monitoring the displacement of buried foundations, with application to model (laboratory) studies, is considered. This method is based on the measurement of the magnetic induction amplitude created by a magnetic dipole attached to the construction. An array of sensing coils, located distantly, measures the changes in magnetic induction amplitude invoked by displacement of the signal source. The forward and inverse problems are formulated. Reconstruction of the source displacement is performed for synthetic data, both contaminated and uncontaminated by noise. It has been found that the reconstruction of displacements as small as 0.001 m is possible for distances between signal source (transmitting coil - magnetic dipole) and coil array of 0.5 m, even for data contaminated by noise.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2004, 51, 3; 225-241
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza niepewności wyznaczenia rozkładu wydłużenia siatki Bragga na podstawie jej charakterystyk spektralnych
The uncertainty analysis of the strain distribution recovery of the fiber Bragg grating on the basis of its spectra
Autorzy:
Wójcik, W.
Kisała, P.
Powiązania:
https://bibliotekanauki.pl/articles/157068.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
światłowodowe siatki Bragga
rozkład wydłużenia
problem odwrotny
niepewność pomiaru
fiber Bragg gratings
strain distribution
inverse problem
uncertainty of the measurement
Opis:
W artykule przedstawiono analizę niepewności wyznaczenia parametrów siatki Bragga na podstawie jej widma. Analizowane parametry to okresy siatki mierzone w kilku obszarach, na jej długości, które zostały zastosowane do wyznaczenia jej wydłużenia względnego. Do obliczeń zastosowano analizę odwrotną. Zdefiniowano zadanie wprost, a przy wykorzystaniu modelu siatki i iteracyjnego algorytmu symulowanego wyżarzania zaprezentowano rozwiązanie zadania odwrotnego, polegającego na wyznaczeniu zmian wydłużenia względnego siatki na podstawie jej charakterystyk spektralnych.
This paper outlines the uncertainty analysis of the fiber Bragg grating strain distribution recovery. The grating spectra was used to carry out the analysis above. The inverse problem solution was also discussed. Analyzed parameters (grating period values), were distributed in a few points along the grating length. On the basis of the Bragg grating period values its strain values were determined. The inverse analysis was used for calculations. Initially the forward problem was defined. Then the inverse problem solution was presented by the use of the mathematical model of the Bragg grating sensor and the presented simulated annealing algorithm. The inverse problem depends on recovery of the strain distribution of the grating on its spectra basis. The measurement uncertainty was treated as a difference between the spectra values from the measurement and the real value of this spectra. This uncertainty characterizes the scatter (range width) inside which we could locate the spectra values with the satisfactory probability. As a uncertainty measure we accepted the standard deviation of the indirect measurement or in other words the root mean squared error. Six spectra of the grating were analyzed. In every case we checked if the changes of the spectra measurement uncertainty (root mean squared error between two spectra) had an influence on the uncertainty of the strain distribution recovery.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 5, 5; 427-429
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the electrical capacitance tomography system for measurement using 3D sensor
Ocena systemu elektrycznej tomografii pojemnościowej do pomiarów z wykorzystaniem sondy 3D
Autorzy:
Kryszyn, Jacek
Wanta, Damian
Smolik, Waldemar T.
Powiązania:
https://bibliotekanauki.pl/articles/407860.pdf
Data publikacji:
2019
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
electrical capacitance tomography
image reconstruction
capacitance measurement
inverse problem
numerical stability
elektryczna tomografia pojemnościowa
rekonstrukcja obrazów
pomiar pojemności
problem odwrotny
stabilność numeryczna
Opis:
Further tests of EVT4 data acquisition system for electrical capacitance tomography are presented. The modular system, which can have up to 32 channels with an individual analogue to digital converter, was designed to ensure small uncertainty of capacitance measurement at high speed of imaging. The system’s performance in the context of 3D imaging was experimentally verified. In particular, we show that the measurement of changes in capacitance due to a small change of an electric permittivity distribution for the most distant electrodes in a suitably designed 3D sensor is possible using our system. Cross-plane measurements together with the measurements for the pairs of most distant electrodes are essential for accurate reconstruction of 3D distributions. Due to sensitivity of capacitance measurements obtained in the hardware, the measurements for all electrode pairs can be used in the inverse problem – the system of equations can be extended. Although the numerical condition number of a matrix of such a system is high, image reconstruction is possible from the data obtained in our system. The results of 3D image reconstruction for simple test objects are shown.
Przedstawiono dalsze testy systemu akwizycji danych EVT4 do elektrycznej tomografii pojemnościowej. Modułowy system, który może mieć do 32 kanałów z indywidualnym przetwornikiem analogowo-cyfrowym, został zaprojektowany w celu zapewnienia małej niepewności pomiaru pojemności przy dużej prędkości obrazowania. Wydajność systemu w kontekście obrazowania 3D została zweryfikowana eksperymentalnie. W szczególności pokazujemy, że możliwy jest pomiar zmian pojemności wywoływanych niewielką zmianą rozkładu przenikalności elektrycznej dla najbardziej odległych elektrod odpowiednio zaprojektowanego czujnika 3D przy pomocy naszego systemu. Pomiary międzypłaszczyznowe wraz z pomiarami par elektrod najbardziej odległych są niezbędne do dokładnej rekonstrukcji rozkładów 3D. Ze względu na wrażliwość pomiarów pojemności uzyskanych w opracowanym urządzeniu, pomiary dla wszystkich par elektrod mogą być wykorzystane w problemie odwrotnym – układ równań może zostać rozszerzony. Chociaż współczynnik uwarunkowania numerycznego macierzy takiego układu jest wysoki, możliwa jest rekonstrukcja obrazu z wykorzystaniem danych uzyskiwanych w naszym systemie. Pokazane są wyniki rekonstrukcji obrazu 3D dla prostych obiektów testowych.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2019, 9, 4; 52-59
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of heat flux density and heat transfer coefficient
Autorzy:
Taler, D.
Taler, J.
Grądziel, S.
Powiązania:
https://bibliotekanauki.pl/articles/240288.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pomiar temperatury
strumień ciepła
współczynnik przenikania ciepła
zagadnienie odwrotne
heat flux
heat transfer coefficient
inverse problem
temperature measurement
Opis:
The paper presents the solution to a problem of determining the heat flux density and the heat transfer coefficient, on the basis of temperature measurement at three locations in the flat sensor, with the assumption that the heat conductivity of the sensor material is temperature dependent. Three different methods for determining the heat flux and heat transfer coefficient, with their practical applications, are presented. The uncertainties in the determined values are also estimated.
Źródło:
Archives of Thermodynamics; 2010, 31, 3; 3-18
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New technique of the local heat flux measurement in combustion chambers of steam boilers
Autorzy:
Taler, J.
Taler, D.
Sobota, T.
Dzierwa, P.
Powiązania:
https://bibliotekanauki.pl/articles/240253.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kocioł parowy
odwrotne zagadnienie przewodzenia ciepła
pomiar strumienia ciepła
żużlowanie komory paleniskowej
CFD simulation
heat flux measurement
inverse heat conduction problem
slagging of combustion chambers
steam boiler
Opis:
A new method for measurement of local heat flux to waterwalls of steam boilers was developed. A flux meter tube was made from an eccentric tube of short length to which two longitudinal fins were attached. These two fins prevent the boiler setting from heating by a thermal radiation from the combustion chamber. The fins are not welded to the adjacent water-wall tubes, so that the temperature distribution in the heat flux meter is not influenced by neighbouring water-wall tubes. The thickness of the heat flux tube wall is larger on the fireside to obtain a greater distance between the thermocouples located inside the wall which increases the accuracy of heat flux determination. Based on the temperature measurements at selected points inside the heat flux meter, the heat flux absorbed by the water-wall, heat transfer coefficient on the inner tube surface and temperature of the water-steam mixture was determined.
Źródło:
Archives of Thermodynamics; 2011, 32, 3; 103-116
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies