Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "koszty ogrzewania" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Ocena efektów środowiskowych termomodernizacji na przykładzie budynku jednorodzinnego
Assessment of environmental effects of thermomodernization on the example of a detached house
Autorzy:
Żelazna, A.
Powiązania:
https://bibliotekanauki.pl/articles/1819345.pdf
Data publikacji:
2012
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
budynki jednorodzinne
termomodernizacja
zużycie energii
koszty ogrzewania
Opis:
Global warming is one of the major problems to be solved by international society. The inappropriate way of natural resources exploitation resulted in 50% increase of carbon dioxide equivalent concentration in the atmosphere. The introduction of sustainable development idea in the Brundtland report was the beginning of change in natural resources use perception. Also new agreements were introduced. Poland is one of the countries, which signed the Kyoto Protocol, and as the member of European Union, we are obliged to reduce amounts of CO2 emission to the atmosphere. Building construction industry is one of branches with great potential of reduction of CO2 emissions. Most of the environmental costs related to buildings is connected with its operational phase. It is assumed that there is about 7,3 mln of detached houses in Poland, and only 0,5 mln of them are new ones with good insulation parameters. Buildings which do not correspond with the requirements, have to be thermomodernized. This paper presents the results of economic and environmental analysis of detached house before and after thermal insulation of external walls. The elements of LCA methodology were used to establish the amounts of CO2 emitted during the production of insulation materials and during production of heat. These amounts were analyzed to establish the payback time for environmental costs of thermomodernization. This time was set up as shorter than one heating season.
Źródło:
Rocznik Ochrona Środowiska; 2012, Tom 14; 729-740
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ekonomiczne i ekologiczne koszty ogrzewania oraz optymalna grubość termoizolacji
Economic and ecological costs of heating and optimum thickness of the thermal insulation
Autorzy:
Dylewski, R.
Powiązania:
https://bibliotekanauki.pl/articles/112873.pdf
Data publikacji:
2017
Wydawca:
STE GROUP
Tematy:
optymalna grubość termoizolacji
ekonomiczne koszty ogrzewania
ekologiczne koszty ogrzewania
optimum thickness of thermal insulation
economic cost of heating
ecological cost of heating
Opis:
W artykule zaproponowano metodę wyznaczania ekologicznych kosztów ogrzewania na wzór metody wyznaczania ekonomicznych kosztów ogrzewania. Dzięki temu można analitycznie opisać ekologiczną, podobnie jak ekonomiczną, wartość bieżącą netto inwestycji termoizolacyjnej oraz wyznaczyć optymalną grubość termoizolacji zarówno ze względów ekonomicznych jak i ekologicznych. Zbadano różne przypadki występujące w warunkach polskich. Poddano wariantowości: materiał konstrukcyjny przegrody, rodzaj źródła ciepła, rodzaj materiału termoizolacyjnego. Uwzględniono tez różnorodność stref klimatycznych występujących w Polsce. Dla wszystkich zbadanych wariantów otrzymano grubość termoizolacji optymalną ze względów ekologicznych dużo większą niż ze względów ekonomicznych. Korzystne jest zastosowanie większych grubości termoizolacji niż optymalne ze względów ekonomicznych. Otrzymuje się wtedy większe korzyści ekologiczne z inwestycji termoizolacyjnej, przy niewielkim zmniejszeniu korzyści ekonomicznych.
This article presents the method of the assessment of the ecological costs of heating, which was modelled after the method for assessment of the economical costs of heating. Thanks to that, it is possible to analytically describe, in a similar fashion to the economic one, the ecological net present value of the thermal insulation investment, and to assess the optimum thickness of the thermal insulation both from the economic and ecological perspective. Different cases occurring in Polish conditions were also examined. Different variants were also analyzed: construction material of the building wall, type of a heat source, type of the thermal insulation material. The diversity of the climate zones in Poland was also taken into consideration. For all examined variants, the assessed optimal thickness of the thermal insulation layer from the ecological perspective was much bigger than from the economic perspective. Implementation of the greater thicknesses of the thermal insulation than the optimal from the economic perspective is beneficial. In this way, with the small decrease of the economical benefits, the greater ecological benefits from the thermal insulation investment are achieved.
Źródło:
Systemy Wspomagania w Inżynierii Produkcji; 2017, 6, 7; 68-83
2391-9361
Pojawia się w:
Systemy Wspomagania w Inżynierii Produkcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena energetyczno-ekonomiczna ogrzewania dendromasą
Power use and economic evaluation of dendromass heating
Autorzy:
Piszczalka, J.
Korenko, M.
Rutkowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/287543.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
biomasa
ogrzewanie
zużycie
gaz
drewno
koszty ogrzewania
dom jednorodzinny
biomass
house heating
gas consumption
wood use
heating costs
Opis:
Badaniami objęto dom jednorodzinny z okolic Nitry (Słowacja) o powierzchni mieszkalnej 138 m2 cechujący się dobrą izolacyjnością ścian. W budynku tym badano zużycie i koszty dwóch rodzajów paliwa (gazu i drewna) stosowanych do ogrzewania. Przy rocznym zapotrzebowaniu energii wynoszącym 94 000 MJ, spalanie drewna pozwala na uzyskanie oszczędności rzędu 35% wg cen gazu z roku 2003, zaś drewna z roku 2006.
A single family home from the Nitra area (Slovakia) having the area of 138 sq.m. and good wall insulation was selected for research. The consumption and cost of two types of fuel (gas and wood) used for heating were tested in the building. At annual energy demand of 94,000 MJ, burning of wood resulted in savings of about 35%, based on gas prices from 2003 and wood prices from 2006.
Źródło:
Inżynieria Rolnicza; 2007, R. 11, nr 6 (94), 6 (94); 189-196
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat pumps versus biomass boilers: a comparative analysis of heating costs for public buildings
Pompa ciepła versus kocioł na biomasę: analiza porównawcza kosztów ogrzewania budynków użyteczności publicznej
Autorzy:
Gradziuk, B.
Gradziuk, P.
Powiązania:
https://bibliotekanauki.pl/articles/1790008.pdf
Data publikacji:
2020
Wydawca:
The Polish Association of Agricultural and Agribusiness Economists
Tematy:
heating costs
renewable energy sources
heat pumps
biomass boiler
koszty ogrzewania
źródła energii odnawialnej
pompy ciepła
kocioł na biomasę
Opis:
The aim of the study is a comparative analysis of heating costs of heat pumps and biomass-fired boilers. The study was carried out in the communes of Ruda-Huta (Chełm County) and Dębowa Kłoda (Parczewski County). The subject of the study were school complexes in which the heating system was changed from heating oil to ground heat pumps and a boiler house, working on fine coal, replaced by a biomass-fired boiler-house. The Levelised Cost of Heat (LCOH) method was used to assess heating costs in both facilities. In Poland, according to data for 2018, the basic carrier of renewable energy used in heating was biomass (90.5%), where the share of heat pumps was only 0.4%. The study shows that such proportions, at least in the public utility buildings heating sector, are not economically justified. Average heating costs, estimated using the LCOH method, turned out to be over 20% higher in the case of biomass than in the case of heat pumps. The attractiveness of this technology in heating is evidenced by the development of this market in Europe. Similar trends are also taking place in the world market. Due to the fact that electricity is most often used to generate this type of heat, the development of this sector will highly depend on the relation between its prices and prices of other energy carriers.
Celem badań była analiza porównawcza kosztów ogrzewania przez zastosowanie pomp ciepła i kotła zasilanego biomasą. Badania przeprowadzono w gminach Ruda-Huta (powiat chełmski) i Dębowa Kłoda (powiat parczewski). Obiektem badań były zespoły szkół, w których dokonano zmiany systemu ogrzewania z zasilanego olejem opałowym na gruntowe pompy ciepła oraz kotłowni węglowej na opalaną biomasą. Do oceny kosztów ogrzewania w obu obiektach posłużono się metodą LCOH (Levelised Cost of Heat). W Polsce według danych dla 2018 roku, podstawowym nośnikiem energii odnawialnej stosowanym w ciepłownictwie była biomasa (90,5%), a udział pomp ciepła wyniósł jedynie 0,4%. Z przeprowadzonych badań wynika, że takie proporcje, przynajmniej w sektorze ogrzewnictwa budynków użyteczności publicznej, nie znajdują ekonomicznego uzasadnienia, bowiem uśrednione koszty ogrzewania, oszacowane z wykorzystaniem metody LCOH, okazały się o ponad 20% wyższe w przypadku zastosowania biomasy niż pomp ciepła. O atrakcyjności stosowania tej technologii w ogrzewnictwie świadczy rozwój tego segmentu rynku w Europie. Podobne tendencje występują również na rynku światowym. Z uwagi na to, że do wytwarzania tego rodzaju ciepła najczęściej wykorzystywana jest energia elektryczna, rozwój tego sektora uzależniony będzie od relacji jej cen do innych nośników energii.
Źródło:
Annals of The Polish Association of Agricultural and Agribusiness Economists; 2020, 22, 3; 77-85
2657-781X
2657-7828
Pojawia się w:
Annals of The Polish Association of Agricultural and Agribusiness Economists
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The TRIZ method in determining individual heating costs
Autorzy:
Adamski, Mariusz
Kapalo, Peter
Zhelykh, Vasyl
Voznyak, Orest
Dovbush, Oleksandr
Klymenko, Hanna
Kozydra, Natalia Olcha
Powiązania:
https://bibliotekanauki.pl/articles/2065614.pdf
Data publikacji:
2020
Wydawca:
Politechnika Częstochowska
Tematy:
heating costs
technical contradiction
reversed technical contradiction
physical contradiction
temperature
koszty ogrzewania
sprzeczność techniczna
odwrócona sprzeczność techniczna
sprzeczność fizyczna
temperatura
Opis:
The assumptions used in the calculation methods for housing heating costs are described in this paper. The results of calculations are influenced by the values of coefficients related to the location of flats in a building. A technical contradiction, a reversed technical contradiction and a physical contradiction were formulated. Based on the indicated inventive principles, the calculation methods for individual heating costs were analysed.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2020, 9, 1; 127--134
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The heat consumption and heating costs after the insulation of building partitions of building complex supplied by the local oil boiler room
Zużycie ciepła i koszty ogrzewania po dociepleniu przegród budowlanych zespołu budynków zasilanych z lokalnej kotłowni olejowej
Autorzy:
Życzyńska, A.
Powiązania:
https://bibliotekanauki.pl/articles/1366051.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
współczynnik przenikania ciepła
docieplenie przegród budowlanych
zużycie ciepła w budynku
koszty ogrzewania
heat transfer coefficient
insulation building partitions
heat energy consumption in a building
heating costs
Opis:
W artykule przedstawiono wskaźniki zużycia energii uzyskane w warunkach eksploatacyjnych i koszty ogrzewania przed i po dociepleniu przegród zewnętrznych grupy ośmiu budynków mieszkalnych wielorodzinnych zasilanych ze wspólnego źródła ciepła. Źródłem ciepła jest kotłownia lokalna opalana olejem opałowym lekkim, dystrybucja ciepła do poszczególnych budynków następuje poprzez osiedlową sieć ciepłowniczą. W celu określenia średnich jednostkowych wskaźników zużycia energii na cele grzewcze dla całego zespołu budynków przeprowadzono analizę zużycia paliwa uwzględniając standardowe warunki obliczeniowe. Analizą objęto okres czterech lat po dociepleniu budynków od 2008–2011 r. i odniesiono do stanu przed dociepleniem z 2006 r., inwestycja była realizowana w 2007 r. Uzyskane rzeczywiste wskaźniki zużycia energii porównano do obecnie obowiązujących wymagań warunków technicznych. Na podstawie danych z eksploatacji budynków przeanalizowano spadek zużycia ciepła z tytułu docieplenia przegród, zmienność cen paliwa i kosztów eksploatacyjnych ogrzewania, określono spadek emisji zanieczyszczeń do atmosfery, oszacowano koszty eksploatacyjne ogrzewania jakie zostałyby poniesione w przypadku braku docieplenia przegród budowlanych.
The paper presents the indices of energy consumption obtained in operating conditions as well as the heating costs before and after the insulation of external partitions of eight multiple dwelling buildings supplied by the common heat source which is the local boiler room heated by light fuel oil. The heat distribution to the particular buildings is by the district heating network. In order to determine the average unitary indices of energy consumption aimed at heating of the whole building complex, the analysis of fuel consumption is carried out, with consideration of standard computational conditions. The analysis lasted for four years after the insulation of buildings, from 2008 to 2011; its results are compared to the ones obtained from the analysis conducted before the insulation, in 2006. The investment was realised in 2007. The obtained real energy consumption indices are compared to the current requirements of technical conditions. On the basis of the data referring to the operation of buildings, the decrease in the heat consumption due to the insulation of partitions, the variability of fuel price, and the costs of heat generation are estimated. Moreover, the decrease in the emission of pollutants into the atmosphere is defined, as well as the costs of heat generation, which would be incurred if there was no insulation of partitions, are estimated.
Źródło:
Eksploatacja i Niezawodność; 2014, 16, 2; 313-318
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies