Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "inzynieria srodowiska" wg kryterium: Temat


Tytuł:
Geofizyka w inżynierii i ochronie środowiska
Geophysics in environmental engineering and protection of the environment
Autorzy:
Zuberek, W. M.
Powiązania:
https://bibliotekanauki.pl/articles/183612.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
geofizyka
inżynieria środowiska
ochrona środowiska
katastrofy naturalne
prognoza
geophysics
environmental engineering
environmental protection
natural catastrophes
prediction
Opis:
The main goals of geophysics have been considered in following areas: - prediction and prevention of natural catastrophes and mitigation of their impact, - detection, location and monitoring of contaminated areas and goals related to their reclamation, - goals related to the safety of large and important structures and constructions, - goals related to safe deposition, storage and monitoring of dangerous wastes and toxic materials, - application of geophysical methods and observations to obtain "clean" and renewable energy, - detection, location and dating of archeological materials and monuments of cultural heritage. Due to the great importance of prediction in environmental engineering and protection, its possibilities and limitations have been considered separately.
Źródło:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie; 2009, 35, 2/1; 421-428
0138-0974
Pojawia się w:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka emisji elektromagnetycznych związanych z użytkowaniem nasobnych urządzeń działających w technologii Internetu Rzeczy
Characteristics of electromagnetic emissions related to the use of wearable devices operating within the Internet of Things technology
Autorzy:
Zradziński, Patryk
Karpowicz, Jolanta
Gryz, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2202814.pdf
Data publikacji:
2021
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
urządzenia łączności bezprzewodowej
inżynieria środowiska
inżynieria biomedyczna
pole elektromagnetyczne
symulacje numeryczne
szybkość pochłaniania właściwego energii
wireless communication devices
environmental engineering
biomedical engineering
electromagnetic field
numerical simulations
specific energy absorption rate
Opis:
Internet Rzeczy (IoT) jest coraz powszechniej wykorzystywaną technologią w przemyśle, w tzw. inteligentnych miastach i domach czy w monitoringu stanu zdrowia. Artykuł prezentuje charakterystykę emisji elektromagnetycznych różnych technologii łączności bezprzewodowej wykorzystywanych w IoT (WiFi, Bluetooth, RFID, Zig-Bee, sieci komórkowe itp.). Przedstawiono w nim również kryteria i metody oceny zawodowych zagrożeń elektromagnetycznych związanych z użytkowaniem takich urządzeń.
The Internet of Things (IoT) is an increasingly popular technology in industry, so-called smart cities and homes, or health monitoring. The article presents the characteristics of electromagnetic emissions of various wireless communication technologies used in IoT (WiFi, Bluetooth, RFID, Zig-Bee, cellular networks, etc.). It also presents criteria and methods for the assessment of occupational electromagnetic hazards related to the use of such devices.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2021, 5; 17-21
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Environmental safety aspects of using UHF RFID systems in hospitals
Aspekty środowiskowego bezpieczeństwa wykorzystania systemów UHF RFID w szpitalach
Autorzy:
Zradziński, Patryk
Karpowicz, Jolanta
Gryz, Krzysztof
Suarez, Oscar J.
Trillo, Angeles M.
Hernandez, Jose A.
Miguel-Bilbao de, Silvia
Suarez, Samuel D.
Celaya-Echarri, Mikel
Azpilicueta, Leyre
Falcone, Francisco
Ramos, Victoria
Powiązania:
https://bibliotekanauki.pl/articles/2146754.pdf
Data publikacji:
2020
Wydawca:
Indygo Zahir Media
Tematy:
biomedical engineering
environmental engineering
occupational exposure
public health
AIMD
Internet of things
inżynieria biomedyczna
inżynieria środowiska
narażenie zawodowe
zdrowie publiczne
internet rzeczy
Opis:
Various applications of Radio Frequency IDentification (RFID) technology in the medical environment are characterised. The electromagnetic field (EMF) emitted by RFID handheld readers (RFID guns) is characterised and evaluated with respect to humans exposure metrics – the strength of the electric field affecting anyone present near various UHF (ultra-high frequency) RFID guns and the specific absorption rate (SAR) values in their body. UHF RFID systems are the most popular of such systems used in hospitals. The performed studies indicate that the EMF exposure level near the RFID gun antenna and SAR values (a measure of the thermal effects of EMF exposure) caused by exposure from the RFID reader may exceed the limits of the electric field and SAR issued by international guidelines or legislation. Potentially excessive exposure to EMF emitted by UHF RFID readers is not limited to the user of the device, but may also apply to patients or bystanders. Only UHF RFID guns with an EMF emission lower than 1 W may be considered as an insignificant source of human exposure. The use of readers with a radiated power exceeding 1 W requires the evaluation of the EMF level using measurements, and also the evaluation of SAR by numerical modelling in the case of their use in close proximity to humans. In all cases, insufficient electromagnetic immunity of electronic devices (including medical implants) should be considered near RFID guns at least up to half of the reading range away from the RFID reader. The electromagnetic hazards related to the use of RFID guns may be limited by relevant preventive measures, as shown in this paper, together with the principles of an in-situ evaluation of electromagnetic hazards near the UHF RFID guns.
Scharakteryzowano różne zastosowania technologii identyfikacji radiowej (RFID) w środowisku medycznym. Pole elektromagnetyczne emitowane przez ręczne czytniki RFID (RFID guns) zostało scharakteryzowane i ocenione w odniesieniu do miar narażenia ludzi – natężenia pola elektrycznego oddziałującego na osoby znajdujące się w pobliżu różnych czytników RFID UHF (ultrawysokiej częstotliwości) i współczynnika SAR w ich ciele. System UHF RFID jest najpopularniejszym z systemów RFID użytkowanych m.in. w szpitalach. Przeprowadzone badania wskazują, że poziom ekspozycji na pole elektromagnetyczne w pobliżu anteny ręcznego czytnika RFID i wartości SAR (miara skutków termicznych oddziaływania pola elektromagnetycznego) spowodowane tą ekspozycją mogą przekraczać limity, opublikowane w zleceniach międzynarodowych lub przepisach. Nadmierna ekspozycja na pole elektromagnetyczne emitowane przez czytniki RFID UHF może dotyczyć nie tylko użytkownika urządzenia, ale również pacjenta lub osoby postronnej. Tylko ręczne czytniki RFID UHF o emisji pola elektromagnetycznego poniżej 1 W można uznać za nieistotne źródło narażenia ludzi. Korzystanie z czytników o mocy przekraczającej 1 W wymaga oceny poziomu pola elektromagnetycznego za pomocą pomiarów, a również oceny SAR za pomocą modelowania numerycznego w przypadku ich użycia w bezpośredniej bliskości ludzi. We wszystkich przypadkach niewystarczającą odporność elektromagnetyczną urządzeń elektronicznych (w tym implantów medycznych) należy rozważyć w pobliżu czytników RFID co najmniej do odległości od czytnika RFID równej połowie jego zasięgu odczytu. Zagrożenia elektromagnetyczne związane z używaniem ręcznych czytników RFID mogą być ograniczone przez odpowiednie środki ochronne, jak pokazano w tym artykule, wraz z zasadami oceny zagrożeń elektromagnetycznych in-situ w pobliżu ręcznych czytników UHF RFID.
Źródło:
Inżynier i Fizyk Medyczny; 2020, 9, 2; 133--140
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena elektromagnetycznych okoliczności użytkowania nasobnych lokalizatorów
Evaluation of the electromagnetic circumstances of the use of wearable locators
Autorzy:
Zradziński, Patryk
Karpowicz, Jolanta
Gryz, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/23352065.pdf
Data publikacji:
2022
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
pole elektromagnetyczne
skutki bezpośrednie narażenia
skutki pośrednie narażenia
nauki o zdrowiu
inżynieria biomedyczna
inżynieria środowiska
zagrożenia elektromagnetyczne
electromagnetic field
direct effects of exposure
indirect effects of exposure
biomedical engineering
environmental engineering
electromagnetic hazards
Opis:
Lokalizatory, czyli nasobne urządzenia ułatwiające zdalne (elektromagnetyczne) monitorowanie miejsca pobytu lub odnalezienie człowieka, są wykorzystywane w rozwiązaniach poprawiających bezpieczeństwo ludzi w trudnym lub niebezpiecznym terenie. W związku z tym, że lokalizatory mają za zadanie poprawienie bezpieczeństwa ludzi w razie zagrożenia bezpieczeństwa, a nawet życia użytkownika, parametry emitowanego przez nie pola elektromagnetycznego są w znacznym stopniu zdeterminowane spodziewanymi dla takiego zdarzenia okolicznościami technicznymi i parametrami dielektrycznymi środowiska w takim miejscu. Wykonane badania wykazały, że w otoczeniu nasobnych lokalizatorów (takich jak lokalizatory lawinowe, lampy górnicze wyposażone w górniczy nadajnik lokacyjny czy radiotelefony) należy rozpoznać, czy występuje przestrzeń pola elektromagnetycznego o poziomie, przy którym stosuje się systemowe działania związane z ochroną przed zagrożeniami elektromagnetycznymi (tzn. jest tam pole elektromagnetyczne stref ochronnych, o zasięgach zależnych od rodzaju urządzenia i parametrów jego pracy), a przy radiotelefonach pracujących z mocą 4 W lub więcej należy również rozpoznać, czy występuje przestrzeń pola elektromagnetycznego strefy niebezpiecznej (narażenie niebezpieczne). Ze względów funkcjonalnych (konieczność emisji pola elektromagnetycznego w pobliżu ciała pracownika) całkowita eliminacja zagrożeń elektromagnetycznych związanych z użytkowaniem nasobnych lokalizatorów jest niemożliwa. Zaproponowane w niniejszym opracowaniu środki ochronne umożliwiają znaczne ograniczenie omawianych zagrożeń elektromagnetycznych podczas użytkowania lokalizatorów nasobnych.
Locators, i.e. wearable remote (electromagnetic) assisting devices, provide ability to supervise the places to stay or to find a person, they are in solutions that improve the safety of people in harsh or dangerous environment. Due to the fact that the locators are designed to improve the safety of people in the event of a hazardous or even life danger of the user, the parameters of the electromagnetic field emitted by them are determined by the technical circumstances and dielectric parameters of the environment that may occur where the active use of locators is expected. Based on the results of performed studies in the vicinity of wearable locators (such as avalanche locators, mining lamps equipped with a mining locating transmitters, or radiotelephones) it is necessary to recognize whether there is an electromagnetic field space with a level at which systemic measures related to protection against electromagnetic hazards are applied (i.e. with ranges depending on the type of device and its operating parameters), and in the case of radiotelephones operating with a power of 4 W or higher, also whether there is also an electromagnetic field space of the dangerous (conditional) exposure. For functional reasons (the need to emit an electromagnetic field near the worker’s body), complete elimination of electromagnetic hazards related to the use of wearable locators is impossible. The protective measures proposed in this paper make it possible to significantly reduce the discussed electromagnetic hazards during the use of wearable locators.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2022, 4 (114); 65--78
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Podstawy oceny elektromagnetycznych okoliczności użytkowania nasobnych urządzeń Internetu Rzeczy
Principles of evaluating electromagnetic aspects of using wearable Internet of Things devices
Autorzy:
Zradziński, Patryk
Gryz, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/23352060.pdf
Data publikacji:
2022
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
pole elektromagnetyczne
skutki bezpośrednie narażenia
skutki pośrednie narażenia
współczynnik pochłaniania właściwego energii (SAR)
nauki o zdrowiu
inżynieria biomedyczna
inżynieria środowiska
electromagnetic field
direct effects of exposure
indirect effects of exposure
specific energy absorption rate (SAR)
health sciences
biomedical engineering
environmental engineering
Opis:
Objęcie poruszających się obiektów nadzorem systemu Internetu Rzeczy (IoT, ang. Internet of Things) wymaga zastosowania bezprzewodowej transmisji danych, a często również energii, z wykorzystaniem propagacji energii elektromagnetycznej w powietrzu. Rozwiązania takie są coraz powszechniej wdrażane w wielu gałęziach gospodarki (np. przemyśle wytwórczym, budownictwie, transporcie czy rolnictwie, nauce, służbie zdrowia, a nawet w służbach mundurowych czy działaniach militarnych). Pole elektromagnetyczne (pole-EM) jest w takich systemach emitowane przez moduły radiowe urządzeń wyposażone w anteny nadawcze. Ze względu na elektromagnetyczne okoliczności związane z użytkowaniem urządzeń nasobnych IoT, właściwe jest rozróżnienie ich pod względem rodzaju źródła zasilania modułów radiowych na: (1) autonomiczne urządzenia wyposażone w źródło zasilania modułów radiowych, wykorzystujących różne standardy radiokomunikacji, np. Bluetooth, Wi-Fi, publiczne systemy telefonii komórkowej i podobne oraz (2) urządzenia niezawierające źródła zasilania, zasilane z zewnątrz energią przekazaną bezprzewodowym łączem elektromagnetycznym, np. znaczniki pasywne RFID. Celem publikacji jest scharakteryzowanie okoliczności i skutków oddziaływania w środowisku pracy pola-EM wytwarzanego ze względu na zamierzone właściwości funkcjonalne różnorodnych nasobnych urządzeń wykorzystywanych w systemach IoT. Scharakteryzowano nasobne urządzenia systemów IoT i wykorzystywane w nich różnorodne technologie radiokomunikacyjne, rozpatrywane ze względu na pole-EM emitowane podczas ich użytkowania i skutki jego oddziaływania w środowisku pracy. Omówiono wymagania prawne dotyczące oceny i ograniczania niepożądanych skutków oddziaływania pola-EM na pracujących i materialne środowisko pracy, a także środki ochronne służące ich ograniczaniu, stosowane w ramach wymagań prawa pracy.
Making movable objects a part of the Internet of Things (IoT) system requires the use of wireless transmission of data, and often also energy when harvesting electromagnetic energy in the air. Such solutions are increasingly commonly implemented in many sectors of the economy (e.g. manufacturing industry, construction, transport and agriculture, science, healthcare, and even in the uniformed services or military operations). The electromagnetic field (EMF) in such systems is emitted by radio modules of devices equipped with transmitting antennas. Due to the electromagnetic circumstances related to the use of IoT wearable devices, it is appropriate to distinguish them in terms of the type of power source for radio modules into: (1) autonomous devices equipped with a power source for radio modules, using various radiocommunication standards, e.g. Bluetooth, Wi-Fi, public mobile telecommunication systems, so on; and (2) devices without a power source, powered externally using energy transmitted via a wireless electromagnetic link, e.g. passive RFID tags. The aim of the publication is to characterise the circumstances and effects of EMF exposure in the work environment due to the intended functional properties of various wearable devices used in IoT systems. The wearable IoT systems devices and the various radiocommunication technologies used in them are characterised, considering the EMF emitted during their use, and the effects of this in the work environment. The paper also discusses the legal requirements for assessing and reducing the undesirable effects of EMF exposure on workers and the material objects of work environment, as well as protective measures to limit them, as applied within the requirements of the labour law.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2022, 4 (114); 7--38
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
2,3,7,8-Tetrachlorodibenzo-p-dioksyna : metoda oznaczania w powietrzu na stanowiskach pracy z zastosowaniem chromatografii gazowej ze spektrometrią mas
2,3,7,8-Tetrachlorodibenzo-p-dioxin : determining in workplace air with gas chromatography – mass spectrometry
Autorzy:
Zieliński, Marek
Twardowska, Ewa
Kucharska, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/137561.pdf
Data publikacji:
2019
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
2,3,7,8-TCDD
metoda oznaczania
metoda chromatografii gazowej
powietrze na stanowiskach pracy
nauki o zdrowiu
inżynieria środowiska
determination method
gas chromatography
workplace air
health sciences
environmental engineering
Opis:
Polichlorowane dibenzo-p-dioksyny (PCDD), w tym 2,3,7,8-tetrachlorodibenzo-p-dioksyna (TCDD), należą do grupy związków chemicznych zwanych trwałymi zanieczyszczeniami organicznymi (TZO), (ang. persistent organic pollutants, POPs). Trwałe zanieczyszczenia organiczne są wykrywane w śladowych ilościach prawie we wszystkich przedziałach środowiska globalnego ekosystemu. Około 90% dioksyn dostaje się do organizmu człowieka z pożywieniem. Związki z grupy trwałych zanieczyszczeń organicznych gromadzą się w tkance tłuszczowej, są wolno metabolizowane i szkodliwe, nawet po długim czasie od początkowego narażenia. Dioksyny są związkami, które sukcesywnie i powoli kumulują się w organizmie. Wpływają na wiele reakcji immunologicznych, które przebiegają pod postacią przewlekłych alergii skórnych. Głównym miejscem działania dioksyn są interakcje z gruczołami wydzielania wewnętrznego: tarczycą, gonadami żeńskimi i męskimi, endometrium macicy oraz z nadnerczami, w których są wytwarzane hormony steroidowe. Dioksyny mogą powodować zaburzenia gospodarki hormonalnej organizmu poprzez indukcję receptora węglowodorów aromatycznych (AhR). Mechanizm patogennego oddziaływania TCDD z tkankami i komórkami często nie jest w pełni poznany, jednak na pewno w te mechanizmy jest włączony stres oksydacyjny, a także jakościowe i ilościowe modyfikacje receptorów komórkowych lub białek docelowych czy immunomodulacja. Celem pracy było opracowanie i walidacja czułej metody oznaczania 2,3,7,8-TCDD w środowisku pracy w zakresie 1/10 ÷ 2 wartości najwyższego dopuszczalnego stężenia (NDS). Opracowana metoda polega na: adsorpcji TCDD na piance poliuretanowej, ekstrakcji zatrzymanego związku toluenem i analizie chromatograficznej otrzymanego roztworu przy zastosowaniu wysokorozdzielczego spektrometru mas. Wyznaczony współczynnik desorpcji TCDD z pianki poliuretanowej za pomocą toluenu, wynosi 83,1%. Odpowiedź detektora mas ma charakter liniowy (r = 0,998) w zakresie stężeń 18 ÷ 360 pg/ml, co odpowiada zakresowi 1,8 ÷ 36 mg/m3 (1/10 ÷ 2 wartości NDS) dla próbki powietrza o objętości 10 m3. Granica oznaczalności (LOQ) tej metody wynosi 10,26 pg/ml. Zastosowanie do analizy kolumny DB-5MS pozwala na selektywne oznaczenie TCDD w obecności: toluenu, nonanu oraz innych związków współwystępujących. Opisana metoda analityczna charakteryzuje się dobrą precyzją oraz dokładnością i spełnia wymagania zawarte w normie europejskiej PN-EN 482 dla procedur dotyczących oznaczania czynników chemicznych. Opracowana metoda oznaczania TCDD w powietrzu na stanowiskach pracy została zapisana w postaci procedury analitycznej, którą zamieszczono w załączniku. Zakres tematyczny artykułu obejmuje zagadnienia zdrowia oraz bezpieczeństwa i higieny środowiska pracy będące przedmiotem badań z zakresu nauk o zdrowiu oraz inżynierii środowiska.
PCDD are environmental pollutants, called Persistent Organic Pollutants (POPs). Their trace amounts can be found in almost all the spectrum of global ecosystems. Nearly 90% of human exposure to dioxins comes from food. POPs compounds, which gather in fatty tissues, are slowly metabolized and remain harmful even after a relatively long time after exposure. Dioxins enter the human body with food and accumulate in fat-rich tissues. Dioxins gradually and slowly accumulate in the body. They trigger a number of immunological reactions, which take the form of chronic skin allergies. They can disturb the body hormone economy through induction of the aromatic hydrocarbon receptor. The aim of the work was to develop and validate a sensitive method of determining 2,3,7,8-TCDD in the working environment in the range of 1/10–2 MAC values. The developed method consists in adsorption of TCDD on polyurethane foam followed by extraction of the retained compound with toluene and chromatographic analysis using a high-resolution mass spectrometry. The determined TCDD desorption coefficient from polyurethane foam with 20% acetone in toluene is 83.1%. The response of the mass detector is linear (r = 0.998) in the concentration range of 18–360 pg/ml, which corresponds to the range of 1.8–36 mg/m³ (1/10–2 MAC) for an air sample of 10 m³ . The limit of quantification (LOQ) of this method is 10.26 pg/ml. Using a DB-5MS capillary column makes a selective determination of TCDD in the presence of toluene, nonane and other co-existing compounds possible. The developed method is characterized by good precision and accuracy and meets the requirements of European Standard PN-EN 482 for procedures on determining chemical agents. The developed method of determining TCDD has been recorded as an analytical procedure (see appendix). This article discusses the problems of occupational safety and health, which are covered by health sciences and environmental engineering.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2019, 3 (101); 139-149
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Etylenodiamina : metoda oznaczania w powietrzu na stanowiskach pracy z zastosowaniem wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną
Ethylenediamine : determination in workplace air with high performance liquid chromatography – spectrophotometric technique
Autorzy:
Zieliński, Marek
Twardowska, Ewa
Bonczarowska, Marzena
Powiązania:
https://bibliotekanauki.pl/articles/138468.pdf
Data publikacji:
2019
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
etylenodiamina
metoda oznaczania
wysokosprawna chromatografia cieczowa
powietrze na stanowiskach pracy
nauki o zdrowiu
inżynieria środowiska
ethylenediamine
determination method
high performance liquid chromatography
workplace air
health sciences
environmental engineering
Opis:
Etylenodiamina (EDA) jest gęstą, bezbarwną cieczą o słabym amoniakalnym zapachu. Jest stosowana głównie jako półprodukt do otrzymywania: związków chelatujących, fungicydów, barwników, wosków syntetycznych, żywic poliamidowych i formaldehydowo-mocznikowych, środków antykorozyjnych oraz jako emulgator i stabilizator gumy. Etylenodiamina wykazuje działanie drażniące na błony śluzowe: górnych dróg oddechowych, oczu i skóry. Narażenie zawodowe na ten związek może być również powodem wystąpienia reakcji alergicznych, a nawet astmy. Etylenodiamina nie jest klasyfikowana jako czynnik rakotwórczy dla ludzi. Celem pracy było opracowanie i walidacja czułej metody umożliwiającej oznaczenie stężeń tego związku na poziomie 1/10 NDS zgodnie z wymaganiami normy europejskiej PN-EN 482. Badania wykonano z zastosowaniem wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS). Wszystkie analizy chromatograficzne wykonano przy zastosowaniu kolumny Supelcosil LC-18 (150 × 3 mm, 5 µm) eluowanej mieszaniną acetonitrylu i wody (62:38 v/v). Zasada metody polega na: zatrzymaniu par etylenodiaminy na żelu krzemionkowym nasączonym kwasem siarkowym, ekstrakcji mieszaniną acetonitrylu i wody (62:38 v/v), przeprowadzeniu wyekstrahowanego związku w pochodną w reakcji z chloromrówczanem 9-fluorenylometylu i chromatograficznym oznaczeniu powstałego związku. Metoda jest liniowa (r = 0,9994) w zakresie stężeń 0,1 ÷ 2 µg/ml, co odpowiada zakresowi 2 ÷ 40 mg/m3 dla próbki powietrza o objętości 10 l. Obliczone granice wykrywalności (LOD) i oznaczania ilościowego (LOQ) wynoszą odpowiednio 0,04 i 0,13 μg/ml. Wydajność ekstrakcji etylenodiaminy z żelu wynosi 86%, a pobrane próbki przechowywane w chłodziarce zachowują trwałość przez 10 dni. Opracowana metoda charakteryzuje się dobrą precyzją oraz dokładnością i spełnia wymagania normy PN-EN 482. Metoda oznaczania etylenodiaminy została zapisana w postaci procedury analitycznej, którą zamieszczono w załączniku. Zakres tematyczny artykułu obejmuje zagadnienia zdrowia oraz bezpieczeństwa i higieny środowiska pracy będące przedmiotem badań z zakresu nauk o zdrowiu oraz inżynierii środowiska.
Ethylenediamine (EDA) is a colorless, viscous liquid with ammonia-like odor. It is used as an intermediate in manufacturing chelating agents (EDTA), fungicide, poliamide and formaldehyde-urea resins, surfactants, corrosion inhibitors, emulsifying agents and stabiliser of rubber products. EDA may cause irritation of the upper respiratory tract, eye and skin. Occupational exposure to EDA may lead to allergic reactions and asthma. EDA is not classified as carcinogenic to humans. The aim of this study was to develop and validate a sensitive method for determining hydrazine concentrations in workplace air in the range from 1/10 to 2 MAC values, in accordance with the requirements of Standard No. PN-EN 482. The study was performed using a liquid chromatograph with spectrophotometric detection. All chromatographic analyses were performed with a Supelcosil LC-18 (150 × 3 mm, 5 µm) analytical column, which was eluted with a mixture of acetonitrile and water (6:4 v/v). The method is based on the collection of EDA on silica gel impregnated with sulfuric acid, extraction with a mixture of acetonitrile and water (62:38 v/v), derivatization of extracted compound with 9-fluorenylmethyl chloroformate and chromatographic determination of the resulting solution with HPLC. The method is linear (r = 0.9994) within the investigated working range 0.1–2 μg/ml (2–40 mg/m3 for a 10-L air sample). The calculated limit of detection (LOD) and limit of quantification (LOQ) were 0.04 μg/ml and 0.13 μg/ml, respectively. The average extraction efficiency of EDA from silica gel was 86% and samples stored in a refrigerator are stable for 10 days. The analytical method described in this paper enables determination of EDA in workplace air. The method is precise, accurate and it meets the criteria for procedures for measuring chemical agents listed in Standard No. PN-EN 482. The method can be used for assessing occupational exposure to EDA and associated risk to workers’ health. The developed method of determining EDA has been recorded as an analytical procedure (see Appendix). This article discusses the problems of occupational safety and health, which are covered by health sciences and environmental engineering.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2019, 1 (99); 29-44
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fenylohydrazyna : metoda oznaczania na stanowiskach pracy z zastosowaniem wysokosprawnej chromatografii cieczowej
Phenylhydrazine : determination in workplace air with high pressure liquid chromatography
Autorzy:
Zieliński, Marek
Bonczarowska, Marzena
Twardowska, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/138435.pdf
Data publikacji:
2020
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
fenylohydrazyna
metoda oznaczania
metoda wysokosprawnej chromatografii cieczowej
powietrze na stanowiskach pracy
nauki o zdrowiu
inżynieria środowiska
phenylhydrazine
determination method
high performance liquid chromatography
workplace air
health sciences
environmental engineering
Opis:
Fenylohydrazyna w temperaturze pokojowej występuje w postaci bezbarwnej oleistej cieczy o słabym, aromatycznym zapachu. Jest stosowana w syntezie organicznej jako silny środek redukujący lub jako półprodukt przy produkcji innych związków chemicznych (m.in. barwników i leków). Wykorzystuje się ją również jako odczynnik chemiczny służący do identyfikacji aldehydów i ketonów oraz identyfikacji i określania konfiguracji cukrów. Do organizmu człowieka fenylohydrazyna może dostawać się drogą inhalacyjną, pokarmową lub na drodze bezpośredniego kontaktu ze skórą. Gdy zostanie wchłonięta, szybko wiąże się z hemoglobiną. Toksyczne działanie fenylohydrazyny polega głównie na uszkadzaniu czerwonych krwinek skutkującym anemią hemolityczną i w konsekwencji uszkodzeniem śledziony i wątroby. Fenylohydrazyna może również działać uczulająco oraz powodować kontaktowe zapalenia skóry. Celem prac badawczych było opracowanie i walidacja czułej metody oznaczania stężeń fenylohydrazyny w środowisku pracy w zakresie 1/10 ÷ 2 NDS zgodnie z wymogami normy PN-EN 482. Badania wykonano techniką wysokosprawnej chromatografii cieczowej (HPLC) przy zastosowaniu chromatografu cieczowego Waters Alliance 2695 wyposażonego w pompę poczwórną, kolumnę analityczną Supelcosil LC-18 (150 × 2,1 mm, 5 µm), detektor spektrofotometryczny (UV-VIS) i autosampler. Metoda polega na: adsorpcji fenylohydrazyny na żelu krzemionkowym pokrytym 0,1 mol/l kwasem solnym, ekstrakcji zatrzymanego związku mieszaniną acetonitrylu i wody, derywatyzacji fenylohydrazyny acetonem oraz oznaczaniu powstałej pochodnej metodą HPLC. Współczynnik desorpcji fenylohydrazyny z żelu krzemionkowego pokrytego HCl wynosi 0,96. Metoda jest liniowa (r = 0,9996) w zakresie stężeń 11,4 ÷ 228 µg/ml, co odpowiada zakresowi 0,19 ÷ 3,80 mg/m³ dla próbki powietrza o objętości 180 l. Granica oznaczalności (LOQ) wynosi 0,027 µg/ml. Opisana metoda analityczna umożliwia oznaczenie w powietrzu na stanowiskach pracy stężenia fenylohydrazyny równego 0,19 mg/m³ (1/10 wartości NDS). Metoda charakteryzuje się dobrą precyzją i dokładnością i spełnia wymagania normy PN-EN 482 dla procedur dotyczących oznaczania czynników chemicznych. Opracowana metoda oznaczania fenylohydrazyny w powietrzu na stanowiskach pracy została zapisana w postaci procedury analitycznej, którą zamieszczono w załączniku. Zakres tematyczny artykułu obejmuje zagadnienia zdrowia oraz bezpieczeństwa i higieny środowiska pracy będące przedmiotem badań z zakresu nauk o zdrowiu oraz inżynierii środowiska.
Phenylhydrazine is colorless oily liquid with a weak aromatic odor. Phenylhydrazine is used in organic synthesis as a strong reducing agent or as an intermediate in the synthesis of other chemical compounds (in the production of dyes and medicines). It is also used as a chemical reagent to identify aldehydes and ketones as well as to identify and determine the configuration of sugars. Phenylhydrazine may enter the human body by inhalation, ingestion or by direct contact with the skin. Adsorbed, it binds quickly to hemoglobin. The toxic effect of phenylhydrazine is to damage red blood cells. This may cause hemolytic anemia and, consequently, damage to the spleen and liver. This compound can also be sensitizing and cause contact dermatitis. The aim of this study was to develop and validate a sensitive method for the determination of phenylhydrazine concentrations in workplace air in the range from 1/10 to 2 MAC values, in accordance with the requirements of the standard PN-EN 482. Studies was performed using high-performance liquid chromatography (HPLC) technique. A Waters Alliance 2695 liquid chromatograph equipped with a quaternary pump, Supelcosil C-18 (150 × 2.1 mm; 5 μm) analytical column, spectrophotometric detector (UV-VIS), and autosampler, was used for chromatographic separations. The method is based on the adsorption of phenylhydrazine on silica gel coated with 0,1 M/l hydrochloric acid, extraction of phenylhydrazine with mixture of acetonitrile and water, derivatization of phenylhydrazine with acetone and determination of resulted derivative by means of HPLC method. Recovery of phenylhydrazine from silica gel coated with HCl amounted to 0,90. Method is linear (r = 0.9996) within the investigated working range 11,4 ÷ 228 mg/ml, which is equivalent to air concentrations from 0.19 to 3.80 mg/m³ for a 180 L air sample. Limit of quantification amounted to 0.027 μg/ml. Analytical method described in this paper enables selective determination of phenylhydrazine in workplace atmosphere from 0.19 mg/m³ (1/10 MAC value). The method is characterized by good precision and accuracy and meets the criteria for the performance of procedures for the measurement of chemical agents, listed in EN 482:2006. The method may be used for the assessment of occupational exposure to phenylhydrazine and the associated risk to workers’ health. The method for determining phenylhydrazine has been recorded in the form of an analytical procedure (see appendix). This article discusses the problems of occupational safety and health, which are covered by health sciences and environmental engineering.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2020, 3 (105); 143-158
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pentan-1-ol i pozostałe izomery pentanolu : metoda oznaczania w powietrzu na stanowiskach pracy z zastosowaniem chromatografii gazowej z detekcją płomieniowo-jonizacyjną GC-FID
Pentane-1-ol and its isomers : determination in workplace air with GC with Flame Ionization Detector (GC-FID)
Autorzy:
Zieliński, Marek
Twardowska, Ewa
Kucharska, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/138274.pdf
Data publikacji:
2019
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
pentanol
alkohol amylowy
metoda oznaczania
metoda chromatografii gazowej
FID
powietrze na stanowiskach pracy
nauki o zdrowiu
inżynieria środowiska
amyl alcohol
determination method
gas chromatography
workplace air
health sciences
environmental engineering
Opis:
Pentan-1-ol (C5H11OH) to organiczny związek chemiczny z grupy nasyconych monohydroksylowych alkoholi alifatycznych. Znanych jest 8 izomerów pentanolu: pentan-1-ol, pentan-2-ol (nr CAS: 6032-29-7), pentan-3-ol (nr CAS: 584-02-1), 2-metylobutan-1-ol (nr CAS: 137-32-6), 3-metylobutan-1-ol (nr CAS: 123-51-3), 2-metylobutan-2-ol (nr CAS: 75-85-4), 3-metylobutan-2-ol (nr CAS: 598-75-4) i 2,2-dimetylopropan-1-ol (nr CAS: 75-84-3). Izomery pentanolu wykazują właściwości chemiczne, które są charakterystyczne dla alkoholi alifatycznych. Są one otrzymywane przez hydratację izomerów pentenu lub hydrolizę chloropentanów. Wykorzystywane są jako rozpuszczalniki: tłuszczów, żywic i wosków. Pentan-1-ol wchłania się do organizmu człowieka poprzez: drogi oddechowe, skórę i przewód pokarmowy. Objawy zatrucia ostrego to najczęściej: łzawienie oczu, zaczerwienienie spojówek, podrażnienie błony śluzowej nosa i gardła. Przy większych stężeniach mogą wystąpić: ból i zawroty głowy, mdłości, wymioty, biegunka, stan pobudzenia (delirium), zaburzenia świadomości, śpiączka. Może również wystąpić arytmia i zaburzenia oddechowe. Skażenie skóry może spowodować jej zaczerwienienie i pieczenie oraz objawy, które występują przy zatruciu drogą inhalacyjną. Skażenie oczu ciekłą substancją wywołuje: ból, pieczenie oczu, zaczerwienienie spojówek, z ryzykiem długotrwałych i trwałych zmian. Wypicie bardzo małej ilości pentanolu może wywoływać: nudności, wymioty oraz biegunkę. Przy powtarzającym się kontakcie ciekłej substancji ze skórą mogą wystąpić jej wysuszenie i stany zapalne, natomiast długotrwałe narażenie skóry na substancję o dużym stężeniu może prowadzić do zmian w układzie nerwowym. Celem pracy było opracowanie i walidacja czułej metody oznaczania 8 izomerów pentanolu w środowisku pracy w zakresie od 1/10 do 2 wartości najwyższego dopuszczalnego stężenia (NDS). Do oznaczenia izomerów pentanolu zastosowano metodę chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID). Postanowiono opracować metodę zapewniającą oznaczalność na poziomie co najmniej 1/10 NDS. Dalsze rozważania możliwości oznaczania tej substancji w powietrzu oparto na wcześniej opracowanych metodach analitycznych. Zastosowanie kolumny kapilarnej HP-5 umożliwia selektywne oznaczenie pentan-1-olu w obecności: disiarczku węgla, metanolu oraz innych związków współwystępujących. Odpowiedź detektora na analizowane stężenia pentan-1-olu ma charakter liniowy (r2 = 0,9998) w zakresie stężeń 10 ÷ 2 000 μg/ml, co odpowiada zakresowi 1 ÷ 200 mg/m3 (0,01 ÷ 2 wartości NDS) dla próbki powietrza o objętości 10 l. Granica wykrywalności tej metody wynosi 0,026 μg/ml. Opracowana metoda charakteryzuje się dobrą precyzją oraz dokładnością i spełnia wymagania zawarte w normie europejskiej PN-EN 482 dla procedur dotyczących oznaczania czynników chemicznych. Opracowaną metodę oznaczania pentan-1-olu i pozostałych izomerów zapisano w postaci procedury analitycznej, którą zamieszczono w załączniku. Zakres tematyczny artykułu obejmuje zagadnienia zdrowia oraz bezpieczeństwa i higieny środowiska pracy będące przedmiotem badań z zakresu nauk o zdrowiu oraz inżynierii środowiska.
Amyl alcohol (pentan-1-ol) – C5 H12O or C5 H11OH – is an organic chemical compound from the group of saturated monohydric aliphatic alcohols. There are 8 known isomers of pentanol: pentan-1-ol (CAS:71-41- 0), pentan-2-ol (CAS: 6032-29-7), pentan-3-ol (CAS: 584-02-1), 2-metylobutan-1-ol (CAS: 137-32-6), 3-metylobutan-1-ol (CAS: 123-51-3), 2-metylobutan- 2-ol (CAS: 75-85-4), 3-metylobutan-2-ol (CAS: 598-75-4) i 2,2-dimetylopropan-1-ol (CAS: 75-84- 3). All of them are commonly referred to as amyl alcohols. Pentanol isomers exhibit chemical properties characteristic of aliphatic alcohols, they are obtained by hydration of pentene isomers, hydrolysis of chloropentanes or by reaction of butene and carbon monoxide isomers. They are used as solvents for fats, resins and waxes. Pentan-1-ol is absorbed into the human body through the respiratory tract, skin, gastrointestinal tract. Symptoms of acute intoxication are usually tearing eyes, redness of the conjunctiva, irritation of the mucous membrane of the nose and throat. In higher concentrations it may cause headache, dizziness, nausea, vomiting, diarrhea, delirium, disturbances of consciousness, coma. Arrhythmia and respiratory disorders may cause redness and burning, as well as symptoms such as inhalation poisoning, eye contamination with liquid substance causes pain, burning of the eyes, redness of the conjunctiva, with the risk of long-lasting and permanent changes. Repeated skin contact with the liquid substance may cause its drying and inflammation. It is suggested that long-term exposure of the skin to the substance at high concentration may lead to changes in the nervous system. The aim of this study was to develop and validate a sensitive method of determining 8 pentan-1-ol isomers in the working environment in the range from 1/10 to 2 of the MAC values. The gas chromatography method with a flame ionization detector (GC-FID) was used to determine pentan-1-ol and its isomers. It was decided to develop a method that ensures the determination of at least 1/10 of the MAC values. Further considerations of the possibility of determining this substance in the air are based on previously developed analytical methods. The use of the HP-5 capillary column enables the selective determination of pentan-1-ol in the presence of carbon disulphide, methanol and other co-existing compounds. The detector’s response to the analyzed pentan-1-ol concentrations is linear (r2 = 0.9998) in the concentration range 10–2000 μg/ml, which corresponds to the range of 1–200 mg/m3 (0.01–2 of the MAC values) for a 10-L air sample. The limit of quantification (LOQ) of this method is 0.026 μg/ml. The developed method is characterized by good precision and accuracy and meets the requirements of Standard No. PN-EN 482 for procedures regarding the determination of chemical agents. The developed method for determining pentan-1-ol has been recorded in the form of an analytical procedure (see Appendix). This article discusses the problems of occupational safety and health, which are covered by health sciences and environmental engineering.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2019, 1 (99); 93-106
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laboratory and numerical experiments into efficient management of VDR filter plants
Autorzy:
Zielina, M.
Dąbrowski, W.
Mackie, R. I.
Powiązania:
https://bibliotekanauki.pl/articles/206922.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
filters
environmental engineering
waste management
deep bed filtration
efficient management
numerical experiments
phenomenological modeling
mathematical model
theoretical modelling
filtry
inżynieria środowiska
gospodarowanie odpadami
filtracja wgłębna
sterowanie efektywne
eksperymenty numeryczne
modelowanie fenomenologiczne
model matematyczny
modelowanie teoretyczne
Opis:
runs are achieved when the highest flow through the most recently backwashed filter and the highest available head loss coincide. This rule has previously been published by Dąbrowski, who used a simplified mathematical model of VDR filters developed by Di Bernardo. However, until now no experimental verification of this optimisation approach has been presented. A series of tests were carried out on a laboratory VDR filter plant, using a suspension collected from an industrial sedimentation tank and using alum as a coagulant. The results of the experiments were compared with computations carried out according to a combined unit bed element (UBE)-phenomenological model of deep bed filtration adapted to VDR operation by Mackie and Zhao. It was confirmed that the longest filtration runs did indeed correspond to the pairs of the highest H and q1/qavr. The UBE-phenomenological model of deep bed filtration gave results of computations quite close to experimental results and improved the accuracy of calculations based on the theoretical model by Di Bernardo.
Źródło:
Environment Protection Engineering; 2015, 41, 3; 101-120
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of rheological parameters of the Fore-Sudetic Monocline plastic rocks on the process of drilling boreholes
Wpływ parametrów reologicznych skał plastycznych Monokliny Przedsudeckiej na proces wiercenia otworów wiertniczych
Autorzy:
Zeljaś, Dagmara
Rado, Robert
Kowalska-Kubsik, Iwona
Śliwa, Tomasz
Jamrozik, Aleksandra
Powiązania:
https://bibliotekanauki.pl/articles/219482.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
geologia górnicza i inżynieryjna
inżynieria geotechniczna
ochrona środowiska w górnictwie
wiertnictwo
mining and engineering geology
geotechnical engineering
environmental protection in mining
drilling
Opis:
Plastic rocks can creep, therefore the knowledge of the rheological properties of the drilled formations is an important element of the drilling process and when choosing borehole designs. These properties of plastic formations also influence the way in which appropriate drilling technology and drilling mud properties are selected. The article presents the effect of basic rheological parameters of salt from the Fore-Sudetic Monocline deposit on the drilling of boreholes in the mining area of KGHM Polska Miedź, which in the future can be used as a good drilling practice to improve the safety and efficiency of drilling.The process of drilling in plastic rocks may be hindered. Salt is a plastic rock and in the analyzed rock mass it is deposited at a considerable depth. The caprock exerts big loads on it, beside the tempe-rature in the deposit intensifies the rheological properties of the rock. The creep process causes that the borehole contracts, therefore the knowledge about the rheological properties of the drilled rock is very important for establishing the safe time in which the well may remain uncased. The paper is devoted to the influence of basic rheological parameters of salt bed in the Fore-Sudetic Monocline on the process of drilling of a borehole in the area of KGHM Polska Miedź as these data can be used in drilling practice in the future.
Proces wiercenia otworów przechodzących przez skały plastyczne może powodować utrudnienia. Sól kamienna jest skałą plastyczną, w analizowanym górotworze zalega na znacznej głębokości, poddana jest dużemu obciążeniu wynikającemu z ciężaru nadkładu, niebagatelny jest też wpływ temperatury złoża, dzięki którym w skale spotęgowanie ujawniają się jej właściwości reologiczne. Płynięcie soli powoduje zaciskanie otworu, stąd ważnym elementem w procesie wiercenia jest znajomość własności reologicznych przewiercanej skały, dla ustalenia właściwej technologii wiercenia i wpływ na ustalenie bezpiecznego czasu pozostawienia otworu bez zarurowania. W artykule przedstawiono wpływ podstawowych parametrów reologicznych soli ze złoża Monokliny Przedsudeckiej na proces wiercenia otworu wiertniczego z rejonu KGHM Polska Miedź S.A, które w przyszłości mogą być wykorzystywane w praktyce wiertniczej.
Źródło:
Archives of Mining Sciences; 2019, 64, 2; 297-305
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
How far is environmental engineering from biomedical engineering?
Integracja wiedzy pomiędzy inżynierią środowiska a inżynierią biomedyczną
Autorzy:
Zarzycki, R.
Nawrotek, K.
Powiązania:
https://bibliotekanauki.pl/articles/106509.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
biomedical engineering
environmental engineering
transfer of knowledge
research transfer
transport phenomena
inżynieria biomedyczna
inżynieria środowiska
transfer wiedzy
transfer badań
zjawiska transportu pędu
zjawiska ciepła i masy
Opis:
The development of science, which has been observed in recent years, shows that engineering knowledge and activity are becoming more and more interdisciplinary. Up to the late 80-ties of the previous century, the experience and interest of engineers covered mainly hard sciences that directly followed their education. After this period, the engineering knowledge and solutions proposed in one discipline started to be applied successfully in other domains. This tendency can be seen especially in Biomedical Engineering, which development is based on achievements made in the rest of hard sciences, even if they seem to be as distant as Environmental Engineering.
Rozwój nauki, który obserwuje się w ostatnich latach, wymaga czerpania i integracji wiedzy z różnych jej dziedzin. Do końca lat 80. ubiegłego wieku zainteresowania i praca inżyniera były ściśle związane ze zdobytą przez niego wiedzą i obejmowały głównie nauki ścisłe. Po tym okresie wiedza techniczna oraz rozwiązania zaproponowane w jednej dziedzinie nauki zaczęły być z powodzeniem stosowane w innych. Tendencję tę widać szczególnie w Inżynierii Biomedycznej, której rozwój opiera się na osiągnięciach dokonanych w pozostałych naukach ścisłych, nawet, jeśli wydają się one być tak odległe, jak Inżynierii Środowiska.
Źródło:
Chemistry-Didactics-Ecology-Metrology; 2015, 20, 1-2; 7-18
2084-4506
Pojawia się w:
Chemistry-Didactics-Ecology-Metrology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ftalan dimetylu : metoda oznaczania w powietrzu na stanowiskach pracy
Dimethyl phthalate : determination in workplace air
Autorzy:
Woźnica, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/137307.pdf
Data publikacji:
2019
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
ftalan dimetylu
metoda analityczna
powietrze na stanowiskach pracy
GC-FID
nauki o zdrowiu
inżynieria środowiska
dimethyl phthalate
analytical method
workplace air
health sciences
environmental engineering
Opis:
Ftalan dimetylu (DMP) jest bezbarwną cieczą o słabym zapachu aromatycznym. Substancja ta jest stosowana w przemyśle jako plastyfikator tworzyw sztucznych oraz składnik środków zapachowych do produkcji kosmetyków i detergentów. Celem pracy było opracowanie metody oznaczania frakcji wdychalnej ftalanu dimetylu, która umożliwi oznaczanie jego stężeń w powietrzu na stanowiskach pracy, w zakresie od 1/10 do 2 wartości najwyższego dopuszczalnego stężenia (NDS), czyli 0,5 ÷ 10 mg/m³ . Badania wykonano, stosując chromatograf gazowy (GC) z detektorem płomieniowo-jonizacyjnym (FID), wyposażony w kolumnę kapilarną HP-INNOWAX (60 m × 0,25 mm; 0,15 µm). Metoda polega na: zatrzymaniu ftalanu dimetylu na filtrze z włókna szklanego, ekstrakcji etanolem i analizie chromatograficznej otrzymanego roztworu. Zastosowanie do analizy kolumny HP-INNOWAX pozwala na selektywne oznaczenie ftalanu dimetylu w obecności innych rozpuszczalników. Średnia wydajność odzysku ftalanu dimetylu z filtra wyniosła 98%. Uzyskane krzywe kalibracyjne charakteryzują się dużą wartością współczynnika korelacji (r = 0,9999), który świadczy o liniowości wskazań detektora FID w zakresie stężeń 20 ÷ 400 µg/ml, co odpowiada zakresowi 0,5 ÷ 10 mg/m³ dla próbki powietrza o objętości 120 l. Granica wykrywalności wynosi 0,02 µg/ml, a granica oznaczalności 0,06 µg/ml. Opracowana metoda analityczna umożliwia selektywne oznaczanie stężeń frakcji wdychalnej ftalanu dimetylu w powietrzu na stanowiskach pracy w obecności innych rozpuszczalników o stężeniach od 0,5 mg/m³ (1/10 wartości NDS). Metoda charakteryzuje się dobrą precyzją i dokładnością, spełnia wymagania określone w normie PN-EN 482 dla procedur oznaczania czynników chemicznych. Opracowaną metodę oznaczania ftalanu dimetylu w powietrzu na stanowiskach pracy zapisano w postaci procedury analitycznej, którą zamieszczono w załączniku. Zakres tematyczny artykułu obejmuje zagadnienia zdrowia oraz bezpieczeństwa i higieny środowiska pracy będące przedmiotem badań z zakresu nauk o zdrowiu oraz inżynierii środowiska.
Dimethyl phthalate (DMP) is a colourless liquid with a slight aromatic odour. It is used in industry as a plasticizer of plastics and as an ingredient of fragrances in the production of cosmetics and detergents. Occupational exposure to DMP can occur through inhalation or ingestion. The aim of this study was to validate the method for determining DMP concentration in workplace air in the range from 1/10 to 2 MAC values, in accordance with the requirements of standard PN-EN 482. The study was performed using a gas chromatograph (GC) with a flame ionization detector (FID) equipped with a capillary column HP-INNOWAX (60 m × 0.25 mm, 0.15 µm). This method is based on the sorption of dimethyl phthalate vapours on a glass microfiber filter, desorption with ethanol, and analyzed by GC-FID. The average desorption efficiency of DMP from the filter was 98%. The application of an HP-INNOWAX column makes a selective determination of DMP in the presence of other solvents possible. The measurement range was 0.5 – 10 mg/m³ for a 120-L air sample. Limit of detection: 0.02 µg/ml and limit of quantification: 0.06 µg/ml. The analytical method described in this paper enables selective determination of DMP in workplace air in the presence of other solvents at concentrations from 0.5 mg/m³ (1/10 MAC value). The method is characterized by good precision and accuracy and meets the criteria for the performance of procedures for the measurement of chemical agents, listed in EN 482. The method may be used for the assessment of occupational exposure to DMP and the associated risk to workers’ health. The developed method of determining DMP has been recorded as an analytical procedure (see appendix). This article discusses the problems of occupational safety and health, which are covered by health sciences and environmental engineering.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2019, 2 (100); 127-137
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies