Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "logger" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
A Low-cost Automatic System for Long-term Observations of Soil Temperature
Autorzy:
Zaszewski, Daniel
Gruszczyński, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2174655.pdf
Data publikacji:
2023
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
data logger
Arduino boards
soil temperature
heat transport
DS18B20 digital thermometers
Opis:
The description of the physical parameters characterizing heat transport in the soil medium, especially on a regional scale, requires long-term and high frequency observations of temperature changes in soil profiles. This paper presents a project for a multi-channel, modular and universal data logger for temperature distribution data collecting in the soil profile, based on open electronic components, such as Arduino microcontroller systems and DS18B20 thermometers. The data logger tests were carried out in two profiles. The seven-month tests did not show any errors in the functioning of the measurement set. The presented device requires an average current of 320 µA, which allows for its stable operation on one battery set for about 300 days in temperate climate conditions. The DS18B20 thermometers allow for accurate and stable temperature measurement (the mean absolute error after laboratory calibration was 0.02°C). The cost of a single measurement-registration device was approximately 76 EUR, representing a competitive price in comparison with commercial data loggers. This allows, with relatively low expenditure, the creation of extensive observation networks for the analysis of the heat flow process in high temporal and spatial resolution.
Źródło:
Geomatics and Environmental Engineering; 2023, 17, 1; 75--101
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Implementacja stosu komunikacji w zasilanych bateryjnie urządzeniach NB-IoT
Implementation of Communication Stack for Battery-Powered NB-IoT Devices
Autorzy:
Szydłowski, Piotr
Zaręba, Karol
Powiązania:
https://bibliotekanauki.pl/articles/27312456.pdf
Data publikacji:
2023
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
NB-IoT
Internet rzeczy
CoAP
Protobuf
stos komunikacji
rejestrator
zasilanie bateryjne
Narrowband IoT
IoT
communication stack
logger
battery-powered
Opis:
W artykule zaprezentowano sposób implementacji wydajnego stosu komunikacji dla bezprzewodowych, zasilanych bateryjnie rejestratorów NB-IoT. Na podstawie doświadczeń zgromadzonych przy projektowaniu i rozwoju oprogramowania rejestratorów, wykonano analizy mające na celu wybór odpowiednich protokołów komunikacji, formatu serializacji danych, konfiguracji modułu NB-IoT oraz dodatkowe algorytmy opracowane w celu optymalizacji liczby transmisji i ilości przesyłanych danych. Przedstawiono również uzyskane wyniki wraz z analizą wpływu poszczególnych parametrów konfiguracji na czas życia baterii urządzenia i zużycie danych.
In this article we present how to implement an efficient communication stack for wireless, battery-powered NB-IoT loggers. Based on the experience gained by designing and developing loggers’ software, we present our analyses performed in order to select the appropriate communication protocols, data serialisation format, configuration of the NB-IoT module and proprietary algorithms developed to optimise the number of transmissions and the amount of data sent. We also present the obtained results together with an analysis of the impact of individual configuration parameters on the devices’ battery life and data usage.
Źródło:
Pomiary Automatyka Robotyka; 2023, 27, 3; 73--83
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Winding machine additional overload state indication as supporting solution for mine shaft hoist operators
Autorzy:
Siostrzonek, Tomasz
Trójca, Piotr
Wójcik, Jakub
Powiązania:
https://bibliotekanauki.pl/articles/111362.pdf
Data publikacji:
2019
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
mining shaft hoist
logger
winding machine control system
Opis:
Dangerous events that take place in the mining plant always give us a chance to rethink whether the design of a faulty device could have been improved enough to prevent such a situation. The same scenario takes place with mining shaft hoist. Withouta doubt, a starting point for discussions about additional mining shaft hoist security measures is the last dangerous situation that took place in a Silesian mine in 2017. This article is an analysis of the probable causes and conclusions that can be drawn from that incident.
Źródło:
Mining – Informatics, Automation and Electrical Engineering; 2019, 57, 1; 40-43
2450-7326
2449-6421
Pojawia się w:
Mining – Informatics, Automation and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research of the stopping distance for different road conditions
Autorzy:
Lyubenov, D.
Powiązania:
https://bibliotekanauki.pl/articles/374313.pdf
Data publikacji:
2011
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
droga hamowania
zwalnianie
stopping distance
deceleration
VBOX 3I GPS Data Logger
Opis:
In this paper a modern method for determination of stopping distance is represented. Application of the non-contact VBOX 3i 100Hz GPS Data Logger speed and distance measurement system is represented. A description of the total stopping distance of vehicle main components - driver reaction time, vehicle reaction time and vehicle braking capability has been made. Research of the total stopping distance of a vehicle for different road conditions has been made. The results for the stopping distance can be very useful in the expert practice.
Źródło:
Transport Problems; 2011, 6, 4; 119-126
1896-0596
2300-861X
Pojawia się w:
Transport Problems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie algorytmu genetycznego w celu wyznaczenia współczynników wzmocnienia wzmacniacza wejściowego rejestratora sygnałów
Use of a genetic algorithm to determine the gain of the input amplifier of the signal logger
Autorzy:
Kciuk, M.
Bartel, S.
Powiązania:
https://bibliotekanauki.pl/articles/268137.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
algorytm genetyczny
wzmocnienie
wzmacniacz wejściowy
rejestrator sygnałów
genetic algorithm
gain
input amplifier
signal logger
Opis:
W artykule przedstawiono projekt wzmacniacza nieodwracającego o zmiennym współczynniku wzmocnienia dla modułu pięciozakresowego miernika napięcia. Zadaniem wzmacniacza jest dopasowanie zakresu wejściowego urządzenia do wejścia przetwornika analogowo-cyfrowego. Przełączenie zakresu (wzmocnienia) odbywa się poprzez wybór odpowiedniej pary rezystorów odpowiedzialnych za wzmocnienie i podzielenie sygnału. Zestaw rezystorów przełączanych został dobrany za pomocą algorytmu genetycznego zaimplementowanego jako aplikacja napisana w środowisku LabVIEW. Program poszukuje rozwiązania w zadanej puli rezystorów zwanej populacją, poszukując wartości spełniające wszystkie zadane wzmocnienia sygnału.
Goal of the paper is to find proper resisnace values for input amplifier of voltage measurement module – see fig. 2. The voltage measurement module is a part of a bigger device which is a signal logger presented in fig. 1. The structure of the amplifier is presented in fig. 3. A pairs of resistors set the amplifier gains, the gain factor is given by equation (1). One resistor from RA group (which contains R1-R3) and one resistor from RB group (which contains R4-R6) set the gain factor. The variable gain convertes signal from choosen input of the module into ADC converter input. The module need five measurement ranges which have to be converted into ADC input, so five gain factors are needed. The genetic algorithm was employed to find the resistance values. Group of six resistors called genes buid chromosome – fig. 4. The matching function compares nine gains given by pairs of resistors with five desirable gains, each mached gain increases matching factor, expected factor is equal to five. The maching function is presented in fig. 6. The software was implemented in LabVIEW environment. The code is presented in fig. 7, as well as GUI is presented in fig. 8. The software finds the solution in given range of resistor values. In result it try to find all five signal gains. Two series of resistances were taken into account, the first one is E96 (1%) serie with 318 elements, the second one was series available in local electronic shop with 72 elements. The solutions were found in both cases. The results are presented in fig. 9.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 49; 53-56
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena współczynnika efektywności barometrycznej za pomocą rejestratora pojemnościowego firmy DATAFLOW
Assessment of barometric efficiency of piezometer with help of DATAFLOW logger
Autorzy:
Kachnic, M.
Powiązania:
https://bibliotekanauki.pl/articles/2063155.pdf
Data publikacji:
2009
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
współczynnik efektywności barometrycznej
rejestrator
Koniczynka
barometric efficiency
logger
Opis:
Piezometr Stacji Bazowej Zintegrowanego Monitoringu Środowiska w Koniczynce charakteryzuje się współczynnikiem efektywności barometrycznej o wartości 0,11 - 0,3. Zmiana ciśnienia atmosferycznego 0 10 hPa przenosi się na zmianę położenia zwierciadła wody o ok. 13 mm. Zamontowany w piezometrze rejestrator pojemnościowy firmy DATAFLOW SYSTEMS umożliwia znacznie dokładniejsze badanie zmian położenia zwierciadła wody w zależności od czynników zewnętrznych.
In wells and piezometers penetrating unconfined aquifers, the water levels are continuously changing according to the atmospheric pressure changes. By comparing the atmospheric changes, expressed in terms of a column of water, with the actual changes in the water levels observed during the pre-test period, it is possible to calculate the barometric efficiency of the aquifer. In this paper there was calculated barometric efficiency of piezometer in a Base Station of the Integrated Monitoring of the Natural Environment in Koniczynka near Toruń in Poland with help of data logger DATAFLOW SYSTEMS.
Źródło:
Biuletyn Państwowego Instytutu Geologicznego; 2009, 436, z. 9/1; 195-198
0867-6143
Pojawia się w:
Biuletyn Państwowego Instytutu Geologicznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cyfrowy rejestrator danych jako element sieci pomiarowej do monitoringu dynamiki konstrukcji maszyn górnictwa odkrywkowego
Digital data logger as an element of measurement net for monitoring of dynamics of open-cast mining machines constructions
Autorzy:
Huss, W.
Powiązania:
https://bibliotekanauki.pl/articles/409049.pdf
Data publikacji:
2011
Wydawca:
Politechnika Śląska
Tematy:
górnictwo odkrywkowe
maszyny górnicze
cyfrowy rejestrator danych
monitorowanie maszyn
opencast mining
mining machines
digital data logger
machine monitoring
Opis:
Artykuł prezentuje budowę i funkcje rejestratora danych zaprojektowanego i skonstruowanego w Zakładzie Inżynierii Niezawodności i Diagnostyki Politechniki Wrocławskiej. Nosi on nazwę cyfrowy rejestrator danych i działa w układzie sieciowym wraz innymi rejestratorami tego typu oraz (opcjonalnie) z komputerem. Taki sposób akwizycji danych pomiarowych został zaprojektowany z myślą o monitorowaniu kilku rodzajów wielkości informujących o stanie eksploatacyjnym maszyn podstawowych górnictwa odkrywkowego, w szczególności koparek kołowych. Takie warunki pracy charakteryzują się dużym rozrzuceniem przestrzennym punktów pomiarowych, a najczęściej mierzone sygnały pochodzą z przetworników tensometrycznych. Mimo to system ten nadaje się również do współpracy z innymi czujnikami i w odmiennych warunkach pracy.
This article presents a structure and functions of a data logger that was developed in Reliability Engineering and Diagnostics Division in Wroclaw University of Technology. The device was named Digital Data Logger and cooperates with similar loggers (or PC computer) in one diagnostic net. This particular way of acquisition was designed to gather several kinds of quantities and provide information about operational state of open-cast mining machines. This specific circumstances are characterized by widely spread measurement points, which mostly are strain gauges. Discussed measurement system can also be applied to working with other kinds of sensors and in different working conditions.
Źródło:
Wybrane Problemy Inżynierskie; 2011, 2; 133-138
2083-1021
Pojawia się w:
Wybrane Problemy Inżynierskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie czujników bezprzewodowego pomiaru temperatury w optymalizacji wypieku pieczywa żytniego
Utilizaion of the logger in the optimization of the rye bread baking
Autorzy:
Ceglińska, A.
Cacak-Pietrzak, G.
Haber, T.
Deja, M.
Powiązania:
https://bibliotekanauki.pl/articles/228485.pdf
Data publikacji:
2006
Wydawca:
Wyższa Szkoła Menedżerska w Warszawie
Tematy:
wypiek pieczywa żytniego
optymalna temperatura
czujnik bezprzewodowego pomiaru temperatury
logger
Opis:
W przedstawionej w artykule pracy podjęto próbę określenia optymalnej temperatury wypieku pieczywa żytniego z mąki jasnej oraz ciemnej - wykorzystując czujnik bezprzewodowego pomiaru temperatury, tzw. logger. Najlepszą jakość pieczywa żytniego z mąki jasnej i ciemnej otrzymano podczas wypieku w temperaturach komory wypiekowej wynoszących odpowiednio 156-187 i 145-183°C. Rejestracja temperatury za pomocą loggerów pozwala ocenić prawidłowość przebiegu procesu technologicznego oraz ustalić optymalne temperatury np. górowania ciasta, wypieku, schładzania pieczywa, co jest szczególnie ważne przy opracowywaniu technologii nowych asortymentów pieczywa.
The utilization of the logger for determination of the optimum-temperature of the rye bread from the white and darkflours was the aim of the present study. The best quality of the rye bread from the white and darkflours one received during the baking in temperatures amounting properly 156-187 and 145-183° C. The registration of the temperature by the logger permits to evaluate the regularity of the technological process and to fix optimum-temperatures, eg. of the baking. This is especially important in composition of the new bread technology.
Źródło:
Postępy Techniki Przetwórstwa Spożywczego; 2006, T. 16, nr 2, 2; 17-19
0867-793X
2719-3691
Pojawia się w:
Postępy Techniki Przetwórstwa Spożywczego
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies