Tytuł:
Guidance Note: Risk Management of Workers With Medical Electronic Devices and Metallic Implants in Electromagnetic Fields
Autorzy:
Hocking, B.
Mild, K. M.
Powiązania:
https://bibliotekanauki.pl/articles/89915.pdf
Data publikacji:
2008
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
magnetic fields
microwave
interaction
pacemaker
artificial joint
Opis:
Medical electronic devices and metallic implants are found in an increasing number of workers. Industrial applications requiring intense electromagnetic fields (EMF) are growing and the potential risk of injurious interactions arising from EMF affecting devices or implants needs to be managed. Potential interactions include electromagnetic interference, displacement, and electrostimulation or heating of adjacent tissue, depending on the device or implant and the frequency of the fields. A guidance note, which uses a risk management framework, has been developed to give generic advice in (a) risk identification—implementing procedures to identify workers with implants and to characterise EMF exposure within a workplace; (b) risk assessment—integrating the characteristics of devices, the anatomical localisation of implants, occupational hygiene data, and application of basic physics principles; and (c) risk control—advising the worker and employer regarding safety and any necessary changes to work practices, while observing privacy.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2008, 14, 2; 217-222
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania powtarzalności złącza magnetycznego modułowych głowic stosowanych we współrzędnościowych maszynach pomiarowych
Testing of repeatability of magnetic joints of module probes of coordinate measuring machines
Autorzy:
Woźniak, A.
Osak, P.
Powiązania:
https://bibliotekanauki.pl/articles/208349.pdf
Data publikacji:
2009
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
współrzędnościowe maszyny pomiarowe
zespół głowicy pomiarowej
złącze magnetyczne
coordinate measuring machine
probing system
magnetic joint
Opis:
W artykule zaproponowano procedurę badania powtarzalności pozycjonowania złącza magnetycznego modułowych głowic stosowanych we współrzędnościowych maszynach pomiarowych. Przedstawiono również wyniki badań eksperymentalnych kilku najbardziej popularnych głowic umożliwiających szybką wymianę trzpienia pomiarowego: Vast Gold (Zeiss), Vast XXT (Zeiss), TP20 (Renishaw).
In this paper, a method for testing the repeatability of magnetic joints of probes for coordinate measuring machines (CMM) will be proposed. The basic principle of the method as well as experimental results from testing the Vast GOLD, Vast XXT and TP20 probe will be presented.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2009, 58, 1; 315-325
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wielkości szpary stawowej przy pomocy tomografii komputerowej i rezonansu magnetycznego
Studying the size of the articular cavity by using computed tomography and magnetic resonance
Autorzy:
Banasiewicz, J.
Rynkiewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/98933.pdf
Data publikacji:
2013
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
szpara stawowa
staw biodrowy
tomografia komputerowa
rezonans magnetyczny
articular cavity
hip joint
computer tomography
magnetic resonance
Opis:
W pracy poruszono problem dotyczący pomniejszania się wielkości szpary stawowej w stawie biodrowym,a zarazem wpływu tego niepożądanego zjawiska na ruchliwość kończyną dolną. Stosując m.in. techniki diagnostyki obrazowej, szpary stawowe można poddawać badaniom, a na podstawie ich analizy określać stan diagnozowanego stawu.
This article describes the problem involving decrease of articular cavity size in the hip joint, and also the effect of that phenomenon on lower limb movements. Using diagnostic imaging, articular cavities can be examined, and on the basis of their analysis determine the condition of the target joint.
Źródło:
Aktualne Problemy Biomechaniki; 2013, 7; 5-12
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary parametrów morfologiczno-czynnościowych stawu kolanowego z wykorzystaniem obrazowania rezonansem magnetycznym
Measurements of morphological and functional parameters of the knee joint using magnetic resonance imaging
Autorzy:
Ryniewicz, A.
Ryniewicz, A. M.
Sładek, J.
Knapik, R.
Powiązania:
https://bibliotekanauki.pl/articles/157400.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
staw kolanowy
parametry morfologiczno-czynnościowe
identyfikacja kształtu
rezonans magnetyczny
chrząstka stawowa
knee joint
morphological and functional parameters
shape identification
magnetic resonance
joint cartilage
Opis:
Celem była identyfikacja kształtu i położenia struktur stawu kolanowego obrazowanego rezonansem magnetycznym (MR) w stabilizowanej pozycji, w aspekcie rozkładu grubości chrząstki stawowej. Badano prawidłowe stawy kolanowe. Obrazowanie przeprowadzono przy wykorzystaniu aparatu MR typu otwartego ze stabilizatorem kąta zgięcia kolana w przekrojach strzałkowych, czołowych i horyzontalnych, w wybranych pozycjach kątowych. Pomiary chrząstki budującej powierzchnie stawowe stawu kolanowego wykazały znaczne zróżnicowanie jej grubości oraz pofalowania z charakterystycznym przesunięciem fali.
The aim of the study was to use the MRI to identify the shape and position of the structures of knee joints in a stabilized position, in terms of the analysis of joint cartilage thickness on femoral condyles, tibia condyles and the patella. There were studied normal knee joints. Imaging was performed with use of an open-type gradient coil MR apparatus with a knee bending angle stabilizer. The research strategy consisted of imaging: sagittal sections in a fixed position of the femoral bone relative to tibia, in selected sagittal sections for stabilized position of the femur relative to tibia for angles ranged from -10 degrees to 50 degrees, at 5 degree intervals, in the frontal sections with physiological extension, in the horizontal sections with physiological extension. Based on the MR imaging, there was measured the distribution of the thickness of joint cartilage that covered the femoral condyles, condyles of tibia and patella. The measurements of the cartilage building the surfaces of the knee joint showed significant variation in its thickness and folds with a characteristic wavelength shift in the tested sections. Variable thickness and uneven structures can substantially affect the conditions of joint lubrication and transfer of the locomotive load. Introduction of the stabilized position of the femur relative to tibia to the MR imaging allows useful identification of particular cartilage layers that work together.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 3, 3; 200-203
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena poziomu emisji wolnozmiennego pola magnetycznego
Assessment of the low-frequency magnetic magnetic-field emissions
Autorzy:
Pałczyńska, B.
Powiązania:
https://bibliotekanauki.pl/articles/266742.pdf
Data publikacji:
2014
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
małoczęstotliwościowe pole magnetyczne
adaptacyjna analiza czasowo-częstotliwościowa
algorytm pogoni za dopasowaniem
wskaźnik ekspozycji na pole magnetyczne
low-frequency magnetic field emission
adaptive joint time-frequency analysis
matching pursuit algorithm
Opis:
W artykule przedstawiono sposób oceny poziomu ekspozycji na wolnozmienne pola magnetyczne w odniesieniu do dopuszczalnych wartości, zawartych w zaleceniach międzynarodowych International Commission on Non-Jonizing Radiation Protection (ICNIRP). Estymację wskaźnika ekspozycji przeprowadzono na podstawie adaptacyjnej analizy czasowo– częstotliwościowej, zarejestrowanych przebiegów czasowych indukcji pola magnetycznego. Analizę adaptacyjną, opartą na algorytmie pogoni za dopasowaniem (ang. matching pursuit MP) zaimplementowano w graficznym zintegrowanym środowisku programowania LabVIEW. Przedstawiono wyniki analiz sygnału pomiarowego, reprezentującego poziom indukcji wolnozmiennego pola magnetycznego, zarejestrowanego w otoczeniu okrętowych odbiorników dużej mocy.
The occurrence of low-frequency, distorting magnetic fields in ship’s environment, directly affects the reliability of the electrical and electronic equipment and systems, and this way, the safety of navigation. These effects are also significant for the health of people staying near to the sources of magnetic field. Due to the above-mentioned reasons, emission limits have been defined by international committees both for the functional aspects and for limiting human exposure to magnetic emissions. For exposure to low-frequency magnetic fields, the magnetic flux density B is the parameter used by International Commission on Non-Ionizing Radiation Protection (the ICNIRP) for the definition of the reference levels. For the special case of simultaneous exposure to multiple frequency fields, a summation formula defined in ICNIRP guidelines was applied. In the paper, the way of the estimation of the exposure level to a low-frequency magnetic field in reference to admissible levels, proposed by ICNIRP. The instantaneous values of the safety factor were estimated with the adaptive joint timefrequency analysis of the digitized magnetic-flux density waveforms, acquired by measurement. The adaptive transform, based on the matching pursuit algorithm, was implemented in the LabVIEW software. The selected results of the analysis of the recorded signals of the safety factor of magnetic flux density in the surroundings of the ship’s motor drive with the power frequency converters are presented.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2014, 38; 49-52
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostics of welded joints using passive and active magnetic methods
Diagnostyka połączeń spawanych z wykorzystaniem pasywnych i aktywnych metod magnetycznych
Autorzy:
Dybała, J.
Nadulicz, K. M.
Powiązania:
https://bibliotekanauki.pl/articles/328364.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
magnetic diagnostics
passive methods
active methods
welded joint
diagnostyka magnetyczna
metody pasywne
metody aktywne
połączenie spawane
Opis:
As the quality of welded joints transfers to the load carrying capacity of structures, welded joints naturally become the object of diagnostic tests. Welded joints are mainly tested in order to find out the places with structural or mechanical non-homogeneities. It is caused by the fact that the existence of welding imperfections significantly decreases mechanical properties of the welded joint and especially its fatigue strength. The paper presents some results of diagnostic tests for welded joints of steel components carried out with the use of passive and active magnetic methods. Faults of the welded joint occurring within a tested object cause the phenomenon of magnetic anomalies existing over a tested surface and this phenomenon has been used to detect welding imperfections. A specially designed measurement matrix consisting of 768 oneaxial miniature magnetic field sensors has been used to record the magnetic flux leakage. The paper includes a comparison of the effectiveness of diagnosing using the passive and active magnetic method. Moreover, it was shown that the magnetic diagnostics provides rapid inspection of quality of welded joints with no need for special preparation of joints for testing which is relevant for its practical applications and results in low costs of such tests.
Ponieważ jakość złączy spawanych przekłada się na możliwości przenoszenia obciążeń przez konstrukcje, poáączenia spawane stają się w naturalny sposób obiektem badań diagnostycznych. Głównym celem badań połączeń spawanych jest wykrywanie miejsc, w których występuje niejednorodność strukturalna lub mechaniczna złącza. Taki cel badań wynika z faktu, że występowanie wad spawalniczych w decydującym stopniu pogarsza właściwości mechaniczne poáączenia spawanego, a w szczególności jego wytrzymałość zmęczeniową. W niniejszej pracy przedstawiono wyniki badań diagnostycznych połączeń spawanych stalowych elementów z wykorzystaniem pasywnych i aktywnych metod magnetycznych. Do wykrywania defektów połączenia spawanego wykorzystano zjawisko powstawania anomalii magnetycznych nad badaną powierzchnią wywołanych występowaniem wad spawalniczych w diagnozowanym elemencie. Zaburzenia strumienia magnetycznego były rejestrowane za pomocą specjalnie skonstruowanej matrycy pomiarowej składającej się z 768 jednoosiowych miniaturowych czujników pola magnetycznego. W pracy dokonano porównania skuteczności diagnozowania pasywną i aktywną metodą magnetyczną. Wykazano również, że diagnostyka magnetyczna umożliwia wykonanie szybkiej kontroli jakości połączeń spawanych bez konieczności specjalnego przygotowania połączeń do badań diagnostycznych, co ma duże znaczenie użytkowe i przekłada się bezpośrednio na niski koszt takich badań.
Źródło:
Diagnostyka; 2017, 18, 4; 51-59
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magneto-therapy of human joint cartilage
Autorzy:
Wierzcholski, K.
Miszczak, A.
Powiązania:
https://bibliotekanauki.pl/articles/306552.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
magnetoterapia
pole magnetyczne
efekty magnetoterapii
magnetic induction variable field
magnetotherapy
magneto electronic devices
positive effects of magnetotherapy
negative effects of magnetotherapy
human joint cartilage diseases
Opis:
Purpose: The topic of the present paper concerns the human joint cartilage therapy performed by the magnetic induction field. There is proved the thesis that the applied magnetic field for concrete cartilage illness should depend on the proper relative and concrete values of applied magnetic induction, intensity as well the time of treatment duration. Additionally, very important are frequencies and amplitudes of magnetic field as well as magnetic permeability of the synovial fluid. Material and methods: The research methods used in this paper include: magnetic induction field produced by a new Polish and German magneto electronic devices for the therapy of human joint cartilage diseases, stationary and movable magnetic applicators, magnetic bandage, ferrofluid injections, author’s experience gained in Germany research institutes and practical results after measurements and information from patients. Results: The results of this paper concern concrete parameters of time dependent electro-magnetic field administration during the joint cartilage therapy duration and additionally concern the corollaries which are implied from reading values gained on the magnetic induction devices. Conclusions: The main conclusions obtained in this paper are as follows: Time dependent magnetic induction field increases the dynamic viscosity of movable synovial fluid and decreases symptoms of cartilage illness for concrete intensity of magnetic field and concrete field line architecture. The ferrofluid therapy and phospholipids bilayer simultaneously with the administrated external electromagnetic field, increases the dynamic viscosity of movable synovial fluid.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 1; 115-124
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pulsed electro-magnetic joint lubrication therapy aided with the run-walk
Pulsująca elektromagnetyczna terapia smarowania stawów łączona biego-chodem
Autorzy:
Wierzcholski, K.
Powiązania:
https://bibliotekanauki.pl/articles/189390.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
new human joint diseases therapy
pulsed electro-magnetic fields
electro-magneto-hydrodynamic effects
run-walk implementation
new measurement devices
segmental body analyzation
betterments after treatment
nowa terapia chorób stawowych
pulsujące pole elektromagnetyczne
efekty elektromagneto-hydrodynamiczne
bieganie jako implementacja elektromagnetosmarowania
efekty składu masy ciała
korzystne efekty
Opis:
The topic of the presented paper concerns a new idea of therapy of human joint diseases, using pulsed electromagnetic lubrication treatment implemented by the run and walk training. Here, the thesis is proved that the pulse-electro-magnetic lubrication connected with the run-walk training increases energy burn, metabolism and it finally leads to the betterment of the performed therapy. The research performed in this paper is realized using the following devices: 1st apparatus generates Pulsed Electro-Magnetic Field (PEMF),2nd device produces Magnet-Tronic Field (MF-8), 3rd apparatus creates Multi Tronic activities (MT-3), 4th device delivers and resolves the Segmental Body Composition Analysis (SBCA), 5th is the electronic pedometer. Moreover in presented research are applied the author's experience gained in German research institutes and practical results of measurements and information from students, patients. The betterments of results obtained during the pulsed electro- magneto-therapy of the typical human cartilage diseases applying proper field shapes, frequencies, inductions and time durations, indicate the necessity of simultaneous training efforts in the form of run and walk to satisfy the best effects after performed treatments.
Tematem niniejszej pracy jest nowa idea terapii chorób stawowych człowieka polegająca na smarowaniu pulsującym polem elektromagnetycznym w połączeniu z treningiem biegu i chodu. Wykazuje się tezę o udoskonaleniu terapii zwiększającej przemianę materii wraz z energią spalania cellulitu poprzez pulsujące elektromagnetyczne smarowanie połączone z treningiem biegu i chodu. W badaniach eksperymentalnych wykorzystuje się następujące przyrządy i materiały: PEMF Magcell-Arthro przyrząd elektroniczny do zabiegów chrząstki stawowej, Analizator Tanita MC 780U do pomiaru składu ciała, krokomierz Garmin ltd 2015, doświadczenie autora zdobyte w niemieckich instytutach badawczych, a także wywiady lekarskie od pacjentów i studentów. Doskonalenie rezultatów uzyskanych podczas pulsującej elektromagnetycznej terapii typowych schorzeń chrząstki stawowej człowieka dla właściwych kształtów, częstotliwości i indukcji pola oraz czasu zabiegu wskazuje na konieczność jednoczesnego wysiłku treningowego w formie biegania lub chodu umożliwiającego uzyskanie optymalnych rezultatów zabiegu.
Źródło:
Tribologia; 2017, 275, 5; 109-115
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka patologii uszkodzeń stawu kolanowego w badaniu rezonansu magnetycznego przy wykorzystaniu różnych sekwencji
Diagnosis of knee joint damage pathology in magnetic resonance imaging using different sequences
Autorzy:
Kasztelan, M.
Wierzchosławska, E.
Powiązania:
https://bibliotekanauki.pl/articles/112343.pdf
Data publikacji:
2018
Wydawca:
Indygo Zahir Media
Tematy:
staw kolanowy
patologia stawu kolanowego
diagnostyka
uraz
rezonans magnetyczny
sekwencje
knee joint
pathologies of the knee joint
diagnostics
injury
magnetic resonance imaging
sequences
Opis:
Wstęp: Staw kolanowy to największy staw w ludzkim ciele poddany różnym obciążeniom powiązanym z uprawianiem sportu i wykonywaniem zawodu. W obrębie tego stawu często dochodzi do urazów, które nie zostają w odpowiednio szybkim czasie zdiagnozowane. Metodą, z wyboru, mającą zastosowanie w obrazowaniu patologii stawu kolanowego jest badanie rezonansu magnetycznego (MRI). Celem pracy jest ocena skuteczności, znaczenia i przydatności sekwencji MR wykorzystywanych w ocenie patologii stawu kolanowego. Materiał i metody: Wyniki zebrano i opracowano na podstawie uzyskanych obrazów rezonansu magnetycznego w grupie pacjentów z urazem stawu kolanowego. Badano grupę liczącą 60 osób z podziałem na płeć, wiek, patologie i wskazanie kliniczne. Badania wykonano aparatem rezonansu magnetycznego Magnetom Essenza 1,5 T (Siemens, Niemcy), używając sekwencji koniecznych do oceny stawu kolanowego: T1-, T2-, PD-zależnych oraz sekwencji PD-zależnej połączonej z techniką saturacji tłuszczu (FAT SAT). Wyniki: Wszystkie sekwencje były jednakowo skuteczne w ocenie złamania rzepki. Wszystkie za wyjątkiem sekwencji T1-zależnej były jednakowo skuteczne w wykrywaniu torbieli Bakera i patologicznego płynu, a za wyjątkiem sekwencji T2-zależnej w wykrywaniu zwapnień. W ocenie patologii w zakresie więzadeł, łąkotki, chrząstki stawowej oraz występowania obrzęku tkanek miękkich i stanów zapalnych najskuteczniejsze okazały się sekwencja PD- i PD-zależna z FAT SAT. Wnioski: W ocenie patologii w zakresie stawu kolanowego za pomocą MR najskuteczniejsze okazały się sekwencje PD-zależna bez i z saturacją tłuszczu.
Introduction: The knee joint is the largest joint in the human body subjected to various strains associated with practicing sports and exercising the profession. Injuries often occur within this knee joint, which are not diagnosed at the appropriate time. The method of choice applicable in the imaging of knee joint pathology is a magnetic resonance imaging (MRI). The aim of the work is to show the effectiveness of meaning and usefulness of the sequences, used in the assessment of pathologies of the knee joint. Material and methods: The results were collected and elaborated on the basis of obtained magnetic resonance images in the group of patients with a knee joint injury. A group of 60 subjects were examined with division into sex, pathologies, age and clinical indication. The examinations were carried out by a magnetic resonance apparatus Magnetom Essenza 1,5 T (Siemens Germany) using necessary sequences to estimate knee joint: T1-, T2- and dependent PD and dependent PD sequence combined with fat saturation technique (FAT SAT). Results: All sequences were equally effective in the assessment of patella fracture. All sequences with the exception of the dependent T1 sequence were equally effective in detecting the Baker cyst and the pathological fluid, with the exception of the dependent T2 sequence in the detection of calcifications. In the assessment of knee joint pathology in the scope of ligaments, meniscus, articular cartilage, and the occurrence of soft tissue edema and inflammation, the most effective sequence turned out to be PD- and PD with FAT SAT. Conclusions: In the assessment of knee joint pathology by means of (MRI) the most effective sequence turned out to be dependent PD without and with fat saturation (FAT SAT).
Źródło:
Inżynier i Fizyk Medyczny; 2018, 7, 5; 311-315
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Four-parameter electromagnetic method for determining the parameters of brewery effluents
Autorzy:
Sebko, V. V.
Pyrozhenko, Ye. V.
Zashchepkina, N. M.
Zdorenko, V. G.
Markina, O. M.
Powiązania:
https://bibliotekanauki.pl/articles/2201046.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
four-parameter electromagnetic method
brewery effluents
magnetic flux probe
MFP
conversion function
joint measurement
electrical conductivity
relative permittivity
density
temperature
metoda elektromagnetyczna
ścieki
strumień magnetyczny
funkcja konwersji
przewodność elektryczna
względna przenikalność elektryczna
gęstość
temperatura
Opis:
Purpose of the article is to study a four-parameter electromagnetic method for joint measurements of electrical resistivity k, relative permittivity εr, temperature t and density ρ of samples of acidic, alkaline and average effluents from a microbrewery based on a magnetic flux probe (MFP), which considers the influence of informative parameters of beer effluents on the components of the amplitude and phase signals of a multiparameter device. Design/methodology/approach The implementation of the four-parameter method is carried out on the basis of the dependences G1 = f (A1) and G2 = f (A2) at two frequencies of the electromagnetic field f0 and f1 for acid, alkaline and average effluent and allows you to jointly determine the four parameters of effluent samples with the same converter in the same control area. The proposed method makes it possible to improve the accuracy of identifying effluent samples since the obtained multiparameter information makes it possible to determine the nature and properties of effluent samples using only one transducer with certain physical characteristics. The research results lead to the expansion of the technical capabilities of electromagnetic measurement methods, as well as to an increase in the metrological characteristics of electromagnetic transducers and an increase in the accuracy of measuring the parameters of effluent samples compared to reference methods and measuring instruments. Thus, the implementation of this approach contributes to the prediction and prevention of the reasons for the deviation of beer effluent samples from the specified indicators of environmental safety. Findings The universal conversion functions MFP have been established, connecting the amplitude and phase components of the converter signals with the parameters k, εr, t and ρ of acidic, alkaline and average effluents. Based on the universal transformation functions G1 = f (A1) and G2 = f (A2), a four-parameter electromagnetic method for joint measurements of electrical resistivity k, relative permittivity εr, temperature t and density ρ of acidic, alkaline, and average effluents from breweries has been developed. When conducting research at two close frequencies of the electromagnetic field f0 = 20.3 MHz and f1 = 22 MHz, algorithms were obtained for measuring and calculating procedures for determining k, εr, t and ρ for samples of acidic, alkaline and average effluents from the brewing industry. Research limitations/implications Research perspectives consist in the creation of automated systems for multiparameter measuring control of the physicochemical characteristics of acidic and alkaline effluent from food and processing industries based on the immersed electromagnetic transducer. Based on the data obtained using informative methods to measure the parameters of effluent samples, an integrated method for treating beer effluents of various compositions will be proposed. At the same time, the scheme of the integrated treatment method should include a filter that provides the introduction of a magnetic fluid and a separation device that allows us to remove a fraction, including pollution in itself. Practical implications Is that the proposed four-parameter electromagnetic method makes it possible to determine to what composition the controlled samples of wastewater should be attributed (acidic or alkaline). It, in turn, makes it possible to choose a rational method for treating beer effluents and to prevent the reasons for the deviation of effluent samples from the environmental safety indicators set by the standards. Originality/value of the article is the research related to the expansion of the functional and technical capabilities of the electromagnetic two-frequency transducer MFP through the implementation of a four-parameter electromagnetic method of joint measurements of electrical resistivity k, relative permittivity εr, temperature t and density ρ of acidic, alkaline and average effluents from breweries. The universal transformation functions G1 = f (A1) and G2 = f (A2) found in the work at two close magnetic field frequencies, f0 = 20.3 MHz and f1 = 22 MHz, make it possible to control four physicochemical parameters of acidic, alkaline and average wastewater at the same time by the same MFP. An algorithm has been developed for determining the signal components of a two-frequency thermal MFP, the ranges of which correspond to the ranges of changes in electrical resistivity k, relative permittivity εr, temperature t and density ρ of acidic, alkaline, and average brewery effluents. The basic relations that describe the two-frequency four-parameter electromagnetic method of joint measurements of the physicochemical parameters of acidic, alkaline and averaged beer effluents have been obtained.
Źródło:
Journal of Achievements in Materials and Manufacturing Engineering; 2022, 113, 2; 49--64
1734-8412
Pojawia się w:
Journal of Achievements in Materials and Manufacturing Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies