Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "lightning protection" wg kryterium: Temat


Wyświetlanie 1-38 z 38
Tytuł:
Annual Variation Trend of Lightning Flash Activities over Sri Lanka
Autorzy:
Maduranga, U. G. Dilaj
Edirisinghe, Mahesh
Gamage, L. Vimukthi
Powiązania:
https://bibliotekanauki.pl/articles/1158876.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
LIS
Lightning flash density
Lightning protection
TRMM
Opis:
The variation of the lightning activities over Sri Lanka and surrounded costal belt (5.75ºN-10.00ºN and 79.50ºE-89.00ºE) is studied using lightning flash data of Lightning Imaging Sensor (LIS) which was launched in November 1997 for NASA’s Tropical Rainfall Measuring Mission (TRMM). The LIS data in the period of 1998 to 2014 are based on this study and there were 23838 lightning flashes over the landmass covered by Sri Lanka during considered period. The data show that average flash density has an increasing trend of 0.093 flashes km-2 year-1. The linear trend is shown in annual flash count with the fitted straight line. Although there is a slight variation between years, there is a clearly increasing trend with 24 flashes per year. There is an incremental trend in distributing of lightning activities all over the country with time. Warming trends of surface temperature and atmosphere may have a correlation with increasing trend of the lightning activities over Sri Lanka and surrounded costal belt.
Źródło:
World Scientific News; 2018, 114; 256-264
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wyników rejestracji wyładowań atmosferycznych na projektowanie ochrony odgromowej
Influence of lightning discharge record results on lightning protection designing
Autorzy:
Wojtas, S.
Olesz, M.
Powiązania:
https://bibliotekanauki.pl/articles/266544.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyładowania atmosferyczne
ochrona odgromowa
lightning discharge
lightning protection
Opis:
W referacie przedstawiono systemy i wstępne wyniki współczesnych rejestracji parametrów wyładowań atmosfe-rycznych na obszarze Polski. Podstawą tych rozważań są wyniki uzyskane z systemu rejestracji LINET, którego jedna z anten znajduje się na terenie Politechniki Gdańskiej. Parametry wyładowań atmosferycznych otrzymane współczesnymi metodami rejestracji antenowych zostały porównane z rejestracjami przeprowadzanymi metodami klasycznymi w ubiegłym wieku. Dotyczy to zwłaszcza gęstości powierzchniowej oraz amplitudy prądu wyładowań atmosferycznych. Prezentowane wstępne wyniki rejestracji wskazują, że gęstość powierzchniowa występowania wyładowań jest większa, a amplituda prądu mniejsza od wartości oszacowanych metodami klasycznymi i wpisanych do aktów normatywnych.
The paper deals with systems as well as initiated results of lightning detection in Poland. A basic results of the presentation are gen-eral characteristics of the LINET system. One of its sensors has been installed in Gdańsk University of Technology. Lightning current parameters obtained using present methods have been compared with those obtained about a half century ago by classic methods. A prob-lems to be taken into consideration refers to both surface density of lightning strokes and their current amplitudes. Presented results indi-cate, that a surface density of lightnings seems to be higher than that obtained by classic methods and their amplitudes seem to be lower in comparison to those evaluated in previous century and introduced to standard regulations. Lightning flash localization and detection results can have an influence on lightning protection system design methods in future.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2010, 27; 125-130
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ochrona odgromowa obiektów budowlanych i ich wyposażenia
Lightning protection of buildings and their equipment
Autorzy:
Flisowski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/317670.pdf
Data publikacji:
2013
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
ochrona odgromowa
piorunowa wrażliwość obiektów
uwarunkowania prawne ochrony odgromowej
lightning protection
lightning vulnerability to building objects
legal conditions for lightning protection
Opis:
Celem artykułu jest zwrócenie uwagi na specyficzne zagadnienia związane z ochroną obiektów budowlanych i ich wyposażenia przed oddziaływaniem wyładowań piorunowych. Poruszono też kwestie związane z normalizacją w ochronie odgromowej, istniejącym chaosem prawnym, nieodpowiednią reakcją urzędów państwowych, brakiem profesjonalizmu oraz ignorancją instalatorów i inspektorów nadzoru. Omówiono także zagadnienia związane z wrażliwością obiektów i wyposażenia na wyładowania piorunowe, wybiórczością piorunów przez zwody oraz bezpiecznym odprowadzaniem prądu wyładowania do ziemi.
An article draws attention to specific issues related to the protection of buildings and their equipment from the lightning strikes. Issues related to standardization in lightning protection, the existing legal chaos, inadequate response to the civil service, lack of professionalism and ignorance installers and inspectors are addressed. The paper also discussed issues related to sensitive facilities and equipment to lightning strikes, lightning selectivity by rods and the safe discharge of static electricity to the ground.
Źródło:
Telekomunikacja i Techniki Informacyjne; 2013, 1-2; 68-86
1640-1549
1899-8933
Pojawia się w:
Telekomunikacja i Techniki Informacyjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania zagrośeń piorunowych systemów elektronicznych
Research on lightning threat in electronic systems
Autorzy:
Markowska, R.
Augustyniak, L.
Sowa, A.
Wiater, J.
Powiązania:
https://bibliotekanauki.pl/articles/267458.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ochrona odgromowa
przepięcie atmosferyczne
zagrożenie piorunowe
lightning protection
lightning overvoltages
lightning threat
Opis:
Od kilkudziesięciu lat podejmowane są próby oceny zagrożeń piorunowych urządzeń elektrycznych i elektronicznych. W prowadzonych badaniach szczególna uwaga jest zwrócona na zjawiska zachodzące podczas bezpośrednich wyładowań piorunowych w różnorodne obiekty budowlane, w których pracują systemy elektroniczne. W takich przypadkach do wyznaczania występujących zagrożeń piorunowych można zastosować kompleksową metodę analizy zachodzących zjawisk. Podstawę tej metody stanowią badania symulacyjne prowadzone w rzeczywistych obiektach. Wyniki badań terenowych wykorzystano przy tworzeniu modeli matematycznych oddziaływania prądów piorunowych na systemy elektroniczne.
The paper presents an overview on different research methods of lightning threat in electronic systems and equipment. These methods were divided in three major groups. The first group refers to measurements and registration of lightning currents and voltages generated during natural or triggered lightning strikes. Not many results of such investigations is available so far due to technical, economical and natural restrictions or limitations. Such researches are usually carried out for tall or large structures located in tropical areas. The second group of research on lightning threat consists of approximate, simulation methods in which surge current and voltage generators are used to force surge current flows in conductive elements of a building or a structure. Surge currents and voltages generated in wires and cables of electronic and electric systems using this method were recorded in various structures. Some example results are presented for large buildings, base stations of mobile communication system and high-voltage substations. Finally, the computer simulation methods of research on lightning threat are presented. The most widely known methods, namely the circuit method and the method based on electromagnetic field theory, are described in detail together with some examples of modeling of lightning strikes to the base station communication tower and the high-voltage substation.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2008, 24; 89-94
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany zasad ochrony odgromowej obiektów budowlanych według norm serii PN-EN 62305
Changes of lighting protection principles of buildings according to standards of PN-EN 62305 series
Autorzy:
Boryń, H.
Olesz, M.
Powiązania:
https://bibliotekanauki.pl/articles/266556.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ochrona odgromowa
zalecenia normalizacyjne
lightning protection
standard recommendations
Opis:
W pracy przedstawiono aktualne podstawy prawne projektowania i wykonywania systemów ochrony odgromowej i przeciwprzepięciowej w obiektach budowlanych. Wskazano nowe zasadnicze zalecenia norm serii PN-EN 62305, które zastąpiły dotychczas stosowane przedmiotowe normy krajowe i międzynaro-dowe. Zwrócono szczególna uwagę na ocenę ryzyka szkód pioru-nowych w obiektach budowlanych i instalacjach związanych.
The paper presents the current legal basis for the design and implementation of lightning and surge protection systems for buildings. It identifies new recommendations of PN-EN 62305 standards, which replaced the previously used national or international standards. Special attention was paid to assess the risk of lightning damage in the buildings and involved instal-lations.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2010, 27; 97-104
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena uziemień odgromowych metodami: udarową i wysokoczęstotliwościową
Lightning earthing evaluation by impulse and high frequency methods
Autorzy:
Wojtas, S.
Powiązania:
https://bibliotekanauki.pl/articles/154029.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
uziemienia odgromowe
pomiary uziemień
lightning protection earthings
earthing tests
Opis:
Uziemienia odgromowe przeznaczone do odprowadzania do ziemi prądów piorunowych pracują w zakresie znacznie szybszych przebiegów (žs) niż uziemienia robocze (ms), a więc wymagają innych metod badań, zwłaszcza uwzględniających spadki indukcyjne w systemie uziemiającym. Wyniki uzyskane metodami udarową i wysokoczęstotliwościową są zbieżne i pozwalają na dobrą ocenę przydatności uziemień do celów ochrony odgromowej. Pomiary takie mogą być przeprowadzane bez konieczności rozłączania zacisków kontrolnych.
A safety earthing designed for short circuit currents is not always good enough to carry away lightning current. For lightning protection purposes impedance of earthing, instead of its resistance, should be taken into account. Dynamic changes of these groups are very different. The duration of an instantaneous state is in the order of milliseconds and the duration of lightning is in microseconds. Because the times of these phenomena differ so much, technical protection means and methods for tests of the means must be properly chosen for a given situation. The impulse and high frequency methods allow for evaluation of lightning protection installations. Impulse impedances of eartings measured in the time domain by an impulse meter are comparable to those measured by a high frequency meter in the frequency domain (Fig. 3 and 4). The impulse and high frequency methods allow for evaluation of lightning protection installations of different objects without disconnections of testing terminals of the installation (Fig. 8).
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 4, 4; 106-109
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ochrona odgromowa dużych obiektów sportowych na przykładzie stadionu PGE ARENA w Gdańsku
Lightning protection system of large sport structure on example of the PGE ARENA stadium in Gdansk
Autorzy:
Boryń, H.
Omilian, L.
Omilian, P.
Powiązania:
https://bibliotekanauki.pl/articles/266685.pdf
Data publikacji:
2011
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
stadiony
ochrona odgromowa
ochrona przeciwprzepięciowa
stadiums
lightning protection system
surge protection
Opis:
W artykule przedstawiono specyfikę ochrony dużych obiektów sportowych przed skutkami wyładowań atmosferycznych. Omówiono zasady ochrony tych obiektów przed bezpośrednim uderzeniem pioruna oraz sposoby ograniczenia przepięć powstających w instalacjach elektroenergetycznych oraz sterujących i pomiarowych zainstalowanych w takich obiektach. Wskazano konieczność indywidualnego rozwiązywania systemów ochronnych.
This paper presents the specific protection of the larger sport structure against lightning strokes. Protection principles of such structures against both direct lightning strokes as well as ways surge protection in the power, control and measurement installations are discussed. It has been stated that the individual protective systems are needed.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2011, 29; 11-16
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zmian zasad oceny zagrożenia piorunowego na potrzebę stosowania ochrony odgromowej i jej kategorię
Influence of changes of lightning threat assessment principles on the need of lightning protection and its category
Autorzy:
Maksimowicz, T.
Zielenkiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/266629.pdf
Data publikacji:
2014
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ochrona odgromowa
zagrożenie piorunowe
analiza ryzyka
lightning protection
lightning threat
risk assessment
Opis:
Na przestrzeni ostatnich dekad wraz ze zmianami aktów normalizacyjnych w zakresie ochrony odgromowej transformacji ulegały także procedury, według których podejmowana jest decyzja o potrzebie stosowania instalacji odgromowej obiektów budowlanych. W artykule przedstawiono przegląd praktyk oceny zagrożenia piorunowego w normach dotyczących ochrony odgromowej poczynając od normy PN-E05003:1986 i kończąc na aktualnej drugiej edycji norm PN-EN 62305-2:2012, dokonano porównania poszczególnych toków postępowania ze wskazaniem ich wad i zalet, a także zamieszczono przykłady wyników oceny potrzeby stosowania i doboru kategorii instalacji odgromowej według różnych norm dla typowych obiektów budowlanych. Przedstawiona analiza obliczeń zagrożenia piorunowego pokazuje, iż różne procedury oceny ryzyka kolejnych wersji omawianych norm dają odmienne wyniki.
Principles of lightning threat assessment for buildings have changed seriously with revision of normative documents regarding lightning protection in Poland over the last few decades. This paper presents review of principles according to lightning protection standards from PN-E-05003:1986 to PN-EN 62305-2:2012. All the procedure has been compared with indication of advantages and disadvantages of each of them. Examples of results of lightning threat assessment for typical buildings like country house, office building, hospital, industrial hall and radio and television broadcasting centre are presented and compared. According to different standards different results can be obtained.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2014, 39; 29-36
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozległe systemy uziemień w ochronie odgromowej
Wide earthings in lightning protection systems
Autorzy:
Wojtas, S.
Powiązania:
https://bibliotekanauki.pl/articles/266802.pdf
Data publikacji:
2011
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ochrona odgromowa
pomiary uziemień
impedancja uziemienia
lightning protection
earthing tests
Opis:
W artykule zostały omówione procedury i wyma-gania stawiane systemom uziemień przez przepisy normalizacyjne z punktu widzenia ich skuteczności w systemie ochrony odgromowej. Podstawą tak sformułowanej oceny są pomiary z zastosowaniem metody udarowej. Metoda taka okazuje się bardzo przydatna zwłaszcza w przypadku uziemień rozległych, jakie pojawiają się we współczesnych obiektach wskutek połączenia różnych elementów uziemiających za pomocą wspólnej szyny wyrównania potencjałów. Analizowana metoda pozwala nie tylko na pomiar impe-dancji wypadkowej systemu uziemień, ale także na ocenę stanu połączeń poszczególnych elementów tego systemu.
The paper deals with procedures and requirements up to standards for earthings from the point of view of their effectiveness in lightning protection systems. Impulse mesurements of earthings prove to be a base of such evaluations. The impulse methode is especially useful in the case of very wide earthings. Such earthing systems are created in modern struc-tures due to equipotential bars connecting all earthing elements entering the structure. The presented method makes earthing impedance mesurements possible as well as quality evaluation of earthing element connections.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2011, 29; 29-34
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Szporowskie korzenie Katedry Wysokich Napięć i Aparatów Elektrycznych Politechniki Gdańskiej
Szpors roots of the school of high voltages and electrical apparatus of Gdansk University of Technology
Autorzy:
Wolny, A.
Powiązania:
https://bibliotekanauki.pl/articles/267439.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
technika wysokich napięć
ochrona odgromowa
piorunochrony
high voltage technique
lightning protection
lightning arrester
Opis:
Przedstawiono zwięzłą historię katedry utworzonej przez prof. S. Szpora na Politechnice Gdańskiej, rozwój zespołu badawczego i najważniejsze osiągnięcia. Pokazano aktualny stan katedry, która wyrosła na fundamentach zbudowanych przez Profesora i tematykę badawczą realizowaną przez pokolenie, czerpiące swą wiedzę od Jego uczniów.
A concise high voltage school history created by prof. Szpor at the Gdańsk University of Technology, as well as its research team development and achievements have been presented. Present activity of the school grown on the foundation layed down by the Professor, and the problems investigated by the generation tought by His disciples has been described.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2008, 24; 1-6
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ochrona odgromowa fotowoltaicznych źródeł energii elektrycznej
Lightning protection of photovoltaic sources of electric energy
Autorzy:
Boryń, H.
Powiązania:
https://bibliotekanauki.pl/articles/266515.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
panele fotowoltaiczne
ochrona odgromowa
ochrona przeciwprzepięciowa
photovoltaic panels
lightning protection
surge protection
Opis:
W artykule przedstawiono specyfikę ochrony paneli fotowoltaicznych zainstalowanych na dachu obiektu budowlanego lub wykorzystanych w elektrowniach słonecznych przed skutkami wyładowań atmosferycznych. Omówiono zasady ochrony tych urządzeń przed bezpośrednim uderzeniem pioruna i sposoby ograniczenia przepięć powstających w instalacjach elektroenergetycz-nych oraz sterujących i pomiarowych współpracujących z panela-mi. Wskazano konieczność indywidualnego rozwiązywania syste-mów ochronnych.
This paper presents the specific protection against lightning of photovoltaic panels installed on the roof of a building, or used in solar power stations. The principles of protection against direct lightning stroke of these devices and ways to re-duce the effect of the overvoltages in the power, control and measurement installations, cooperating with PV panels are pre-sented. It is stated that the individual protective systems are needed.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2010, 27; 21-26
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wymagania dotyczące wewnętrznej ochrony odgromowej obiektów budowlanych
Requirements for internal lightning protection systems in building constructions
Autorzy:
Lenartowicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/183096.pdf
Data publikacji:
2009
Wydawca:
Instytut Techniki Budowlanej
Tematy:
obiekt budowlany
ochrona odgromowa
ochrona przeciwprzepięciowa
norma
terminologia
wymagania techniczne
ekranowanie
eliminacja pętli indukcyjnej
instalacja piorunochronna
strefa ochrony odgromowej
urządzenie ochrony przepięciowej
przepięcie
building
lightning protection
surge protection
technical requirements
screening
inductive loop elimination
lightning protection system
lightning protection zone
surge protective device
Opis:
W dziedzinie wewnętrznej ochrony odgromowej i przepięciowej wprowadzono ostatnio wiele nowych wymagań. Wymagania te są zawarte we wprowadzanych stopniowo do realizacji nowych normach. W artykule przedstawiono aktualny stan normalizacji w zakresie ochrony odgromowej i przepięciowej. Opisano wprowadzone przez normy nowe pojęcia i definicje. Podano zalecane wymagania dotyczące takich preferowanych w wewnętrznej ochronie odgromowej środków ochrony, jak ekranowanie, eliminacje pętli indukcyjnych, połączenia wyrównawcze, uziemienia i inne. Omówiono także wymagania związane ze strefową ochroną odgromową (LPZ) i stosowanymi urządzeniami (SPD).
In the field of internal lightning and overvoltage protection, a new requirements were introduced recently. There requirements are given in a newly implemented standards. The present state of standards describing the lightning and overvoltage protection is shown, as well as a new terms and definitions. It also contains the basic requirements for internal lightning protection such as screening, inductive loop elimination, equipotential bondings, earthing. The paper also describes requirements for zonal lightning protection (LPZ) and the system of protection devices (SPD). The last part of paper contains the conclusions resulting from carried out research work.
Źródło:
Prace Instytutu Techniki Budowlanej; 2009, R. 38, nr 2, 2; 31-52
0138-0796
Pojawia się w:
Prace Instytutu Techniki Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sniženie vliâniâ grozovyh proâvlenij na obʺektah agropromyšlennogo kompleksa putem soveršenstvovaniâ harakteristik ih molniezaŝity
Reduction of Storm Consequences on the Agricultural Sector by Improvement to Features of the Protection System Against Lightning Strikes
Redukcja wpływu zjawisk burzowych w obiektach sektora przemysłowo-rolnego poprzez udoskonalenie właściwości systemów ochrony odgromowej
Autorzy:
Skripko, A. N.
Misun, L. V.
Powiązania:
https://bibliotekanauki.pl/articles/373010.pdf
Data publikacji:
2015
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
lightning
lightning protection
lightning conductor
fire
agricultural property
piorun
ochrona odgromowa
piorunochron
pożar
obiekt sektora przemysłowo-rolnego
Opis:
Aim: Identification of solutions, which increase the effectiveness of protection against direct lightning strikes, by taking account of past experience associated with agricultural property, which was exposed to the impact of storms. Introduction: Each year, in the Republic of Belarus, many fires are caused by lightning strikes. As a result buildings used by the public and for industrial purposes are exposed to damage. These include storage facilities for flax and fodder. Additionally, animals and birds die. During the years 2001-2013 there were 46 fires in Belarus, which affected buildings and items from the agro-industrial sector, of which 43 were as the result of direct lightning strikes and 3 related to secondary causes. The biggest proportion of fires were caused by direct lightning strikes. The basic approach used to protect buildings from lightning strikes is by utilising lightning conductors [1–2]. During a period of use, protective properties of lightning conductors may undergo a change, caused by the influence of external factors. Such a change may reduce the size of a protected area with a consequential impact on the safety of a building or other item in the vicinity at the moment of a lightning strike. Methods: In order to examine the impact on the safety of buildings and other property, caused by changes to properties of lightning conductors, research was performed with the aid of data analysis, of fires caused by lightning strikes and by observation of changes to properties of lightning conductors. Based on passive experiments a mathematical model was developed for use in forecasting, to determine the potential for property to avoid the consequences of fires caused by storms and a model, which could describe the effective operation of a lightning conductor. A technical solution was proposed for the construction of a lightning conductor, which would protect property from a direct lightning strike. A study of lightning conductors was performed, including the registration of changes to their protection properties. Conclusions: The choice of optimum technical data, for a protection device against direct lightning strikes, was justified. This data provided a basis for the development of an experimental lightning conductor model. Furthermore, research identified limit values applicable to changes in the properties of lightning conductors, with the aim of modifying methods of describing the protection range of lightning conductors and introduction of appropriate amendments to fire prevention regulations and norms in Belarus. Implications for practice: The development of a technical solution, to deal with protection against lightning strikes, particularly for business properties, provides a level of stable and lasting security and eliminates the problem associated with a reduction in the protective range of lightning conductors.
Cel: Wskazanie rozwiązań zwiększających efektywność środków ochrony przeciw bezpośredniemu uderzeniu pioruna z uwzględnieniem negatywnych doświadczeń z eksploatacji obiektów gospodarczych związanych z oddziaływaniem na nie zjawisk burzowych. Wprowadzenie: W Republice Białorusi co roku dochodzi do pożarów spowodowanych uderzeniem piorunów. W wyniku tych pożarów zniszczeniu ulegają budynki produkcyjne oraz budynki i obiekty użyteczności publicznej, magazyny paszy objętościowej i lnu, giną zwierzęta, w tym ptaki. W latach 2001-2013 na terytorium Białorusi doszło do 46 pożarów w budynkach i obiektach sektora przemysłowo- rolnego, 43 z nich wskutek bezpośredniego uderzenia pioruna, a 3 od jego wtórnego oddziaływania. Największy odsetek stanowią pożary powstałe wskutek bezpośredniego uderzenia pioruna. Podstawowymi metodami ochrony obiektów od tego rodzaju zagrożenia są piorunochrony [1–2]. W czasie eksploatacji piorunochronów, z uwagi na oddziaływanie czynników zewnętrznych, ich właściwości ochronne mogą ulec zmianom. Odchylenia piorunochronów mogą powodować zawężenie strefy objętej ochroną, wpływając w ten sposób na bezpieczeństwo budynku lub obiektu w momencie uderzenia piorunu. Metody: Aby zbadać wpływ zmian właściwości piorunochronów na bezpieczeństwo budynków i obiektów, przeprowadzone zostały badania, których podstawą była analiza danych statystycznych na temat pożarów powstałych wskutek uderzenia pioruna oraz obserwacje zmian właściwości piorunochronów. Na podstawie przeprowadzonych biernych eksperymentów opracowany został model matematyczny do prognozowania odporności budynków lub obiektów na pożary powstałe w wyniku zjawisk burzowych oraz model matematyczny skutecznej pracy piorunochronu. Zaproponowano rozwiązanie techniczne budowy piorunochronu, który zapewniłby ochronę obiektu przed bezpośrednim uderzeniem piorunu. Przeprowadzono obserwacje piorunochronu, w tym rejestrację jego odchyleń od osi ochrony. Wyniki: Uzasadniono dobór optymalnych parametrów technicznych dla urządzenia zabezpieczającego przed bezpośrednim uderzeniem pioruna, na podstawie których opracowano model eksperymentalny piorunochronu. Określono wartości graniczne dla zmian właściwości piorunochronu w celu opracowania zmian metodologii określania zasięgu ochrony piorunochronów, wprowadzenia odpowiednich poprawek w wymaganiach norm przeciwpożarowych i standaryzacji na Białorusi. Znaczenie dla praktyki: Stosowanie w obiektach gospodarczych: opracowanie rozwiązania technicznego w zakresie ochrony odgromowej, zapewniającego stabilną i trwałą ochronę, wyeliminowanie problemu zmniejszenia zasięgu ochrony piorunochronu.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2015, 2; 113-124
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lightning Strike Protection of Aircraft Composite Structures: Analysis and Comparative Study
Autorzy:
Katunin, A.
Powiązania:
https://bibliotekanauki.pl/articles/97865.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
lightning strike protection
conductive composite
aircraft structures
Opis:
Lightning strikes are a serious problem during operation of aircraft due to the increasing applicability of polymeric composites in aircraft structures and the weak electrical conducting properties of such structures. In composite structures, lightning strikes may cause extended damage sites which require to be appropriately maintained and repaired leading to increased operational costs. In order to overcome this problem various lightning strike protection solutions have been developed. Some of them are based on the immersion of metallic elements and particles while others use novel solutions such as intrinsically conductive polymers or other types of highly conductive particles including carbon nanotubes and graphene. The concept of fully organic electrically conductive composites based on intrinsically conductive polymers is currently being developed at the Silesian University of Technology. The results obtained in numerous tests, including concerning electrical conductivity and the capability to carry on high-magnitude electrical charges as well as certain operating properties need to be compared with existing solutions in lightning strike protection of aircraft. The following study presents the properties of the material developed for lightning strike protection and a comparative study with other solutions.
Źródło:
Fatigue of Aircraft Structures; 2016, 8; 49-54
2081-7738
2300-7591
Pojawia się w:
Fatigue of Aircraft Structures
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ryzyko uszkodzeń instalacji i urządzeń turbin wiatrowych spowodowanych wyładowaniami atmosferycznymi
Risk of installations and wind turbines damage caused by lightning strike
Autorzy:
Głogowski, P.
Orymowska, J.
Pilip, K.
Powiązania:
https://bibliotekanauki.pl/articles/311243.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
turbina wiatrowa
ochrona odgromowa
wyładowania atmosferyczne
wind turbine
lightning protection
atmospheric discharges
Opis:
Wszystkie koncepcje ochrony odgromowej oparte są na teorii, że uszkodzenia popiorunowe będą najmniejsze wówczas, gdy impedancja elementów odprowadzających ładunek do podłoża będzie możliwie mała. Zastosowanie ścieżek małej impedancji powoduje, że prądy piorunowe zwykle nie docierają do elementów podatnych na uszkodzenia. Ochrona odgromowa łopat, łożysk, agregatu prądotwórczego i podzespołów elektronicznych wymaga, aby zapewnione było skuteczne uziemienie. W artykule przeanalizowano istniejące przepisy i regulacje definiujące co to oznacza oraz wskazano przykładowe sposoby jak je realizować w praktyce.
All lightning protection concepts are based on the theory that the lightning bolts will be the smallest when the impedance of the discharge elements to the ground will be as small as possible. Applying low impedance paths causes lightning currents to fail to reach the susceptible components. Lightning protection for blades, bearings, generator sets and electronic components requires effective grounding. The article discusses the existing rules and regulations defining what does it mean and shows examples how to implement it in practice.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 12; 880-884, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza rozpływu prądu udarowego w urządzeniu piorunochronnym i dołączonych instalacjach
Analysis of impulse current distribution in lightning protection system and connected installations
Autorzy:
Masłowski, G.
Wyderka, S.
Karpiński, L.
Ziemba, R.
Karnas, G.
Filik, K.
Szczupak, P.
Powiązania:
https://bibliotekanauki.pl/articles/267223.pdf
Data publikacji:
2014
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyładowania atmosferyczne
ochrona odgromowa
badania poligonowe
prąd udarowy
lightning
lightning protection
test site experiments
impulse current
Opis:
W artykule przedstawiono poligon badawczy systemów ochrony odgromowej należący do Politechniki Rzeszowskiej. Przeprowadzono badania rozpływu prądów udarowych w urządzeniu piorunochronnym obiektu budowlanego i dołączonej instalacji. W badaniach wykorzystano mobilny generator udarów prądowych i oryginalny system pomiarowy. Uzyskane wyniki potwierdzają rejestracje dokonane na Florydzie z wykorzystaniem wyładowań atmosferycznych prowokowanych. Kształty fal prądowych nie są jednakowe w różnych miejscach badanego układu i zależą od parametrów częstotliwościowych poszczególnych elementów instalacji, natomiast efektywność odprowadzania prądu piorunowego do ziemi przez urządzenie piorunochronne zależy od relacji między wartościami impedancji uziemienia obiektu budowlanego i uziemienia najbliższej stacji transformatorowej.
The paper presents a new test site of lightning protection systems belonging to the Rzeszow University of Technology. Analysis of impulse current distribution in the lightning protection system and the connected installations has been conducted. An impulse current generator was used together with the original measurement system during experimental tests. Obtained results confirm registrations made in Florida with usage of triggered lightning experiments. Current waveforms are not the same in lightning protection system and are influenced by frequency dependent parameters of different parts of the installation. The effectiveness of lightning protection system depends on the relation between the amount of impedances of the local grounding system and the grounding system of the transformer station.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2014, 39; 41-45
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the effectiveness of lightning and surge protection in a large solar farm
Autorzy:
Sobolewski, Konrad
Sobieska, Emilia
Powiązania:
https://bibliotekanauki.pl/articles/2086693.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ANSYS simulations
electric safety
grounding system
magnetic field distribution
lightning modeling
lightning protection
photovoltaic power plant
Opis:
The aim of the considerations presented in the article was a stand-alone groundbased photovoltaic power plant. The article is devoted to the qualitative analysis of some lightning protection configurations. These types of constructions often require an individual look at the design and execution of lightning protection installations, which causes problems with the selection of optimal solutions. These problems relate primarily to the way the lightning rods are arranged to create protection zones, but also to the way they are attached: to the supporting structure for PV modules or as free-standing. Another problem raised in the article is the way how lightning current is discharged from rods to the ground and how it is dispersed there. Due to the vast area of such facilities and the requirements for electrical safety, it is necessary to consider and design a ground system with optimal electrical parameters, but also technical and economic ones. All these elements have their impact on the value of voltages induced in the electrical installation, which is also presented in the content of the article as the magnetic field distribution and calculation of induced voltages in an exemplary configuration. Finally, this article will compare described technical solutions encountered in selecting the best protection method for this type of photovoltaic installation.
Źródło:
Archives of Electrical Engineering; 2022, 71, 2; 523--542
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uszkodzenia elektronicznych liczników energii elektrycznej w wyniku niewłaściwego doboru ograniczników przepięć
Energy meters damages as a result of inproper surge protection devices selection
Autorzy:
Wiater, J.
Powiązania:
https://bibliotekanauki.pl/articles/268168.pdf
Data publikacji:
2014
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ograniczniki przepięć
ochrona odgromowa
liczniki energii elektrycznej
lightning protection
energy meters
surge protection devices
SPD
Opis:
W artykule scharakteryzowano narażenia udarowe liczników energii elektrycznej. Zaprezentowano wyniki próby udarowej przyłącza kablowego zasilanego z napowietrznej linii napowietrznej nn zabezpieczonej liniowym ogranicznikiem przepięć. Przyłącze wyposażone zostało w elektroniczny licznik energii elektrycznej. Badanie przeprowadzono dla układu pracującego pod napięciem, z wykorzystaniem prądu udarowego 10/350 μs o wartości szczytowej 3 kA. W wyniku analizy zaobserwowano eksplozję ogranicznika przepięć i uszkodzenie licznika.
Paper describes overvoltage hazard for energy meters. Study were made for circuit that consist of overhead transmission line, low voltage power supply, high voltage current surge generator, surge protection device (SPD) and energy meter. Typical lighting surge current (3 kA; 10/350 μs) where produced by generator and conducted to line. Test were provided for fully functional circuit supplied from isolated from ground power source. As a result of that explosion of SPD were observed. Also energy meter were damaged. Investigation proves that SPD class 2 are not sufficient for energy meter protection which are supplied from overhead transmission lines.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2014, 39; 61-64
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wewnętrzna ochrona odgromowa obiektów zabytkowych
Internal lightning protection in the monumental buildings
Autorzy:
Dłużniewski, A.
John, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/373125.pdf
Data publikacji:
2011
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
ochrona przeciwprzepięciowa
strefowa ochrona przeciwprzepięciowa
udar elektryczny
electric surge
lightning protection zone
surge protectors
Opis:
W artykule omówiono zasady ochrony urządzeń elektrycznych i elektronicznych znajdujących się w obiektach zabytkowych przed przepięciami. Ochrona przeciwprzepięciowa polega na zastosowaniu strefowej koncepcji ochrony urządzeń i systemów. Opisano podstawowe zasady ekranowania i prowadzenia instalacji elektrycznej i transmisji sygnałów w celu uniknięcia sprzężeń pomiędzy instalacjami znajdującymi się w zabytkowym obiekcie. Podano przykłady ochrony urządzeń elektronicznych znajdujących się w starych dworkach ze względu na ich znaczenie kulturalne. Pokazano również przykłady zabezpieczenia przed przepięciami systemów i urządzeń znajdujących się w zabytkowym obiekcie kolejowym na przykładzie nastawni dyspozytorskiej, które przystosowano do instalowania nowoczesnych urządzeń elektronicznych.
The article discusses the principle of protection of electrical and electronic equipment located in monumental buildings before the surge. Surge Protection is the partition using the concept of security devices and systems. Describes the basic principles of screening and conduct electrical signals and to avoid linkage between installations located in the monumental building. Protection are examples of electronic devices located in the old manor monumental because of their cultural significance. Showing examples of surge protection systems and equipment located in a historic building on the example of railway control room dispatcher, which is adapted to the installation of modern electronic devices.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2011, 1; 151-162
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania wysokonapięciowe na Wydziale Elektrycznym Politechniki Warszawskiej. Rys historyczny i stan obecny
High voltage investigations performed on the Electrical Engineering Faculty of Warsaw University of technology short history and present state
Autorzy:
Flisowski, Z.
Rawa, H.
Powiązania:
https://bibliotekanauki.pl/articles/267399.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
technika wysokich napięć
ochrona odgromowa
kompatybilność elektromagnetyczna
high voltage technology
lightning protection
electromagnetic compatibility
Opis:
Referat ma charakter jubileuszowy, opracowany dla uczczenia setnej rocznicy urodzin Prof. Stanisława Szpora. Podano w nim krótki rys historyczny z sygnalną informacją o głównych kierunkach powojennych badań wysokonapięciowych na Wydziale Elektrycznym Politechniki Warszawskiej i przedstawiono niektóre zagadnienia naukowe i dydaktyczne z zakresu zainteresowań członków Zespołu Techniki Wysokich Napięć w poprzednim Instytucie i obecnej Katedrze Wysokich Napięć i Aparatów Elektrycznych. Skoncentrowano się głównie na zagadnieniach szeroko rozumianej ochrony odgromowej i przepięciowej zwracając uwagę na zdalną rejestrację wyładowań piorunowych, ocenę ryzyka szkód piorunowych i jej standardowe uproszczenia i skuteczność redukcji tego ryzyka za pomocą ekranów przestrzennych i urządzeń do ograniczania przepięć (SPD), jako głównych środków ochrony. Nawiązano też do kompatybilności elektromagnetycznej z uwagi na specyfikę ochrony urządzeń wrażliwych na zakłócenia elektromagnetyczne.
The paper is of jubilee nature, elaborated for the celebration of hundred birthday anniversary of Prof. Stanislaw Szpor. A short history with also short information on the main directions of the postwar high voltage investigations performed at the Electrical Engineering Faculty of Warsaw University of Technology and some of scientific and didactic problems belonging to the area of the interest of the High Voltage Engineering Team members of the former Institute and the present Department of High Voltage Engineering and Electrical Apparatus have been in the paper presented. It has been concentrates mainly on the problems of widely comprehended protection against lightning and overvoltages, giving the attention to the distant registration of lightning discharges, the assessment of the risk of lightning damages and its normative simplifications as well as the efficiency of the risk reduction by means of spatial screens and surge protective devices (SPD) being the main protection measures. It has been also referred to the electromagnetic compatibility because of specificity of protection of devices sensitive to the electromagnetic disturbances.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2008, 24; 37-44
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wkład Józefa Hermana Osińskiego w rozwój ochrony odgromowej w Polsce
J. H. Osiński’s contribution in the development of lightning protection in Poland
Autorzy:
Masłowski, G.
Powiązania:
https://bibliotekanauki.pl/articles/267679.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyładowania atmosferyczne
ochrona odgromowa
historia polskiego piśmiennictwa elektrotechnicznego
lightning discharges
lightning protection
history of Polish electrical engineering literature
Opis:
W artykule przedstawiono najważniejsze wydarzenia związane z rozwojem ochrony odgromowej w Polsce i na świecie w drugiej połowie XVIII wieku oraz dokonano charakterystyki pierwszego podręcznika elektrotechniki J. H. Osińskiego „Sposob Ubezpieczaiący Życie y Maiątek od Piorunów", wydanego w Warszawie w 1784 r. Proponowane w podręczniku rozwiązania techniczne porównano z aktualnymi wymaganiami w zakresie ochrony odgromowej. Z przedstawionej analizy dzieła J. H. Osińskiego, będącego syntezą ówczesnego stanu wiedzy, wynika, że jego pionierska praca stanowi bardzo ważną pozycją w historii polskiego piśmiennictwa elektrotechnicznego i może być dzisiaj przykładem wysokiego poziomu technicznego ówczesnego państwa polskiego w nowej dziedzinie ochrony odgromowej.
The paper presents the most important developments related to lightning protection used in Poland and in all over the world in the second half of the eighteenth century. The first Polish electrical engineering handbook published in Warsaw in 1784, and written by J. H. Osiński, "The Way of Protecting Life and Property From Lightning Strikes" has been analysed. Proposed technical solutions in this handbook are compared to the the current requirements of lightning protection. The presented analysis shows that the publication, which is a synthesis of the then state of the art, is a very important work in the history of Polish electrical engineering literature, and that, his pioneering work can be confirmation of a high level of scientific and technical state of the eighteenth-century Polish. After Benjamin Franklin’s inventions, thanks to J. H. Osiński work the principles of life and property protection against lightning direct strikes were formulated in Poland at the same time as in other highly developed countries of Europe. Many technical solutions proposed by J. H. Osiński are still valid and can be used presently in lightning protection of buildings.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 44; 43-48
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aspekty bezpieczeństwa w ocenie wyników pomiarów uziemień odgromowych
Safety problems in assessment of lightning protection earthing test results
Autorzy:
Wojtas, S.
Wołoszyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/266863.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ochrona odgromowa
pomiary uziemień
długość efektywna uziomu
lightning protection
earthing tests
effective length of earthing
Opis:
W wyniku połączenia wszystkich elementów uziemionych w obiekcie budowlanym do szyny ekwipotencjalnej powstaje często bardzo rozległy system uziemień. Ocena tak rozległego systemu za pomocą metod wykorzystujących przebiegi wolnozmienne prowadzi do zbyt optymistycznych wniosków odnośnie ich właściwości podczas odprowadzania prądów wyładowań atmosferycznych. Bardziej bezpieczne wnioski powstają w wyniku pomiarów z zastosowaniem metody wykorzystującej przebiegi impulsowe, ponieważ wtedy jest uwzględniana tylko ta część nawet bardzo rozległego systemu uziemień, która bierze udział w rozpraszaniu prądu piorunowego w ziemi. Tak określona część uziomu jest nazywana jego długością efektywną. Przeprowadzone symulacje komputerowe wskazują, że zwiększanie rozmiarów uziomu poza jego długość efektywną nie wpływa na ograniczanie spadku napięcia na uziomie podczas odprowadzania prądu.
Earthings of the electrical power systems can achieve wide sizes. Due to equipotential bonding and a presence of main equipotential bar the earthing system can be directly connected even to a power transformer neutral point. Evaluation of such wide earthings for lightning protection purposes can not be easy to perform because only a part of the earthing system should be taken into account. This useful part of the earthing is described as its effective length. The paper deals with procedures and requirements up to standards for earthings from the point of view of their effectiveness in lightning protection systems. Impulse measurements of earthings prove to be a base of such evaluations and it is especially useful in the case of very wide earthing systems.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 35; 71-76
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nature of atmospheric discharges
Autorzy:
Aniserowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/317642.pdf
Data publikacji:
2013
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
Lightning Electromagnetic Pulse (LEMP)
lightning phenomenon
protection against lightning
Opis:
This article presents simplified description of the phenomenon of lightning, with special regard to the cloud-toground discharges, and parameters of standardized lightning electromagnetic pulses. Measures of protection against lightning are pointed out. These parameters and measures are important for proper lightning protection of telecommunication facilities.
Źródło:
Telekomunikacja i Techniki Informacyjne; 2013, 1-2; 59-67
1640-1549
1899-8933
Pojawia się w:
Telekomunikacja i Techniki Informacyjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena ciągłości połączeń urządzenia piorunochronnego na podstawie pomiarów metodą udarową
Connection continuity assessment of lightning protection system on the ground of impulse tests
Autorzy:
Wojtas, S.
Powiązania:
https://bibliotekanauki.pl/articles/268854.pdf
Data publikacji:
2014
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ochrona odgromowa
pomiary uziemień
metoda udarowa pomiaru uziemień
lightning protection
earthing test
effective length of earthing
Opis:
Wskutek przyłączenia wszystkich elementów uziemionych związanych z obiektem budowlanym do szyny ekwipotencjalnej powstaje rozległy i skomplikowany układ uziemień. Stosowane powszechnie systemy dociepleń często utrudniają dostęp zacisków kontrolnych urządzenia piorunochronnego obiektu. Ocena parametrów i ciągłości połączeń takiego urządzenia może być trudna do realizacji za pomocą metod klasycznych, które podczas okresowej kontroli wymagają odłączania poszczególnych elementów uziemiających od szyny ekwipotencjalnej oraz rozłączania zacisków kontrolnych. Zaprezentowano wyniki badań na obiektach rzeczywistych popartych symulacjami komputerowymi, które wskazują, że pomiary wykorzystujące metodę udarową mogą być bardzo pomocne w ocenie takich układów ochrony odgromowej. W pracy podano warunki geometryczne obiektu, w których na podstawie pomiarów urządzenia piorunochronnego metodą udarową bez rozłączania zacisków kontrolnych można wnioskować o ciągłości połączeń przewodów uziemiających z uziomem.
Due to connections of all earthing elements associated with a building structure to equipotential bonding a wide and complicated earthing system is created. Commonly used insulation systems often impede access control terminals of object lightning protection device. Parameters and the continuity assessment of such a device may be difficult to achieve using conventional methods that require disconnections of the individual elements of equipotential grounding as well as disconnecting control terminals. The results of tests on real objects supported by computer simulations that indicate that the measurements using impulse method can be very helpful in assessing such harsh lightning protection systems. The paper presents the geometric conditions of the object in which the measurements impact method lightning protection device without disconnecting the control terminals can be inferred about the continuity of the grounding wires from the earthing electrode.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2014, 39; 65-70
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Profesor Szpor i jego Katedra przy ulicy Własna Strzecha
Professor Szpor and his Department at Wlasna Strzecha Street
Autorzy:
Olesz, Marek
Wojtas, Stanisław
Powiązania:
https://bibliotekanauki.pl/articles/268144.pdf
Data publikacji:
2020
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ochrona odgromowa
ochrona przepięciowa
laboratorium wysokich napięć
laboratorium zwarciowe
lightning protection
surge protection
high-voltage laboratory
short circuit laboratory
Opis:
W artykule opisano pierwsze lata rozwoju Katedry Wysokich Napięć, a potem Katedry Wysokich Napięć i Aparatów Rozdzielczych na Wydziale Elektrycznym Politechniki Gdańskiej. Rozwój tej Katedry jest nierozerwalnie związany z osobowością profesora Stanisława Szpora, który po przybyciu do Gdańska w 1947 roku w krótkim czasie zbudował nowoczesne laboratorium wysokich napięć i zwarciownię, co pozwoliło zespołowi naukowemu uzyskać światowej rangi osiągnięcia, zwłaszcza w dziedzinie badań piorunowych i ochrony przepięciowej.
The article describes the first years of development of the High Voltage Department, and then the High Voltage and Switching Apparatus Department at the Faculty of Electrical Engineering at Gdansk University of Technology. The development of this Department is closely related to the personality of Professor Stanisław Szpor. After arriving in Gdańsk in 1947, he quickly built a modern high-voltage laboratory and short-circuit facility, which allowed the research team to achieve world-class achievements especially in the field of lightning research and surge protection.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2020, 69; 29-34
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza sygnatur pola elektrycznego wyładowań atmosferycznych w rejonie Bieszczad na podstawie kompleksowych pomiarów impulsów fali elektromagnetycznej w paśmie częstotliwości od 0 do 3 mhz wykonanych w Akademickim Ośrodku Szybowcowym Politechniki Rzeszowskiej i Politechniki Warszawskiej w Bezmiechowej w maju 2014 r.
Analysis of lightning discharge electric field signatures obtained from the comprehensive measurements of associated electromagnetic pulse radiation in the frequency range from 0 to 3 mhz, carried out at the academic gilder center of the Rzeszów and Warsaw Technical Universities at Bezmiechowa in may 2014
Autorzy:
Sobolewski, K.
Karnas, G.
Barański, P.
Masłowski, G.
Powiązania:
https://bibliotekanauki.pl/articles/266313.pdf
Data publikacji:
2014
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyładowania atmosferyczne
detekcja i lokalizacja wyładowań piorunowych
mechanizm wyładowania piorunowego
ochrona odgromowa
lightning flash
cloud-to-ground lightning stroke
lightning detection and location network
lightning protection
Opis:
W niniejszym artykule przedstawiono kompleksowe pomiary piorunowego pola elektromagnetycznego z równoczesnym wykorzystaniem kilku anten. Przedmiot badań dotyczył incydentu burzowego z dnia 20 maja 2014 r. zarejestrowanego w AOS PRz i PW1 w Bezmiechowej Górnej. Zestaw pomiarowy składał się z dwóch anten pola „szybkiego” (0,.5 Hz - 3 MHz) oraz jednej anteny pola „wolnego” – młynka (0 Hz – 10 Hz). Anteny pola szybkiego pozwoliły na obserwację składowej radiacyjnej, porównanie danych z dwóch identycznych czujników pomiarowych i weryfikację pracy układu wyzwalającego . Dodatkowo na wieży pomiarowej zainstalowano atestowany miernik pola EM Maschek ESM-100 o zakresie 5 Hz – 400 kHz. Umożliwiło to zaobserwowanie dobowych zmian trzech składowych wektora oraz modułu pól elektrycznego i magnetycznego. W artykule przeprowadzono analizę pomiarów z wykorzystaniem programu Matlab, generującego wykresy pola elektromagnetycznego w funkcji czasu.
We have presented in this paper some results obtained from the amplitude-frequency analysis of electric field signatures associated with cloud-to-ground (CG) and intra-cloud (IC) lightning discharges that were recorded in the Bieszczady region during the one-week field campaign. The apparatus set used in this campaign consisted of three electric field sensors, i.e. the fast-track unit that was operated in the frequency range from 0.5 Hz to 3 MHz, the slow-track unit that was operated in the frequency range from 20 Hz to 100 kHz and the field mill with rotating dipole operating in the frequency range from 0 Hz to 10 Hz. Such complete measuring devices have allowed for recoding both the electrostatic, intermediate and radiation components of the electric field changes associated with close and distant lightning flash incidents. Additionally, we have used the certified Maschek meter (type ESM-100) for simultaneous recordings of three vector components and the module of electric and magnetic fields connected with the electromagnetic interferences in the frequency range from 5 Hz to 400 kHz that have occurred during observed thunderstorms. The data stream obtained from the Maschek meter has been separately archived on a portable computer. The detailed analysis of all collected data was carried out on the basis of own scripts and procedures designed to operate in the Matlab environment. The relevant parameters of lightning CG strokes that we have determined from the collected electric and magnetic field measurement data in the Bieszczady region can be used to increase the level of lightning protection of the ground industrial infrastructure existing in this part of Poland, such as several developing wind farms or the large water dam of the electric power plant “Solina”.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2014, 39; 55-59
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Termograficzna ocena bezpiecznej odległości materiału palnego od przewodów instalacji odgromowej
Evaluation of safe distance between lightning protection system and combustible materials using thermal imaging
Autorzy:
Chybowski, R.
Ptak, S.
Bednarek, M.
Powiązania:
https://bibliotekanauki.pl/articles/154522.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
instalacja odgromowa
materiał palny
kamera termowizyjna
badania eksperymentalne
lightning protection system
combustible material
infrared camera
experimental investigations
Opis:
W artykule przedstawiono wyniki badań bezpiecznej odległości pomiędzy materiałem palnym a instalacją odgromową. Badania przeprowadzono przy pomocy kamery termowizyjnej. Doświadczenia polegały na rozgrzaniu prądem pręta ze stali miękkiej o średnicy wymaganej w aktualnej normie i badaniu temperatury na powierzchni kartki papieru, modelującej powierzchnię materiału palnego. Arkusz umieszczano równolegle do odcinka drutu w różnych odległościach. Wyniki dowodzą, że dopuszczalne jest bezpieczne zmniejszenie odległości o co najmniej 20%.
This paper describes experimental research of a safe distance between combustible materials and a lightning protection system. The distance is required because of possible ignition of combustible materials as a result of thermal radiation emitted by the heated lightning protection wire. The euro - code which recently have became law in Poland determines the minimal distance to be at least 10 cm. Considering the phenomenon of lightning strikes, the required distance seems to be debatable. Experimental investigations were conducted on a test stand constructed in purpose to heat the steel wire using electricity. The temperature of about 800 °C was reached (Fig. 3) for both horizontal and vertical trials. A paper sheet was used to model the surface of combustible material and heated by infrared radiation emitted by a wire. The temperature of the paper sheet was measured using thermal camera (illustrated in Figure 4). The maximum temperatures of the paper sheet placed at various distances from the parallel heated wire are shown in Fig. 5. The study shows that even if a relatively high temperature is reached, it is safe to reduce the distance between a combustible material and a lightning protection system given by the mentioned euro - code.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 10, 10; 1242-1244
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości zastosowania izolowanych przewodów odprowadzających w ochronie odgromowej statków z tworzywa sztucznego
Application of lightning protection system with insulated down conductors for plastic vessels
Autorzy:
Boryń, H.
Powiązania:
https://bibliotekanauki.pl/articles/266919.pdf
Data publikacji:
2014
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
izolowane przewody odprowadzające
urządzenie piorunochronne
statki z tworzyw sztucznych
insulated down conductor
lightning protection system
plastic vessel
Opis:
Omówiono specyfikę ochrony odgromowej statków wykonanych z tworzywa sztucznego wskazując możliwość zastosowania urządzenia ochronnego z elementami piorunochronu izolowanego – izolowanymi przewodami odprowadzającymi oraz nieprzewodzącymi masztami chronionego statku. Taki układ gwarantuje istotne ograniczenie wartości prądu pioruna przepływającego przez elementy wewnętrzne statku, radykalne zmniejszenie przepięć indukcyjnych w układach wewnętrznych statku przy odpowiedniej modyfikacji obwodów wewnętrznych, jak również możliwość pracy systemu z oddzielnymi uziemieniami odgromowym i ochronno-roboczym.
The paper discusses specifics of the lightning protection system on the plastic vessels. It is indicated the using possibility of the LPS with the insulated down conductors and non-conducting masts of the protected vessel. Such a system ensures significant reduction of the lightning current value flowing through the object elements, drastic reduction of the surge inducted at the vessel internal systems, as well as the ability to work of the LPS with the separated lightning and protective grounding systems.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2014, 39; 11-15
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ochrona przed przepięciami instalacji elektroenergetycznych niskiego napięcia
Overvoltage protection for low-voltage power installations
Autorzy:
Szadkowki, Marek
Juraszek, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/1861056.pdf
Data publikacji:
2020
Wydawca:
Centrum Usług i Projektów Janusz Juraszek
Tematy:
sieć niskiego napięcia
przepięcie
ogranicznik przepięć
ochrona przepięciowa
low voltage network
surge
surge protective device
lightning protection
Źródło:
Era Energii; 2020, 1; 4-9
2658-0195
Pojawia się w:
Era Energii
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and computation of a lightning protection system in an urban 110 kV substation
Autorzy:
Taha, Mohammed Ibrahim
Li, Lin
Wang, Ping
Powiązania:
https://bibliotekanauki.pl/articles/140973.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
CDEGS software
fast Fourier transform (FFT)
IEC 62305-3
lightning protection system (LPS)
NFPA 780 level 1
Opis:
A lightning protection system (LPS) of an urban 110 kV substation is designed and analysed according to NFPA 780 and IEC 62305-3 standards. The analysis of the LPS is established on the value of risk assessment. The total area of the plant is described by one soil layer with uniform resistivity. This study aims to improve the understanding of an unexpected manner of the grounding system beneath lightning currents by clarifying the basic concepts of the lightning protection level and the new design procedure in this paper was clarified according to NFPA-780 level 1 for a lightning protection system. The program is integrated with the CDEGS software, which provides effective geometrical modeling with object and result visualization. Furthermore, module and automated fast Fourier transform (FFT) is implemented in this study to simulate electromagnetic fields in the time and frequency domains. These current values are compared to the desired protection levels within the standards. The study results show that for the improved protection of the system against lightning, the total power grid must be considered as a source of improvement for studying shielding influence and the protection levels provided inside this substation.
Źródło:
Archives of Electrical Engineering; 2020, 69, 3; 723-738
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Protection of photovoltaic systems against the impact of atmospheric discharges
Autorzy:
Kurz, D.
Powiązania:
https://bibliotekanauki.pl/articles/97628.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
photovoltaic microsystem
lightning protection system
vertical air terminal
horizontal air terminal
clearance
surge arrester
rolling sphere method
protection angle method
Opis:
In the study the attention was paid to the problem of protection of photovoltaic systems against the impact of direct and indirect atmospheric discharges (lightning). Relevant standards were quoted according to which the lightning protection system shall be executed as well as the standards applicable for equipment used in the lightning protection. Protection angle and rolling sphere methods were described in order to determine the protection zones and the height of vertical air terminals. The method of determining the minimum clearance between the elements of the PV and lightning protection systems was indicated along with the types of the used surge arresters. Various protection methods were indicated depending on the type of the system.
Źródło:
Computer Applications in Electrical Engineering; 2015, 13; 443-453
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zabezpieczenie odgromowe wybranych obiektów kolejowych
Lightning Protection of Selected Railway Facilities
Autorzy:
Dłużniewski, A.
John, Ł.
Laskowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/215339.pdf
Data publikacji:
2011
Wydawca:
Instytut Kolejnictwa
Tematy:
impulsy elektromagnetyczne
kolej
ochrona odgromowa
urządzenia elektroniczne
wyładowania atmosferyczne
zagrożenie
zwody
atmospheric discharges
electromagnetic pulses
electronic devices
lightning protection
lightning rod
rail
Opis:
W artykule omówiono problematykę projektowania ochrony odgromowej urządzeń elektronicznych znajdujących się w obiektach kolejowych, które są narażone na oddziaływanie zaburzeń elektromagnetycznych o dużej energii. Ochrona obiektu polega na wyposażeniu go w zewnętrzną instalację odgromową, która będzie obejmowała również instalacje radiowe na zewnątrz budynku oraz pełne zabezpieczenie wszystkich urządzeń elektronicznych zainstalowanych wewnątrz obiektu po stronie zasilania. Przedstawiono elementy składowe zewnętrznej instalacji odgromowej oraz zasady jej doboru. Opisano sposób projektowania zewnętrznej instalacji odgromowej uwzględniający obowiązujące wymagania normatywne.
The paper discusses the matters concerning design of lightning protection of electronic systems installed in the railway facilities exposed to high energy electromagnetic disturbances. Protection consists in providing the equipment with external lightning protection that would include also radio systems installed outside a building as well as full protection of all the electronic equipment installed inside a building on the power supply side. Components of the external lightning protection system are presented, as well as the principles of its selection.. Method for design of external lightning protection systems taking legal requirements into consideration is described.
Źródło:
Problemy Kolejnictwa; 2011, 152; 111-124
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polski komitet ochrony odgromowej sep – powstanie i działalność w okresie 1958-2016
Polish Committee of Lightning Protection SEP - establishment and operations in the period 1958-2016
Autorzy:
Flisowski, Z.
Masłowski, G.
Powiązania:
https://bibliotekanauki.pl/articles/1201652.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
ochrona odgromowa
działalność naukowo-techniczna i normalizacyjna
współpraca międzynarodowa
lightning protection
scientific-technical and standardization activity
international cooperation
Opis:
The article attempts to portray the conditions for the initiation and development process of the Polish Committee on Lightning Protection of the Polish Electrical Engineer’s Association showing the greatest achievements in all six directions of its rich activity.
W artykule starano się zobrazować warunki inicjacji i procesu rozwojowego Polskiego Komitetu Ochrony Odgromowej Stowarzyszenia Elektryków Polskich z ukazaniem ważniejszych dokonań we wszystkich sześciu kierunkach jego bogatej aktywności.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2016, 4, 112; 213-222
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected requirements for lightning protection in the light of actual standards and regulations on the example of an object to be protected
Autorzy:
Dąda, Anna
Błaut, Paweł
Miller, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2086826.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
lightning protection system
LPS
62305 standard
air-termination system
earth electrodes
protection of building objects
system odgromowy
standard 62305
elektroda uziemiająca
ochrona obiektów budowlanych
Opis:
Elements of the lightning protection system (LPS) often perform additional functions in the facility. Correct and economical design of these elements is possible with the fulfillment of specific requirements, close coordination and inter-branch cooperation. The article draws attention to important aspects of LPS design and highlights the ambiguities that may arise during this process. Firstly, the history of changes in national standardization in the field of lightning protection is approximated. Secondly, the individual components of external LPS are presented. Subsequently, the normative material requirements for earthing are compiled, depending on their function (for lightning protection and protection against electric shock in MV and LV installations). The last part of the paper is devoted to the comparison of the protective angle method and the rolling sphere method. The analysis was made on the example of a simple object for which LPS class I is required. It has been shown that despite the possibility of using both methods, they may result in different solutions. Depending on the choice of method, the difference in the arrangement of the air-termination system is indicated. Examples of generally available LPS solutions are also given, taking account of various materials and assembly technologies.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 4; e137548, 1--8
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przewody o izolacji wysokonapięciowej w ochronie odgromowej paneli fotowoltaicznych
High voltage insulated cables in lightning protection of PV panels
Autorzy:
Boryń, H.
Powiązania:
https://bibliotekanauki.pl/articles/268524.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
izolowane przewody odprowadzające
izolowane zwody
odstęp izolacyjny
ochrona odgromowa
insulated down conductor
insulated air-termination conductor
separation distance
lightning protection system
Opis:
Przedstawiono zasady ochrony odgromowej paneli fotowoltaicznych zainstalowanych na płaskim dachu budynku z wykorzystaniem przewodów o izolacji wysokonapięciowej z ekranem półprzewodzącym jako zwodów. Taki układ gwarantuje istotne ograniczenie wartości prądu pioruna przepływającego przez elementy chronione oraz radykalne zmniejszenie przepięć indukowanych w układach wewnętrznych obiektu. Przewody izolowane umożliwiają łatwe uzyskanie bezpiecznych odstępów izolacyjnych w obiekcie chronionym.
The paper discusses principles of the lightning protection of the photovoltaic panels installed on the flat roof of the building using the high voltage insulated cables with the semi-conductive screen as air terminals. This arrangement provides significant reduction of the part of lightning current flowing through the elements of the object and significant reduction of induced surge in the internal systems of the building. Insulated cables make it easy to obtain the secure separation distances in the protected object.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 45; 23-28
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uziemienia w zespołach elektrowni wiatrowych
Earthings in wind power farms
Autorzy:
Wojtas, S.
Powiązania:
https://bibliotekanauki.pl/articles/266960.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
systemy uziemień
właściwości uziemień
uziomy w elektrowniach wiatrowych
ochrona odgromowa
elektrownia wiatrowa
earthing systems
properties of earth
earth electrodes in wind power plants
wind power lightning protection
Opis:
W pracy jest omawiana problematyka budowy systemów uziemień na farmach elektrowni wiatrowych. Uziemienia poszczególnych elektrowni są wykorzystywane jako elementy systemu ochrony odgromowej oraz układu ochrony od porażeń otoczenia elektrowni wiatrowej. Farmy elektrowni są często umieszczane na gruntach o wysokiej rezystywności, co utrudnia realizację skutecznych systemów uziemień elektrowni. Trudność może napotykać zwłaszcza wykonanie uziemienia do celów ochrony od porażeń w przypadku znacznych spodziewanych prądów zwarć doziemnych po stronie sieci średniego napięcia wyprowadzającej energię z elektrowni. Uzyskana wartość rezystancji uziemienia spełniająca wymagania norm ochrony odgromowej może okazać się niewystarczająca dla skutecznej ochrony od porażeń. Przeprowadzone obliczenia symulacyjne wskazują, że w takich przypadkach pomocnymi mogą okazać się uziomy w postaci długich układów poziomych łączących poszczególne elektrownie farmy wiatrowej.
In the work is discussed constructions of earthing systems on wind turbine farms. Earthings of individual plants are used both as elements of a lightning protection system as well as the protection protection against electric shock in the vicinity of wind turbines. Power plant farms are often placed on land with high resistivity, and an implementation of power earthing systems can be difficult. The difficulty may encounter particular exercising the ground for protection against electric shock in case of significant expected earth fault currents in medium voltage network. The resulting value of the earth resistance meets the requirements of lightning protection standards may be insufficient for effective protection against electric shock. Conducted simulations indicate that in such cases earth electrodes in the form of long horizontal systems connecting each wind power farms can be useful.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 45; 67-70
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electrical properties study of fibre reinforced polymeric materials used in aircraft structures
Autorzy:
Porras, S.
Mucha, M.
Powiązania:
https://bibliotekanauki.pl/articles/241579.pdf
Data publikacji:
2018
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
composite materials
electrical conductivity
carbon fibre reinforced polymer
CFRP
glass fibre reinforced polymer
GFRP
aerospace materials
lightning strike protection
LSP
Opis:
Aircraft are exposed to lightning strikes. Lightning strike protection (LSP) devices involve additional weight of the aircraft. Therefore, multifunctional materials that allows the conductivity of electrical current and, simultaneously, holds the mechanical properties required to withstand the typical conditions for an aerospace material are widely researched. A typical resin used in aviation is an insulator, so main research is done to reduce its resistance. On the other hand, the type of reinforcement can have a large influence on the electrical conductivity in the plane of reinforcement. The aim of the article is to evaluate the effect of the type and the basis weight of reinforcement on the electrical conductivity. For this purpose, with the use of a hydraulic press, different four-layer composites based on epoxy resin were produced. Each differing is in combination of carbon, glass layers and their basis weight (from 48 kg/m2 to 245 kg/m2 ). The measuring proceedings were carried by an RMS multi meter and, more accurate, by an LCR meter with 4 selectable test frequencies. The measurements were made both along the strand fibres and at a 45-degree angle. The results made it possible to determine which reinforcement of aircraft composites should be selected at the aircraft design level to provide increased electrical conductivity along the reinforcement fibres and thus influence one of the factors affecting the protection of the aircraft against the effects of lightning
Źródło:
Journal of KONES; 2018, 25, 4; 347-353
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Klasyczne i aktywne urządzenia piorunochronne
Classic and active lightning protection devices
Autorzy:
Chrzan, K. L.
Powiązania:
https://bibliotekanauki.pl/articles/161641.pdf
Data publikacji:
2016
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
piorun
ochrona
piorunochron
strefa chroniona
piorunochron Franklina
system aktywny
badanie laboratoryjne
warunki polowe
lightning
protection
lightning arrester
protection zone
Franklin's lightning rod
active system
laboratory test
field conditions
Opis:
Obecny stan wiedzy umożliwia zbudowanie piorunochronu o znacznie większej strefie ochronnej od klasycznego piorunochronu Franklina. Jednakże taka konstrukcja byłaby bardzo droga i niepraktyczna. Dostępne na rynku głowice aktywne oferują większe strefy ochrony tylko na papierze. W warunkach polowych nikomu nie udało się udowodnić ich rzekomych właściwości. Ich postulowana strefa ochronna wyznaczana jest na podstawie pomiarów przeprowadzanych w laboratorium przy wręcz śmiesznie małym ostępie 1 m i równie zabawnym układzie ostrze – płyta (chmura) obniżonej do wysokości 2 m nad ziemią.
Current state of art allows us to design a lightning arrestor, the protection zone of which is much larger, as compared to the classic Franklin’s lightning rod. However, design as such would be very expensive and impractical. The active systems available within the market offer larger protection zones only on paper. In field conditions, nobody, so far, has been able to prove the properties of such solutions. The postulated protection zone is determined on the basis of laboratory-based measurement with ridiculously small 1 meter spacing and equally inappropriate blade-plate (cloud) system, at height of 2 meters above the ground.
Źródło:
Przegląd Budowlany; 2016, R. 87, nr 12, 12; 28-31
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-38 z 38

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies