Safety of nuclear power
Autorzy:
Strupczewski, A.
Powiązania:
https://bibliotekanauki.pl/articles/147940.pdf
Data publikacji:
2005
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
low radiation doses
LNT
hormesis
epidemiological studies
biological defense mechanism
Chernobyl effects
Opis:
The main questions related to nuclear power development concern effects of small radiation doses typical for the operation of nuclear power plants (NPPs) and hazards of NPP accidents. The last decade has brought many results of large scale epidemiological studies indicating that there are no detrimental effects of low radiation doses. On the contrary, many results indicate that among the people receiving increased radiation doses the frequency of cancer mortality is reduced. The review shows that such results are obtained in the studies of people living in high background radiation areas, of workers exposed to ionizing radiation and of patients exposed to radiation for diagnostic purposes. The latest studies in molecular biology suggest an explanation for possible beneficial effects of low radiation doses. This is reflected in the statements of several scientific bodies and international organizations, although the official regulations remain unchanged. The other important issue is the safety of NPPs in case of accidents. Reasons for the Chernobyl accident are shown not to be applicable to the reactors planned for Poland and the effects of Chernobyl are shown to be much smaller than feared in original estimates after the accident. Polish NPPs will satisfy the requirements of EU utilities and will provide safety for the population even in case of hypothetical severe accidents. Nevertheless, discussion with antinuclear organizations must be expected, although the recent examples of changing attitudes of leading ecological authorities show that nuclear power is gaining recognition as a clean and environmentally friendly source of energy.
Źródło:
Nukleonika; 2005, 50,suppl.3; 59-66
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Low-level exposures to ionising radiation modulate the anti-tumour activity of murine NK cells
Autorzy:
Nowosielska, E.
Wrembel-Wargocka, J.
Cheda, A.
Lisiak, E.
Janiak, M.
Powiązania:
https://bibliotekanauki.pl/articles/147802.pdf
Data publikacji:
2005
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
low doses
X-rays
NK cells
cytotoxicity
anti-asialo GM1 antibody
FasL
Opis:
Experimental evidence from the recent years indicates that low-level irradiations with X- or gamma rays may inhibit development of both primary and secondary tumours and stimulate the activity of natural anti-tumour immune mechanisms. Natural killer (NK) cells play an important role in anti-tumour defence of the host. In the present investigation cytotoxic activity, production of interferon-ă, and expression of the Fas ligand (FasL) were estimated in the NK splenocytes collected from BALB/c mice whose whole body was pre-exposed to irradiation with 0.1, 0.2, or 1.0 Gy X-rays. The results indicate that cytotoxic activity of the irradiated NK cells was significantly stimulated compared to that of the NK effectors obtained from the sham-exposed mice. This effect was totally abrogated by injection of the anti-asialo GM1 antibody. In addition, compared to the control mice, NK cells obtained from the irradiated animals exhibited reduced surface expression of FasL. Collectively, the obtained results suggest that the inhibitory effect of the low-level irradiations with X-rays on the development of pulmonary tumour nodules may be directly associated with stimulation by such exposures of anti-neoplastic functions mediated by NK cells.
Źródło:
Nukleonika; 2005, 50,suppl.2; 21-24
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wpływu małych dawek – nieterapeutycznych – na czynność bioelektryczną mózgu u pacjentów napromienianych w rejonie głowy i szyi. Doniesienie wstępne
Evaluation of the effect of small non-therapeutic doses on brain bioelectrical activity of patients irradiated in the region of head and neck
Autorzy:
Łukowiak, M.
Jezierska, K.
Podraza, H.
Podraza, W.
Lewocki, M.
Powiązania:
https://bibliotekanauki.pl/articles/261431.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
radiobiologia
radioterapia
małe dawki promieniowania
elektroencefalografia
planowanie leczenia
radiobiology
radiotherapy
low radiation doses
electroencephalography
treatment planning
Opis:
W ostatnich latach radiobiolodzy we współpracy z fizykami medycznymi i radioterapeutami próbują oszacować toksyczność małych dawek promieniowania jonizującego na zdrowe tkanki znajdujące się w sąsiedztwie obszarów eksponowanych na wysokie dawki terapeutyczne. Poniższa praca jest próbą oszacowania wpływu małych dawek, w zakresie od 50 do 1000 cGy, na obszar mózgowia u pacjentów poddawanych radioterapii w obszarze głowy i szyi, na podstawie zapisu czynności bioelektrycznej mózgu zarejestrowanego przed i po leczeniu. W badaniu analizowane są dwa schematy napromieniania pacjentów techniką IMRT (ang. Intensity-Modulated Radiation Therapy), różniące się liczbą wiązek terapeutycznych oraz kątami ich wejścia.
In the last years, radiobiologists together with medical physicists and radiotherapeutists try to estimate the toxicity of low doses ionizing radiation on healthy tissue located near the regions exposed to high therapeutic doses. This work presents an attempt to examine the low doses ionizing radiation in range of 50 to 1000 cGy brain tissue in patients irradiated in head and neck region by exploiting the bioelectric brain signals registered before and after the treatment. Two modes of Intensity-Modulated Radiation Therapy (IMRT) irradiation, with various numbers of therapeutic beams and input angles, were analysed.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2015, 21, 1; 16-23
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurements of doses from photon beam irradiation and scattered neutrons in an anthropomorphic phantom model of prostate cancer: a comparison between 3DCRT, IMRT and tomotherapy
Autorzy:
Kowalik, A.
Jackowiak, W.
Malicki, J.
Skórska, M.
Adamczyk, M.
Konstanty, E.
Piotrowski, T.
Polaczek-Grelik, K.
Powiązania:
https://bibliotekanauki.pl/articles/146348.pdf
Data publikacji:
2017
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
3DCRT
IMRT
low doses
neutron doses
thermoluminescent detectors (TLD)
tomotherapy
Opis:
The rapid development of new radiotherapy technologies, such as intensity modulated radiotherapy (IMRT) or tomotherapy, has resulted in the capacity to deliver a more homogenous dose in the target. However, the higher doses associated with these techniques are a reason for concern because they may increase the dose outside the target. In the present study, we compared 3DCRT, IMRT and tomotherapy to assess the doses to organs at risk (OARs) resulting from photon beam irradiation and scattered neutrons. Material and methods. The doses to OARs outside the target were measured in an anthropomorphic Alderson phantom using thermoluminescence detectors (TLD 100) 6Li (7.5%) and 7Li (92.5%). The neutron fluence rate [cm–2·s–1] at chosen points inside the phantom was measured with gold foils (0.5 cm diameter, mean surface density of 0.108 g/cm3). Results. The doses [Gy] delivered to the OARs for 3DCRT, IMRT and tomotherapy respectively, were as follows: thyroid gland (0.62 ± 0.001 vs. 2.88 ± 0.004 vs. 0.58 ± 0.003); lung (0.99 ± 0.003 vs. 4.78 ± 0.006 vs. 0.67 ± 0.003); bladder (80.61 ± 0.054 vs. 53.75 ± 0.070 vs. 34.71 ± 0.059); and testes (4.38 ± 0.017 vs. 6.48 ± 0.013 vs. 4.39 ± 0.020). The neutron dose from 20 MV X-ray beam accounted for 0.5% of the therapeutic dose prescribed in the PTV. The further from the field edge the higher the contribution of this secondary radiation dose (from 8% to ~45%). Conclusion. For tomotherapy, all OARs outside the therapeutic field are well-spared. In contrast, IMRT achieved better sparing than 3DCRT only in the bladder. The photoneutron dose from the use of high-energy X-ray beam constituted a notable portion (0.5%) of the therapeutic dose prescribed to the PTV.
Źródło:
Nukleonika; 2017, 62, 1; 29-35
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The cancer risk among workers of the nuclear centre at Świerk, Poland
Autorzy:
Fornalski, K.W.
Dobrzyński, L.
Powiązania:
https://bibliotekanauki.pl/articles/148146.pdf
Data publikacji:
2013
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
nuclear workers
low doses
radiation influence
Świerk
Polska
Opis:
Dosimetric information concerning 4606 workers at the nuclear centre at Świerk (Poland) from 1956 to 2001 and medical records of 575 workers are reviewed. The average cumulative doses per person were 34 mSv (effective dose) and 18 mSv (equivalent dose to hands). The calculated odds ratio of cancers, OR = 0.90 (0.62–1.18; 68% CI), shows a statistically insignificant decrease of the cancer risk among the irradiated workers. No cancer cases were detected neither among 52 people exposed to the highest cumulative doses (from 35 to 653 mSv) nor among 43 workers who had been chronically irradiated for a long time (from 13 to 26 years).
Źródło:
Nukleonika; 2013, 58, 4; 537-542
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Occupational exposure to ionizing radiation and lens opacity in interventional cardiologists
Autorzy:
Domienik-Andrzejewska, Joanna
Kałużny, Paweł
Piernik, Gabriela
Jurewicz, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/2161953.pdf
Data publikacji:
2019-10-16
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
occupational exposure
ionizing radiation
cataract
low doses
cumulative eye lens doses
interventional cardiologists
Opis:
Objectives Interventional cardiologists (ICs) are occupationally exposed to low or moderate doses of ionizing radiation from repeated exposures. It is not clear whether these occupational conditions may affect their eye lens. Therefore, the risk of radiation-induced cataract in the cohort of Polish interventional cardiologists is analyzed in this paper. Material and Methods The study group consisted of 69 interventional cardiologists and 78 control individuals occupationally unexposed to ionizing radiation. The eye lens opacities were examined using a slit camera and evaluated with Lens Opacities Grading System III. Cumulative eye lens doses were estimated retrospectively using a questionnaire including data on occupational history. Results The average cumulative dose to the left and right eye lens of the ICs was 224 mSv and 85 mSv, respectively. Nuclear opalescence and nuclear color opacities in the most exposed left eye were found in 38% of the ICS for both types, and in 47% and 42% of the controls, respectively. Cortical opacities were found in 25% of the ICS and 29% of the controls. Posterior subcapsular opacities were rare: about 7% in the ICs group and 6% in the control group. Overall, there was some, but statistically insignificant, increase in the risk for opacity in the ICs group, relative to the control group, after adjusting for the subjects’ age, gender, smoking status and medical exposure (adjusted OR = 1.47, 95% CI: 0.62–3.59 for the pooled “any-eye any-type” opacity). There was also no evidence for an increased opacity risk with an increase in the dose. Conclusions The study found no statistically significant evidence against the hypothesis that the risk of cataract in the group of the ICs occupationally exposed to low doses of ionizing radiation is the same as in the control group. Nevertheless, the adverse effect of ionizing radiation still cannot be excluded due to a relatively small study sample size. Int J Occup Med Environ Health. 2019;32(5):663–75
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2019, 32, 5; 663-675
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
O konieczności zmiany paradygmatu ochrony radiologicznej – Komentarz SARI – Stowarzyszenia Uczonych dla Rzetelnej Informacji o Promieniowaniu
On the Need to Replace the Present Paradigm of Radiation Protection - Comments by SARI (Scientists for Accurate Radiation Information)
Autorzy:
Dobrzyński, L.
Janiak, M. K.
Strupczewski, A.
Waligórski, M.
Powiązania:
https://bibliotekanauki.pl/articles/214587.pdf
Data publikacji:
2017
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
system ochrony radiologicznej
hipoteza LNT
hormeza radiacyjna
niskie dawki i moce dawki (LDDR)
reakcje immunologiczne
zdrowie publiczne
zdarzenia radiacyjne
radiofobia
Radiation Protection System
LNT hypothesis
radiation hormesis
low doses and dose rates (LDDR)
immune reactions
public health
nuclear accidents
radiophobia
Opis:
W jednym ze swoich pierwszych aktów wykonawczych, Prezydent Donald Trump zalecił „uwolnienie obywateli Stanów Zjednoczonych od nadmiernie uciążliwych norm i regulacji”. W odpowiedzi, Amerykańska Agencja Ochrony Środowiska (EPA) zaapelowała o propozycje, które uczyniłyby regulacje dotyczące ochrony radiologicznej „mniej uciążliwymi”. Stowarzyszenie Uczonych dla Rzetelnej Informacji o Promieniowaniu (SARI) przesłało do EPA swój Komentarz w tej sprawie, w którym proponuje, aby odrzucić hipotezę liniową bez progu dawki (Linear No-Threshold, LNT) jako podstawę przepisów ochrony radiologicznej i zastąpić ją przez hormezę - dobroczynne działanie niskich/o niskiej mocy dawek promieniowania jonizującego, uruchomiających naturalne mechanizmy obronne w organizmie człowieka, głównie poprzez pobudzenie takich reakcji jak usuwanie rodników tlenowych, naprawę DNA i funkcje immunologiczne. Oparcie przepisów ochrony radiologicznej na hormezie radiacyjnej doprowadzi do poprawy zdrowia ogółu ludności i znacznego obniżenia kosztów społecznych ochrony przed promieniowaniem oraz ograniczy negatywne skutki ewentualnych awarii jądrowych. Tekst Komentarza SARI został przetłumaczony, aby umożliwić polskiemu czytelnikowi zapoznanie się z tym krótkim, ale wnikliwym przeglądem proponowanego systemu ochrony radiologicznej, opartego o zjawisko hormezy radiacyjnej, wraz z naukowym uzasadnieniem powodów, dla których należy odrzucić obecny paradygmat tego systemu - hipotezę LNT.
By one of his first Executive Orders, President Trump established the “policy of the United States to alleviate unnecessary regulatory burdens placed on the American people.” Acting on this order, the US Environmental Protection Agency (EPA) solicited comments on making radiation protection regulations “less burdensome.” In response, SARI (Scientists for Accurate Radiation Information) submitted to EPA a document proposing that the (Linear No-Threshold, LNT) hypothesis on which radiation protection regulations are presently based should be rejected and replaced by hormesis – the beneficial action of low doses and low dose rates (LDDR) of ionizing radiation, predominantly due to activation of natural defence mechanisms of the body such as scavenging of reactive oxygen species, up-regulation of DNA repair, and boosting of immune reactions. Basing radiation protection regulations on radiation hormesis will benefit the health of the public, significantly decrease the public costs of radiation protection and reduce the adverse impact of any future nuclear accidents. The text of the SARI document has been translated to provide the Polish reader with a brief but comprehensive review of the proposed hormesis-based system of radiation protection and with science-based arguments for rejecting its present LNT paradigm.
Źródło:
Postępy Techniki Jądrowej; 2017, 3; 2-11
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of ionizing radiation low doses on early stages of odontogenesis
Autorzy:
Cheshko, N. N.
Berlov, H. A.
Pohodenko-Chudakova, I. O.
Powiązania:
https://bibliotekanauki.pl/articles/285617.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
odontogenesis
ionizing radiation low doses
tooth germ
Źródło:
Engineering of Biomaterials; 2008, 11, no. 77-80; 7-8
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stimulatory effects of single low-level irradiations with X-rays on functions of murine peritoneal macrophages
Autorzy:
Cheda, A.
Wrembel-Wargocka, J.
Nowosielska, E.
Janiak, M.
Powiązania:
https://bibliotekanauki.pl/articles/147798.pdf
Data publikacji:
2005
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
low doses
X-rays
macrophages
nitric oxide
cytotoxicity
TNF-alfa
Opis:
A number of epidemiological and experimental data indicate that exposures to low doses of low-LET ionising radiation may trigger the activity of natural anti-tumour immune mechanisms and inhibit tumour growth. In the present study, we assessed the cytotoxic activity and production of nitric oxide, superoxide anions, and tumour necrosis factor-alfa in peritoneal macrophages collected from BALB/c mice exposed to single whole-body irradiations with 0.1, 0.2, or 1.0 Gy X-rays. The results indicate that all the tested parameters were significantly up-regulated in macrophages obtained from mice exposed to 0.1 or 0.2 Gy X-rays but not in those collected from the sham-irradiated and 1.0 Gy-exposed animals.
Źródło:
Nukleonika; 2005, 50,suppl.2; 13-16
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies