Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "lightning" wg kryterium: Temat


Tytuł:
Nature of atmospheric discharges
Autorzy:
Aniserowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/317642.pdf
Data publikacji:
2013
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
Lightning Electromagnetic Pulse (LEMP)
lightning phenomenon
protection against lightning
Opis:
This article presents simplified description of the phenomenon of lightning, with special regard to the cloud-toground discharges, and parameters of standardized lightning electromagnetic pulses. Measures of protection against lightning are pointed out. These parameters and measures are important for proper lightning protection of telecommunication facilities.
Źródło:
Telekomunikacja i Techniki Informacyjne; 2013, 1-2; 59-67
1640-1549
1899-8933
Pojawia się w:
Telekomunikacja i Techniki Informacyjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania zagrośeń piorunowych systemów elektronicznych
Research on lightning threat in electronic systems
Autorzy:
Markowska, R.
Augustyniak, L.
Sowa, A.
Wiater, J.
Powiązania:
https://bibliotekanauki.pl/articles/267458.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ochrona odgromowa
przepięcie atmosferyczne
zagrożenie piorunowe
lightning protection
lightning overvoltages
lightning threat
Opis:
Od kilkudziesięciu lat podejmowane są próby oceny zagrożeń piorunowych urządzeń elektrycznych i elektronicznych. W prowadzonych badaniach szczególna uwaga jest zwrócona na zjawiska zachodzące podczas bezpośrednich wyładowań piorunowych w różnorodne obiekty budowlane, w których pracują systemy elektroniczne. W takich przypadkach do wyznaczania występujących zagrożeń piorunowych można zastosować kompleksową metodę analizy zachodzących zjawisk. Podstawę tej metody stanowią badania symulacyjne prowadzone w rzeczywistych obiektach. Wyniki badań terenowych wykorzystano przy tworzeniu modeli matematycznych oddziaływania prądów piorunowych na systemy elektroniczne.
The paper presents an overview on different research methods of lightning threat in electronic systems and equipment. These methods were divided in three major groups. The first group refers to measurements and registration of lightning currents and voltages generated during natural or triggered lightning strikes. Not many results of such investigations is available so far due to technical, economical and natural restrictions or limitations. Such researches are usually carried out for tall or large structures located in tropical areas. The second group of research on lightning threat consists of approximate, simulation methods in which surge current and voltage generators are used to force surge current flows in conductive elements of a building or a structure. Surge currents and voltages generated in wires and cables of electronic and electric systems using this method were recorded in various structures. Some example results are presented for large buildings, base stations of mobile communication system and high-voltage substations. Finally, the computer simulation methods of research on lightning threat are presented. The most widely known methods, namely the circuit method and the method based on electromagnetic field theory, are described in detail together with some examples of modeling of lightning strikes to the base station communication tower and the high-voltage substation.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2008, 24; 89-94
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Annual Variation Trend of Lightning Flash Activities over Sri Lanka
Autorzy:
Maduranga, U. G. Dilaj
Edirisinghe, Mahesh
Gamage, L. Vimukthi
Powiązania:
https://bibliotekanauki.pl/articles/1158876.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
LIS
Lightning flash density
Lightning protection
TRMM
Opis:
The variation of the lightning activities over Sri Lanka and surrounded costal belt (5.75ºN-10.00ºN and 79.50ºE-89.00ºE) is studied using lightning flash data of Lightning Imaging Sensor (LIS) which was launched in November 1997 for NASA’s Tropical Rainfall Measuring Mission (TRMM). The LIS data in the period of 1998 to 2014 are based on this study and there were 23838 lightning flashes over the landmass covered by Sri Lanka during considered period. The data show that average flash density has an increasing trend of 0.093 flashes km-2 year-1. The linear trend is shown in annual flash count with the fitted straight line. Although there is a slight variation between years, there is a clearly increasing trend with 24 flashes per year. There is an incremental trend in distributing of lightning activities all over the country with time. Warming trends of surface temperature and atmosphere may have a correlation with increasing trend of the lightning activities over Sri Lanka and surrounded costal belt.
Źródło:
World Scientific News; 2018, 114; 256-264
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lightning discharge density on the territory of Azerbaijan
Częstość wyładowań atmosferycznych na terytorium Azerbejdżanu
Autorzy:
Gashimov, A. M.
Khidirov, F. L.
Babayeva, A. R.
Powiązania:
https://bibliotekanauki.pl/articles/410551.pdf
Data publikacji:
2011
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
power transmission line
lightning discharge
lightning days
Opis:
Hydrometeorological information about lightning days and period of lightning days, on the supports of OVL 110, 220, 330 kV and high objects on the territory of the republic (on the radio-television tower and lighting conductors) on the basis of statistic material, a map of lightning strokes about constant lightning strokes on the territory of the republic during a year on the 1 km" surface was compiled. The drawn up map can be used in power engineering and other objects projecting.
Na podstawie statystycznych informacji meteorologicznych dotyczących liczby i częstości wyładowań atmosferycznych do elektroenergetycznych linii przesyłowych wysokiego napięcia oraz innych obiektów, takich jak maszty radiowo-telewizyjne, piorunochrony, odgromniki, została sporządzona roczna mapa gęstości wyładowań atmosferycznych na terytorium Azerbejdżanu w przeliczeniu na 1 km2. Wykreślona w ten sposób mapa może być wykorzystana w elektroenergetyce, jak i do innych celów.
Źródło:
Present Problems of Power System Control; 2011, 1; 89-96
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wyników rejestracji wyładowań atmosferycznych na projektowanie ochrony odgromowej
Influence of lightning discharge record results on lightning protection designing
Autorzy:
Wojtas, S.
Olesz, M.
Powiązania:
https://bibliotekanauki.pl/articles/266544.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyładowania atmosferyczne
ochrona odgromowa
lightning discharge
lightning protection
Opis:
W referacie przedstawiono systemy i wstępne wyniki współczesnych rejestracji parametrów wyładowań atmosfe-rycznych na obszarze Polski. Podstawą tych rozważań są wyniki uzyskane z systemu rejestracji LINET, którego jedna z anten znajduje się na terenie Politechniki Gdańskiej. Parametry wyładowań atmosferycznych otrzymane współczesnymi metodami rejestracji antenowych zostały porównane z rejestracjami przeprowadzanymi metodami klasycznymi w ubiegłym wieku. Dotyczy to zwłaszcza gęstości powierzchniowej oraz amplitudy prądu wyładowań atmosferycznych. Prezentowane wstępne wyniki rejestracji wskazują, że gęstość powierzchniowa występowania wyładowań jest większa, a amplituda prądu mniejsza od wartości oszacowanych metodami klasycznymi i wpisanych do aktów normatywnych.
The paper deals with systems as well as initiated results of lightning detection in Poland. A basic results of the presentation are gen-eral characteristics of the LINET system. One of its sensors has been installed in Gdańsk University of Technology. Lightning current parameters obtained using present methods have been compared with those obtained about a half century ago by classic methods. A prob-lems to be taken into consideration refers to both surface density of lightning strokes and their current amplitudes. Presented results indi-cate, that a surface density of lightnings seems to be higher than that obtained by classic methods and their amplitudes seem to be lower in comparison to those evaluated in previous century and introduced to standard regulations. Lightning flash localization and detection results can have an influence on lightning protection system design methods in future.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2010, 27; 125-130
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sniženie vliâniâ grozovyh proâvlenij na obʺektah agropromyšlennogo kompleksa putem soveršenstvovaniâ harakteristik ih molniezaŝity
Reduction of Storm Consequences on the Agricultural Sector by Improvement to Features of the Protection System Against Lightning Strikes
Redukcja wpływu zjawisk burzowych w obiektach sektora przemysłowo-rolnego poprzez udoskonalenie właściwości systemów ochrony odgromowej
Autorzy:
Skripko, A. N.
Misun, L. V.
Powiązania:
https://bibliotekanauki.pl/articles/373010.pdf
Data publikacji:
2015
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
lightning
lightning protection
lightning conductor
fire
agricultural property
piorun
ochrona odgromowa
piorunochron
pożar
obiekt sektora przemysłowo-rolnego
Opis:
Aim: Identification of solutions, which increase the effectiveness of protection against direct lightning strikes, by taking account of past experience associated with agricultural property, which was exposed to the impact of storms. Introduction: Each year, in the Republic of Belarus, many fires are caused by lightning strikes. As a result buildings used by the public and for industrial purposes are exposed to damage. These include storage facilities for flax and fodder. Additionally, animals and birds die. During the years 2001-2013 there were 46 fires in Belarus, which affected buildings and items from the agro-industrial sector, of which 43 were as the result of direct lightning strikes and 3 related to secondary causes. The biggest proportion of fires were caused by direct lightning strikes. The basic approach used to protect buildings from lightning strikes is by utilising lightning conductors [1–2]. During a period of use, protective properties of lightning conductors may undergo a change, caused by the influence of external factors. Such a change may reduce the size of a protected area with a consequential impact on the safety of a building or other item in the vicinity at the moment of a lightning strike. Methods: In order to examine the impact on the safety of buildings and other property, caused by changes to properties of lightning conductors, research was performed with the aid of data analysis, of fires caused by lightning strikes and by observation of changes to properties of lightning conductors. Based on passive experiments a mathematical model was developed for use in forecasting, to determine the potential for property to avoid the consequences of fires caused by storms and a model, which could describe the effective operation of a lightning conductor. A technical solution was proposed for the construction of a lightning conductor, which would protect property from a direct lightning strike. A study of lightning conductors was performed, including the registration of changes to their protection properties. Conclusions: The choice of optimum technical data, for a protection device against direct lightning strikes, was justified. This data provided a basis for the development of an experimental lightning conductor model. Furthermore, research identified limit values applicable to changes in the properties of lightning conductors, with the aim of modifying methods of describing the protection range of lightning conductors and introduction of appropriate amendments to fire prevention regulations and norms in Belarus. Implications for practice: The development of a technical solution, to deal with protection against lightning strikes, particularly for business properties, provides a level of stable and lasting security and eliminates the problem associated with a reduction in the protective range of lightning conductors.
Cel: Wskazanie rozwiązań zwiększających efektywność środków ochrony przeciw bezpośredniemu uderzeniu pioruna z uwzględnieniem negatywnych doświadczeń z eksploatacji obiektów gospodarczych związanych z oddziaływaniem na nie zjawisk burzowych. Wprowadzenie: W Republice Białorusi co roku dochodzi do pożarów spowodowanych uderzeniem piorunów. W wyniku tych pożarów zniszczeniu ulegają budynki produkcyjne oraz budynki i obiekty użyteczności publicznej, magazyny paszy objętościowej i lnu, giną zwierzęta, w tym ptaki. W latach 2001-2013 na terytorium Białorusi doszło do 46 pożarów w budynkach i obiektach sektora przemysłowo- rolnego, 43 z nich wskutek bezpośredniego uderzenia pioruna, a 3 od jego wtórnego oddziaływania. Największy odsetek stanowią pożary powstałe wskutek bezpośredniego uderzenia pioruna. Podstawowymi metodami ochrony obiektów od tego rodzaju zagrożenia są piorunochrony [1–2]. W czasie eksploatacji piorunochronów, z uwagi na oddziaływanie czynników zewnętrznych, ich właściwości ochronne mogą ulec zmianom. Odchylenia piorunochronów mogą powodować zawężenie strefy objętej ochroną, wpływając w ten sposób na bezpieczeństwo budynku lub obiektu w momencie uderzenia piorunu. Metody: Aby zbadać wpływ zmian właściwości piorunochronów na bezpieczeństwo budynków i obiektów, przeprowadzone zostały badania, których podstawą była analiza danych statystycznych na temat pożarów powstałych wskutek uderzenia pioruna oraz obserwacje zmian właściwości piorunochronów. Na podstawie przeprowadzonych biernych eksperymentów opracowany został model matematyczny do prognozowania odporności budynków lub obiektów na pożary powstałe w wyniku zjawisk burzowych oraz model matematyczny skutecznej pracy piorunochronu. Zaproponowano rozwiązanie techniczne budowy piorunochronu, który zapewniłby ochronę obiektu przed bezpośrednim uderzeniem piorunu. Przeprowadzono obserwacje piorunochronu, w tym rejestrację jego odchyleń od osi ochrony. Wyniki: Uzasadniono dobór optymalnych parametrów technicznych dla urządzenia zabezpieczającego przed bezpośrednim uderzeniem pioruna, na podstawie których opracowano model eksperymentalny piorunochronu. Określono wartości graniczne dla zmian właściwości piorunochronu w celu opracowania zmian metodologii określania zasięgu ochrony piorunochronów, wprowadzenia odpowiednich poprawek w wymaganiach norm przeciwpożarowych i standaryzacji na Białorusi. Znaczenie dla praktyki: Stosowanie w obiektach gospodarczych: opracowanie rozwiązania technicznego w zakresie ochrony odgromowej, zapewniającego stabilną i trwałą ochronę, wyeliminowanie problemu zmniejszenia zasięgu ochrony piorunochronu.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2015, 2; 113-124
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Budowa i działanie systemu detekcji i lokalizacji wyładowań atmosferycznych Blitzortung
Construction and operation lightning detection and locations system Blitzortung
Autorzy:
Gamracki, M.
Powiązania:
https://bibliotekanauki.pl/articles/194168.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
wyładowanie atmosferyczne
detekcja wyładowań atmosferycznych
lokalizacja wyładowań atmosferycznych
pole elektromagnetyczne
lightning
lightning detection
location of lightning
electromagnetic field
Opis:
W pracy opisano budowę i podstawy funkcjonowania systemu detekcji i lokalizacji wyładowań atmosferycznych Blitzortung. Początkowe rozdziały opisują podstawy dotyczące działania tego typu systemów, zakresy częstotliwości stosowane przy detekcji wyładowań oraz najczęściej stosowane metody detekcji i lokalizacji wykorzystywane w tego typu systemach. Wspomniano także o innych komercyjnych systemach detekcji i lokalizacji wyładowań pracujących na świecie. Opisano zalety i wady systemów detekcji pracujących na niskich i na wysokich częstotliwościach. Szerzej opisano funkcjonowanie systemu Blitzortung a także elementy wchodzące w skład każdej stacji detekcji, rodzaje obecnie działających stacji (wersje urządzeń o nazwach RED i BLUE), ich możliwości i funkcjonalność. Opisano rodzaje i budowę anten używanych do detekcji pola elektromagnetycznego przez stacje systemu Blitzortung. Na przykładzie kontrolera w wersji RED pokazano działanie stacji odbierającej sygnały z anten i jego możliwości w zakresie filtracji sygnałów nie pochodzących od wyładowania. Pokazano rozmieszczenie stacji detekcji na ternie centralnej Europy i USA. Opisano wybrane inne możliwości jakie daje system Blitzortung i porównano jego możliwości z systemami profesjonalnymi. Pokazano przykładowe rejestracje systemu w postaci wycinka mapy z zaznaczonymi miejscami wyładowań a także mapę gęstości wszystkich wyładowań zarejestrowanych przez system w roku 2015 na terenie Polski oraz przykładowe zarejestrowane charakterystyki czasowe wyładowania.
This paper describes the structure and basis of the Blitzortung system for detection and location of lightning. The initial chapters describe the basis for the operation of such systems, frequency bands used for the detection of lightning and the most frequently used method for the detection and location used in such systems. Also mentioned other commercial systems, lightning detection and location of operating in the world. Paper show the advantages and disadvantages of detection systems operating at low and high frequencies. Described in more detail the Blitzortung system and the elements included in each detection station, the types of currently operating station (device versions named RED and BLUE), their features and functionality. Described the types and construction of antennas used to detect the magnetic and electric fields by the stations of the Blitzortung system. Shows the position of detection stations on the area of central Europe and the USA. In the next part the paper describes some of the possibilities offered by the Blitzortung system. In example the controller version RED shows the effect of the station receiving signals from the antenna and its possibilities for filtering signals which not coming from the discharge. Also describes some other features offered by the Blitzortung system and compared it with professional systems. Show some example from registration in the form of a map section with marked locations of discharge, map of density all discharges recorded by the system in 2015 on Poland area and sample time characteristics of discharge.
Źródło:
Zeszyty Naukowe Politechniki Rzeszowskiej. Elektrotechnika; 2017, z. 36 [296], nr 1, 1; 27-40
0209-2662
2300-6358
Pojawia się w:
Zeszyty Naukowe Politechniki Rzeszowskiej. Elektrotechnika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza sygnatur pola elektrycznego wyładowań atmosferycznych w rejonie Bieszczad na podstawie kompleksowych pomiarów impulsów fali elektromagnetycznej w paśmie częstotliwości od 0 do 3 mhz wykonanych w Akademickim Ośrodku Szybowcowym Politechniki Rzeszowskiej i Politechniki Warszawskiej w Bezmiechowej w maju 2014 r.
Analysis of lightning discharge electric field signatures obtained from the comprehensive measurements of associated electromagnetic pulse radiation in the frequency range from 0 to 3 mhz, carried out at the academic gilder center of the Rzeszów and Warsaw Technical Universities at Bezmiechowa in may 2014
Autorzy:
Sobolewski, K.
Karnas, G.
Barański, P.
Masłowski, G.
Powiązania:
https://bibliotekanauki.pl/articles/266313.pdf
Data publikacji:
2014
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyładowania atmosferyczne
detekcja i lokalizacja wyładowań piorunowych
mechanizm wyładowania piorunowego
ochrona odgromowa
lightning flash
cloud-to-ground lightning stroke
lightning detection and location network
lightning protection
Opis:
W niniejszym artykule przedstawiono kompleksowe pomiary piorunowego pola elektromagnetycznego z równoczesnym wykorzystaniem kilku anten. Przedmiot badań dotyczył incydentu burzowego z dnia 20 maja 2014 r. zarejestrowanego w AOS PRz i PW1 w Bezmiechowej Górnej. Zestaw pomiarowy składał się z dwóch anten pola „szybkiego” (0,.5 Hz - 3 MHz) oraz jednej anteny pola „wolnego” – młynka (0 Hz – 10 Hz). Anteny pola szybkiego pozwoliły na obserwację składowej radiacyjnej, porównanie danych z dwóch identycznych czujników pomiarowych i weryfikację pracy układu wyzwalającego . Dodatkowo na wieży pomiarowej zainstalowano atestowany miernik pola EM Maschek ESM-100 o zakresie 5 Hz – 400 kHz. Umożliwiło to zaobserwowanie dobowych zmian trzech składowych wektora oraz modułu pól elektrycznego i magnetycznego. W artykule przeprowadzono analizę pomiarów z wykorzystaniem programu Matlab, generującego wykresy pola elektromagnetycznego w funkcji czasu.
We have presented in this paper some results obtained from the amplitude-frequency analysis of electric field signatures associated with cloud-to-ground (CG) and intra-cloud (IC) lightning discharges that were recorded in the Bieszczady region during the one-week field campaign. The apparatus set used in this campaign consisted of three electric field sensors, i.e. the fast-track unit that was operated in the frequency range from 0.5 Hz to 3 MHz, the slow-track unit that was operated in the frequency range from 20 Hz to 100 kHz and the field mill with rotating dipole operating in the frequency range from 0 Hz to 10 Hz. Such complete measuring devices have allowed for recoding both the electrostatic, intermediate and radiation components of the electric field changes associated with close and distant lightning flash incidents. Additionally, we have used the certified Maschek meter (type ESM-100) for simultaneous recordings of three vector components and the module of electric and magnetic fields connected with the electromagnetic interferences in the frequency range from 5 Hz to 400 kHz that have occurred during observed thunderstorms. The data stream obtained from the Maschek meter has been separately archived on a portable computer. The detailed analysis of all collected data was carried out on the basis of own scripts and procedures designed to operate in the Matlab environment. The relevant parameters of lightning CG strokes that we have determined from the collected electric and magnetic field measurement data in the Bieszczady region can be used to increase the level of lightning protection of the ground industrial infrastructure existing in this part of Poland, such as several developing wind farms or the large water dam of the electric power plant “Solina”.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2014, 39; 55-59
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zmian zasad oceny zagrożenia piorunowego na potrzebę stosowania ochrony odgromowej i jej kategorię
Influence of changes of lightning threat assessment principles on the need of lightning protection and its category
Autorzy:
Maksimowicz, T.
Zielenkiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/266629.pdf
Data publikacji:
2014
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ochrona odgromowa
zagrożenie piorunowe
analiza ryzyka
lightning protection
lightning threat
risk assessment
Opis:
Na przestrzeni ostatnich dekad wraz ze zmianami aktów normalizacyjnych w zakresie ochrony odgromowej transformacji ulegały także procedury, według których podejmowana jest decyzja o potrzebie stosowania instalacji odgromowej obiektów budowlanych. W artykule przedstawiono przegląd praktyk oceny zagrożenia piorunowego w normach dotyczących ochrony odgromowej poczynając od normy PN-E05003:1986 i kończąc na aktualnej drugiej edycji norm PN-EN 62305-2:2012, dokonano porównania poszczególnych toków postępowania ze wskazaniem ich wad i zalet, a także zamieszczono przykłady wyników oceny potrzeby stosowania i doboru kategorii instalacji odgromowej według różnych norm dla typowych obiektów budowlanych. Przedstawiona analiza obliczeń zagrożenia piorunowego pokazuje, iż różne procedury oceny ryzyka kolejnych wersji omawianych norm dają odmienne wyniki.
Principles of lightning threat assessment for buildings have changed seriously with revision of normative documents regarding lightning protection in Poland over the last few decades. This paper presents review of principles according to lightning protection standards from PN-E-05003:1986 to PN-EN 62305-2:2012. All the procedure has been compared with indication of advantages and disadvantages of each of them. Examples of results of lightning threat assessment for typical buildings like country house, office building, hospital, industrial hall and radio and television broadcasting centre are presented and compared. According to different standards different results can be obtained.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2014, 39; 29-36
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ochrona odgromowa obiektów budowlanych i ich wyposażenia
Lightning protection of buildings and their equipment
Autorzy:
Flisowski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/317670.pdf
Data publikacji:
2013
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
ochrona odgromowa
piorunowa wrażliwość obiektów
uwarunkowania prawne ochrony odgromowej
lightning protection
lightning vulnerability to building objects
legal conditions for lightning protection
Opis:
Celem artykułu jest zwrócenie uwagi na specyficzne zagadnienia związane z ochroną obiektów budowlanych i ich wyposażenia przed oddziaływaniem wyładowań piorunowych. Poruszono też kwestie związane z normalizacją w ochronie odgromowej, istniejącym chaosem prawnym, nieodpowiednią reakcją urzędów państwowych, brakiem profesjonalizmu oraz ignorancją instalatorów i inspektorów nadzoru. Omówiono także zagadnienia związane z wrażliwością obiektów i wyposażenia na wyładowania piorunowe, wybiórczością piorunów przez zwody oraz bezpiecznym odprowadzaniem prądu wyładowania do ziemi.
An article draws attention to specific issues related to the protection of buildings and their equipment from the lightning strikes. Issues related to standardization in lightning protection, the existing legal chaos, inadequate response to the civil service, lack of professionalism and ignorance installers and inspectors are addressed. The paper also discussed issues related to sensitive facilities and equipment to lightning strikes, lightning selectivity by rods and the safe discharge of static electricity to the ground.
Źródło:
Telekomunikacja i Techniki Informacyjne; 2013, 1-2; 68-86
1640-1549
1899-8933
Pojawia się w:
Telekomunikacja i Techniki Informacyjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Szporowskie korzenie Katedry Wysokich Napięć i Aparatów Elektrycznych Politechniki Gdańskiej
Szpors roots of the school of high voltages and electrical apparatus of Gdansk University of Technology
Autorzy:
Wolny, A.
Powiązania:
https://bibliotekanauki.pl/articles/267439.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
technika wysokich napięć
ochrona odgromowa
piorunochrony
high voltage technique
lightning protection
lightning arrester
Opis:
Przedstawiono zwięzłą historię katedry utworzonej przez prof. S. Szpora na Politechnice Gdańskiej, rozwój zespołu badawczego i najważniejsze osiągnięcia. Pokazano aktualny stan katedry, która wyrosła na fundamentach zbudowanych przez Profesora i tematykę badawczą realizowaną przez pokolenie, czerpiące swą wiedzę od Jego uczniów.
A concise high voltage school history created by prof. Szpor at the Gdańsk University of Technology, as well as its research team development and achievements have been presented. Present activity of the school grown on the foundation layed down by the Professor, and the problems investigated by the generation tought by His disciples has been described.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2008, 24; 1-6
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synoptyczne uwarunkowania burz w październiku 2020 roku w Polsce
Synoptic conditioning of thunderstorms in October 2020 in Poland
Autorzy:
Wardowski, Daniel
Powiązania:
https://bibliotekanauki.pl/articles/43347564.pdf
Data publikacji:
2020-12-15
Wydawca:
Poznańskie Towarzystwo Przyjaciół Nauk
Tematy:
thunderstorm
October
lightning
synoptic conditions
Polska
Opis:
The aim of this study is to characterize the occurrence of severe thunderstorms and determine their synoptic conditioning in October 2020 in Poland. In the study, into account were taken three days, i.e. 4, 5 and 10 October, which showed the most intense storm activity. The study considers the number and area of lightning discharges over Poland, the synoptic conditions prevailing in Europe, as well as basic thermodynamic and kinematic indices. The storms in October 2020 were exceptional in comparison to the previous years. They were associated with the migration of cool atmospheric fronts across Poland and the exchange of old polar-marine air masses with polar-marine air masses, which generated the specific thermodynamics and, specifically, the kinetic conditions for the development of thunderstorm cells.
Źródło:
Badania Fizjograficzne Seria A - Geografia Fizyczna; 2020, 11 (71); 95-121
2081-6014
Pojawia się w:
Badania Fizjograficzne Seria A - Geografia Fizyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lightning protection for power transformers of Aqaba Thermal Power Station
Autorzy:
Shehab, Wael Fawzi Abu
Ali, Shehab Abdulwadood
Alsharari, Mohammad Ibrahim
Powiązania:
https://bibliotekanauki.pl/articles/141206.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
basic insulation level BIL
EMTP-ATP program
lightning
lightning arrester LA
metal oxide varistor MOV
Opis:
In this paper, a study of the lightning phenomenon and its harmful effect on Aqaba Thermal Power Station (ATPS), located in the south-western border of Jordan, is presented using the Electromagnetic Transients Program – Alternative Transients Program (EMTPATP). This study has been arisen due to an installation need of appropriate lightning arresters (LAs) for the 15/410 kV step-up transformers of the ATPS to eliminate the destructive effect of lightning. The simulation is carried out for two cases, once without using LAs and once more with using them. Two scenarios are applied for each of these cases, once when lightning strikes the primary side of the transformer and once more when it strikes the secondary side. The results obtained by the simulation indicate the necessity of LAs installation. This study, with using the EMTP-ATP program, is done for the first time with additional details that help researchers, designers, and engineers to get a broad overview of the ATPS in order to protect it against lightning.
Źródło:
Archives of Electrical Engineering; 2020, 69, 3; 645-660
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane modele matematyczne udaru piorunowego
The selected mathematicals descriptions of lighting impulse
Autorzy:
Walczak, J.
Pacholski, K.
Kowalczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/269198.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
udar piorunowy
udar znormalizowany
prąd udaru piorunowego
lightning impulse
standardized impulse
current of lightning impulse
Opis:
Zastosowanie modelu uproszczonego udaru piorunowego i określenie jego znormalizowanych parametrów pozwala na standaryzację oraz na wykorzystanie takiego modelu w badaniach związanych z ochroną odgromową. Można, zgodnie z przyjętym poziomem prawdopodobieństwa, założyć wartości maksymalne wybranych parametrów udaru piorunowego. Wartości te podlegają na ogół rozkładowi statystycznemu logarytmonormalnemu. Znormalizowane rodzaje i parametry dla typowych udarów piorunowych pozwoliły na stworzenie znacznie prostszych i łatwiejszych do wykorzystania w dalszych analizach modeli matematycznych. Najczęściej spotykany model prezentowany w literaturze to model opisany funkcją dwuwykładniczą i model zobrazowany funkcją Heidlera.
The use of the simplified model of the lightning impulse and specification of its standardized parameters allows for standardization and the use of such a model in researches related to lightning protection. According to the adopted level of probability we can assume the maximum values of selected parameters of the lightning impulse. Generally these values are the subject to a statistical normal logarithm distribution. Standardized types and parameters for typical lightning impulses enabled the creation of much simpler and easier to use in further analysis of mathematical models. The most common models presented in literature are the model described with the double-exponential function and the model illustrated with Heidler function.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 55; 77-80
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulations of Fast Transients in typical 25 kV a.c. railway power supply system
Symulacje stanów nieustalonych w typowym 25 kV a.c.układzie zasilania trakcji
Autorzy:
Chmielewski, T.
Dziadkowiec, A.
Powiązania:
https://bibliotekanauki.pl/articles/266311.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
railway
lightning
PSCAD
trakcja
przepięcia piorunowe
Opis:
Railway power lines as any other outdoor overhead conductors are exposed to lightning strokes. Overvoltages generated by a lightning surge may severely decrease the overall system reliability due to possible damages of powering and signalling equipment. Hence an appropriate design of lightning protection is crucial. This paper presents computer simulations of lightning phenomenon (Fast Transients) in a typical railway catenary system conducted in PSCAD software. Detailed numerical model consisted of cables, overhead catenary lines, surge arresters, transformers and rails. A few modelling approaches were used and compared. The outcome of such analysis can be helpful in determining possible overvoltages in railway system along with a proposal of ratings and locations of additional surge arresters’ installation.
Treść artykułu skupia się na symulacyjnych badaniach przepięć piorunowych w sieci zasilania trakcji elektrycznej. W oparciu o model typowego systemu 25 kV a.c., przeprowadzono porównanie odpowiedzi układu w przypadku zmiany podejścia do modelowania elementów takich jak napowietrzna sieć trakcyjna, czy też szyny.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 36; 43-46
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies