Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "intramedullary nail" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Metal implants in ostheosynthesis - construction solutions, materials and applications
Autorzy:
Hutnik, A.
Świeczko-Żurek, B.
Szumlański, A.
Serbiński, W.
Powiązania:
https://bibliotekanauki.pl/articles/285836.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
metal implants
intramedullary nail
fracture
ostheosynthesis
Opis:
Every day human bones undergo different injuries resulting from public transport accidents, diseases or trauma. Consequently, they cause temporary or constant patients disability or even death. Fractures happen not only to elderly people suffering from osteoporosis, but also more and more frequently to young people, who got some injuries as a result of life style, e.g. doing sports. The desire to enhance the physical well being and quality of patients' life, who got some injury causes constant development of medical devices for osteosynthesis. In the case of complicated fractures, in which plaster treatment is not sufficient, surgical treatment and applying implant are indispensable. The aim of the article is to present two case studies on intramedullary nails. The first one concerns a method of osteosynthesis for a patient, who was injured in an accident. The second one presents the failure of the implanted intramedullary nail. The research included evaluation of the type of fracture and the analysis of microstructure, chemical composition and hardness of the implant materials.
Źródło:
Engineering of Biomaterials; 2012, 15, 115; 7-11
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza funkcjonalna zespolenia śródszpikowego w leczeniu złamań kości piszczelowej
Functional analysis of intramedullary nail in treatment of tibia fracture
Autorzy:
Ryniewicz, A. M.
Otto, M.
Ryniewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/98909.pdf
Data publikacji:
2018
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
zespolenie śródszpikowe
MES
przemieszczenie
odkształcenie
osteosynteza
intramedullary nail
FEM
displacement
deformation
osteosynthesis
Opis:
Wykorzystując gwoździowanie śródszpikowe w leczeniu złamań kości piszczelowej istotne jest, aby zespolenie skutecznie stabilizowało odłamy kostne. Wpływ na ich stabilność ma system ryglowania i sztywność gwoździa śródszpikowego, który wykonany jest z biozgodnych biomateriałów. Celem pracy jest identyfikacja metodą MES przemieszczeń i naprężeń w obciążonym terapeutycznie systemie zespolenia śródszpikowego ze stopu Ti6Al4V ELI, a na tej podstawie określenie mikroodkształcenia w konstrukcji. Wyniki analizy mają związek z mikroruchami odłamów kostnych pobudzające tkankę kostną do ich osteosyntezy.
In intramedullary nailing for tibia fracture treatment, important is effectively stabilizes bone fragments. Their stability depends on the locking system and the stiffness of the intramedullary nail, which is made of biocompatible biomaterials. The purpose of the paper is to identify, based on FEM, displacements and stresses in therapeutically loaded intramedullary nail, made of Ti6Al4V ELI, and on this basis, the determination of microstrain in the construction. The results of the analysis are related to micromovements of bone fragments stimulating bone tissue to their osteosynthesis.
Źródło:
Aktualne Problemy Biomechaniki; 2018, 15; 37-44
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza porównawcza wybranych wariantów stabilizacji złamania kości ramiennej za pomocą gwoździa śródszpikowego
A comparative study of stabilization variants of humeral fracture using an intramedullary nail
Autorzy:
Słowiński, Jakub J.
Kęszycki, Dawid
Kudłacik, Konrad
Powiązania:
https://bibliotekanauki.pl/articles/986638.pdf
Data publikacji:
2019
Wydawca:
Indygo Zahir Media
Tematy:
złamanie kości
kość ramienna
gwóźdź śródszpikowy
metoda elementów skończonych
humerus
fracture
intramedullary nail
finite element method
Opis:
Złamanie kości ramiennej stanowi blisko 1,5% wszystkich złamań, ale ze względu na wiek zróżnicowana jest przyczyna powstawania urazu. Leczenie operacyjne, stosowane w bardziej rozległych i skomplikowanych urazach, polega na stabilizacji za pomocą implantów płytkowych bądź gwoździ śródszpikowych. W ramach przeprowadzonej analizy numerycznej stabilizacji złamania trzonu kości ramiennej porównano 4 metody zespolenia tytanowego gwoździa śródszpikowego z odłamami kostnymi. Wyniki przeprowadzonych symulacji wykazały, że w zakresie analizowanych danych, każdy z testowanych wariantów umożliwia uzyskanie zrostu kostnego. Maksymalne przemieszczenia międzyodłamowe mieściły się w zakresie 325-540 μm, co stanowi wartość korzystną dla procesów zrostu. Także wartości naprężeń odnotowanych dla poszczególnych modeli nie wskazały na przekroczenie doraźnych wartości na wytrzymałość. Uzyskane wyniki sugerują, że dla danego przypadku każdy z wariantów stabilizacji pozwoli na uzyskanie pozytywnych efektów leczenia.
Fractures of the humerus constitute nearly 1.5% of all fractures, but due to age, the cause of the injury varies. The surgical treatment, used in more extensive and complicated injuries, consists in stabilization with the help of plate implants or intramedullary nails. As part of the numerical analysis of the stabilization of the humerus fracture, 4 methods of the intramedullary nail fixation were compared. The results of the conducted simulations showed that in the range of the analyzed data, each of the tested variants allows for bone union. Maximal interfragmentary movement was in the range of 325-540 μm, which is a favorable value for bone union processes. Also the stresses recorded for individual models did not exceeded the strength of used materials. The obtained results suggest that each of the stabilization variants will allow to obtain positive treatment effects.
Źródło:
Inżynier i Fizyk Medyczny; 2019, 8, 2; 141-144
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The application of intramedullary nails and transmedullary support screws in surgical treatment of distal tibia fracture
Zastosowanie gwoździ śródszpikowych i śrub kierunkowych w leczeniu operacyjnym złamań końca dalszego kości podudzia
Autorzy:
Bęcki, Marcin
Falis, Mirosław
Synder, Marek
Lipiński, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/2186039.pdf
Data publikacji:
2023-03-31
Wydawca:
Wydawnictwo Exemplum
Tematy:
distal tibia fractures
Goldzak classification
intramedullary nail
TMS screw
złamanie dalszego końca kości podudzia
klasyfikacja Goldzaka
gwóźdź śródszpikowy
śruby TMS
Opis:
Introduction. Fractures of the distal tibia are a difficult treatment problem due to the specific anatomy of this area and the soft tissue injuries resulting from trauma. A distal fracture is short, has a wide marrow cavity, and the asymmetric muscle forces acting on it can cause secondary displacements despite the originally correct positioning. Against the background of the problems presented above, the fixation with an intramedullary nail (IMN) with the use of TMS (trans medullary support) screws directional screws seems to be the best alternative for treatment. Aim. The aim of this study was to evaluate the bone fracture repositioning after surgical treatment of tibia fracture, the time of bone healing and the function of the upper ankle joint. Materials and methods. Forty patients treated surgically due to a fracture of the distal tibia with the use of an intramedullary nail and TMS screws were included in this study. The mean follow-up time was 25.3 months. The function of the ankle joint of the injured limb was evaluated using the AOFAS, VAS and SF-36 questionnaires. Radiological documentation was assessed in terms of correct bone fragment repositioning, placement of directional screws and correct union of the fibula. Post-operative X-rays as well as X-rays taken at the end of treatment in AP and lateral projection were also assessed, evaluating LDTA (lateral distal tibial angle) and ADTA (anterior distal tibial angle). Results. The function of the ankle joint after surgical treatment of a distal tibia fracture using the IMN + TMS method is as follows: AOFAS score 91.5, VAS 2.2 / 10 points. The range of motion of the ankle joint: the angles of ankle movement were significantly greater in the case of the uninjured limb compared to the injured one. Bone union was obtained in all patients. In 80% of patients, it was achieved in less than 6 months. Assessment of repositioning after surgery – mean LDTA angle after surgery was 89 and mean ADTA angle after surgery was 86 (standard LDTA 90, ADTA 85). Conclusions. The function of the ankle joint after treatment of a distal tibial fracture with an intramedullary nail and TMS screws according to the AOFAS and VAS scale was very good and allowed for the anatomical bone fragment fixation. The bone healing after fixation of the distal tibial fracture with an intramedullary nail and TMS screws was shorter than 6 month in most cases.
Wstęp. Złamania dalszego końca kości podudzia stanowią trudny problem leczniczy ze względu na specyfikę anatomii tej okolicy. Z punktu widzenia biomechaniki odłam dystalny jest krótki, ma szeroką jamę szpikową, a działające na niego asymetryczne siły mięśniowe mogą spowodować wtórne przemieszczenia, pomimo pierwotnie prawidłowego nastawienia. Z tego powodu zespolenie gwoździem śródszpikowym z użyciem śrub kierunkowych TMS (trans medullary support screws) wydaje się być najlepszą alternatywą. Cel. Celem pracy jest ocena uzyskanej repozycji odłamów kostnych po leczeniu operacyjnym złamań końca dalszego kości podudzia przy użyciu gwoździa śródszpikowego oraz śrub TMS, a także ocena czasu uzyskania zrostu kostnego oraz funkcji stawu skokowego górnego po leczeniu operacyjnym. Materiał i metody. Ocenie poddano 40 chorych leczonych operacyjnie z powodu złamania końca dalszego kości podudzia przy użyciu gwoździa śródszpikowego oraz śrub TMS. Średni czas obserwacji wyniósł 25,3 miesiąca. Funkcję stawu skokowego uszkodzonej kończyny oceniano za pomocą kwestionariuszy AOFAS, VAS oraz SF-36. Oceniano także dokumentację radiologiczną pod kątem prawidłowości repozycji odłamów, umiejscowienia śrub kierunkowych oraz prawidłowości zespolenia kości strzałkowej. Ocenie poddano radiogramy pooperacyjne oraz kończące leczenie w projekcjach AP i bocznej, oceniając kąty LDTA (lateral distal tibial angle) i ADTA (anterior distal tibial angle). Wyniki. Funkcja stawu skokowego po leczeniu operacyjnym złamania końca dalszego kości piszczelowej metodą IMN + TMS przedstawia się następująco: wynik kwestionariusza AOFAS wynosił 91,5/100 punktów, VAS 2,2/10 punktów. Zakres ruchomości stawu skokowego były istotnie większy w przypadku kończyny nieuszkodzonej. Zrost kostny uzyskano u wszystkich chorych. U 80% pacjentów wystąpił on w okresie krótszym niż 6 miesięcy. Ocena repozycji po leczeniu operacyjnym – średni kąt LDTA po operacji wynosił 89°, a średni kąt ADTA 86° (normy LDTA 90°, ADTA 85°). Wnioski. Funkcja stawu skokowego po leczeniu operacyjnym złamania końca dalszego kości piszczelowej gwoździem śródszpikowym oraz śrubami TMS w skali AOFAS odpowiada ocenie bardzo dobrej, a w skali VAS odpowiada odczuwaniu łagodnego bólu. Zespolenie tą metodą pozwala na uzyskanie anatomicznej repozycji odłamów kostnych, a zrost kostny odłamów w większości przypadków uzyskano w czasie krótszym niż 6 miesięcy.
Źródło:
Chirurgia Narządów Ruchu i Ortopedia Polska; 2023, 88, 1; 5-12
0009-479X
2956-4719
Pojawia się w:
Chirurgia Narządów Ruchu i Ortopedia Polska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A numerical comparative analysis of ChM and Fixion nails for diaphyseal femur fractures
Autorzy:
Ivanov, D.
Barabash, Y.
Barabash, A.
Powiązania:
https://bibliotekanauki.pl/articles/306299.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
FEM
gwóźdź śródszpikowy
kość udowa
sztywność
model 3D
finite element analysis
intramedullary nail
femur
effective stress
stiffness
3D model
Opis:
Purpose: Today intramedullary locked nails are widespread in treatment of diaphyseal long bone fractures of the lower limb. However, such nails have a number of drawbacks: complexity and duration of the installation, high axial stiffness, as well as the failure of locking screws and nail body. Expandable nails such as Fixion have several advantages over lockable ones. They can be quickly installed without the need of reaming and provide sufficient stabilization of the fracture. However, many studies show their low stability under torsional loads. Methods: In this paper, geometric characteristics of Fixion nail were investigated. Bone-nail systems (with Fixion and locked nail) under the influence of three types of loads were numerically studied. Two types of diaphyseal femoral fractures (type A and B in accordance with AO/ASIF classification) were examined. Results: It was revealed that Fixion nail provides axial stiffness of 489 N/mm for the fractures studied. Expandable nail showed higher compression at fragments junction than locked nail. Torsional stability of Fixion nail was also high. Corrosion was found on inner surface of Fixion nail. Conclusions: Fixion nail showed high stability under influence of the three loads studied. Corrosion on the internal wall of the nail may indicate its relatively low resistance to saline.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 3; 73-81
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies