Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "linear calibration" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
On some calibration estimators of subpopulation total for longitudinal data
Autorzy:
Żądło, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/657601.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Łódzki. Wydawnictwo Uniwersytetu Łódzkiego
Tematy:
longitudinal data
general linear mixed model
empirical best linear unbiased predictor
calibration estimators
Opis:
The problem of modeling longitudinal profiles is considered assuming that the population and elements affiliation to subpopulation may change in time. The considerations are based on a model with auxiliary variables for longitudinal data with subject specific (in this case - element and subpopulation specific) random components (compare Verbeke, Molenberghs, 2000; Hedeker, Gibbons, 2006) which is a special case of the General Linear Mixed Model. In the paper calibration estimators of subpopulation total for data from one period are presented and some modifications for the case of longitudinal data are proposed. Design-based mean squared errors and its estimators are also presented. In the simulation study accuracy of the estimators is compared with Horvitz-Thomson estimator and the best empirical linear unbiased predictor derived for the considered model.
Źródło:
Acta Universitatis Lodziensis. Folia Oeconomica; 2011, 252
0208-6018
2353-7663
Pojawia się w:
Acta Universitatis Lodziensis. Folia Oeconomica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stanowisko do wyznaczania położenia środka masy ciała człowieka
The measuring device for determining the location of the center of human body mass
Autorzy:
Masłowski, W.
Opara, T.
Burek, M.
Powiązania:
https://bibliotekanauki.pl/articles/945995.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
środek masy ciała człowieka
kalibracja liniowa
system antropokinetyczny
posturografia
center of mass
linear calibration
posturography
Opis:
W artykule opisano stanowisko do wyznaczania położenia środka masy ciała człowieka. Konstrukcję stanowiska oparto na dźwigni jednostronnej. Metodę tę jako pierwszy zastosował i opisał Emil du Bois-Reymond. Stanowisko jest elementem wyposażenia laboratorium posturografii Wyższej Szkoły Oficerskiej Sił Powietrznych w Dęblinie, w której są prowadzone badania zdolności do utrzymania równowagi statycznej kandydatów na pilotów wojskowych. Informację ilościową określającą funkcjonowanie układu utrzymania równowagi można uzyskać przez badania posturograficzne. Obejmują one wyznaczenie położenia środka masy ciała badanej osoby, co jest niezbędne do oceny podstawowych parametrów opisujących równowagę człowieka w postawie stojącej. Uzyskane wyniki pozwoliły na wyznaczenie parametrów rozkładu statystycznego względnej wysokości środka masy ciała dla licznej grupy młodych mężczyzn i kilku kobiet. Grupa ta ma charakter specyficzny, gdyż są to osoby w podobnym wieku, których potencjalna przydatność do zawodu pilota została już wcześniej potwierdzona przez szczegółowe badanie stanu zdrowia, sprawności fizycznej i psychotechnicznej.
The article describes the measuring device for determining the location of the center of human body mass, the construction of which is based on the properties of a one-sided lever. This device is a part of the posturograph laboratory of the Air Force Academy in Dęblin, where research is conducted on the ability to maintain static balance of candidates for military pilots. Quantitative information describing the functioning of the balance maintenance system can be obtained through posturographic research. It includes determination of the location of the center of body mass of the examined person. The measuring device was subjectedto the linear calibration process. The obtained results allowed to determine the parameters of the statistical distribution of the relative height of the body mass center for a large group of young men and a few women. This group is specific in nature, because they are people of similar age, whose potential fitness for the military pilot profession has already been confirmed by a detailed examination of the state of health, physical and psychotechnical skills.
Źródło:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika; 2018, z. 90 [298], 2; 187-194
0209-2689
2300-5211
Pojawia się w:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Residual stress profile determination by the hole-drilling method with calibration coefficients obtained using FEM
Autorzy:
Corrêa, Fábio Junkes
Jahnert, Frederico Alves
Tomás, Jucélio Pereira
Powiązania:
https://bibliotekanauki.pl/articles/2055064.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
semi-destructive methods
linear elasticity theory
finite element method
matrices of calibration coefficients
Opis:
Residual Stresses (RS) in mechanical components can be undesirable, and their accurate identification can prevent component damage. There are many semi-destructive methods for determination of RS. The hole-drilling method offers many advantages when compared to other methods due to its practicality, applicability to different materials, and low-cost execution. According to the American Society for Testing and Materials (ASTM) E837- -13a Standard, the RS are assumed to be constant at each depth level when employing the hole-drilling method. Thus, calibration coefficients are necessary to calculate stress values at each level using the relaxed strains measured on the component surface, as incremental drillings are performed. However, the coefficients provided by the Standard were obtained using a coarsely-discretized 2D finite element model. This work aims to find new calibration coefficients based on the linear elasticity theory and using the Finite Element Method (FEM) with a refined mesh. A numerical model consisting of linear tetrahedral finite elements was constructed to simulate the resulting strains, as unitary stresses are applied at each depth level of the component inner surface. Using this method, two matrices of calibration coefficients are obtained, one related to normal stresses, and another related to shear stresses. The results show that the RS obtained using the new coefficients presented a 3.9% relative average error compared to analytical values in the four experiments conducted, while the ASTM Standard coefficients resulted in a 9.7% relative average error.
Źródło:
Journal of Theoretical and Applied Mechanics; 2021, 59, 4; 661--673
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of development tendencies of metrological technologies to control rangefinders of an electronic distance measurement instruments
Autorzy:
Burachek, Vsevolod
Khomushko, Dmytro
Tereshchuk, Oleksiy
Kryachok, Sergíy
Belenok, Vadim
Powiązania:
https://bibliotekanauki.pl/articles/43852820.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
kalibrowanie
dalmierz
błąd pomiaru odległości
calibration
rangefinder
electronic distance measurement
reference linear station
root mean square
error distance measurement
Opis:
The article analyses the development of metrological control technologies for electronic distance measurement rangefinders to determine their main characteristic of accuracy – the root mean square error of distance measurement. It is established that the current reference linear bases are reliable and serve as the main means of transmitting a unit of length from the standards to the working means of measuring length. The article describes the existing linear reference bases and specifies their accuracy and disadvantages. It is concluded that the disadvantages of linear reference bases are deprived of the reference linear bases built in special laboratories. They use distances measured by the differential method with laser interferometers as reference distances. The application of such technology allowed to automate the processes of measurements and calculations. There is development of fibre-optic linear bases, in which optical fibres of known length are used as model lines. The article offers a new technical solution – a combination of fiber-optic and interference linear bases, which allows to qualitatively improve the system of metrological support of laser rangefinders. This is achieved by having a fiber-optic unit, which allows you to create baselines of increased length, while ensuring small dimensions of the baseline, and relative interference base, which provides high accuracy of linear measurements and does not require calibration of the base with a precision rangefinder, which eliminates several difficulties associated with changes in the refractive index, makes measurements independent of the wavelength of the radiation source and almost independent of the ambient temperature.
Źródło:
Advances in Geodesy and Geoinformation; 2022, 71, 1; art. no. e13, 2022
2720-7242
Pojawia się w:
Advances in Geodesy and Geoinformation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quantification of triazine herbicides using chloroplasts in conjunction with thin-layer chromatography
Autorzy:
Broszat, M.
Ernst, H.
Spangenberg, B.
Powiązania:
https://bibliotekanauki.pl/articles/363070.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
połączone analizy bioefektywne
derywatyzacja
HPTLC
liniowy zakres kalibracji
kwantyfikacja
TLC
herbicydy triazynowe
video densytometria
bioeffective-linked analysis
derivatization
linear calibration range
quantification
triazine herbicides
videodensitometry
Opis:
We present a video-densitometric quantification method for the triazine herbicides atraton, terbumeton, simazine, atrazine and terbutylazine. Triazine herbicides were separated on silica gel using methyl-t-butyl ether, cyclohexane (1+1, v/v) as mobile phase. The quantification was based on a bioeffective-linked analysis using chloroplast and 2,6-dichlorophenolindophenol. Within 1-2 minutes HILL-reaction inhibitor substances show blue-grey zones on a pale yellowgreen background. To increase the contrast, the moist plate can be dipped into a solution of PEG-600 (10% PEG-600 in methanol) for 2s. Measurements were carried out using a 16 bit ST-1603ME CCD camera with 1.56 megapixels (from Santa Barbara Instrument Group, Inc., Santa Barbara, USA). A white LED was used for illumination purposes. The range of linearity covers more than one magnitude using the (1/R) - 1 expression data transformation. The method can be used for herbicide screenings in environmental samples, because not spectral sensitivity but herbicide activity is measured. The separation method is cheap, fast and reliable.
Źródło:
Environmental Biotechnology; 2011, 7, 2; 47-52
1734-4964
Pojawia się w:
Environmental Biotechnology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies