Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "magnetic shielding" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Measures to reduce the residual field and field gradient inside a magnetically shielded room by a factor of more than 10
Autorzy:
Voigt, J.
Knappe-Grüneberg, S.
Schnabel, A.
Körber, R.
Burghoff, M.
Powiązania:
https://bibliotekanauki.pl/articles/220358.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
magnetic shielding
magnetic shielded room
msr
residual field
residual field gradient
degaussing
demagnetization
Opis:
Very low residual magnetic field and field gradients are essential for a number of high resolution fundamental physical experiments and for further improvement of very sensitive magnetic measurement devices. The scope ranges from spin precession experiments, e.g. with 3He or neutrons, to biomagnetic measurements, like magnetoencephalograms, and to low field MR spectroscopy. One method of reducing environmental magnetic noise is to use a magnetically shielded room (MSR). Here, measures are demonstrated to improve residual field and field gradient inside a common MSR by a factor of more than 10 by a specific degaussing procedure, material selection of prefabricated parts and active shielding. The process is independent of the shielding factor and works also properly for heavily shielded rooms.
Źródło:
Metrology and Measurement Systems; 2013, 20, 2; 237-248
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on impact of HTS winding configuration on energy value and magnetic field distribution in SMES
Badania wpływu konfiguracji uzwojenia HTS na energię i rozkład pola magnetycznego nadprzewodnikowego zasobnika energii
Autorzy:
Kondratowicz-Kucewicz, B.
Powiązania:
https://bibliotekanauki.pl/articles/159285.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
nadprzewodnikowy zasobnik energii SMES
ekranowanie pola magnetycznego
rozkład pola magnetycznego
SMES
magnetic shielding
magnetic field distribution
Opis:
Artykuł poświęcony jest nadprzewodnikowemu zasobnikowi energii na przykładzie modelu fizycznego zasobnika zbudowanego w Pracowni Technologii Nadprzewodnikowych Instytutu Elektrotechniki. Rozważany problem dotyczy wyboru konfiguracji uzwojenia nadprzewodnikowego, która może zapewnić wymaganą wartość energii zasobnika przy ograniczonej przestrzeni pola magnetycznego. Przeanalizowano konfiguracje uzwojeń w układzie solenoidalnym i toroidalnym. Zaproponowano metodę ekranowania pola magnetycznego badanego elektromagnesu za pomocą elementów ferromagnetycznych w kilku konfiguracjach. Przedstawiono rezultaty obliczeń metodą elementów skończonych rozkładu pola magnetycznego i gromadzonej energii w uzwojeniu dla rozpatrywanych konfiguracji ekranujących w modelu numerycznym zbudowanym w programie Flux-3D. Wykazano, że dla badanego modelu nadprzewodnikowego zasobnika o energii 34 kJ w temperaturze 13 K, możliwe jest zastosowanie konfiguracji elementów ekranujących pole magnetyczne, która pozwoli na ograniczenie strefy pola magnetycznego o natężeniu przekraczającym wartości dopuszczalne oraz zwiększenie energii zasobnika o 14%.
The article describes a physical model of Superconducting Magnetic Energy Storage System (SMES) built in the Laboratory of Superconducting Technology in the Electrotechnical Institute. The considered problem concerns the choice of the superconducting winding configuration, which can be responsible for the required energy value in a limited space of the strong magnetic field. Possible configurations of the windings were analysed with particular focus on the solenoid and the toroidal configuration. The results of the calculations of the magnetic field distribution and the energy accumulated in the coil for the considered shield configuration have been described. It was shown that for the tested SMES model with energy of 34 kJ at temperature 13 K, it is possible to use such magnetic field shielding configuration, which allows to limit the magnetic field zone with an intensity exceeding the limit values and energy increase by 14%.
Źródło:
Prace Instytutu Elektrotechniki; 2018, 278; 73-90
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Benzen i metan jako wzorce przesunięcia chemicznego 1 H I 13 C NMR w obliczeniach teoretycznych
Benzene and methane as a and 13 H I 13 C NMR chemical shift references in theoretical calculations
Autorzy:
Rzepiela, Kacper
Gajda, Tomasz
Buczek, Aneta
Broda, Małgorzta A.
Kupka, Teobalt
Powiązania:
https://bibliotekanauki.pl/articles/172062.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Chemiczne
Tematy:
tensor ekranowania magnetycznego
wzorce przesunięcia chemicznego
benzen
metan
cytozyna
izopren
nuclear magnetic shielding tensor
chemical shift references
benzene
methane
cytosine
isoprene
Opis:
NMR spectroscopy belongs to the most versatile techniques used in chemical laboratory for testing the presence of various compounds and elucidation of their structure. In case of more complex natural products chemical intuition and experience applied to analysis of experimental spectra is often supported by theoretical modeling of NMR spectra. However, theoretical predictions should be reliable and the errors associated with the approximations inherent to the existing methods minimized. In this respect, systematic errors, present in calculation of isotropic nuclear magnetic shieldings of the studied molecule need to be minimized. Conversion of nuclear shieldings of the studied molecule to the corresponding chemical shifts is performed by using a calculated reference molecule. This way systematic errors partly cancel and the remaining inaccuracies are efficiently decreased by using a properly selected theoretical reference molecule. In this work we demonstrate the impact of calculation method (selected density functional) and basis set on the predicted isotropic nuclear magnetic shieldings of free benzene and methane in vacuum and in popular solvents using a simple PCM approach. We propose the use of B3LYP, OPBE density functionals and recently designed xOPBE one in combination with Pople’s and Dunning’s basis sets, as well as with the modified STO-3G one. The new, STO(1M)-3G basis set was designed by Leszczyński and co-workers for efficient prediction of 13C NMR parameters in large organic molecules. Two molecules were selected to demonstrate the performance of GIAO B3LYP, OPBE and xOPBE for prediction of 1H and 13C NMR chemical shifts in vacuum and solution in comparison with available experimental data.
Źródło:
Wiadomości Chemiczne; 2020, 74, 9-10; 609-627
0043-5104
2300-0295
Pojawia się w:
Wiadomości Chemiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methods for Canceling the Power Frequency Magnetic and Electric Fields at Pre-Specified Points on the Lines’ Corridors
Autorzy:
Saied, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/262789.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
power transmission lines
magnetic field
electrostatic interference
mitigation
shielding
Opis:
Methods are presented for the cancellation of the power line’s magnetic and electric fields at pre-specified points close to the line corridor. For canceling the magnetic field, three auxiliary conductors constituting two mitigating loops are used. Their configuration should be geometrically similar to the arrangement of the 3-phase power line’s conductors, with respect to the point at which a zero magnetic field is required. A procedure is suggested for the optimal selection of the scaling factor relating the power conductors’ and the mitigating conductors’ geometrical dimensions. In a case study, the magnetic field reduction varies between 100% near the zero-field point to 35% to the right of that point, with an optimal scaling factor of 0.15. Similar procedure can be used for cance¬ling the electric field at a pre-specified point. The three auxiliary conductors should carry charges proportional to those on the active conductors, but of opposite signs. Results show that the field at the specified point will be exactly zero, instead of the original value of 2.6kV/m. The three voltages required to supply the auxiliary conductors are 76.62, 62.53 and 51.50kV, with almost equal phase angles. The fact that the potentials of the three auxiliary conductors are almost in phase suggests the possibility of using one transformer with appropriate taps to supply them.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2009, 15, 2; 13-19
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetic field evaluation around 400 KV underground power cable under harmonics effects
Autorzy:
Boudjella, Houari
Ayad, Ahmed N. E. I.
Rouibah, Tahar
Larouci, Benyekhlef
Alghamdi, Thamer A. H.
Althobaiti, Ahmed
Ghoneim, Sherif S. M.
Tayeb, Abdelkader Si
Powiązania:
https://bibliotekanauki.pl/articles/2096182.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
electric power cables
magnetic field
harmonics
shielding
400 kV underground power system
kabel energetyczny
pole magnetyczne
harmoniczne
Opis:
Power lines or underground power cables generate electromagnetic interaction with other objects near to them. This study evaluates the magnetic field emitted by underground extra high voltage cables. The presented work aims to show a numerical simulation of the magnetic field of a buried 400 kV underground power line, which is used as a novel prototype in several countries at a short distance. The underground power cable study, in the presence of the current harmonics at different positions, with time variation by finite element resolution, using Comsol Multiphysics with Matlab software in two dimensions. The simulation results illustrate the magnetic flux density variation-in terms of amplitude and distribution as a function of different actual harmonics rates. The underground cable performance and magnetic field have affected by the harmonics effects. The maximum magnetic induction levels generated by significant harmonics are superior to the limits recommended by the international standard norms. In this paper, shielding has been used as an appropriate remedy to attenuate the magnetic field.
Źródło:
Diagnostyka; 2022, 23, 2; art. no. 2022209
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies