Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "ion beam" wg kryterium: Temat


Tytuł:
Accelerators in materials research
Autorzy:
Turos, A.
Powiązania:
https://bibliotekanauki.pl/articles/147928.pdf
Data publikacji:
2005
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
materials research
accelerators
ion beam modification
ion beam analysis
Opis:
Abstract Since at least forty years accelerators of charged particles no longer belong to nuclear physics exclusively. This is especially true for accelerators at energies below 1 GeV. The vast majority of accelerators in this energy range is used for materials research and medicine. In materials research the applications are principally twofold: modifications of solids and surface layer microanalysis. Two most important challenges for materials research at the beginning of XXI century as determined by the Materials Research Society are: development of materials able to repair human body and development of materials for new electronic devices able to cope with the enormous amount of information to be stored and transmitted. The role of accelerators with regard to the challenges of modern technology will be discussed.
Źródło:
Nukleonika; 2005, 50,suppl.3; 11-15
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The proton beam energy measurement by a time-of-flight method
Autorzy:
Kisieliński, M.
Wojtkowska, J.
Powiązania:
https://bibliotekanauki.pl/articles/148266.pdf
Data publikacji:
2007
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
beam diagnostics
cyclotron
ion beam
Opis:
A simple TOF equipment for cyclotron protons beam energy measurement was constructed. For short distance of 165 cm between capacitive pick-up probes, the accuracy of proton beam energy is below 1% for mean beam currents above 200 nA and within the energy range 20 30 MeV.
Źródło:
Nukleonika; 2007, 52, 1; 3-5
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Status of ISL
Autorzy:
Homeyer, H.
Powiązania:
https://bibliotekanauki.pl/articles/146213.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
accelerator operations
ion beam technologies
Opis:
The Ion Beam Laboratory (ISL), operated by the Hahn-Meitner-Institut, Berlin, is exclusively dedicated to ion beam applications-technologies in materials science and medicine. ISL provides beams of light and heavy ions from various accelerators, and combinations of accelerators, with energies ranging from 10 eV to several 100 MeV. It operates various permanently installed target areas equipped with specific instruments for the different ion beam applications and fundamental ion solid state interaction research.
Źródło:
Nukleonika; 2003, 48,suppl.2; 127-130
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Post acceleration of ions emitted from laser and spark - generated plasmas
Autorzy:
Torrisi, L.
Cavallaro, S.
Rosiński, M.
Nassisi, V.
Paperny, V.
Romanov, I.
Powiązania:
https://bibliotekanauki.pl/articles/146658.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
post ion acceleration
laser plasma
ion beam
ion implantation
Opis:
Pulsed lasers at intensities of the order of 1010 W/cm2 interacting with solid matter in vacuum, produce hot plasmas at high temperatures and densities. The charge state distributions of the plasma generate a high electric field, which induces high ion acceleration along the normal to the target surface. The high yield of the emitted ions can generate a near constant current by using repetitive pulses irradiating thick targets. In order to increase ion energy, a post-acceleration system can be employed by using acceleration voltages above 10 kV. Special ion extraction methods can be employed to generate the final ion beam, which is multi-ionic and multi-energetic, due to the presence of different ion species and of different charge states. In this article four different methods of post ion acceleration, employed at the INFN-LNS of Catania, at the IPPLM of Warsaw, at the INFN of Lecce and at the LPI of Moscow, are presented, discussed and compared. All methods are able to implant ions in different substrates at different depth and at different dose-rates.
Źródło:
Nukleonika; 2012, 57, 3; 323-332
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studies of plasma and craters produced by the interaction of high-energy sub-nanosecond laser with silver target
Autorzy:
Woryna, E.
Badziak, J.
Parys, P.
Suchańska, R.
Wołowski, J.
Krása, J.
Láska, L.
Pfeifer, M.
Rohlena, K.
Ullschmied, J.
Powiązania:
https://bibliotekanauki.pl/articles/147102.pdf
Data publikacji:
2002
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ion beam
laser
laser-induced crater
plasma
Opis:
The results of measurements of microablation from a silver target irradiated by the high-power PALS laser system in Prague are presented. In this experiment the laser beam of energy of about 110 J in a 400 ps pulse was focused perpendicularly to the massive silver target. The target surface position was changed with respect to the focal spot of the laser beam in the range from -2.5 to 2.5 mm. A set of four ion collectors was used for plasma ion emission measurements. The effect of the laser pulse interaction with the target, i.e. craters and damages formed in the vicinity of the craters, were investigated with the use of scanning electron microscopy (SEM) and optical microscopy methods. The characteristics of the crater were compared with the essential parameters of ion streams emitted from the plasma produced in the same laser shot.
Źródło:
Nukleonika; 2002, 47, 4; 147-150
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Suppressing of Co-Extracted Electrons in a Negative Ion Source-Numerical Simulation
Autorzy:
Turek, Marcin
Węgierek, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2201879.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
particle-in-cell simulations
negative ion source
ion beam extraction
Opis:
Electron co-extraction and suppression by a transverse magnetic fields is studied within a two dimensional particle-in-cell numerical model of surface ionisation ion source with beveled extraction opening. A novel approach of data presentation is proposed, based on the fact that dependences of co-extracted current on the filter strength could be approximated by four parameters only, describing e.g. initial electron current value and cut-off B value. In the paper the influence of extraction system geometry is considered – it is shown that the cut-off B value increases with the size of the opening in the extraction electrode, while the inclination of the extraction opening walls does not play any significant role. It is demostrated that the most of electron is eliminated by hiting the extraction electrode walls, however up to 30 % of electrons were lost by encountering the extraction channel walls due to the modification of their trajectories by the filter field. The influence of the magnetic filter field placement is also investigated – the center of the filter field has to be no further than 2 mm form the extraction channel orifice in order to achieve minimal values of the cut-off field (~20 mT). The possibly low extraction voltages are preferable, as the ammount of co-extracted electrons grows rapidly with Vext resulting in e.g. threefold increase of cut-off parameter value when extraction voltage is changed from 1 kV up to 10 kV. Within the considered model the filter field does not have any significant influecne on extracted H- current.
Źródło:
Advances in Science and Technology. Research Journal; 2022, 16, 5; 1--10
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of a large beam facility
Autorzy:
Oh, B.
In, S.
Lee, K.
Jeong, S.
Seo, C.
Chang, D.
Powiązania:
https://bibliotekanauki.pl/articles/147420.pdf
Data publikacji:
2006
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
beam facility
high power ion beam
o neutral beam
beam line component
cryosorption pump
Opis:
A large beam facility for the application of high power ion beams has been developed at the Korea Atomic Energy Research Institute (KAERI). The primary usage of this facility is to develop an 8 MW neutral beam heating system for a tokamak, but other applications using a large beam would also be possible in the near future. The facility is composed of a bucket ion source (120 kV, 65 A), related beam line components including a large vacuum chamber (3 m x 4 m x 5 m), power supplies for the ion source, control and DAS (Data Acquisition System), beam diagnostics system, and a water circulation system (2 MW) for cooling of the beam line components. The maximum beam parameters at present are a beam energy of 87 kV and a beam current of 17.5 A with a beam size of 13 x 45 cm2. A maximum pulse length of 10 s could be achieved with a 1 MW beam power. The beam power with a hydrogen ion will be increased up to 7.5 MW during 5 s.
Źródło:
Nukleonika; 2006, 51, 1; 37-42
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Neutron and fast ion emission from PF-1000 facility equipped with new large electrodes
Autorzy:
Szydlowski, M.
Scholz, M.
Karpinski, L.
Sadowski, M.
Tomaszewski, K.
Paduch, M.
Powiązania:
https://bibliotekanauki.pl/articles/147301.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
fast ion beam
neutron emission anisotropy
neutron yield
plasma focus
Opis:
A PF-1000 facility was operated for the first time at an energy level of up to 1 MJ. The maximal emission of 2×1011 neutrons/shot was registered. Relatively low emission anisotropy was observed. Fast ion beams were generated only from shots performed at a low filling pressure (1-2 Torr).
Źródło:
Nukleonika; 2001, 46, suppl. 1; 61-64
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Implanted manganese redistribution in Si after He+ irradiation and hydrogen pulse plasma treatment
Autorzy:
Werner, Z.
Pochrybniak, C.
Barlak, M.
Piekoszewski, J.
Korman, A.
Heller, R.
Szymczyk, W.
Bocheńska, K.
Powiązania:
https://bibliotekanauki.pl/articles/147018.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dilute magnetic semiconductors (DMS)
Mn-implanted Si
ion beam induced epitaxial crystallization
Opis:
Si-Mn alloy with a Mn content of a few percent is potentially a candidate for room temperature (RT) dilute magnetic semiconductor (DMS). However, the present methods of material manufacture suffer from problems with poor Mn solubility and thermodynamical limitations. We study a non-equilibrium method in which silicon is first implanted with 160 keV manganese ions to a dose of 1 × 1016 ions/cm2 and next either irradiated with 1.5 MeV 4He+ ions from the Warsaw Van de Graaff accelerator at 400°C or treated with high-energy hydrogen plasma pulses. Conclusion from Rutherford backscattering spectrometry (RBS) examination of the samples is that both approaches lead to recovery of crystalline surface layer with manganese occupying off-substitutional sites. The potential development of the method is discussed.
Źródło:
Nukleonika; 2011, 56, 1; 5-8
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of powerful pulses of hydrogen plasma upon materials in PF-1000 device
Autorzy:
Pimenov, V.
Gribkov, V.
Dubrovsky, A.
Mezzetti, F.
Scholz, M.
Ugaste, U.
Dyomina, E.
Ivanov, L.
Maslyaev, S.
Miklaszewski, R.
Borowiecki, M.
De Chiara, P.
Pizzo, L.
Szydlowski, A.
Volobuev, I. V.
Powiązania:
https://bibliotekanauki.pl/articles/147096.pdf
Data publikacji:
2002
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dense plasma focus (DPF)
ion beam
irradiation
plasma jet
surface damage
test specimen
Opis:
The results of experimental investigations of powerful hydrogen plasma jets and fast ion beams interaction with various materials (austenitic chromium-manganese steels, pure vanadium, tungsten, graphite, copper, and their alloys: Cu-4 mass% Ni and Cu-10 mass% Ga) are presented. The materials were placed on the discharge axis of the PF-1000 device and irradiated with fluxes of fast ions (of energy in the range from tens keV up to several MeV) and with plasma streams (of power flux density q~(108 109) W/cm2). It was found that the fast ions and plasma streams caused different damages to the aforementioned materials. A diverse character of the damages to the individual investigated material was revealed. Some peculiarities of the process as well as the correlation between the surface density of the "macroscopic" structural defects (blisters and craters) and the fluence of the fast ions implanted in the specimen are discussed.
Źródło:
Nukleonika; 2002, 47, 4; 155-162
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On possible formulation of problems of a Dense Plasma Focus used in material sciences
Autorzy:
Gribkov, V.
Powiązania:
https://bibliotekanauki.pl/articles/146787.pdf
Data publikacji:
2000
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
cumulative plasma streams
dense plasma focus (DPF)
electron beam
ion beam
material sciences
neutrons
X-rays
Opis:
The paper describes various possibilities at can be given by the use of dense plasma focus (DPF) device in material sciences. Main distinguishing features of such a device – availability of several different types of hard radiation and its high power flux density – determine the niche of applications of this type devices in the field. Some directions of materials investigation and treatment, which can be developed at present time, are discussed.
Źródło:
Nukleonika; 2000, 45, 3; 149-153
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary właściwości elektrycznych nanokompozytów o strukturze stop metaliczny FeCoZr w matrycy dielektrycznej PbZrTiO3
Measurements of electrical properties of nanocomposite containing metallic alloy FeCoZr in a PbZrTiO3 dielectric matrix
Autorzy:
Boiko, O.
Kotunowicz, T.N.
Powiązania:
https://bibliotekanauki.pl/articles/408633.pdf
Data publikacji:
2015
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
nanokompozyty
rozpylanie jonowe
układy RLC
pomiary częstotliwościowe
nanocomposites
ion beam sputtering
RLC circuits
frequency measurements
Opis:
W pracy przedstawiono wyniki pomiarów zmiennoprądowych właściwości elektrycznych ziarnistych nanokompozytów o strukturze (FeCoZr)x(PZT)(100-x). Praca zawiera wstępną analizę parametrów elektrycznych (pojemność Cp, tangens kąta strat dielektrycznych tgδ, rezystancja Rp
Here, the AC electrical properties measurements of (FeCoZr)x(PZT)(100-x) granular nanocomposites are studied. The work contains a preliminary analysis of the electrical parameters (capacitance Cp, loss coefficient tgδ, resistance Rp and phase angle θ) for nanocomposite samples with different metallic phase content x studied in the frequency range 50 Hz – 5 MHz and temperature range 15 K – 375 K. It was established that the AC phenomena are typical for the conventional RLC circuits
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2015, 3; 65-70
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of a weak ion beam treatment of emission layer on the top emission polymer light-emitting diode
Autorzy:
Gong, T
Gwag, J S
Powiązania:
https://bibliotekanauki.pl/articles/174367.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
organic light emitting diode
light-emitting polymer
top emission
optical device
ion beam
surface treatment
Opis:
This study examined the influence of a weakly treated emission layer on ion beam processing for the performance of top emission polymer light-emitting diodes with an invert structure (top ITO as the anode). The emission layer used in this experiment was a polymer type SY, Livilux PDY-132 provided by Merck & Co. The surface of the emission layer was modified by a low energy ion beam treatment to obtain hydrophilic functional groups and improve the wettability. As a hole transfer layer, poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS, CLEVIOS AI 4083, Heraeus) was spin-coated on the ion beam treated emission layer and showed good adhesion properties. Consequently, through such an ion beam treatment that promotes the interface properties of these two layers, a uniform light emitting area was obtained and the light intensity in a top emission polymer light-emitting diode was improved.
Źródło:
Optica Applicata; 2014, 44, 4; 567-574
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PF-6 an effective plasma focus as a source of ionizing radiation and plasma streams for application in material technology, biology and medicine
Autorzy:
Gribkov, V.
Dubrovsky, A.
Scholz, M.
Jednorog, S.
Karpiński, L.
Tomaszewski, K.
Paduch, M.
Miklaszewski, R.
Pimenov, V.
Ivanov, L. I.
Dyomina, E. V.
Maslyaev, S. A.
Orlova, M. A.
Powiązania:
https://bibliotekanauki.pl/articles/147424.pdf
Data publikacji:
2006
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dense plasma focus (DPF)
ion beam
plasma beam
X-ray beams
surface damage
microlithography
radioenzymology
positron emission tomography (PET)
Opis:
A review of results on the design and operation of the new efficient Dense Plasma Focus device PF-6 of medium size (transportable) having bank energy of ca. 7 kJ and possessing a long lifetime is presented. New data on the interaction of the pulsed fast ion beams and dense plasma streams generated at this apparatus with various materials are given. These results are compared with the analogous information received at the biggest facility PF-1000. It is shown that it is possible to have about the same power flux density (in the range of 105 109 W/cm2) in both devices however in different areas. Doses of soft X-rays produced by the device within the resists for the goals of microlithography and micromachining appear to be several times less that it is with the conventional X-ray tube. In biological application of this device, medium- and hard-energy X-rays are exploited in the field of radioenzymology. It was found that the necessary dose producing activation/inactivation of enzymes can be by several orders of magnitude lower if used at a high-power flux density in comparison with those received with isotope sources. In medicine, short-life isotope production for the goals of the positron emission tomography (medicine diagnostics) is possible by means of the fast ions generated within DPF. All these experiments are discussed in the framework of pulsed radiation physics and chemistry in its perfect sense thereto the criteria are formulated.
Źródło:
Nukleonika; 2006, 51, 1; 55-62
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurements of electron and ion beams emitted from the PF-1000 device in the upstream and downstream direction
Autorzy:
Kwiatkowski, R.
Skladnik-Sadowska, E.
Malinowski, K.
Sadowski, M. J.
Czaus, K.
Zebrowski, J.
Karpinski, L.
Paduch, M.
Scholz, M.
Garkusha, I. E.
Kubeš, P.
Powiązania:
https://bibliotekanauki.pl/articles/146626.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
electron beam (EB)
ion beams
PF-1000 facility
magnetic analyzer
ion pinhole cameras (IPC)
Opis:
In this paper we report on measurements of the energy spectra and other properties of the electron and fast ion beams emitted in the upstream and downstream direction along the z-axis of a large plasma focus device PF-1000, that was operated at 21-27 kV, delivering 290–480 kJ pulse. Measurements of the electron beam (EB) properties were performed using a magnetic analyzer. Properties of the ion beams were measured by means of pinhole cameras equipped with PM-355 nuclear track detectors and placed at various angles (0, 60 and 180 centigrade) to the discharge axis. Measurements revealed a complex spatial structure of the fast ion beams. The ion measurements behind the PF-1000 collector proved that some fast deuterons are emitted also in the upstream direction. Measurements of the EBs emitted in the upstream and downstream direction revealed electron energies in the range from approximately 40 keV to approximately 800 keV. These spectra confirm that in localized regions within the PF-1000 plasma column there appear strong fields accelerating charged particles in different directions along the discharge axis.
Źródło:
Nukleonika; 2011, 56, 2; 119-123
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies