Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "jony ujemne" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Mathematical modeling of the aeroion mode in a car
Autorzy:
Biliaiev, Mykola
Pshinko, Oleksandr
Rusakova, Tetiana
Biliaieva, Viktoriia
Sładkowski, Aleksander
Powiązania:
https://bibliotekanauki.pl/articles/2203882.pdf
Data publikacji:
2022
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
negative ions
car ionizer
mathematical modeling
car passenger
comfort
jony ujemne
jonizator samochodowy
modelowanie matematyczne
pasażer
komfort
Opis:
In this study, a mathematical method is proposed for calculating the concentration field of air ions of different polarities and dust levels in the passenger compartment, taking into account the geometry of the passenger compartment and seats, shelves, and other internal elements of the passenger compartment. The method also takes into account changes in the rate of the air flow ventilation, the location and number of ionizers, and sources of positive ions and dust, taking into account their different intensities and locations. On the basis of a numerical model for this method, software has been developed that allows users to carry out computational experiments without requiring much time for calculation. Based on the results, the optimal location of the ionizer in the passenger compartment of the car was determined to ensure comfortable conditions for the stay of passengers, which favorably affects their health. It has been found that the presence of two ionizers is optimal for creating comfort in the car with an ionization intensity of Qn= 0.47 ×1010 ions/s located at the top of the car. If there is one ionizer located on the dashboard or at the top of the car with a higher ionization rate than ions/s, it is not possible to simultaneously provide optimal ionization parameters for passengers in the front and rear seats of the car.
Źródło:
Transport Problems; 2022, 17, 2; 19--32
1896-0596
2300-861X
Pojawia się w:
Transport Problems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficient nitrate adsorption from water by aluminum powder. Kinetic, equilibrium and influence of anion competition studies
Autorzy:
Fakhri, Y.
Kakavandi, B.
Safaei, Z.
Asadi, A.
Mohseni, S. M.
Golestanifar, H.
Powiązania:
https://bibliotekanauki.pl/articles/208008.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
aluminium compounds
kinetic parameters
kinetic theory
negative ions
nitrates
nitrogen removal
particle size
związki glinu
parametry kinetyczne
teoria kinetyczna
jony ujemne
azotany
usuwanie azotu
rozmiar cząstek
Opis:
The feasibility of aluminum powder (with particle size of 75–150 μm) for nitrate removal from aqueous solutions has been investigated. Adsorption was examined in function of initial nitrate concentration, contact time, pH and influence of other interfering anions. Maximum nitrate removal occurred at equilibrium pH of 10. The kinetics of adsorption of nitrate ions was discussed based on three kinetic models, namely: the pseudo-first order, the pseudo-second order and the intraparticle diffusion model. The experimental data fitted the pseudo-second order kinetic model very well; the rate constant was 4x10–4 g/ (mg·min) at the concentration of NO3- of 100 mg/dm3. The adsorption data followed both Langmuir (R2 = 0.808) and Freundlich (R2 = 0.865) isotherms probably due to the real heterogeneous nature of the surface sites involved in the nitrate uptake. The maximum sorption capacity of aluminum powder for nitrate adsorption was found to be ca. 45.2 mg/g at room temperature. The results indicate that aluminum powder is an interesting alternative for nitrate removal from the water.
Źródło:
Environment Protection Engineering; 2018, 44, 3; 19-31
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oddziaływanie elektronów z cząsteczkami o biologicznym znaczeniu
Interaction of electrons with biologically relevant molecules
Autorzy:
Kopyra, J.
Powiązania:
https://bibliotekanauki.pl/articles/171628.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Chemiczne
Tematy:
dysocjacyjny wychwyt elektronów
spektrometria mas
jony ujemne
cząsteczki o biologicznym znaczeniu
dissociative electron attachment
mass spectrometry
negative ions
biologically relevant molecules
Opis:
Recent years have witnessed an increase of the interest in the studies of the interaction of electrons with biologically relevant molecules. This has been mainly motivated by the seminal work, where it has been demonstrated that low energy electrons can induce single and double strand breaks in DNA in the energy range below the level of ionization. Since the damage profile as a function of electron energy showed pronounced resonances it was proposed that resonant electron capture could occur at particular molecular components of the DNA as the initial step towards strand breaks. From a series of experiments on electron attachment to DNA building blocks (nucleobases, the sugar moiety and the phosphate unit) became obvious that they effectively capture electrons leading to the formation of low energy resonances associated with the decomposition of the corresponding molecule. Recent dissociative electron attachment experiments on an entire gas phase nucleotide 2’-deoxycytidine-5´-monophosphate give also insight into the molecular mechanism involved, which comprises both direct electron attachment to the backbone and transfer of the excess electron from cytosine to the backbone resulting in single strand breaks. The results further allow an estimate of the relative contribution of these different mechanisms to single strand breaks.
Źródło:
Wiadomości Chemiczne; 2015, 69, 9-10; 893-907
0043-5104
2300-0295
Pojawia się w:
Wiadomości Chemiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zjonizowanego powietrza na organizm ludzki
Impact of ionized air upon human body
Autorzy:
Moga, M.
Małecka, I.
Powiązania:
https://bibliotekanauki.pl/articles/407560.pdf
Data publikacji:
2011
Wydawca:
Instytut Badawczo-Rozwojowy Inżynierii Lądowej i Wodnej Euroexbud
Tematy:
jony ujemne
jony dodatnie
organizm ludzki
zagrożenia mikrobiologiczne
dezynfekcja powietrza
negative ions
positive ions
human body
microbiological hazards
air disinfection
Opis:
Wpływ zjonizowanego powietrza na organizm ludzki zależy od wielkości jonów i ich biegunowości oraz koncentracji ich w powietrzu, a także od właściwości fizykochemicznych nośników jonów (aerozole, bakterie). Głównym źródłem energii jonizującej atomy i molekuły gazów wchodzących w skład powietrza atmosferycznego jest promieniowanie emitowane przez pierwiastki radioaktywne znajdujące się w powietrzu i skorupie ziemskiej. Z dużą dozą ostrożności należy podchodzić do sztucznej jonizacji w pomieszczeniach, w których nie dokonano liczbowo pomiarów ich koncentracji. W celu wyeliminowania zagrożeń mikrobiologicznych w układach instalacji wentylacyjnej należy poddać powietrze skutecznej dezynfekcji. Jony ujemne powietrza przyspieszają reakcje biologiczne, a mianowicie poprawiają zdolność koncentracji, przyspieszają gojenie się ran, zmniejszają uczucie bólu, ale z kolei przyspieszają wzrost komórek nowotworowych. Natomiast jony dodatnie powodują osłabienie, ból głowy, otępienie, zwiększone zapotrzebowanie na tlen oraz występujące także nierzadko objawy suchości w ustach i jamie nosowej.
The impact of ionized air upon the human body depends on the size of ions, their polarity and concentration in the air as well as physicochemical properties of ion carriers (aerosols, bacteria). The main source of energy ionizing gas atoms and molecules forming the atmospheric air is radiation emitted by radioactive elements found in the air and the earth's crust. A very cautious approach must be assumed when considering artificial ionization in rooms where their concentration has not been measured. In order to eliminate microbiological hazards in ventilation systems the air should be subject to effective disinfection. Negative air ions accelerate biological reactions, improve concentration ability, accelerate healing of wounds, reduce feeling of pain, however, they support growth of cancer cells. On the other hand, positive ions cause fatigue, headache, stupefaction, increased demand for oxygen and frequent symptoms of dryness in the mouth and nasal cavity.
Źródło:
Zeszyty Naukowe. Inżynieria Lądowa i Wodna w Kształtowaniu Środowiska; 2011, 4; 26-29
2082-6702
Pojawia się w:
Zeszyty Naukowe. Inżynieria Lądowa i Wodna w Kształtowaniu Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies