Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "izolator ceramiczny" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Aluminous porcelain degradation study using mechanoacoustic and microscopic methods
Autorzy:
Ranachowski, P.
Rejmund, F.
Ranachowski, Z.
Pawełek, A.
Piątkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/140868.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
porcelana
izolator ceramiczny
emisja akustyczna
analiza mikroskopowa
degradacja struktury
aluminous porcelain
ceramic insulators
insulator testing
acoustic emission
microscopic analysis
structural degradation
Opis:
This experimental paper comprises the results of acoustic emission (AE), microscopic and ultrasonic measurements of samples subjected to slowly increasing compressive stress. On the basis of conducted measurements the successive stages of the material structural degradation have been recognized. The objects of study were samples made of C 120 aluminous porcelain. The investigated material has found at present the application in the fabrication of technical elements like overhead power line insulators. In the case of such objects, not only high mechanical strength, but especially elevated durability as well as operational reliability are required. The expected "life time" of net insulators during exploitation is about 40 years. The analysis of obtained mechanoacoustic dependences pointed out a complex mechanism of degradation of the material. Microscopic investigation of samples, which were stressed to different levels of load, enabled to specify the development of gradual growth of microcracks and successive crushing out of elements of the structure. These processes appear to be similar to the ageing processes occurring in the material during long period of exploitation under a working load. Three stages of the structure degradation were distinguished. The preliminary and subcritical ones show low or moderate intensity of AE signals and considerable variety for the particular samples. The critical stage directly precedes the destructtion of samples. Its range is relatively narrow and reveals the AE activity of high energy. The effectiveness of dispersive and fibrous reinforcement of modern aluminous porcelain C 120 type has been described. Structural strengthening by corundum grains and mullite needle shaped crystals improves mechanical parameters and distinguishes this material from typical aluminosilicate ceramics. The presented results enable drawing up the conclusions concerning the resistance of investigated material to the ageing degradation process development during long term operation.
Źródło:
Archives of Electrical Engineering; 2011, 60, 2; 109-128
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electric field distribution in spark plugs insulators - modeling and computer simulation
Rozkład pola elektrycznego w izolatorach świec zapłonowych - modelowanie i symulacja komputerowa
Autorzy:
Fryśkowski, B.
Powiązania:
https://bibliotekanauki.pl/articles/328503.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
spark plug
automotive ignition systems
ceramic insulator
electric field
finite difference method
świeca zapłonowa
układ zapłonowy
izolator ceramiczny
pole elektryczne
metoda różnic skończonych
Opis:
Automotive spark plugs are essential ignition circuit components being of importance for combustion engine reliability and performance. The majority of spark plugs have ribbed ceramic insulator to ensure high resistance along the surface from the terminal to the metal shell to minimize leakage current and to provide flashover protection. The leakage current intensity depends on electric field distribution, physical insulator properties and such factors as humidity, insulator contamination or defects in insulation material. Furthermore, leakage current not infrequently interferes with discharge process causing misfire effect being harmful to exhaust manifold components, mainly to catalytic converters. This paper presents simulation results of electric field distribution in ceramic insulator, in silicone rubber boot and in space surrounding a spark plug. Assuming that a spark plug can be considered as an object having cylindrical symmetry the electric field distribution was calculated for a two-dimensional case in accordance with Laplace’s and Poisson’s equations. In this paper, the finite difference method (FDM) for the solution of the Laplace’s equation was applied. The FDM algorithm based on the Liebmann’s method was developed in the MATLAB environment. Presented simulation results can be helpful to automotive spark plugs and high-tension cables manufacturers interested in improvement of insulating properties.
Samochodowe świece zapłonowe zaliczane są do podzespołów układów zapłonowych ważnych z punktu widzenia niezawodności i sprawności silnika spalinowego. Większość świec zapłonowych posiada izolator ceramiczny z barierami zapewniający wysoką wartość rezystancji między zaciskiem elektrody środkowej i korpusem w celu ograniczenia natężenia prądu upływu i zapobiegania zjawisku wyładowania powierzchniowego. Natężenie prądu upływu uzależnione jest od rozkładu pola elektrycznego, właściwości fizycznych izolatora i takich czynników jak wilgotność, zanieczyszczenie lub uszkodzenia materiału izolacyjnego. Nierzadko prąd upływu zakłóca przebieg procesu wyładowania iskrowego prowadząc do wypadania zapłonów, które stanowi zagrożenie dla elementów układu wydechowego, głównie dla katalizatorów. W treści artykułu przedstawiono wyniki symulacji komputerowej rozkładu pola elektrycznego w izolatorze, silikonowej osłonie izolacyjnej oraz w przestrzeni otaczającej świecę zapłonową. Przyjmując założenie, że świecę zapłonową charakteryzuje symetria osiowa, wyznaczono rozkład pola elektrycznego w postaci dwuwymiarowej korzystając z oprogramowania MATLAB. Obliczenia wykonano rozwiązując równania Laplace’a i Poissona metodą różnic skończonych przy zastosowaniu procedury Liebmanna. Przedstawione wyniki symulacji komputerowej mogą być przydatne dla producentów samochodowych świec i przewodów zapłonowych zainteresowanych poprawą właściwości izolacyjnych.
Źródło:
Diagnostyka; 2017, 18, 1; 87-93
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies