Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "jet fan" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
The application of a jet fan for the control of air and methane streams mixing at the excavations cross - the results of numerical simulations
Wspomaganie mieszania strumieni powietrza i metanu na skrzyżowaniu wyrobisk za pomocą wentylatora strumieniowego w ujęciu symulacji numerycznej
Autorzy:
Wrona, P.
Różański, Z.
Pach, P.
Domagała, L.
Powiązania:
https://bibliotekanauki.pl/articles/1205788.pdf
Data publikacji:
2016
Wydawca:
STE GROUP
Tematy:
CFD simulation
methane
gas hazard
jet fan
Opis:
The paper presents the results of numerical simulations into the distribution of methane concentration at the intersection of two excavations with a fan (turned on) giving the air stream to the area of the crossing. Assumed case represents emergency situation related to the unexpected flow of methane from an excavation and its mixing with fresh air. It is possible when sudden gas outburst takes place, methane leaks from methane drainage system or gas leaks out the pipelines of underground coal gasification devices. Three options were considered – corresponding to three different speeds of the jet fan. They represent three stages of fan work. First – low air speed is forced by a pneumatic fan, when electricity is cut off after high methane concentration detection. Medium speed can be forced by pneumatic-electric device when methane concentration allows to turn on the electricity. Third, the highest speed is for electric fans. Simulations were carried out in the Fire Dynamics Simulator (FDS) belongs to the group of programs Computational Fluid Dynamics (CFD). The governing equations are being solved in a numerical way. It was shown that proposed solution allows partial dilution of methane in every variant of speed what should allow escape of the miners from hazardous area.
W artykule przedstawiono wyniki symulacji komputerowych dotyczących zagadnienia rozkładu stężenia metanu przy skrzyżowaniu dwóch wyrobisk z włączonym wentylatorem kierunkującym strugę powietrza w rejon stropu skrzyżowania. Założona sytuacja dotyczyła awaryjnego wypływu metanu z zagazowanego wyrobiska do korytarza, którym płynie powietrze świeże. Taka sytuacja jest możliwa na przykład na skutek nagłego wyrzutu gazów, rozszczelnienia instalacji odmetanowania lub wycieku gazu z instalacji podziemnego zgazowania węgla. Rozpatrzono trzy warianty – odpowiadające trzem różnym prędkościom przepływu powietrza wywołanego pracą wentylatora pomocniczego. Pierwszy wariant dotyczy najmniejszej prędkości powietrza generowanej przez wentylator pneumatyczny, działający po odcięciu zasilania elektrycznego na skutek przekroczenia dozwolonego stężenia metanu. Drugi wariant to większą prędkość powietrza, generowana przez wentylator pneumatyczno-elektryczny. Trzeci wariant stanowi największą prędkość powietrza wytwarzaną przez wentylator elektryczny. Symulacje prowadzono w programie Fire Dynamics Simulator (FDS) należącym do grupy programów Computational Fluid Dynamics (CFD), rozwiązujących w swych algorytmach równania mechaniki płynów w sposób numeryczny. Wykazano, że zastosowanie proponowanego rozwiązania, umożliwi częściowe rozcieńczenie metanu w każdym z badanych wariantów, umożliwiając na przykład ucieczkę załogi z wyrobiska zagrożonego wybuchem.
Źródło:
Management Systems in Production Engineering; 2016, 3 (23); 156-162
2299-0461
Pojawia się w:
Management Systems in Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wentylacja oddymiająca w garażach – rozwiązania kontrowersyjnych problemów na przykładach projektowych
The Smoke Ventilation of Car Parks – Solutions to Controversial Issues Based on the Case Studies
Autorzy:
Brzezińska, D.
Ollesz, R.
Powiązania:
https://bibliotekanauki.pl/articles/373526.pdf
Data publikacji:
2017
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
wentylacja pożarowa
wentylacja strumieniowa
przejście ewakuacyjne
CFD
symulacje komputerowe
smoke ventilation
jet fan systems
exit way
simulations
Opis:
Cel: Celem artykułu jest próba odpowiedzi na wielokrotnie stawiane przez projektantów i rzeczoznawców ds. zabezpieczeń przeciwpożarowych pytania: Czy właściwe jest wydłużanie przejść ewakuacyjnych przy stosowaniu wentylacji strumieniowej? Czy występowanie w garażu dwóch kierunków ewakuacji jest w przypadku przejść ewakuacyjnych istotnym czynnikiem wpływającym na bezpieczeństwo ludzi? Czy symulacje komputerowe mogą być wystarczającym narzędziem do oceny kryteriów bezpiecznej ewakuacji użytkowników garażu bez względu na długość przejść ewakuacyjnych wynikającą z obowiązujących przepisów? Jakie czynniki rzeczywiście decydują o skuteczności działania systemów oddymiania garaży? Wprowadzenie: Bezpieczeństwo pożarowe w garażach, szczególnie podziemnych, jest w Polsce jednym z głównych tematów podejmowanych na wielu sympozjach i konferencjach. Szczególnie dyskusyjne są kwestie związane z oddymianiem garaży. Od wielu lat stosowane są dwa odmienne systemy oddymiania – strumieniowe i kanałowe, których skuteczność bywa różna. Projektanci, poza bezpośrednim spełnieniem obowiązujących przepisów, w celu zrealizowania i zweryfikowania systemów wentylacji pożarowej opierają się na dostępnych źródłach wiedzy technicznej oraz wynikach symulacji komputerowych. Mimo że analizy komputerowe zazwyczaj umożliwiają w danym garażu, przy zastosowaniu konkretnego systemu oddymiania, prawidłową ocenę warunków bezpiecznej ewakuacji użytkowników garażu i warunków prowadzenia działań gaśniczych, wciąż trwają dyskusje nad teoretycznymi różnicami w skuteczności działania wentylacji kanałowej i strumieniowej, szczegółowymi wymaganiami przepisów itp. Było to dla autorek motywacją do zaprezentowania niniejszego artykułu, w którym podjęto próbę odpowiedzi na najbardziej nurtujące pytania z zakresu projektowania systemów wentylacji pożarowej w garażach. Metodologia: Artykuł opracowano na podstawie najnowszej literatury przedmiotu oraz wynikach analiz rozprzestrzeniania się dymu i ciepła (dokonanych za pomocą symulacji komputerowej Computational Fluid Dynamics – CFD) w przykładowych garażach podziemnych. Przedstawione wnioski są poparte wieloletnią praktyką autorek w zakresie wykonywania w Polsce analiz zabezpieczeń przeciwpożarowych z wykorzystaniem metod inżynierskich. Wnioski: Ocena zaprezentowanych wyników symulacji komputerowych CFD pozwala stwierdzić, że obecnie obowiązujące w Polsce przepisy z zakresu ochrony przeciwpożarowej garaży są niedoskonałe. Najwłaściwszym podejściem do oceny poziomu bezpieczeństwa użytkowników garaży wydają się indywidualne analizy z wykorzystaniem metod inżynieryjnych i symulacji komputerowych. Przyglądając się obowiązującym przepisom, warto zwrócić uwagę na rozbieżności w wymaganiach stawianych w Polsce i w innych krajach. Wymagania te są znacząco różne zwłaszcza w przypadku dopuszczalnych długości przejść ewakuacyjnych. Szczególnym problemem w Polsce wydaje się brak zróżnicowania dopuszczalnych długości przejść w zależności od liczby dostępnych kierunków ewakuacji, na co w innych krajach kładzie się bardzo duży nacisk.
Aim: The aim of the article is to attempt to answer controversial questions asked for many years in Poland: Is it appropriate to extend the length of exit routes when jet-fan ventilation is used? Are the two-exitway directions in the event of evacuation are an important factor affecting the safety of people? Can computer simulations be a sufficient tool to assess the safe evacuation of car-park users, regardless of the length of exitways, as prescribed in the applicable regulations? What are the factors that actually determine the effectiveness of smoke-exhaust systems in car parks? Introduction: Fire safety in car parks, especially underground car parks, is one of the main topics of many symposia and conferences in Poland. The discussions are particularly related to their smoke-control systems. For many years, two alternative smoke-control systems – jet fans and ducts – have been competing with each other. Their effectiveness is often different. Designers, in order to achieve and verify fire-ventilation systems, rely both on regulations and the available sources of technical knowledge and computer simulations. Although most computer analyses allow unequivocal assessment of safety conditions in a specific car park, where a duct or jet-fan ventilation system is installed, there are ongoing discussions over theoretical differences in the effectiveness of these systems, specific requirements set out in the regulations in force, etc. This controversy inspired this article and motivated its authors to answer the most important questions centred around the problem of the designing of fire-ventilation systems in car parks. Methodology: The paper was developed based on the latest literature and the results of the authors’ own CFD (Computational Fluid Dynamics) analyses of smoke and heat spread in sample underground car parks. The presented conclusions are supported by the authors’ longstanding, practical experience in analyses of car-park smoke control systems, utilising engineering methods and performed all over Poland. Conclusion: The assessment of the CFD computer simulation results presented in the article leads to the conclusion that the current Polish regulations for fire protection in car parks are inadequate. The most appropriate approach to the assessment of the level of car-park user safety is usually an individual analysis using engineering methods and computer simulations. Looking at the applicable Polish law, it is worth paying attention to how the requirements differ from those in place in other countries, particularly in the case of requirements which are significantly different, especially as regards the maximum permitted lengths of exitways. The most important problem in Poland seems to be the lack of a difference between the maximum length of exitways where there is only one exit route (one direction) and where there are more exit directions
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2017, 45, 1; 130-141
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie narzędzi inżynierii bezpieczeństwa pożarowego w projektowaniu i odbiorze systemów wentylacji pożarowej garaży zamkniętych
The use of Fire Safety Engineering in the Design and Commissioning of Car Park Fire Ventilation Systems
Autorzy:
Krajewski, G.
Węgrzyński, W.
Powiązania:
https://bibliotekanauki.pl/articles/373478.pdf
Data publikacji:
2014
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
wentylacja pożarowa
garaże zamknięte
wentylacja kanałowa
wentylacja strumieniowa
fire ventilation
enclosed car parks
smoke and heat exhaust systems
jet-fan ventilation
Opis:
Cel: Przedstawienie wiedzy związanej z zastosowaniem narzędzi inżynierii bezpieczeństwa pożarowego na etapie projektu i odbioru systemów wentylacji pożarowej, ze szczególnym uwzględnieniem elementów układu równań będącego podstawą metody CFD, modeli fizycznych wykorzystywanych w obliczeniach oraz warunków brzegowych związanych z pożarem. Wprowadzenie: Projektowanie systemów wentylacji pożarowej garaży zamkniętych jest procesem skomplikowanym i wieloetapowym. Z uwagi na brak jednoznacznych krajowych wytycznych i jednoczesne postawienie w przepisach techniczno-budowlanych wymagań funkcjonalnych związanych z oceną skuteczności działania systemu proces ten jest trudny. Weryfikacja i ocena projektu wymaga szczegółowej wiedzy nie tylko z zakresu podstaw prawnych, ale również z zakresu wykorzystania nowoczesnych narzędzi inżynierskich takich jak metoda obliczeniowej mechaniki płynów (CFD) czy metod oceny skuteczności działania instalacji z wykorzystaniem gorącego dymu. Aby osoby mające styczność ze wspomnianymi analizami były w stanie samodzielnie ocenić podstawowe zagadnienia im przedstawiane, niezbędne jest zamknięcie podstawowej wiedzy z analizowanego zakresu w zwięzłe ramy, z jednoczesnym przedstawieniem bazy literaturowej, w której należy szukać odpowiedzi na trudniejsze pytania. Metodologia: W pracy przedstawione zostały wyniki analizy literatury tematu, badań własnych autorów publikacji przeprowadzonych w ramach projektu rozwojowego NR 04 0003 06 „Kontrola dymu i ciepła w garażach” oraz prac realizowanych w ramach tematów statutowych Instytutu Techniki Budowlanej oraz działalności bieżącej Zakładu Badań Ogniowych ITB. Wnioski: Wykorzystanie nowoczesnych narzędzi inżynierii bezpieczeństwa pożarowego, jakimi są analizy z wykorzystaniem metody obliczeniowej mechaniki płynów (CFD) oraz metoda gorącego dymu jest dzisiaj powszechną procedurą towarzyszącą niemalże każdemu projektowi systemu wentylacji pożarowej garażu zamkniętego. Przedstawiane wyniki analiz są często trudne w interpretacji i niejednoznaczne. Osoby prowadzące weryfikację tych projektów, funkcjonariusze PSP odpowiadający za odbiór i inne podmioty biorące udział w procesie projektowania muszą mieć świadomość źródła pochodzenia przyjętych założeń i uproszczeń i być w stanie zweryfikować podstawy ich zastosowania. Dopiero takie, w pełni świadome, wykorzystanie narzędzi, którymi dysponujemy, daje pewność, że wyniki analiz są bliskie rzeczywistości, a wnioski z nich płynące poprawne.
Aim: Presentation of technical know-how associated with the application of Fire Safety Engineering (FSE) tools during the design and commissioning stage of ventilation systems in enclosed car parks. Specific focus is placed on the presentation of differential equations which form the basis of the Computational Fluid Dynamics (CFD) technique, physical models used in computation and boundary conditions associated with fire incidents. Introduction: The design of fire ventilation systems in enclosed car parks is a long, complicated and multi-staged process. The absence of clear national guidelines and simultaneous functional requirements, stipulated in technical construction regulations about effectiveness of the operating system, make the task more difficult. Evaluation of the design requires explicit knowledge, not only about standards and legal requirements, but also about the application of most up to date engineering tools, such as the computation method of fluid dynamics CFD or performance evaluation of installations with the application of heated smoke. Individuals tasked with previously mentioned responsibilities should be suitably equipped to address basic issues. It is essential to encapsulate fundamental knowledge of relevant elements within a succinct framework. Simultaneously, appropriate literature should be identified and made accessible to assist with a search for answers to more difficult questions. Methodology: The article includes an analysis of relevant literature, studies conducted by authors under the auspices of a development grant nr. 04 0003 06 “Smoke and heat control in car parks” as well as statutory tasks performed by the Building Research Institute (BRI) and finally ongoing activities of the Fire Research Department of BRI. Conclusions: The use of modern FSE tools, such as CFD analysis or hot smoke performance evaluation are common procedures in current times. They are performed for almost every design of smoke and heat exhaust system in enclosed car parks. Interpretation of analysis results is often difficult and ambiguous. Individuals responsible for verification of the design, State Fire Service staff responsible for commissioning or others who participate in the project design have to understand the source of assumptions and simplifications which are made and be in a position to verify the basis for their application. Only such cognisant use of FSE tools will give confidence that evaluation results are close to reality and subsequent conclusions are correct.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2014, 4; 141-156
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies