Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "kolektor powietrzny" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
The possibility of using solar air collector integrated with photovoltaic modules for air exchange in organic farms
Ocena możliwości wykorzystania słonecznego kolektora powietrznego zintegrowanego z układem fotowoltaicznym w gospodarstwach ekologicznych
Autorzy:
Sławiński, K.
Powiązania:
https://bibliotekanauki.pl/articles/335827.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
solar air collector
organic farm
solar energy
kolektor solarny
kolektor powietrzny
gospodarstwo ekologiczne
energia słoneczna
Opis:
The system comprising an air collector and a photovoltaic panel presented in this study allows an effective twenty-four-hour continuous supply of air exchange. The photovoltaic panel linked with the collector provides electricity to the fan that forces air circulation which, in combination with batteries, permits continuous operation. Solar energy through forced convection heats the air used in the drying process. Because the system uses solar energy (designed for this system), it is not dependent on electricity or other costly forms of energy. In the organic farm can be used for drying agricultural crops and herbs and for heating house and farm buildings.
System zawierający kolektor powietrza oraz panel fotowoltaiczny przedstawione w niniejszym opracowaniu umożliwia przez dwadzieścia cztery godziny ciągłą wymianę powietrza. Panel fotowoltaiczny połączony z kolektorem dostarcza energię elektryczną do wentylatora, który wymusza przepływ powietrza. W połączeniu z baterią, umożliwia to ciągłą jego pracę. Energia słoneczna przez wymuszoną konwekcję ogrzewa powietrze wykorzystywane w procesie suszenia. Ponieważ system wykorzystuje energię słoneczną to nie jest zależny od energii elektrycznej lub innych kosztownych form energii. W gospodarstwie ekologicznym może być używany do suszenia płodów rolnych, roślin leczniczych i przyprawowych oraz do wspomagania ogrzewania i cyrkulacji powietrza w domach mieszkalnych oraz budynkach gospodarczych.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2014, 59, 4; 69-71
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie właściwości eksploatacyjnych próżniowego kolektora słonecznego do grzania powietrza
Test performance characteristics of vacuum solar collector for heating air
Autorzy:
Śmierzchalski, R.
Trębowicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/156004.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
próżniowy kolektor powietrzny
badanie właściwości kolektora
sprawność kolektora
air collector
testing the properties of the collector
collector efficiency
Opis:
W pracy przedstawiono system do badania właściwości eksploatacyjnych oraz wyniki testów prototypowego próżniowego, rurowego kolektora słonecznego do grzania powietrza. Przedstawiono metody obliczenia sprawności na podstawie ilości energii przenoszonej oraz na podstawie konstrukcji kolektora z systemem rozprowadzania powietrza. Na podstawie badań określono parametry kolektora. Sprawność tego typu kolektora powietrznego jest prawie dwukrotnie większe w porównaniu do kolektora cieczowego.
The paper describes a vacuum solar collector for heating air - an innovative solution for distribution of the system medium - air heated in a vacuum solar collector [5]. A system for studying the properties and technical parameters of collectors and test results are presented. The energy absorbed in the air collector by an absorber is brought in a warm stream of the air flowing in collector channels - the system for distribution of the heated medium in the collector. The diagram of the system is shown in Fig. 1. To reduce costs there is proposed use of a vacuum tube in the solar collector to heat the air [4, 5]. The lack of intermediary medium (for example water) significantly improves the solar collector efficiency and provides no possibility of overheating of the collector during stagnation. An air collector with 20 vacuum tubes T (SHENTAI) was used for tests. Measurements of temperature and solar radiation were taken remotely. During the experiment continuous recording of the collector operating parameters under real conditions was carried out. The tests proved that the collector thermal efficiency depended on the level of solar radiation, the increased temperature relative to the solar efficiency remained at a constant level. The efficiency of the air vacuum collector (60%) is almost twice as large as that of the liquid collector.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 12, 12; 1567-1569
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar mocy cieplnej pasywnego, powietrznego kolektora słonecznego
Measurement of thermal power of passive solar air collector
Autorzy:
Dutkowski, K
Piątkowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/151292.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
powietrzny kolektor słoneczny
badania eksperymentalne
moc cieplna kolektora pasywnego
solar air collector
experimental investigations
heat efficiency
Opis:
W artykule przedstawiono wyniki badań eksperymentalnych prototypowego, powietrznego kolektora słonecznego. Badania przeprowadzono w warunkach laboratoryjnych. Ich celem było wyznaczenie wpływu natężenia promieniowania na przyrost temperatury powietrza oraz prędkość przepływu powietrza (na skutek ruchów konwekcyjnych). W efekcie pomiarów wyznaczono natężenie przepływu powietrza oraz moc cieplną kolektora. Pionierskie rozwiązanie konstrukcyjne jak i wyniki badań będą stanowiły punkt odniesienia dla wyników badań innych konstrukcji.
The results of experimental investigations of the prototype flat air solar collector are presented in this paper. The collector consists of an aluminum casing with dimensions 1.04 m (width) x 2.08 m (height) x 0.18 m (thickness). The air inlet to the collector has an inlet channel with diameter, din, of 110 mm and a length of 0.5 m. The air outlet channel has an internal diameter, dout, 130 mm and a length of 0.5 m. The prototype solar air collector has a cover made of a cellular polycarbonate with a thickness of 5 mm and in brown color. The study was performed on a laboratory set-up. The collector worked under conditions of natural convection. The tests were performed for a range of irradiance I = 0 - 325 W/m2. The absorber surface temperature variations, air temperature increase and the collector thermal power were determined. It was found that at maximum irradiation, the air velocity was w = 1 m/s, volume flow rate of air = 28 m3/h, and the corresponding heat transfer rate was Q = 270 W.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 10, 10; 868-871
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie układu regulacji temperatury powietrza ogrzewanego w próżniowym kolektorze słonecznym
The study of a temperature control system for the air heated in a vacuum solar collector
Autorzy:
Śmierzchalski, R.
Mikulski, P.
Powiązania:
https://bibliotekanauki.pl/articles/151132.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
kolektor słoneczny powietrzny
metody regulacji temperatury
badanie układu sterowania
solar collector for heating air
air mixing
methods of control output temperature
controllers
Opis:
W pracy przedstawiono badanie układu regulacji temperatury powietrza na zmodernizowanym stanowisku badawczym kolektora słonecznego. Zaprezentowano metody regulacji temperatury wyjściowej kolektora oraz wyniki z przeprowadzonych pomiarów. Na ich podstawie stwierdzono, że najbardziej efektywną metodą regulacji temperatury wyjściowej jest mieszanie powietrza z wykorzystaniem regulatora proporcjonalno-całkującego (PI).
The paper describes the study of a control system of a solar collector in the modernized station. The technical parameters and details of this innovative solution of collectors as well as the test results are presented in [1]. The basis of the solution is to use a novel method of mixing air to the control output temperature. The medium (air) heated by the collector at the output is mixed with the ambient air passing into the fan. The output temperature varies depending on the rotational speeds of the fans. The first section of the paper concerns the possibility of replacing fossil fuels with renewable energy development. It presents some aspects of the use of solar collectors for heating the air in the construction market in Poland. The second section contains the description of the modernized station for testing the control system of the solar collector (Fig.2). In the third section there is the block diagram of the control system of the solar collector (Fig.3) with its description. The fourth section contains the results of studies of the control system of the solar collector. There are presented the graphs of the output and setpoint temperature for heating and cooling processes, with one and two fans (air mixing). For each controller there is determined the setpoint by the method of manual tuning (engineering). On the basis of the studies it was found that the most effective method of output temperature control was the method of air mixing with a PI controller. For the air heating process the operation of one fan at the maximum speed is sufficient.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 8, 8; 560-563
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the influence of the heat-absorbing surface of an air-cooled solar collector on its thermal and mechanical properties
Autorzy:
Zhelykh, Vasyl
Ulewicz, Małgorzata
Kozak, Krystyna
Savchenko, Olena
Kasynets, Mariana
Powiązania:
https://bibliotekanauki.pl/articles/88616.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
solar air collector
heat-absorbing plate
flow turbulators
thermal power
air channel
powietrzny kolektor słoneczny
płyta pochłaniająca ciepło
turbulatory przepływowe
energetyka cieplna
kanał powietrzny
Opis:
This paper presents the analysis of existing forms of heat absorbing surfaces of air solar collectors, which gained the greatest popularity in the world. The obtained data allowed to conclude that there is a need for the development of solar collectors with air as a coolant with an improved form of heat absorber, which will reduce the operational and capital costs of solar systems and allow the efficient use of such structures in a moderate climate without additional mechanisms for the transfer of coolant. The use of computer simulation helped to compare the thermal characteristics of air-borne solar collectors of a different design. The substantiation of the expediency of installing as a heat absorber of flow turbulators in the form of a screw has been fulfilled, as well as the height of the air channel of the solar collector has been determined, in which the maximum heating of the transfer medium is observed. In addition, the loss of pressure in the air channel of the solar collector with flow turbulators was determined and the comparison of the obtained data with the values of pressure losses in the air collector of the matrix type and the air collector with V-shaped ribs was made.
Źródło:
System Safety : Human - Technical Facility - Environment; 2019, 1, 1; 481-489
2657-5450
Pojawia się w:
System Safety : Human - Technical Facility - Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Second law optimization and parametric study of a solar air heater having artificially roughened absorber plate
Autorzy:
Sahu, Mukesh Kumar
Prasad, Radha Krishna
Powiązania:
https://bibliotekanauki.pl/articles/240023.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
artificial roughness
entropy generation
entropy generation minimization
augmentation entropy generation number
solar air heater
źródło entropii
minimalizacja
powietrzny kolektor słoneczny
Opis:
In present article a mathematical model of arc shape wire roughened solar air heater, on the basis of energy and exergy output rates, entropy generation rate and augmentation entropy generation number, has been developed. A parametric study leading to entropy generation minimization has also been performed. In the analysis the geometric and operating parameters which have been considered as variable are: inlet air temperature, duct depth, collector width to duct depth ratio, mass flow rate per unit collector area, and temperature rise parameter. Results have been presented to see the effects of these values on the energy and exergy output rates of the roughened solar air heater. Effect of different values of wire rib roughness parameters on entropy generation has also been presented. Finally, design curves and optimization for different rib roughness parameters on the basis of minimum entropy generation number with temperature rise parameter, have been presented and optimum values also have been found out 0.004 to 0.010 (Km2 )/W. The entropy generation rate obtained for the system, in the present work has been compared with those obtained for solar air heater with different roughness geometries on absorber plates available in the literature for common roughness parameters and operating parameters which validate the present results.
Źródło:
Archives of Thermodynamics; 2019, 40, 2; 107-135
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Economic analysis of artificially roughened solar air heater with v-shaped ribs
Autorzy:
Bahuguna, Rahul
Chamoli, Sunil
Barthwal, Yogesh
Rana, Sumit
Gupta, Ashutosh
Bisht, Vijay Singh
Powiązania:
https://bibliotekanauki.pl/articles/2142836.pdf
Data publikacji:
2022
Wydawca:
Centrum Badań i Innowacji Pro-Akademia
Tematy:
solar air heater
heat transfer
artificial roughness
economic analysis
life cycle savings
powietrzny kolektor słoneczny
wymiana ciepła
sztuczna chropowatość
analiza ekonomiczna
oszczędności w cyklu życia
Opis:
Due to the minimal transfer of heat from absorber plate to moving air in the duct, solar air heaters have low performance. One of the procedures to augment the heat transfer by substantial amount is by utilizing artificial roughness, by which the performance can be improved considerably. In this study, an economic investigation of solar air heater embedded with artificial roughness is accomplished numerically employing v-shaped roughness, with the objective of optimising life cycle solar savings. The non-dimensional parameters of roughness, namely, angle of attack (α), roughness pitch (p/e) and roughness height (e/Dh) are examined by varying temperature rise over the solar air heater (∆T) and solar radiations (I) for different economic parameters values i.e., cost of collector, cost of roughness elements, and cost of conventional fuel.
Źródło:
Acta Innovations; 2022, 44; 18-33
2300-5599
Pojawia się w:
Acta Innovations
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of thermal processes in the solar air heater
Autorzy:
Zhelykh, V.
Kozak, C.
Powiązania:
https://bibliotekanauki.pl/articles/2068294.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska
Tematy:
energia słoneczna
słoneczny grzejnik powietrzny
pojemność cieplna
przepływ ciepła
kolektor słoneczny
instalacja solarna
solar energy
solar air heater
heat capacity
heat flow
solar collector
solar heating system
Opis:
The article sets out the place of solar energy in the world today. There are provided basic advantages and disadvantages of air quality heat capacity for solar heating system. Data for modeling heat flow system with passive energy use have been presented. Discussed methodology allows to determine the thermal characteristics of the air in the collector of the passive use of solar energy.
Определено энергетическое положение в мире в настоящее время. Поданы основные преимущества и недостатки воздуха в качестве теплоносителя для солнечной системы отопления. Представлены данные по применению теории графов для моделирования тепловых потоков в пассивном солнечном воздухонагревателе. Приведена методика определения тепловых характеристик воздушного гелиоколлектора с пассивным использованием солнечной энергии.
Źródło:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo; 2014, 20 (170); 285--289
0860-7214
Pojawia się w:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies