Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "laser interferometry" wg kryterium: Temat


Wyświetlanie 1-9 z 9
Tytuł:
Research on deformations of laser-welded joint of a steel sandwich structure model
Autorzy:
Boroński, D.
Kozak, J.
Powiązania:
https://bibliotekanauki.pl/articles/259411.pdf
Data publikacji:
2004
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
laser welding
laboratorytests of structural elements
laser interferometry
Opis:
Problems of the behaviour of all-steel, laser welded sandwich panels in plate-to-web contact zone are presented. Results of laboratory tests on determination of deformation field around laser weld under bending load - obtained by laser interferometry technique - are shown. Analysis of strain field distribution is included and same conclusions related to modeling of behaviour of such connection are drawn.
Źródło:
Polish Maritime Research; 2004, 2; 3-8
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of ciprofloxacin and gentamicin diffusion in Proteus mirabilis O18 biofilm by laser interferometry method
Autorzy:
Arabski, Michał
Wąsik, Sławomir
Zych, Magdalena
Łakomiec, Wioletta
Kaca, Wiesław
Powiązania:
https://bibliotekanauki.pl/articles/1039471.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
laser interferometry
Proteus sp.
biofilm
ciprofloxacin
gentamicin
Opis:
Laser interferometry is a measurement technique used in physical sciences, with a potential for new applications in microbiology. Our previously studies, focused on the quantitative analysis of antibiotics diffusion through membranes or their releasing from gel structure, indicate that this method might be useful in analysis of substances diffusion across the bacterial biofilms. As antibiotic - biofilm interaction model, we tested above method for determination of ciprofloxacin or gentamicin diffusion through Proteus mirabilis O18 biofilm. Laser interferometry analysis of antibiotics diffusion showed that the amount of ciprofloxacin transported through mature biofilm is 1.9 times higher than gentamicin. It was correlated with lower level of gentamicin in compare to the level of ciprofloxacin in biofilm, which amounts were predicted in biofilm during diffusion process by laser interferometry method. We suggest that the analysis of antibiotic diffusion in biofilm might by helpful in evaluation of effectiveness of antibacterial agents.
Źródło:
Acta Biochimica Polonica; 2013, 60, 4; 707-711
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tests of local strains in steel laser - welded sandwich structure
Autorzy:
Boroński, D.
Szala, J.
Powiązania:
https://bibliotekanauki.pl/articles/260500.pdf
Data publikacji:
2006
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
fatigue
laser welding
local strain distributions
laser grating interferometry
steel panel structures
Opis:
This paper presents results of the tests of local strains in laser weld zone of steel sandwich structure, performed at the Department of Machine Design, University of Technology and Agriculture, Bydgoszcz, in cooperation with the Department of Ship and Offshore Structures Technology, Gdańsk University of Technology, within the frame of ASPIS EUREKA E!3074 project titled : „Application of steel sandwich panels into ship structural design”. Specific features of the tested structure make that in the weld zone both geometrical and structural notch appears simultaneously. The presented results may be helpful in further developing sandwich structures themselves and laser welding technique as well as their design methods as far as avoiding fatigue cracks is concerned.
Źródło:
Polish Maritime Research; 2006, S 1; 31-36
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ sposobu wyznaczenia poprawki kalibracyjnej na określane przewyższenie
The influence of the method of determination of a calibrating correction of measured high difference
Autorzy:
Frukacz, M.
Powiązania:
https://bibliotekanauki.pl/articles/262452.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
wzorcowanie
łaty niwelacyjne
interferometria laserowa
poprawka kalibracyjna
niwelacja precyzyjna
calibration
levelling rods
laser interferometry
calibrating correction
precise levelling
Opis:
W pracy zaprezentowano sposoby obliczania poprawki kalibracyjnej do wyników niwelacji precyzyjnej. Zaprojektowano i przeprowadzono eksperyment statystyczny, który polegał na losowym generowaniu wyników niwelacji oraz określaniu dla nich wartości poprawek liczonych różnymi sposobami. Zaobserwowano, że zróżnicowane sposoby liczenia poprawki kalibracyjnej mogą powodować skażenie wyników niwelacji błędami o charakterze systematycznym. Dla porównania policzono dla danych z eksperymentu wartości innych poprawek wprowadzanych do wyników niwelacji precyzyjnej
In this paper, the author presents the methods of determination of a calibrating correction of the precise leveling results. The purpose of the statistical experiment which was carried out, was to generate randomly the results of levelling as well as determine the calibrating corrections in four ways. It was observed that different ways of calculating this correction may cause the occurrence of systematical errors. The values of other corrections, for example correction for refraction, in this experiment was calculated for comparison
Źródło:
Geodezja / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie; 2005, 11, 1/1; 115-125
1234-6608
Pojawia się w:
Geodezja / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania zależności temperaturowych rozszerzalności cieplnej i ciepła właściwego stopu glinu PA-6
Investigation of thermal expansivity and heat capacity temperature dependence of PA-6 aluminium alloy
Autorzy:
Panas, A. J.
Panas, J.
Polakowski, H.
Piątkowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/210654.pdf
Data publikacji:
2011
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
właściwości cieplno-fizyczne
ciepło właściwe
rozszerzalność cieplna
mikrokalorymetria skaningowa (DSC)
dylatometria interferencyjna
thermophysical properties
thermal expansivity
heat capacity
laser interferometry
DSC technique
PA6 aluminium alloy
Opis:
W pracy przedstawiono wyniki badań dwóch komplementarnych właściwości cieplnych: ciepła właściwego i rozszerzalności cieplnej liniowej stopu glinu PA6. Ciepło właściwe określono metodą względną za pomocą mikrokalorymetru skaningowego (DSC) w zakresie od -20 do 230°C. Rozszerzalność cieplną określono metodą absolutną, wykorzystując stanowisko do badań zmodyfikowaną metodą interferencyjną. Pomiary tej właściwości przeprowadzono w zakresie od 20°C do ok. 400°C. W obydwu przypadkach zachowano dużą rozdzielczość termiczną badań, co pozwoliło na określenie reprezentatywnych charakterystyk aproksymacyjnych ciepła właściwego i rozszerzalności cieplnej liniowej. Wyniki badań dylatometrycznych przeliczono również do wartości wydłużenia względnego. W dodatkowych badaniach wyznaczono gęstość badanego materiału metodą wypornościową.
Results of experimental investigation of a temperature dependence of two basic thermophysical properties, i.e., thermal expansivity (coefficient of thermal linear expansion) and heat capacity of PA-6 aluminium alloy have been presented. The heat capacity was measured using a Perkin-Elmer Pyris 1 DSC apparatus within the range from -20°C to 230°C. A relative three-curve method of microcalorimetric data processing has been applied. The CLTE was determined using the laser interferometry dilatometer in the course of absolute measurements. These investigations were performed within the range from 20°C to 400°C. On the basis of the high temperature resolution experimental data, the representative least square approximates for heat capacity and CLTE were calculated. The results of CLTE measurements were also recalculated to the linear expansion (LE) values. The experimental investigations were complemented with buoyancy measurements of the tested material density.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2011, 60, 4; 103-117
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental and theoretical investigations of crater formation in an aluminium target in a PALS experiment
Autorzy:
Borodziuk, S.
Doskach, I.
Gus'kov, S.
Jungwirth, K.
Kálal, M.
Kasperczuk, A.
Kralikova, B.
Krousky, E.
Limpouch, J.
Masek, K.
Pfeifer, M.
Pisarczyk, P.
Pisarczyk, T.
Rohlena, K.
Rozanov, V.
Skala, J.
Ullschmied, J.
Powiązania:
https://bibliotekanauki.pl/articles/147967.pdf
Data publikacji:
2004
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
laser-produced plasma
crater
absorption of laser radiation
resonance mechanism
inverse bremsstrahlung
interferometry
fast electrons
Opis:
Experimental and theoretical results of investigations of the iodine laser - Al solid target interactions on the PALS (Prague Asterix Laser System) facility are presented. The experimental investigations of laser interaction with massive Al targets devoted to shock wave propagation in solids and crater formation physics are presented. Experiments were performed with the use of high intensity laser pulses (1013 15 W/cm2) for two laser wavelengths (0.438 mi m and 1.315 mi m) and four laser beam radii (from 35 mi m up to 600 ěm). The crater dimensions were measured using optical microscopy and a wax-replica technique. Plasma expansion out of the target was measured via three-frame interferometry. Theoretical model of the postpulse crater formation by the shock wave propagating and decaying in solids after the end of the laser pulse is presented and applied for the explanation of the results obtained in experiments.
Źródło:
Nukleonika; 2004, 49, 1; 7-14
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Generation of two identical ns laser pulses at single μs spacing by switching output mirror transmission
Autorzy:
Skórczakowski, Marek
Żendzian, Waldemar
Jankiewicz, Zdzisław
Powiązania:
https://bibliotekanauki.pl/articles/220917.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
double pulse Q-switched laser
pulsed holographic interferometry
transmission losses switching
diode pumped Q-switched laser
Opis:
Generation of two identical ns laser pulses spaced by a single μs time interval by means of sequential switching of the output mirror transmittance in a diode-pumped Nd:YAG laser is reported, to our knowledge, for the first time. The theoretical study of the process of transmission losses switching is developed. This analysis confirms the possibility of generation of two identical Q-switched laser pulses with 100% efficiency with respect to the referenced single pulse energy. The detailed characterization of the laser in free-running, single and double Q-switching regimes is presented. The laser can be applied in different branches of metrology as PIV, LIBS or holographic interferometry.
Źródło:
Metrology and Measurement Systems; 2020, 27, 3; 513-530
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Generation of Large-area Arrays of Aperiodic Functional Micro/nano Structures Using Phase Shift Interferometry
Autorzy:
Pearly Princess, J.
Alfred Kirubaraj, A.
Christina Sophia, S.
Senith, S.
Jino Ramson, S. R.
Powiązania:
https://bibliotekanauki.pl/articles/2055275.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
laser interference lithography
LIL
pattern structures
periodic patterns
aperiodic patterns
phase shift interferometry
PSI
Opis:
Phase shift interferometry (PSI) derived from interference technique as greater surface characterization technique based on the interference information recorded during a controlled phase shift. This research shows the development of micro/nano structures using phase shift interferometry. (PSI) is the process of developing the complex pattern structure using variable phase angle between two or more beams aligned to obtain functional aperiodic arrays. We have designed and modelled the PSI and simulated through MATLAB in 2D and 3D pattern structures. The PSI was performed in two process analysis. First, without PSI referring normal interference technique. Second, with PSI referring position of laser beams in quadrant-based alignment. The obtained results show the minimum feature structure was measured as 12 nm. This feature size developed under phase shift interferometry (PSI) produces minimum feature size compared to the existing interferometry technique. This study gives the promising increased fabrication area could develop large area arrays structures.
Źródło:
International Journal of Electronics and Telecommunications; 2022, 68, 1; 91--96
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interferometr laserowy GBI300 do pomiarów materialnych wzorców długości - płytek wzorcowych
GBI300 laser interferometer for measuring of material standards of length - gauge blocks
Autorzy:
Szumski, R.
Powiązania:
https://bibliotekanauki.pl/articles/151697.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
płytki wzorcowe
interferometr laserowy GBI300
metoda interferencyjna
niepewność
walidacja
gauge blocks
laser interferometer GBI300
interferometry
uncertainty
validation
Opis:
Laboratorium Długości Zakładu Długości i Kąta GUM posiada najdokładniejszy w kraju, automatyczny interferometr laserowy do wzorcowania płytek wzorcowych o zakresie pomiarowym 305 mm. Interferometr GBI300 służy do wzorcowania płytek wzorcowych o przekroju prostokątnym, kwadratowym i okrągłym, służących następnie jako wzorce odniesienia przy pomiarach metodą porównawczą. Umożliwia on wyznaczenie takich parametrów płytek wzorcowych, jak odchylenie długości środkowej od długości nominalnej, zmienność długości oraz odchylenie od płaskości powierzchni pomiarowych. GBI300 jest zbudowany na bazie klasycznego interferometru "Twymana-Greena" z wykorzystaniem wysokiej jakości laserów stabilizowanych częstotliwościowo i oprzyrządowania sterowanego komputerowo. Układ pomiarowy działa w oparciu o metodę kroku fazowego (ang. phase stepping) wykorzystując techniki numerycznego przetwarzania obrazu do analizowania interferogramów otrzymanych z kamery CCD. źródem wzorcowych długości fal światła są dwa stabilizowane częstotliwościowo lasery helowo neonowe o długościach fal promieniowania: 633 nm (czerwony) i 543 nm (zielony). Dzięki zastosowaniu napędu do stolika pomiarowego możliwe jest wykonanie pomiarów do dwunastu płytek wzorcowych w krótkim okresie czasu, co znacznie zwiększa wydajność i pozwala na wykonanie większej ilości pomiarów każdej płytki. Stanowisko pomiarowe umieszczone jest w klimatyzowanym pomieszczeniu, zapewniającym stabilizację temperatury wewnątrz komory w zakresie (19,9 ÷ 20,1) °C. Komora pomiarowa umieszczona jest na stole z układem wibroizolacyjnym i połączona z jednostką sterująco-pomiarową, wyposażoną w urządzenia i komputer, sterujące pracą całego stanowiska oraz przyrządy pomiarowe do monitorowania warunków środowiskowych. Walidacja stanowiska pomiarowego i szacowanie niepewności pomiaru przeprowadzone zostały na podstawie badań przeprowadzonych w laboratorium oraz przy wykorzystaniu płytek wzorcowych posiadających świadectwo wzorcowania z National Physical Laboratory - Anglia.
Length Laboratory of Length and Angle Division of GUM uses the most accurate in Poland automatic laser interferometer for calibration of gauge blocks, with measurement range of 305 mm. The GBI300 interferometer can be used for calibration of both rectangular or square (Hoke) gauge blocks and round (British) length bars. The GBI300 allows to calculate of central deviation, flatness and variation in length of measured gauge blocks. The Automatic Gauge Block Interferometer combines a conventional Twyman-Green Interferometer with high quality frequency stabilised lasers and computer interfaced instrumentation. The combination of phase-stepping method, image processing and computing techniques for analysis of the interferogram makes the instrument less dependent on operator skills. Two frequency-stabilized He-Ne lasers provide the light sources for the interferometry (633 nm and 543 nm). During the measurement up to twelve gauges can be wrung to a platen that has servo motor rotation control. It allows to measure gauge blocks faster and more accurate. The interferometer is placed in air conditioned laboratory with temperature change in interferometer chamber in range (19,9 ÷ 20,1) °C. The measuring chamber is placed on the granite table with vibroisolation system. The control cabinet houses the control equipment and instrumentation for measuring ambient conditions. The calibration method validation was performed by comparing measurement results with results from calibration certificate issued by National Physical Laboratory in United Kingdom. The uncertainty was evaluated on the basis of tests and measurements carried out in the laboratory.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 58-60
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies