Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "measurement circuits" wg kryterium: Temat


Wyświetlanie 1-14 z 14
Tytuł:
The Parameters of Unconventional Double-Current Circuit, their Accuracy Measures and Measurement of Strain and Temperature
Autorzy:
Warsza, Z.
Idzkowski, A.
Walendziuk, W.
Powiązania:
https://bibliotekanauki.pl/articles/227208.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electronics
measurement circuits
Opis:
The two-voltage-output circuit called a double-current bridge is presented. A single DC current source is switched over and connected in turns to opposite arms of the four-element bridge circuit. The output voltages are dependent on the arm resistance increments and their values are given in absolute and relative units. The simplified signal conditioning formulas of strain and temperature simultaneous measurement of a cantilever beam are featured. The results achieved with the use of the circuit are also published.The accuracy measures (actual errors, limited errors and standard uncertainties) of the bridgetransfer functions are described.
Źródło:
International Journal of Electronics and Telecommunications; 2014, 60, 4; 327-330
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simultaneous measurement of two parameters by double current supplied bridge
Autorzy:
Idzkowski, A.
Makal, J.
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/384411.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
multivariable measurement circuits
bridge circuit
strain measurement
Opis:
A four-terminal (4T) bridge-circuit, with two voltage outputs is presented. This circuit, named as double current bridge is supplied by two equal current sources connected in parallel to opposite arms (2J) or by one such source switched between those arms (2x1J). Two output voltages from bridge diagonals as functions of arm resistance increments in absolute and in relative units are given. Also the example of this bridge application is proposed. Signal conditioning formulas of two-parameter measurement on the example of strain and temperature are discussed in detail. Some results obtained with the use of this bridge-circuit are briefly described.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2012, 6, 2; 26-31
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stanowisko do badania sensorów z akustyczną falą powierzchniową
A system for SAW sensors research
Autorzy:
Grabka, M.
Jasek, K.
Pasternak, M.
Miluski, W.
Powiązania:
https://bibliotekanauki.pl/articles/271324.pdf
Data publikacji:
2015
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
sensory z akustyczną falą powierzchniową (AFP)
akustoelektroniczne układy pomiarowe
surface acoustic wave (SAW) sensors
SAW sensors measurement circuits
Opis:
Układy elektroniczne współpracujące z sensorami z AFP mają najczęściej postać oscylatora, którego zmiany częstotliwości rezonansowej odzwierciedlają zmiany prędkości propagacji AFP. Pomiar samych zmian częstotliwości rezonansowej utrudnia lub nawet uniemożliwia wydobycie istotnych informacji o mechanizmach oddziaływania warstwy sensorowej z otoczeniem. W pracy przedstawiono zaprojektowane i wykonane w Wojskowej Akademii Technicznej (WAT) stanowisko do badania sensorów z AFP, w którym klasyczny układ oscylatora został zastąpiony systemem liniowym z wymuszeniem zewnętrznym, generowanym przez stabilny generator sygnału ze schodkową modulacją częstotliwości. Obok pomiaru częstotliwości rezonansowej, układ umożliwia pomiary tłumienia i fazy AFP, co pozwala na pełniejsze wykorzystanie możliwości detekcyjnych sensorów. W pracy przedstawiono zasadę działania, opis konstrukcji stanowiska z prototypową matrycą czujników z AFP oraz opis oprogramowania sterującego.
An electronic circuits collaborating with SAW sensors have usually a self-oscillator architecture where resonant frequency changes reflect the SAW velocity changes. Unfortunately the measurements including the resonant frequency only make the substantial information concerning interaction mechanism between sensor layer and ambient gases hard or even impossible to extract. In the paper a prototype laboratory test stand for SAW sensors designed and manufactured in Military University of Technology is described. In the system typical self-oscillating circuits with SAW device working inside positive feedback loop was replaced by the linear system with stepped frequency source. The system allows the measurements of signal amplitude and phase shift besides frequency changes. It gives a possibility of more complete insight into the SAW-ambient gas interaction mechanism. In the paper operating principle of the system as well as control software for test stand with SAW matrix are described.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2015, 20, 4; 251-258
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ do pomiaru tłumienia napięcia współbieżnego precyzyjnych komparatorów napięcia typu LM111
Circuit for measuring of common mode rejection ratio of precise voltage comparators type LM111
Autorzy:
Wiśniewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/158333.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
komparatory napięcia
miernictwo układów scalonych
układy scalone
integrated circuits
measurement of integrated circuits
voltage comparators
Opis:
W pracy rozważono zagadnienie pomiaru, przy prądzie przemiennym i zamkniętej pętli sprzężenia zwrotnego, współczynnika tłumienia napięcia współbieżnego (CMRR) o wartości rzędu 1•105 ÷ 1•107 (tj. (100 ÷ 140) dB) scalonych komparatorów napięcia typu LM111. W wyniku przeprowadzonej analizy teoretycznej właściwości metrologicznych układu pomiarowego ustalono istotny związek między stosunkiem mierzonych w układzie napięć, zależnym od współczynnika CMRR, a innymi parametrami badanego komparatora napięcia, w tym zwłaszcza wzmocnieniem napięcia różnicowego, stanowiący podstawę ilościowej oceny błędu metody pomiarowej. Zaproponowano nowe techniczne rozwiązanie układu pomiarowego zawierające specjalny transformator pomiarowy napięcia przemiennego wyposażony we wtórne uzwojenia o nawoju bifilarnym, co przyczyniło się do wyeliminowania wpływu skończonej wartości wzmocnienia różnicowego badanego komparatora napięcia na mierzoną wartość współczynnika CMRR.
The comparator open-loop common-mode rejection ratio (CMRR) is a measure of the comparator's ability to reject common signals present in equal measure at both inputs. CMRR according to the definition is the ratio of the differential-mode gain to common-mode gain. Often, manufacturer data sheets only give DC CMRR value and CMRR curve over frequency while no measurement methods are given. The present work deals with measurements of common mode rejection ratio of values of the order 1•105 ÷ 1•107 (i.e. (100 ÷ 140) dB) of the voltage comparators type LM111. The present investigation concerns the method of measurement of coefficient CMRR with closed loop feedback of voltage comparator at alternating current. Important relationship between measured output voltage (Uwy) and finite values of parameters of comparator and others parameters of measuring circuit has been discovered by means of detailed analysis (see equations (12) and (17)). This relationship is the basis for quantitative analysis of the error of measuring method. Finally proposed - by author - a new solution of measuring circuit different from others existing up to date offer significant improvements over previous methods and is capable of accurate measurements on high-performance analogue comparators. It is based on special precise inductive voltage transformer with bifilar windings (Tr, Fig. 4). Such the error of measuring method is independent from finite value of differential open loop voltage gain and the output voltage is directly related to CMRR. The unity gain differential amplifier (buffer) which is implemented at input device under test (DUT: KB, Fig. 2÷4) eliminates differential and common-mode input resistances of DUT on measuring output voltage and thereby CMRR.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 10, 10; 1238-1242
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of Two Buffers for Impedance Metrology
Autorzy:
Kampik, M.
Tokarski, J.
Musioł, M.
Barwinek, W.
Rybski, R.
Kaczmarek, J.
Kozioł, M.
Nissila, J.
Powiązania:
https://bibliotekanauki.pl/articles/114359.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
bridge circuits
impedance
measurement standards
metrology
precision measurements
Opis:
The paper presents results of investigations of the two precise voltage followers (buffers) intended for the use in precision impedance metrology. The main application of these buffers are buffering the outputs of multi-phase digital sources of sinusoidal voltage used in precise impedance measurements.
Źródło:
Measurement Automation Monitoring; 2015, 61, 5; 127-131
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Single phase UPS systems loaded with nonlinear circuits: analysis of topology in the context of electric power quality
Autorzy:
Szulborski, Michał
Kolimas, Łukasz
Łapczyński, Sebastian
Szczęśniak, Przemysław
Powiązania:
https://bibliotekanauki.pl/articles/140626.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrical measurement
harmonic distortion
nonlinear circuits
uninterruptible power supply
Opis:
Along with the increase in the use of nonlinear electronic devices, e.g. personal computers, power tools and other electrical appliances, the requirements for uninterruptible power supplies are constantly growing. This paper proposes a method and deep analysis of results viable for checking how single-phase uninterruptible power supplies (UPSs) cope with nonlinear circuits under varying power loads in terms of electric energy quality. Various classes of single-phase UPS systems with different topologies were tested, for instance line-interactive and double conversion (online) single-phase UPS devices. Furthermore, measurements were carried out in view of a power source – loads were supplied both from a power grid and UPS built-in battery. Juxtaposition of the obtained results such as a THDU , THDI (Total Harmonic Distortion) percentage ratio of input/output voltage and current, a power factor and crest factor volume etc. of the tested UPS systems indicated major differences in their performance during laboratory tests.
Źródło:
Archives of Electrical Engineering; 2019, 68, 4; 787-802
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A system for 256-channel in vitro recording of the elect rophysiological activity of brain tissue
Autorzy:
Zoladz, M.
Powiązania:
https://bibliotekanauki.pl/articles/963870.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multichannel measurement systems
neurobiological measurements
application specific integrated circuits
Opis:
A measurement system for 256-channel in vitro recordings of brain tissue electrophysiological activity is presented in the paper. The system consists of the brain tissue life support system, Microelectrode Array (MEA), conditioning Application Specific Integrated Circuits (ASIC’s) for signals conditioning, Digitizer and PC application for measurement data presentation and storage. The life support system keeps brain tissue samples in appropriately saturated artificial cerebrospinal fluid at a very stable temperature. The MEA consists of two hundred and fifty-six 40 μm diameter tip-shaped electrodes. The ASIC’s performs amplification and filtering of the 256-field and action potential signals. The Digitizer performs simultaneous data acquisition from 256 channels 14 kS/s sample rate and 12-bit resolution. The resulting byte stream is transmitted to the PC via USB (Universal Serial Bus). Preliminary tests confirm that the system is capable of keeping the extracted brain tissue active (hippocampal formation slices) and simultaneously to record action potentials, as well as local theta field potentials with very small amplitudes from multiple neurons.
Źródło:
Metrology and Measurement Systems; 2013, 20, 3; 371-384
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wirtualny miernik pojemności realizujący quasi-zrównoważoną metodę pomiaru modułu
Virtual capacitance meter realizing a quasi-balanced method of impedance modulus measurement
Autorzy:
Cichy, A.
Skórkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/157878.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiar pojemności
układy quasi-zrównoważone
capacitance measurement
quasi-balanced circuits
Opis:
Pomiar pojemności dwójnika może być dokonany poprzez pomiar modułu impedancji badanego obiektu. Jest to możliwe, jeżeli badaniu podlega obiekt o skrajnie różniących się składowych (np. kondensator niskostrat-ny). Wówczas błąd przybliżenia składowej dominującej modułem impe-dancji może być pomijalnie mały. W pracy przedstawiona została wirtual-na realizacja miernika pojemności wykorzystującego pomiar modułu impedancji i realizującego szczególną, niezerową metodę pomiaru - quasi-zrównoważoną metodę pomiarową. Miernik został zbudowany z wykorzy-staniem karty pomiarowej USB NI-6009 oprogramowanej w środowisku LabVIEW.
Measurements of a capacitance can be performed by the measurement of an impedance modulus of an investigated object. It is possible, if a two-terminal network is represented by a series connection of a resistor and a capacitor and the reactance of the capacitor is considerably greater than the resistance ( e.g. in a low-loss capacitor). In this case the error of the approximation can be omitted, as it has been shown in the equations (1)…(12). A virtual realization of such meter has been presented in this paper. The Fig. 2 shows the idea of the signal processing in the quasi-balanced circuit. Quasi-balanced circuits are the AC circuits designated for impedance components measurements. Similar as the balanced circuits, the quasi-balanced circuits have a special status called a quasi-balance status. This is usually a phase shift between two selected signals of the circuits. The circuit is driven to the quasi-balance status by controlling of only one variable element and then the value of the measured impedance component can be calculated according to the adjusting of the variable element. The meter has been built with the application of data acquisitation card USB NI-6008, which has been controlled by a software programmed in the LabVIEW environment.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 12, 12; 94-96
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wirtualny quasi-zrównoważony układ do pomiaru współczynnika strat dielektrycznych
Virtual quasi-balanced circuit for the loss factor measurement
Autorzy:
Cichy, A.
Skórkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/151204.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiar współczynnika start dielektrycznych
układy quasi-zrównoważone
loss factor measurement
quasi-balanced circuits
Opis:
Pomiary współczynnika strat dielektrycznych (tgδ) wykonuje się przede wszystkim w badaniach materiałowych oraz w celu diagnozowania stanu izolacji. Metody pomiaru współczynnika start dielektrycznych charaktery-zują się różnymi właściwościami, w pewnych przypadkach utrudniającymi lub uniemożliwiającymi pomiar. Pomiar tgδ może być wykonywany bezpośrednio lub pośrednio - poprzez pomiar składowych impedancji lub admitancji. W pracy przedstawiona została wirtualna realizacja quasi-zrównoważonego układu do pomiaru współczynnika strat dielektrycznych wykorzystującego pomiar składowych impedancji. Układ zrealizowano z wykorzystaniem karty pomiarowej NI-6009 oprogramowanej w środo-wisku LabVIEW.
Measurement of a dielectric loss factor is needed in material testing and in an insulation diagnostics. The methods of the loss factor measurement have different features, depending on an investigated object or frequency. In some cases the measurement is very tedious or impossible at all and then special measurement circuits (for example quasi-balanced circuits) should be used. The quasi-balanced circuits are AC circuits, which have been designated for impedance component measurements. The quasi-balanced circuits have a special status called a quasi-balance status. This is usually a phase shift between two selected signals of the circuit. The circuit is driven to the quasi-balance status by controlling of one variable element. Then the value of the measured impedance component can be calculated according to the adjusted value of the variable element. The idea of the signal processing in the quasi-balanced circuit has been shown on Fig. 4. A virtual realization of the quasi-balanced circuit for loss factor measurements has been presented in this paper. The circuit has been built with the data acquisition card NI-6009, as a LabVIEW virtual instrument.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 2, 2; 48-51
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System do testowania specjalizowanych układów scalonych do odczytu detektorów paskowych
Test system for the silicon strip detector readout application-specific integrated circuits
Autorzy:
Kasiński, K.
Powiązania:
https://bibliotekanauki.pl/articles/276900.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
system pomiarowy
specjalizowane układy scalone
testowanie
measurement system
application-specific integrated circuits
test
Opis:
Artykuł przedstawia wybrane metody testowania specjalizowanych układów scalonych (ASIC) do odczytu paskowych detektorów krzemowych pod kątem ekstrakcji wybra-nych parametrów toru analogowego z uwzględnieniem zarówno stosowanego sprzętu, jak i oprogramowania. Jako przykładową aplikację wybrano system testowy dla układu ASIC TOT01, wyprodukowanego jako układ prototypowy dla potrzeb detektora STS w eksperymencie CBM. Prezentowany system służy do pomiaru ilości energii zdeponowanej w detektorze krzemowym wskutek interakcji z cząstką lub kwantem promieniowania z wykorzystaniem metody time-over-threshold. W każdym kanale układu TOT01 zmajdują się m.in. wzmacniacz ładunkowy, dyskryminator z histerezą oraz korekcyjny układ cyfrowo-analogowy. Odpowiedni dobór sprzętu pomiarowego, niskoszumnych zasilaczy i generatorów oraz zapewnienie ich zdalnej pracy pod nadzorem dedykowanego oprogramowania są bardzo ważne. Niewielkie wymiary samego układu (1,5 × 3,4 mm2) oraz mnogość wyprowadzeń (81), obecność domen niskoszumnych analogowych oraz cyfrowych, konieczność podłączenia układu do detektora krzemowego i zapewnienia możliwości pracy całego systemu w warunkach promieniowania X nakładają również bardzo wysokie wymagania na obwód drukowany.
This paper presents selected methods of testing the application-specific integrated circuits for silicon strip detector readout with the emphasis on the analog parameter's extraction, equipment and software tools used. As an example application the TOT01 ASIC test system (prototype IC for the STS detector at the CBM experiment) has been selected. Its functionality includes measurement of the energy deposited in the silicon detector as a result of its interaction with a particle of radiation photon. The circuit implements the time-over-threshold method. Its internal structure comprises of charge-sensitive amplifier, discriminator with hysteresis and trimming digital-analog converter. Proper selection of the measurement equipment, low-noise power supplies and generators together with their remote operation under the supervision of dedicated software is very important. The small size of the ASIC's die (1.5 x 3.4 mm2), the pin-count (81), presence of multiple, mixed-signal power domains, the need to connect the IC to the silicon detector and the system operation in the presence of X-rays impose also very significant requirements for the printed circuit board.
Źródło:
Pomiary Automatyka Robotyka; 2011, 15, 7-8; 70-74
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method of measurement and reduction of the electromagnetic disturbances inducted by switching surges in LV circuits
Metoda pomiaru i redukcji zaburzeń elektromagnetycznych indukowanych przez przepięcia łączeniowe w obwodach nN
Autorzy:
Wąsik, Patryk D.
Powiązania:
https://bibliotekanauki.pl/articles/2070265.pdf
Data publikacji:
2021
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
EMI
circuit breaker
fast measurement method
LV circuits
wyłącznik nadprądowy
szybka metoda pomiarowa
obwody nN
Opis:
This paper presents a fast, reliable and portable method for measuring electromagnetic disturbances in LV circuits (overcurrent circuit breakers). The experiment was carried out under conditions reflecting the real measurement environment. The method was verified and confirmed by a series of measurements with passive components reducing the disturbance. The results of the measurements made it possible to obtain suitable EMI reduction solutions, which can be used to protect commutators or end consumers. The results obtained make it possible to apply the method to measurements of multichannel circuit breakers, in which measuring the turn-on time of individual channels is important for the correct operation of the devices.
W artykule przedstawiono szybką, niezawodną i przenośną metodę pomiaru zaburzeń elektromagnetycznych w obwodach nN (wyłączniki nadprądowe). Eksperyment przeprowadzono w warunkach odzwierciedlających rzeczywiste środowisko pomiarowe. Metoda została zweryfikowana i potwierdzona serią pomiarów z elementami pasywnymi redukującymi zaburzenia. Wyniki pomiarów pozwoliły na uzyskanie odpowiednich rozwiązań redukcji zaburzeń elektromagnetycznych. Dobrane komponenty mogą być wykorzystane do ochrony komutatorów lub odbiorników końcowych. Uzyskane wyniki pozwalają na zastosowanie metody do pomiarów wyłączników wielobiegunowych, w których pomiar czasu załączenia poszczególnych biegunów jest istotny dla poprawnej pracy urządzeń.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2021, 11, 4; 55--61
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System pomiarowy do badania stanów nieustalonych w obwodach QPC
Measurement system for investigation transient states in circuits
Autorzy:
Wawrzyniak, M.
Pająkowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/151911.pdf
Data publikacji:
2002
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
systemy pomiarowe
badania stanów nieustalonych
obwody z QPC
measurement systems
investigation transient states
circuits with QPC
Opis:
W artykule przedstawiono system pomiarowy służący do badań stanów nieustalonych w obwodach z QPC. W praktyce QPC (ang. Quantum Point Contacts) powstają pomiędzy zestykami przekaźników lub wyłączników mechanicznych. Efektem powstania QPC pomiędzy zestykami są skokowe zmiany przewodności zestyku obserwowane przy jego rozwieraniu. zmiany te powodują modyfikację dobrze znanych z praktyki i opisanych teoretycznie stanów nieustalonych w obwodzie. Do wytwarzania QPC zastosowano przekaźnik własnej konstrukcji. Ponadto przedstawiono przykładowe wyniki pomiarów stanów nieustalonych w obwodzie RLC z QPC wykonane za pomocą opisanego systemu pomiarowego.
The paper presents a measurement system for investigation transient states in circuits with Quantum Point Contacts. QPC is a formation between metallic contacts in commercial relays or mechanical switches. We have observed staircase characteristic of conductance of the contacts between the realy as a function of time. This effects significantly modifies well known transient states in circuits. We describe a home build relay construction. The realy was used to produce QPCs in circuits. We constructed an automated setup, which makes it possible to record current in a breaking contact. The paper presents result of measurements of transient states in RLC circuit with Quantum Point Contact, too.
Źródło:
Pomiary Automatyka Kontrola; 2002, R. 48, nr 7/8, 7/8; 113-116
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Schematy zastępcze i diagnostyki izolatora przepustowego transformatora
Equivalent circuits and diagnostics of bushing insulator of transformer
Autorzy:
Glinka, T.
Drak, B.
Kapinos, J.
Powiązania:
https://bibliotekanauki.pl/articles/1367899.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
izolatory przepustowe
transformatory
schematy zastępcze
pomiar tgδ
bushing insulators
transformers
equivalent circuits
measurement of tgδ
Opis:
This article presents the construction and diagnostics of high-voltage, paper-oil Cushing insulator in porcelain body. Such insulators are used in power transformers. Diagnostics of this insulators is based either on measurements of tgδ and of capacity C or on measurement of summary leakage current. Electrical equivalent circuits of the diagnosed insulation system are being presented. Moreover it is shown why this type of diagnostics is unreliable. More reliable diagnostic method is the measurements of the oil (DGA analysis).
W artykule przedstawiono budowę i diagnostykę izolatora przepustowego wysokiego napięcia papierowo-olejowego w osłonie porcelanowej. Izolatory tego typu są stosowane w transformatorach energetycznych. Diagnostyka izolatorów bazuje na pomiarach tgδ i pojemności C bądź na pomiarze sumarycznego prądu upływu. Przedstawiono elektryczne schematy zastępcze diagnozowanego układu izolacyjnego i wykazano dlaczego tego typu diagnostyka jest mało wiarygodna. Wskazano, że bardziej wiarygodną diagnostyką jest badanie oleju (analiza DGA).
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2015, 2, 106; 129-134
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automated measurement of rail circuits parameters and harmonics of return tractive current to improve safety of movement
Autorzy:
Serdyuk, T.
Gavrilyuk, V.
Powiązania:
https://bibliotekanauki.pl/articles/393964.pdf
Data publikacji:
2009
Wydawca:
Polskie Stowarzyszenie Telematyki Transportu
Tematy:
obwód torowy
prąd kodowany
harmoniczne
prąd trakcyjny
pomiar automatyczny
rail circuits
code current
harmonics
traction current
automated measurement
Opis:
A method of automated measurement of rail circuits parameters and harmonics of return traction current has been elaborated. The mathematical model of traction network is proposed and allowed us to involve the action of different sources of electromagnetic interference on the operation of rail circuits. The results of modelling allowed establishing that the rail circuits are exposed to a dangerous influence of return traction current near a locomotive and substation.
Źródło:
Archives of Transport System Telematics; 2009, 2, 3; 17-21
1899-8208
Pojawia się w:
Archives of Transport System Telematics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-14 z 14

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies