Impact of the technological conditions of plane surface machining on a triangular milling cutter on the residual hysteresis of the movement axis of the machine
Autorzy:
Stejskal, T.
Kráľ, J.
Rudy, V.
Melko, J.
Rjabušin, A.
Pavliková, L.
Powiązania:
https://bibliotekanauki.pl/articles/957896.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
machine tools
laser interferometer
hysteresis
Opis:
The paper deals with the possibilities of measuring the residual displacement or hysteresis on the lateral direction of the movement forces caused by the cutting forces of the machining. A special adjustment of laser interferometry assemblies was used for measurement. The measurement results indicate that the positioning accuracy in addition to the cutting forces also influences the position of the displaced moving substances and the temperature. The complex effect of these parameters is greatly dependent on the design of the machine.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 3; 240-245
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elimination of thermal drift in measuring the positioning accuracy of a three axis milling machine
Autorzy:
Stejskal, T.
Dovica, M.
Demeč, P.
Svetlík, J.
Rajťuková, V.
Powiązania:
https://bibliotekanauki.pl/articles/102352.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
accuracy
laser interferometer
positioning
machine tool
Opis:
The aim of this paper is to draw attention to more reliable verification method of positioning accuracy. The improvement lies in mathematical elimination of thermal impact during the measurement process. This thermal impact, always present during the motion of movable parts, is of a special systemic character. It increases the indefiniteness of measurement of the classic measurement method. This measurement uncertainty can be reduced by implementing the procedure introduced in this paper. The reduction can be achieved by separating the temperature impact from other sources of inaccuracy. Such separation is a very new solution. The methodology relies on mathematical processing and does not depend on the manner of accuracy measurement. The evaluation method also yields diagnostic information on the machine’s condition. The experiments were performed with the use of laser interferometer.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 4; 159-167
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of static and dynamic laser based positioning methods for characterization of CNC machines
Autorzy:
Budzyn, G.
Rzepka, J.
Kaluza, P.
Powiązania:
https://bibliotekanauki.pl/articles/100137.pdf
Data publikacji:
2018
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
laser interferometer
ISO230
machine geometry
positioning measurement
Opis:
In the paper we compare the laser based measurements of linear parameters of numerically controlled machines. A new dynamic method of measuring machine positioning is described and compared with the widely used static method. The algorithms of the dynamic method are presented and the comparison results of both methods are shown. It is proven that with the new method the measurement time of linear errors of the CNC machines can be reduced significantly. Additionally the machine wear-out in the linear axes can also be easily and efficiently monitored.
Źródło:
Journal of Machine Engineering; 2018, 18, 4; 39-46
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Angular positioning accuracy of rotary table and repeatability of five-axis machining centre dmu 65 monoblock
Autorzy:
Józwik, J.
Czwarnowski, M
Powiązania:
https://bibliotekanauki.pl/articles/103390.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
positioning
diagnostics
accuracy
CNC machine tool
laser interferometer
Opis:
The study aims to evaluate angular positioning accuracy and repeatability of DMU 65 monoBLOCK numerically controlled machine tool. The measurements were carried out with XL-80 Laser Interferometer with XR20-W attachment. The measurements were conducted according to the standard PN-ISO230-2. Test methodology and measurement results analysis are presented in a form of figures and tables. The final part presents conclusions from the analysis.
Źródło:
Advances in Science and Technology. Research Journal; 2015, 9, 28; 89-95
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatic Laser Interferometer And Vision Measurement System For Stripe Rod Calibration
Autorzy:
Zhao, M.
Huang, Q.-H.
Zhu, L.-J.
Qiu, Z.-M.
Powiązania:
https://bibliotekanauki.pl/articles/221047.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
stripe edge
automatic control
laser interferometer
vision measurement
Opis:
In order to calibrate the stripe precision of a leveling rod, an automatic laser interferometer and a vision measurement system were designed by Xi’an University of Technology in China. The rod was driven by a closed-loop control and the data were collected at the stop state to ensure precision. The laser interferometer provided not only the long distance data but also a position feedback signal in the automatic control loop. CCD camera and a vision measurement method were used to inspect the stripe edge position and defect. Apixel-equivalent self-calibration method was designed to improve precision. ROI (regions of interest) method and an outline tracing method were designed to quickly extract multiple stripe edges. A combination of the image data with the interferometer data reduces control difficulty and ensures the measurement accuracy. The vision measurement method reached sub-pixel precision and the defective edges were reported. The system can automatically calibrate a stripe leveling rod with a high degree of efficiency and precision.
Źródło:
Metrology and Measurement Systems; 2015, 22, 4; 491-502
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on noises influencing the accuracy of CNC machine straightness measurements methods based on beam position detection
Autorzy:
Budzyn, Grzegorz
Rzepka, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/100115.pdf
Data publikacji:
2020
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
laser interferometer
ISO230
machine geometry
fibre laser
straightness measurement
Opis:
Fast, easy and accurate measurement of geometry of numerically controlled machines has always been challenging. With the use of a laser interferometer, it can be precise but it is complex. On the other side, the use of granite reference blocks is fairly easy yet quite limited for many machine types and sizes. Nowadays the improvements in technology open a new way – the instruments based on the detection of laser beam spot position. Those instruments are accurate and easy to use yet, comparing to the laser interferometers and granite blocks, they are sensitive to parameters of a laser source and to changing environmental conditions. In the paper, we analyse experimentally the influence of the type and parameters of laser source on the accuracy of straightness measurements. The most commonly met in practical applications a free space and fibre based laser sources are studied and compared. The influence of environmental conditions on measurement accuracy is also shown. Finally, the conclusions about optimal methods of improving the accuracy of beam position detection methods are drawn.
Źródło:
Journal of Machine Engineering; 2020, 20, 3; 76-84
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modernizacja przesuwu karetki pomiarowej na stanowisku komparatora interferencyjnego do wzorcowania wzorców kreskowych
Development of air-bearing stage for line scale interferometric comparator
Autorzy:
Sosinowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/155396.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wzorce kreskowe
pomiary interferencyjne
stolik powietrzny
line scales
laser interferometer
air-bearing stage
Opis:
W referacie przedstawiono budowę oraz zasadę pomiaru wykorzystywaną na komparatorze interferencyjnym do wzorcowania wzorców kreskowych oraz opisano modernizację posiadanego przez Laboratorium Długości Zakładu Długości i Kąta GUM stanowiska pomiarowego, która polegała na zaprojektowaniu i wykonaniu stolika powietrznego, zbudowanego z prowadnicy granitowej i łożysk powietrznych, napędzanego przez silnik krokowy. W artykule przedstawiono zalety zastosowanego rozwiązania, wyniki pomiarów wraz ze sposobem wyznaczenia błędów geometrycznych stolika powietrznego i ich wpływ na niepewność pomiaru wzorców kreskowych.
The line scales are important physical standards of length used for accurate positioning or measurement in one, two or three dimensions [1]. It plays an important role in ensuring the traceability of measurements made with instruments such as microscopes, measuring projectors, length measuring machines, measuring magnifiers or, more commonly used, vision systems for length measurements. The growing need for calibration of this type instruments and the need to ensure the accurate calibration of the line scales require maintaining and continuous upgrading of the line scale interferometric comparator. The calibration accuracy largely depends on the accuracy of the measuring carriage motion of the attached line scale in both the visual system and the laser interferometer, as the reference standard. The accuracy of measurement is affected by a number of factors, which causes that the measured value differs from the actual one. These factors are inaccurate execution and transmission wear, such as screw – nut system or the guide wear. By replacing the previously used mechanical movement with the precision air-bearing stage, a much smaller uncertainty of calibration of the line scales was achieved. The paper presents the modernized by the Length Laboratory of the Department of Length and Angle of GUM measuring station which allows the calibrations of the line scales of the nominal lengths from 1 mm to 500 mm, and describes the impact of angular errors of the measuring carriage on the measurement results.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 5, 5; 452-455
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technology of Precision Callibration of Electro-Optical Rangefinders Using Laboratory Methods and Field Test Baseline
Technologia kalibracji precyzyjnych dalmierzy elektrooptycznych z wykorzystaniem metod laboratoryjnych oraz polowej bazy testowej
Autorzy:
Szczutko, T.
Powiązania:
https://bibliotekanauki.pl/articles/385835.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
baza testowa
dalmierz precyzyjny
interferometr laserowy
kalibracja
test baseline
precision rangefinder
laser interferometer
calibration
Opis:
Rangefinders to obtain a length measurement error standard error determined the order of mD = ±(1 mm + 1 ppm) or less are in the group precision rangefinders. Rangefinders are applicable in the measurement of displacement, in the industrial measurement of short-range models, and as the length of the measuring equipment service points. Full use of this equipment requires a comprehensive examination. The paper gives examples of precision rangefinders research different companies: Leica, Trimble and Sokkia. Rangefinders Laboratory tests were performed in Metrologic Geodetic Laboratory of the Faculty of Mining Surveying and Environmental Engineering of AGH UST in Krakow. These measurements included the determination of cyclic errors in the 30 m based on the HP5529A laser interferometer. Field pattern of the length of a test baseline "Wisła" with a length of 1230 m is located on a stretch of the flood embankment of the river Vistula. It consists of 20 columns with heads measuring Kern enable forced centering. On the basis of measurements to determine the constant addition of the total set of EDM-reflector and rangefinder patch scale. Proposed the use of low-pass filter to optimize the calculation of atmospheric corrections to the measured length.
Dalmierze pozwalające uzyskać błąd pomiaru długości określony błędem standardowym rzędu mD = ±(1 mm + 1 ppm) lub mniejszy zaliczane są do grupy dalmierzy precyzyjnych. Dalmierze te mają zastosowanie w pomiarach odkształceń i przemieszczeń, w monitoringu budowli i powierzchni na terenach górniczych w pomiarach przemysłowych bliskiego zasięgu oraz jako wzorce długości dla dalmierzy niższej dokładności w punktach serwisowych sprzętu pomiarowego. Pełne wykorzystanie możliwości tego sprzętu wymaga wszechstronnego sprawdzenia. Procedury testowania mogą obejmować: -wyznaczenie stałej dodawania dla zestawu dalmierz-reflektor, -wyznaczenie poprawki skali dalmierza, -analizę występowania błędów cyklicznych, -analizę występowania błędów o charakterze nieliniowym zakresie krótkich odległości, -ocenę poprawności działania systemów ATR (Leica) lub Autolock (Trimble), -pomiar spójności fazy na powierzchni diody nadawczej dalmierza, -wyznaczenie parametrów dokładnościowych. W pracy podano przykłady badania dalmierzy precyzyjnych różnych firm: Leica - TCA2003, Di2002 i TDA5005, Trimble S8 oraz Sokkia NET05 z wykorzystaniem w pierwszej kolejności metod laboratoryjnych.
Źródło:
Geomatics and Environmental Engineering; 2014, 8, 4; 67-79
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania związane z występowaniem błędów cyklicznych w precyzyjnych dalmierzach elektrooptycznych
The study of the occurrence of cyclic errors in precise electromagnetic distance measuring instruments
Autorzy:
Szczutko, T.
Powiązania:
https://bibliotekanauki.pl/articles/385452.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
interferometr laserowy
błąd cykliczny
dalmierz elektroniczny
laser interferometer
cyclic error
electronic distance meter (EDM)
Opis:
W celu zapewnienia właściwej skali sieci geodezyjnych dalmierze stosowane do pomiaru powinny być odpowiednio kalibrowane, aby możliwe było wyeliminowanie z obserwacji błędów systematycznych pomiaru o charakterze liniowym oraz cyklicznym. Badaniem występowania błędów cyklicznych objęto dalmierze firmy Leica typu TC 2002, TCA 2003 oraz Geodimeter GDM 640 ATS. W celu zapewnienia odpowiedniej dokładności pomiaru jako wzorzec długości wykorzystano interferencyjny zestaw pomiarowy Hewlett-Packard HP 5529A zainstalowany w Geodezyjnym Laboratorium Metrologicznym AGH. Zastosowana technologia pomiaru umożliwia wyznaczenie wartości błędów cyklicznych dalmierzy z błędem średnim +/- 0,2 mm. Wyniki badań mogą być wykorzystane przy zakładaniu osnów specjalnych w pomiarach przemysłowych i laboratoryjnych.
In order to acquire the appropriate scale of geodetic special network, distance measuring instruments, which are used for measurement, should be calibrated in such a way as to eliminate systematic measurement errors of linear and cyclic character from the observation. Distance measuring instruments such as TC 2002, TCA 2003 made by Leica firm as well as Geodimeter GDM 640 ATS have been included in the study of the occurrence of cyclic errors. Hewlett-Packard HP 5529A interferential measurement set has been used as a length etalon to provide an appropriate accuracy of the measurement. The set is installed in Geodetic Metrological Laboratory of AGH. The applied measurement technology enables one to determine the values of cyclic errors of distance measuring instruments of and average error +/- 0,2 mm. The results of the study can be used in industrial and laboratory measurements while special networks are placed.
Źródło:
Geomatics and Environmental Engineering; 2007, 1, 1/1; 203-211
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania precyzyjnego sprzętu do niwelacji w geodezyjnym laboratorium metrologicznym AGH
The studies of precise levelling equipment in Geodetic Metrological Laboratory of AGH
Autorzy:
Beluch, J.
Frukacz, M.
Mróz, J.
Pokrzywa, A.
Szczutko, T.
Powiązania:
https://bibliotekanauki.pl/articles/385604.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
interferometr laserowy
kalibracja
łaty kodowe
niwelacja precyzyjna
laser interferometer
calibration
code staff
precise levelling
Opis:
Badanie precyzyjnego sprzętu do niwelacji polega na sprawdzeniu warunków geometrycznych niwelatora, poprawności działania poszczególnych jego elementów oraz kalibracji łat stosowanych w komplecie z instrumentem. W skład zestawu do badania sprzętu niwelacyjnego wchodzą: kolimatory optyczne, komora termiczna do wyznaczania współczynnika rozszerzalności termicznej wstęgi inwarowej łat oraz interferencyjny zestaw pomiarowy Hewlett-Pacard HP 5529A. Zestaw ten jest wykorzystywany do sprawdzania niwelatorów na bazie poziomej oraz kalibracji łat na komparatorze pionowym. Opracowana w Geodezyjnym Laboratorium Metrologicznym technologia kalibracji łat inwarowych pozwala na wyznaczenie wartości średniego metra łaty z błędem średnim rzędu 1,4-2,0 mim/m. W fazie testów znajduje się technologia kalibracji łat, technologia polegająca na zastąpieniu obserwacji optycznej analizą obrazu podziału łaty z kamery, z automatyczną eliminacją błędów systematycznych wnoszonych przez układ mechaniczny kolumny komparatora.
In order to examine precise levelling equipment one should check geometric conditions of the levelling instrument, the appropriacy of functioning of its single elements as well as the calibration of rods used in the set with the instrument. The set for studying the levelling equipment contains: optical collimators, a thermal chamber to calculate the coefficient of thermal expansion of the invar band rods and interferential measurement set Hewlett-Pacard HP 5529A. The set is used to check levelling instruments on horizontal base and the calibration of rods on the vertical comparator. The technology of invar rods developed in Geodetic Metrological Laboratory enables one to determine the values of the average horizontal metre of the rod with an average error of about 1.4-2.0 mim/m. Both the technology of the calibration of rods with the automatic elimination of systematic errors that are made by the mechanical system of the comparator column and substitution of the optical observation with the analysis of the picture of the rod graduation from the camera are still tested.
Źródło:
Geomatics and Environmental Engineering; 2007, 1, 1/1; 71-79
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies