Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "magnetoelectropolishing" wg kryterium: Temat


Wyświetlanie 1-14 z 14
Tytuł:
Magnetic Fields for Electropolishing Improvement: Materials and Systems
Autorzy:
Hryniewicz, Tadeusz
Rokosz, Krzysztof
Rokicki, Ryszard
Powiązania:
https://bibliotekanauki.pl/articles/411721.pdf
Data publikacji:
2014
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Magnetic field
Magnetoelectropolishing MEP
Materials
Electrochemical systems
Opis:
The paper aims to present the main objectives for using magnetic fields to improve process of electropolishing (EP), firstly by focusing on materials and electrochemical systems. The general introduction has been concerned on the sample surface treated under pseudopassivity conditions, in the process generally known as magnetoelectropolishing (MEP). Long-term up-to-date experiments have shown profound changes observed on metals and alloys. The advantageous effects gained by applying MEP to metals and alloys cover: improvement of corrosion resistance, bio- and haemocompatibility, roughness by modification of their surfaces. The improvements are also referred to the mechanical properties of metals and alloys treated by MEP namely: removal of hydrogen, fatigue resistance enhancement, etc. Further developments and the effects of magnetic fields on electropolishing of metals and alloys are to be presented in the next publications.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2014, 4; 98-108
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania XPS powierzchni stali martenzytycznej 4H13 po magnetoelektropolerowaniu
XPS measurements of martensitic stainless steel 4H13 after magnetoelectropolishing
Autorzy:
Rokosz, K.
Hryniewicz, T.
Raaen, S.
Powiązania:
https://bibliotekanauki.pl/articles/316524.pdf
Data publikacji:
2012
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
magnetoelektropolerowanie
stal martenzytyczna
XPS
magnetoelectropolishing
martensitic steel
Opis:
Artykuł jest kontynuacją pracy opisującej wyniki badań XPS stali martenzytycznej 4H13 po standardowym elektrochemicznym polerowaniu bez mieszania [1]. Autorzy prezentują skład chemiczny warstwy wierzchniej po polerowaniu elektrochemicznym w polu magnetycznym. Wykonane badania uwidoczniają różnice warstw wierzchnich otrzymanych standardową metodą elektrochemicznego polerowania oraz metodą magnetoelektropolerowania.
The article is a continuation of the work covering the XPS results of 4H13 martensitic steel after electrochemical polishing without mixing [1]. The authors present the chemical composition of the surface layer after electrochemical polishing in a magnetic field. The results show comparison of surface layers obtained by standard electrochemical polishing and magnetoelectropolishing.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2012, 13, 5; 421-428
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On the Nitinol properties improvement after electrochemical treatments
Autorzy:
Hryniewicz, Tadeusz
Rokicki, Ryszard
Powiązania:
https://bibliotekanauki.pl/articles/1178042.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Nitinol
SMA
electropolishing (EP)
fatigue resistance
inclusions
magnetoelectropolishing (MEP)
Opis:
Shape Memory Alloys (SMAs) are a group of intermetallic compounds, which can undergo deformation at one temperature, and then recover their original undeformed shape upon heating above their transformation temperature. Superelasticity occurs just above the alloy’s transformation temperature in a very narrow range. In this case no heating is necessary to cause the deformed shape to recover upon load relieve to its original undeformed shape. It has to be emphasized that nitinol exhibits enormous elasticity when compared with other medical metal alloys. In recent years, the use of nitinol (NiTi), almost equiatomic binary (50:50 ratio) intermetallic compound of nickel and titanium, has been steadily growing, particularly in medical and dental devices markets. However, broader and further application of nitinol has been slowed down by leaking nickel and unavoidable inclusions during producing in this compound. This work is to present some electrochemical treatment methods in view of reducing of both these phenomena. It appears that changing electrical conditions of electropolishing (EP) above the plateau region (EP+) may improve the quality of surface obtained on NiTi of over 60% in comparison with as-received (AR) nitinol part. What’s more, introducing a magnetic field into the electrolysis system results in numerous positive features of nitinol surface and increase of mechanical properties. Thus the magnetoelectropolishing (MEP) process appears to increase higher the fatigue resistance of the treated NiTi part. The experiments carried out on chirurgical needles show an unusual triple (and higher) growth in resistance to bending until fracture. Further increase in fatigue resistance is usually limited by different size inclusions appearing on the nitinol part surface under magnetoelectropolishing (MEP).
Źródło:
World Scientific News; 2018, 95; 52-63
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
XPS Analysis of nanolayers obtained on AISI 316L SS after Magnetoelectropolishing
Autorzy:
Rokosz, Krzysztof
Hryniewicz, Tadeusz
Powiązania:
https://bibliotekanauki.pl/articles/1192093.pdf
Data publikacji:
2016
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
XPS Analysis
Magnetoelectropolishing (MEP)
AISI 316L SS
Nanolayers
Opis:
In the present paper, the passive layers' chemical compositions of AISI 316L austenitic stainless steel samples after three treatments, such as mechanical/abrasive polishing (MP), standard electropolishing (EP) and magnetoelectropolishing (MEP) are displayed. For the surface studies after each treatment, XPS analysis was performed. It has been noted that after MP treatment the Cr/Fe ratio in the passive layer is the lowest and equals to about 1, whereas after the MEP it is close to 3. Additionally, it has to be reported that the passive layers after MP consist mainly of Cr2O3 and Fe2O3, after a standard EP treatment – of CrOOH and FeOOH, and after MEP – of Cr(OH)3 and FeOOH compounds. Concerning the surface layer compositions, in the passive layer formed after MP the detected iron consisted partly of Fe0 (46.5 at %) and partly of iron compounds Fe2+ and Fe3+ (53.5 at %), whereas the detected chromium consisted of Cr0 (16.5 at %) and mostly of chromium compounds Cr3+ (80.8 at%), with a small amount of Cr6+ (2.7 at %). In case of the nanolayer after EP treatment, the detected iron consisted of Fe0 (39.5 at %) and iron compounds Fe2+ and Fe3+ (60.5 at %), whereas the detected chromium consisted in a small amount of Cr0 (6.6 at %), and mostly chromium compounds Cr3+ (83.8 at %) with some Cr6+ (9.6 at %). The XPS analysis of nanolayer formed on AISI 316L after MEP indicates that the detected iron consisted partly of Fe0 (27.1 at %) and mostly of iron compounds Fe2+ and Fe3+ (72.9 at %) whereas the detected chromium contained Cr0 (18 at %) and chromium compounds of Cr3+ (76 at %) and Cr6+ (6 at %).
Źródło:
World Scientific News; 2016, 37; 232-248
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Highly improved Nitinol biomaterial devices by magnetoelectropolishing (MEP)
Autorzy:
Hryniewicz, Tadeusz
Rokicki, Ryszard
Powiązania:
https://bibliotekanauki.pl/articles/1166214.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Biocompatibility
Fatigue resistance
Nitinol biomaterial
Surface roughness
XPS
magnetoelectropolishing
Opis:
In recent years, the use of Nitinol as a metallic biomaterial being compound of nickel and titanium, has been steadily growing, particularly in medical and dental devices markets. However, further application of Nitinol has been slowed down due to leaching nickel and unavoidable inclusions appearing on the surface during manufacture of this intermetallic compound. Electropolishing of Nitinol biomaterial samples as-received (AR) was carried out under different conditions: (a) on the plateau level (EP), (b) above the plateau (EP+), and (c) in the magnetic field (MEP). This work is to present magnetoelectropolishing (MEP) as an electrochemical processing method able to significantly improve the Nitinol biomaterial properties. Following our previous SEM/EDS studies, and corrosion resistance improvement of Nitinol, in this work XPS and XRD study methods were used. First of all, as indicated by XPS study results concerning biocompatibility, it was proved that MEP leaves Nitinol surface enriched in oxygen and with nickel reduced to zero. Thus the titanium oxides, generally TiO2, are formed on Nitinol surface. It appears that by introducing a magnetic field into the electrolysis system, another effect relying on a considerable increase of Nitinol mechanical properties is obtained. The experiments carried out on surgical needles show an unusual multiple growth in resistance to bending until fracture. Further increase in fatigue resistance is usually limited by different size of inclusions which happen to appear on the Nitinol part surface. Moreover, in this work also a simple method is proposed to reject the Nitinol parts, with the inclusions detected on the biomaterial surface, before their application.
Źródło:
World Scientific News; 2018, 106; 175-193
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modification of Nitinol Biomaterial for Medical Applications
Autorzy:
Hryniewicz, Tadeusz
Rokicki, Ryszard
Powiązania:
https://bibliotekanauki.pl/articles/1177981.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Nitinol biomaterial
electropolishing
fatigue resistance
magnetoelectropolishing (MEP)
modification methods
sterilization
Opis:
In the paper, a review of modification methods which have been applied to Nitinol intermetallic compound used as biomaterial for medical applications, is carried out. A variety of methods used for Nitinol improvement, beginning from its manufacture, covers mechanical treatment, heat treatment, chemical processing including water boiling, electropolishing, plasma ion implantation, coating to improve the corrosion resistance, minimize nickel leaching, improve osseointegration, and/or vascular compatibility, sterilization and disinfection. Nitinol alloying by addition of a third element to replace Ti or Ni has an enormous effect on phase transformation, corrosion resistance and biocompatibility of the newly created ternary Nitinol alloy. Unfortunately, the ternary nitinol alloys – apart from NiTiCu in actuators and NiTiCr in wires used as a pulling-pushing tool in minimally invasive spine operation – have not found a widespread industrial application yet. One of the most effective surface finishing operations used for metallic biomaterials, with a special attention directed to Nitinol, appears to be magnetoelectropolishing (MEP). A uniform magnetic field used in MEP process can be generated by permanent magnets or by electromagnets. MEP leads to refinement of surface chemical composition impossible to achieve by standard electropolishing. During MEP of alloys and intermetallic compounds, ferromagnetic elements, such as Fe (from stainless steels) or Ni, are primarily removed from the surface so that the passive film on Nitinol is totally composed of titanium oxide. One more unique feature of metal samples after MEP is their de-hydrogenation noticed both in stainless steels, niobium, titanium and Nitinol. In fact, the fatigue resistance of Nitinol after MEP referred to as-received, dependent on the refinement and displacement of inclusions, increases from three to seven times.
Źródło:
World Scientific News; 2018, 96; 35-58
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On the wear inspection and endurance recovery of Nitinol endodontic files
Kontrola zużycia i poprawa jakości nitinolowych wierteł endodontycznych
Autorzy:
Hryniewicz, T.
Rokosz, K.
Powiązania:
https://bibliotekanauki.pl/articles/156461.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wiertła endodontyczne
nitinol
magnetoelektropolerowanie
SEM
interferometria
Endodontic rotary files
magnetoelectropolishing
interferometry
Opis:
The aim of this study was to reveal the effects of operation of endodontic rotary files during a normal use and the possibilities for their endurance recovery. The effect of magnetoelectropolishing on the basic surface, and mechanical properties of Nitinol endodontic rotary files has been also studied. The investigation covered surface interferometry measurements, and SEM studies referred to two groups of endodontic instruments: ready-to-use and/or as-received (AR) tools, and magnetoelectropolished (MEP) instruments, meaning treated by electropolishing in a magnetic field. Overall, magnetoelectropolished (MEP) instruments indicated significantly better surface characteristics than those as-received (AR). Our earlier studies have revealed several better and improved surface characteristics of Nitinol samples treated with MEP in comparison with those electropolished under standard EP conditions and as-received (AR) ones. Specifically it has been found that magnetoelectropolishing MEP process may improve the surface, corrosion, and fatigue characteristics of Nitinol samples. When viewing the as-received (AR) instruments with SEM, and measuring the instrument treated surface by interferometry, the evidences of milling grooves, cracks, pits, and metal rollover were observed, contrary to the endodontic file surface after magnetoelectropolishing (MEP). The MEP process has improved most of surface characteristics, having beneficial effects in prolonging the fatigue life of samples. The benefits of MEP process are likely to be caused by a reduction in surface irregularities and essential changes in surface film properties.
W pracy ukazano warunki pracy i sposoby zużycia nitinolowych narzędzi endodontycznych oraz możliwości poprawy ich trwałości / jakości. Badania obejmowały SEM i interferometrię narzędzi uszkodzonych w procesie powiększania kanału zębnego, oraz narzędzi po magnetoelektropolerowaniu (MEP). Zużycie narzędzi następuje głównie w wyniku zmęczenia materiału i zależy od ukształtowania kanału zębnego. Wstępne badania wykazują, że proces MEP, poprzez zmiany w warstwie wierzchniej, poprawia mechaniczne właściwości Nitinolu.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 4, 4; 247-250
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
XPS measurements of AISI 430 SS surface after electropolishing operations in a transpassive region of polarisation characteristics
Badania XPS powierzchni stali ferrytycznej AISI 430 po operacjach elektropolerowania w transpasywnym obszarze charakterystyk polaryzacyjnych
Autorzy:
Hryniewicz, T.
Rokosz, K.
Raaen, S.
Powiązania:
https://bibliotekanauki.pl/articles/156467.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
ferrytyczna stal AISI 430
magnetoelektropolerowanie (MEP)
XPS measurements
ferritic stainless steel
magnetoelectropolishing
Opis:
The paper presents results of measuring the chemical composition of the passive film formed on the ferritic steel AISI 430 SS after mechanical and electrochemical treatments. XPS (X-ray Photoelectron Spectroscopy) measurements were taken to obtain the chemical composition of the passive film on AISI 430 SS. The study results show that the ratio of the chromium compounds to iron compounds (Cr/Fe) in the passive film varies depend on the kind of surface treatment, starting from 0.4 after abrasive polishing (MP), up to 2.59 after standard electropolishing (EP) operation. The results of Cr/Fe ratio after electropolishing with electrolyte stirring (MIX) and these after magnetoelectropolishing (MEP) are between the two values. It was found that after electrochemical treatments the main compounds in the passive film consisted of Fe2O3, FeOOH, Cr2O3, Cr(OH)3.
W artykule przedstawiono wyniki pomiarów składu chemicznego warstwy pasywnej wytworzonej na stali ferrytycznej AISI 430 po polerowaniu ściernym oraz polerowaniu elektrolitycznym. Skład chemiczny warstwy wierzchniej stali AISI 430 zbadano przy użyciu fotoelektronowej spektroskopii promieniami Roentgena (XPS). Wyniki badań pokazują, że stosunek zawartości związków chromu do związków żelaza (Cr/Fe) w warstwie pasywnej zmienia się w zależności od rodzaju obróbki powierzchniowej, poczynając od 0.4 po polerowaniu ściernym (MP), do 2,59 po standardowym polerowaniu elektrolitycznym (EP). Wyniki Cr/Fe po elektropolerowaniu z mieszaniem (MIX) i po magnetoelektro-polerowaniu (MEP) mieszczą się pomiędzy tymi wartościami. Na podstawie badań XPS stwierdzono, że warstwa wierzchnia stali składa się ze związków Fe2O3, FeOOH, Cr2O3, Cr(OH)3
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 1, 1; 126-129
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurements of nanohardness and elasticity modulus of titanium after magnetoelectropolishing
Pomiary nanotwardości i modułu sprężystości tytanu po magnetoelektropolerowaniu
Autorzy:
Hryniewicz, T.
Rokosz, K.
Valicek, J.
Rokicki, R.
Harnicarova, M.
Vylezik, M.
Powiązania:
https://bibliotekanauki.pl/articles/153005.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
nanoindentation
titanium biomaterials
nanohardness
Young's modulus
magnetoelectropolishing (MEP)
nanoindentacja
tytan
magnetoelektropolerowanie (MEP)
nanotwardość
moduł Younga
Opis:
Nanohardness is one of the main mechanical properties of the studied metal surface after electropolishing operations. The nanoindentation measurements were performed on CP-titanium biomaterial after its treatment under a standard electropolishing (EP) and magnetoelectro-polishing (MEP) conditions, with abrasive polishing (MP) performed on the samples for reference. In the studies, both the Young’s modulus of elasticity and nanohardness were investigated. It was found that the mechanical properties of titanium biomaterial indicated an evident dependence on the type and conditions of surface treatment. After magnetoelectropolishing (MEP) operation a considerable change in mechanical properties of the same Ti biomaterial was observed. One may state that the mechanical properties obtained on the titanium samples both after abrasive polishing (MP) and after a standard electropolishing (EP) are very different from those gained on the magnetoelectropolished titanium sample.
Nanotwardość jest jedną z ważniejszych cech mechanicznych powierzchni metali po obróbce elektropolerowaniem. W tradycyjnych badaniach twardości materiału, diamentowa końcówka wgłębnika służy badaniu twardości i modułu sprężystości. Pod obciążeniem wgłębnika następują odkształcenia sprężyste i plastyczne. Dobór wielkości obciążenia uzależniony jest od celu badania – samego materiału, czy też warstewek pasywnych powstałych na powierzchni metalu po określonej obróbce wykończającej. W artykule przedstawiono wyniki pomiarów metodą nanoindentacji próbek tytanu o czystości komercyjnej po polerowaniu elektrolitycznym w warunkach standardowych (EP), i magnetoelektro-polerowaniu (MEP), oraz po polerowaniu ściernym (MP) próbek, które posłużyły jako odniesienie. Badano moduł sprężystości Younga oraz nanotwardość materiału. Wyniki badań pokazują, że własności mechaniczne tytanu zależą od rodzaju i warunków obróbki wykończającej. Po magnetoelektropolerowaniu (MEP) wyniki nanoindentacji różnią się zasadniczo od analogicznych wyników uzyskanych po standardowym elektropolerowaniu (EP) i po polerowaniu ściernym (MP). Taka zmiana zasadniczo wpływa na poprawę odporności na przeginanie, zginanie i skręcanie biomateriału.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 7, 7; 676-679
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On the biological response of austenitic stainless steels after electrochemical -EP and MEP- polishing
Autorzy:
Hryniewicz, Tadeusz
Lewicka-Rataj, Katarzyna
Rokosz, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/1179275.pdf
Data publikacji:
2017
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
austenitic stainless steels
bacteria Escherichia coli
electrochemical polishing
electropolishing EP
magnetoelectropolishing MEP
statistical approach
water contamination
Opis:
The austenitic cold-rolled AISI 316L stainless steel was used for the studies. Corrosion resistance measurements were performed on the samples after three types of treatments: abrasive finishing (MP), standard electropolishing (EP), and magnetoelectropolishing (MEP). They were carried out in Ringer's solution at a room temperature, indicating a considerable difference in the breaking potential Epit values, dependent on surface treatment. Two groups of samples, those after EP and MEP, were submerged in broth culture wild strain of Escherichia coli from contaminated river water. Images of the steel samples submerged for 2 and 4 hours are displayed in the paper. A statistical approach has been performed. In each case the number of bacteria deposited on the MEP steel samples was higher in comparison with that one noticed on EP samples, increasing much faster with time on the MEP ones.
Źródło:
World Scientific News; 2017, 80; 284-296
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Auger/AES surface film measurements on AISI 316L biomaterial after magnetoelectropolishing
Analiza Augera/AES warstwy wierzchniej stali AISI 316L jako biomateriału po magneto-elektropolerowaniu
Autorzy:
Hryniewicz, T.
Rokosz, K.
Micheli, V.
Powiązania:
https://bibliotekanauki.pl/articles/153052.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
spektroskopia elektronów Augera AES
magnetoelektropolerowanie (MEP)
analiza warstwy wierzchniej
Auger Electron Spectroscopy (AES)
magnetoelectropolishing (MEP)
surface film analysis
Opis:
Auger Electron Spectroscopy (AES) was used to study the elemental composition of surface film formed on AISI 316L biomaterial after its magnetoelectropolishing (MEP) under varied conditions of the magnetic field intensity and the process current density applied. The results of the analyses are compared with those obtained on the samples after a conventional electropolishing (EP) under two different current densities. Changes in general elements' contents of the steel surface film, concerning Fe, O, Cr, and Ni, after EP and MEP processes, have been analyzed. The studies allowed to find out MEP parameters at which the important components/elements of the surface film reach maximum (Cr) and/or minimum (Ni) values. It appears the AES results, mainly with higher amounts of Cr and lower Ni, obtained on 316L biomaterial samples after MEP under selected parameters, are more advantageous than the ones after EP. That way the AES measurements results allowed to indicate the MEP process to be more advantageous for AISI 316L biomaterial treatment.
Spektroskopia elektronów Augera (AES) posłużyła do zbadania składu warstwy wierzchniej (WW) stali AISI 316L jako biomateriału, po magnetoelektropolerowaniu (MEP) przy różnych warunkach natężenia pola magnetycznego i gęstości prądu. Wyniki analiz porównano z wynikami AES uzyskanymi na próbkach stali po konwencjonalnym elektropolerowaniu (EP) przy dwu gęstościach prądu. Analizie poddano zmiany składu chemicznego WW stali, głównie Fe, O, Cr, i Ni, po EP i MEP. Badania pozwoliły na określenie maksymalnych wartości Cr i minimalnych wartości Ni po EP i MEP przy wybranych parametrach. Wyniki pomiarów AES pozwoliły na określenie warunków MEP, przy których skład WW jest najbardziej korzystny, ze względu na wzrost zawartości Cr i zmniejszenie Ni. Wykazano, że proces MEP znacznie korzystniej niż EP wpływa na uzyskanie oczekiwanego stanu WW stali 316L jako biomateriału.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 6, 6; 609-614
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nanoindentation measurements of AISI 316L SS biomaterial samples after annual immersion in Ringers solution followed by electrochemical polishing in a magnetic field
Badania nanoindentacji biomateriału stali AISI 316L po polerowaniu elektrolitycznym w polu magnetycznym i całorocznym zanurzeniu próbek w roztworze Ringera
Autorzy:
Rokosz, K.
Hryniewicz, T.
Valicek, J.
Harnicarova, M.
Vylezik, M.
Powiązania:
https://bibliotekanauki.pl/articles/151760.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
nanoindentacja
biomateriał AISI 316L
magnetoelektropolerowanie (MEP)
nanotwardość
moduł Younga
nanoindentation
316L biomaterial
magnetoelectropolishing (MEP)
nanohardness
Young's modulus
Opis:
Nanoindentation studies were performed on AISI 316L austenitic stainless steel after its electropolishing under varied conditions and keeping such obtained samples in the Ringer's solution for a year period of time. The Young's modulus of elasticity and hardness were investigated. The mechanical properties of AISI 316L stainless steel biomaterial demonstrated an evident dependence on the treated electropolishing conditions. After magnetoelectropolishing (MEP) treatment some improvement in mechanical properties of the same steel biomaterial is observed in comparison with the ones after a standard electropolishing (EP).
wykonanych z austenitycznej stali kwaso-odpornej AISI 316L. Próbki poddano polerowaniu elektrolitycznemu w warunkach standardowych (EP), oraz elektropolerowaniu w polu magnetycznym (MEP). Tak przygotowane próbki zostały zanurzone w roztworze Ringera i przetrzymane w temperaturze około 25 °C przez okres jednego roku. Po roku czasu próbki wyjęto, wypłukano w wodzie destylowanej i wysuszono. Następnie wykonano nanoindentację na urządzeniu do testowania 950 TriboIndenter™. Badano moduł sprężystości Younga oraz nanotwardość materiału. Wyniki badań pokazują, że własności mechaniczne stali AISI 316L zależą od warunków polerowania elektrolitycznego (EP). Po magnetoelektropolerowaniu (MEP) następuje poprawa niektórych własności mechanicznych biomateriału AISI 316L w porównaniu z wynikami uzyskanymi po standardowym elektropolerowaniu (po rocznym zanurzeniu próbek w roztworze Ringera). Wyniki badań są zgodne z dotychczasowymi rezultatami autorów i wskazują na możliwości modyfikacji wybranych właściwości mechanicznych biomateriałów metalowych, w tym przypadku - stali AISI 316L.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 5, 5; 460-463
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Significant improvement of AISI 316L SS biomaterial surface after magnetoelectropolishing MEP: XPS measurements
Istotne polepszenie stali AISI 316L jako biomateriału po magnetoelektropolerowaniu: pomiary XPS
Autorzy:
Hryniewicz, T.
Rokosz, K.
Powiązania:
https://bibliotekanauki.pl/articles/151152.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
AISI 316L SS
magnetoelectropolishing (MEP)
XPS measurements
Cr-X/Fe-X ratio
pomiary XPS
stal austenityczna AISI 316L
magnetoelektropolerowanie (MEP)
Opis:
The main purpose of the work is to show a significant improvement of AISI 316L biomaterial after magnetoelectropolishing MEP. The studies were realized by taking XPS measurements on the steel samples after three surface treatments: abrasive polishing MP, standard electropolishing EP, and magnetoelectropolishing MEP to reveal the great advantage of magnetoelectropolished biomaterial over the 316L steel surface properties after other finishing operations. Moreover, a variety of electropolishing conditions (EP – without stirring, MIX – using electrolyte mixing) and parameters (current density from the plateau level EP, up to EP1000, meaning 1000 A/dm2) were considered and studied. Afterwards, basing on the XPS survey, the high resolution spectra were determined concerning three general elements of the 316L steel: iron, chromium, and oxygen. At the end, chromium compounds to iron compounds ratio (Cr-X/Fe-X) and Cr/Fe ratio could be calculated to reveal the optimum conditions of the studies. The main achievement of the work is proving the outstanding features of stainless steel biomaterial after MEP.
W artykule przedstawiono wyniki pomiarów składu chemicznego warstwy pasywnej wytworzonej na stali austenitycznej AISI 316L po polerowaniu elektrochemicznym w warunkach bez mieszania elektrolitu (EP), z mieszaniem elektrolitu (MIX), oraz po magnetoelektropolerowaniu (MEP). Wszystkie próby polerowania elektrochemicznego prowadzono w mieszaninie kwasów ortofosforowego i siarkowego o składzie objętościowym 6:4 w temperaturze (655) C przy zastosowaniu gęstości prądu na poziomie plateau, 50 A/dm2, 200 A/dm2, i 1000 A/dm2 oraz jednakowym czasie obróbki wynoszącym 3 minuty. Proces magnetoelektropolerowania MEP prowadzono w stałym polu magnetycznym (B ≈ 350 mT). Dodatkowo, kilka prób MEP wykonano z parametrami i ≈ 200 A/dm2, w polu magnetycznym o natężeniu B ≈ 420 mT. Skład chemiczny warstwy wierzchniej stali AISI 316L zbadano przy użyciu fotoelektronowej spektroskopii promieniami Roentgena (XPS) po trzech obróbkach: polerowaniu ściernym MP, polerowaniu elektrolitycznym EP, oraz po MEP. Warunki elektropolerowania obejmowały mieszanie elektrolitu (MIX), lub jego brak (EP), oraz gęstość prądu od wartości plateau do 1000 A/dm2 (EP1000). Po polerowaniu, w oparciu o pomiary XPS, uzyskano widma wysokiej rozdzielczości dotyczące trzech głównych pierwiastków stali 316L: żelaza, chromu i tlenu. Podstawowe zadanie polegało na wyznaczeniu zmian w stosunku zawartości chromu do żelaza w warstwie wierzchniej badanej stali austenitycznej AISI 316L, w zależności od warunków obróbki elektrochemicznej. Przedstawiono widma XPS wysokiej rozdzielczości chromu Cr 2p oraz żelaza Fe 2p badanej stali po poszczególnych obróbkach elektrochemicznych. Tabelarycznie przedstawiono analizę danych XPS przez dopasowanie jednopikowe O 1s. Następnie pokazano skład chemiczny warstwy wierzchniej obliczony w oparciu o trzy sygnały: Fe 2p, Cr 2p, O 1s oraz podano stosunki Cr-X/Fe-X i Cr/Fe. Metoda badania XPS składu powierzchni została przedstawiona we wcześniejszych pracach Autorów, przy czym sposób podejścia do dwupikowej analizy zaprezentowano przykładowo na pierwszych dwu rysunkach niniejszej pracy. Badania XPS przeprowadzono na spektrometrze SCIENCE SES 2002. Widma rentgenowskie zapisywano przy normalnej emisji. W celu optymalizacji stosunku sygnału do szumu, jeden cykl pomiarowy XPS obejmował 10 przejść. Następnie wyznaczono stosunek Cr/Fe dla wszystkich wykonanych pomiarów. Do analizy danych XPS posłużono się programem Casa XPS 2.3.14. Wykorzystując program Casa XPS 2.3.14, zgodnie z zaproponowanym algorytmem, dokonano interpretacji wyników XPS. W końcu wyznaczono stosunki związków (Cr-X/Fe-X) i Cr/Fe celem pokazania optimum. Głównym osiągnięciem pracy jest pokazanie znacznej poprawy właściwości powierzchni stali 316L po MEP.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 12, 12; 1308-1312
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetoelectropolishing: modern and effective method of AISI 316L SS surface finishing
Magnetoelektropolerowanie jako nowa i efektywna metoda obróbki powierzchniowej stali austenitycznej AISI 316L
Autorzy:
Rokosz, K.
Hryniewicz, T.
Powiązania:
https://bibliotekanauki.pl/articles/155250.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
AISI 316L SS
magnetoelectropolishing (MEP)
XPS measurements
potentiodynamic measurements
nanoindentation
nanohardness
reduced Young's modulus
Cr-X/Fe-X ratio
magnetoelektropolerowanie (MEP)
pomiary XPS
pomiary potencjodynamiczne
nanoindentacja
nanotwardość
zredukowany moduł Younga
stal austenityczna AISI 316L
stosunek Cr-X/Fe-X
Opis:
The results presented in the paper have been obtained during several last years. They represent chemical composition of the passive layer measurements, its uniform and pitting corrosion resistance as well as nanohardness and reduced Young's modulus for the austenitic steel AISI 316L. The main goal is to present a new and modern method of finishing - electrochemical polishing in a magnetic field MEP with respect to the standard abrasive polishing MP and electrochemical one EP. The chemical composition of the surface layer of AISI 316L were examined using X-ray photoelectron spectroscopy (XPS); the corrosion rates were determined from potentiodynamic polarization tests. Nanohardness and reduced Young's modulus were obtained from nanoindentation measurements. The main achievement of the paper is revealing the chemical and mechanical properties of the surface layer formed after polishing MEP against the MP and EP treatments.
W artykule przedstawiono kompaktowo wyniki kilkuletnich badań i pomiarów składu chemicznego warstwy pasywnej, jej odporności na korozję równomierną oraz wżerową, jak i nanotwardość oraz zredukowany moduł Younga dla austenitycznej stali AISI 316L. Autorzy zaprezentowali nowoczesną metodę obróbki wykończeniowej – elektrochemiczne polerowanie w polu magnetycznym MEP w odniesieniu do standardowej obróbki ściernej MP oraz elektrochemicznej EP. Skład chemiczny warstwy wierzchniej stali AISI 316L zbadano przy użyciu fotoelektronowej spektroskopii promieniami Roentgena (XPS); szybkości korozji wyznaczono z badań potencjodynamicznych, a nanotwardość oraz zredukowany moduł Younga z badań nanoindentacyjnych. Głównym przedmiotem pracy jest prezentacja wpływu pola magnetycznego na własności chemiczne oraz mechaniczne warstwy wierzchniej powstałej po polerowaniu MEP na tle obróbek MP i EP. Przeprowadzone badania wykazały, że odporność na korozję wżerową powierzchni po elektrochemicznym polerowaniu w polu magnetycznym MEP wzrasta około dwukrotnie w stosunku do standardowego polerowania elektrochemicznego EP, co potwierdzają również wyniki badań XPS, obrazujące stosunek związków chromu do związków żelaza. Odnotowano również zmianę nanotwardości oraz zredukowanego modułu Younga warstw wierzchnich otrzymanych poprzez obróbkę EP i MEP, co dodatkowo potwierdza istotny wpływ pola magnetycznego na właściwości zarówno elektrochemiczne jak i mechaniczne warstwy wierzchniej.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 12, 12; 1304-1307
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-14 z 14

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies