Tytuł:
The design of an insulin pump concept of closing the loop
Autorzy:
Hawłas, H.
Lewenstein, K.
Powiązania:
https://bibliotekanauki.pl/articles/385242.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
insulin pump
diabetes
artificial pancreas
Opis:
This paper explains what insulin pump is and outlines basic requirements for such device. The material presented in this paper is an attempt to collect actual knowledge about closed loop insulin delivery systems. From scientific point of view we are going to propose the closed loop insulin-dispensing device with control built on the base of predictive neural network system. The blocks of such systems are listed, and main problems to overcome are defined.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 195-198
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Robustness of closed-loop glucose control systems
Autorzy:
Wyciślok, Artur
Śmieja, Jarosław
Powiązania:
https://bibliotekanauki.pl/articles/29432415.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
artificial pancreas
closed-loop control
insulin pump
type 1 diabetes
Opis:
The main purpose of this work is to provide an extensive, simulation-based comparison of robustness of PID and MPC algorithms in control of blood glucose levels in patients with type 1 diabetes and thus answer the question of their safety. Cohort testing, with 1000 simulated, randomized patients allowed to analyze specific control quality indicators, such as number of hypoglycemic events, and length of hypo- and hyperglycemia periods. Results show that both algorithms provide a reasonable safety level, taking into account natural changes of patients’ physiological parameters. At the same time, we point out drawbacks of each solution, as well as general problems arising in close-loop control of blood glucose level.
Źródło:
Archives of Control Sciences; 2023, 33, 3; 681--705
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Physical activity in type 1 diabetic young and early adults treated with insulin pump therapy. A preliminary report
Autorzy:
Roszkowski, A.
Kulesza, K.
Cybulski, M.
Witkowska, A.M.
Powiązania:
https://bibliotekanauki.pl/articles/1918883.pdf
Data publikacji:
2019-08-26
Wydawca:
Uniwersytet Medyczny w Białymstoku
Tematy:
Type 1 diabetes
insulin pump
physical activity
young adults
early adults
IPAQ
Opis:
Purpose: To determine the level of physical activity in young and early adults with type 1 diabetes in comparison with their healthy counterparts and to determine whether the use of insulin pump facilitates physical activity. Materials and methods: This study included 40 type 1 diabetes (T1D) subjects of both sexes treated with a personal insulin pump therapy, and 30 healthy controls. The diagnostic survey included questions about nutrition, knowledge about the disease and whether the patient can control diabetes through physical activity, diet and self-monitoring. The International Physical Activity Questionnaire – long form (IPAQ-L), was used to assess the level of physical activity of both diabetic and control individuals. Results: 87.5% T1D subjects believe that using an insulin pump facilitates their physical activity. The level of physical activity associated with cycling (p=0.038) and vigorous physical activity (p=0.008) was higher in T1D than in the control group. Statistically significant differences (p=0.043) were found for total physical activity. The total mean activity was higher in participants with T1D (8147.70 MET-min/week) compared to the control group (5857.55 MET-min/week). Conclusions: Young and early adults with type 1 diabetes may be more physically active than their healthy counterparts, mainly in their leisure time. The use of a personal insulin pump facilitates physical activity, but most diabetics experience episodes of hypoglycemia after physical activity.
Źródło:
Progress in Health Sciences; 2019, 1; 13-21
2083-1617
Pojawia się w:
Progress in Health Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the safety of users of active implantable medical devices (AIMD) in the working environment in terms of exposure to electromagnetic fields – Practical approach to the requirements of European Directive 2013/35/EU
Autorzy:
Zradziński, Patryk
Karpowicz, Jolanta
Gryz, Krzysztof
Leszko, Wiesław
Powiązania:
https://bibliotekanauki.pl/articles/2162037.pdf
Data publikacji:
2018-12-20
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
workers’ safety
cardiac pacemakers
implanted defibrillators
exposure effects
electromagnetic interference
wearable insulin pump
Opis:
Objectives Electromagnetic fields (EMF) may cause malfunctions in electronic devices, in particular in active implantable medical devices (AIMD), along with discomfort or health hazards to users. The use of AIMD by workers is increasing (especially cardiac pacemakers, implantable cardioverter defibrillators and wearable insulin infusion pumps). Electromagnetic fields may be much stronger in the working environment than applied in basic immunity tests of AIMD (based on EN 60601- 1-2:2015 and EN 50527-1:2016). European Directive 2013/35/EU regarding the safety of workers exposed to EMF considered the AIMD users to be “workers at particular risk” who need an individual evaluation of EMF hazards. The study aimed at evaluating the safety of users of AIMD in medical and industrial working environments exposed to EMF Material and Methods Near the common sources of strong EMF applied in medical and industrial use, the “standard safety distances” (SSD) for AIMD users were evaluated (i.e., distances from the EMF source, where exposure drops below limits from Recommendation 1999/519/EC and AIMD safety may be expected). The analysis is based on the results of measurements of magnetic and electric field strengths near 127 typical devices, in their normal use. Results The longest electric field related SSD was identified near dielectric sealers (up to 180 cm), and the longest magnetic field related SSD – near induction heaters (up to 450 cm). Conclusions Electromagnetic fields related AIMD malfunctions need to be considered up to several meters from EMF sources. The “individual safety distance,” that is sufficient to ensure the safety of a particular AIMD user may be significantly different (usually shorter) from the presented SSD, but needs to be considered in the context of detailed safety data from the AIMD manufacturer (if available). The labelling indicating the location of the area of a strong EMF increases safety of AIMD users in the work environment. Int J Occup Med Environ Health 2018;31(6):795–808
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2018, 31, 6; 795-808
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu wymuszenia posiłek - dawka insuliny na przebieg krzywych cukrowych komputerowych modeli pacjentów
Analysis of impact of meal insulin dose excitation on glucose traces in silico subjects
Autorzy:
Hawłas, H. J.
Lewenstein, K.
Powiązania:
https://bibliotekanauki.pl/articles/155850.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
hiperglikemia
krzywe cukrowe
model komputerowy pacjenta
hipoglikemia
sterowanie pompy insulinowej
glucose trace
hyperglycaemia
hypoglycaemia
in-silico model
insulin pump control
Opis:
Końcowym celem badań, których fragment zaprezentowano w niniejszej pracy jest opracowanie inteligentnego algorytmu pozwalającego na automatyczne sterowanie osobistą pompą insulinową na podstawie sygnałów otrzymywanych z urządzenia do ciągłego pomiaru stężenia glukozy. Wstępne badania przeprowadzone zostały w formule in silico czyli przy użyciu modelu komputerowego odzwierciedlającego funkcjonowanie żywego organizmu. W rozpatrywanym przypadku zastosowano model opracowany przez zespół dr. Boris Kovatchev'a z University of Virginia, USA. Analizowano przebiegi odpowiedzi modelu - krzywe cukrowe BG, na zmieniane wymuszenia w postaci zróżnicowanych posiłków i dawek insuliny. W efekcie stwierdzono silne zindywidualizowanie odpowiedzi a ponadto konkretny jakościowy wpływ czasu posiłku i wielkości dawki insuliny (w tym także podziału tej dawki na części), na możliwość utrzymania poziomu glukozy w przedziale pożądanym - pomiędzy 70mg/dl a 180 mg/dl, umożliwiające uniknięcie występowania groźnych dla pacjenta stanów hipoglikemi i hiperglikemi. Zakładamy, że otrzymane rezultaty pomogą przy późniejszym wdrażaniu gotowego systemu sterowania pompy insulinowej kontrolującego poziom stężenia glukozy we krwi chorego.
The material presented in this paper describes one of the steps in design of our control algorithm for Closed Loop Insulin Delivery. Such a system would consist of Insulin Pump with Continuous Glucose Monitoring Device and Control Algorithm. The presented work gives information about the qualitative influence of treatment parameters on blood glucose (BG) traces. The study utilises computer model tests (in-silico) for obtaining the BG level information. The great advantage of such computer tests is possi-bility to conduct several similar examinations leading to the family of traces that are different by a single parameter, while the other parameters are constant. The used computer simulator was delivered by the University of Virginia [3, 4]. Fig. 1 shows interspecies differences for subjects, which proves the need for control algorithm individualisation. Fig. 2 presents the impact of the bolus delivery time regarding the meal delivery time for an adult subject. Delivering the insulin in advance to meal reduces the BG. In Fig. 3 the influence of the meal duration time on the BG response is shown. Extending the meal duration slightly lowers the BG, but does not influence noticeably the fall ratio. Fig. 4 depicts the changes due to the bolus value, a higher bolus causes the lower BG and faster fall rate of change. Fig. 5 illustrates the test result of bolus distribution into 3 doses delivered within some period. Scheme 10/20/70 every 60min means that a single bolus is split into 10%, then 20% and 70% doses within the period of 60 minutes. There can be noted the response similarity between 10/20/70 every 15min and 70/20/10 every 60min, in spite of the fact that the drug delivery schemes are significantly different . This proves the possibility of long term BG regulation. None of the above tests show noticeable changes of the BG rise ratio, thus it cannot be easily controlled by insulin or meal delivery. The main purpose of the control algorithm isto avoid harmful extreme values of the BG. The presented study allows the better algorithm planning because the influence of a different type of meal and insulin scenario on the BG trace is known.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 12, 12; 1124-1128
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The course of glucose intolerance in children with cystic fibrosis: a retrospective study − preliminary report
Przebieg nietolerancji glukozy u dzieci z mukowiscydozą: badanie retrospektywne − doniesienie wstępne
Autorzy:
Piechowiak, Katarzyna
Trippenbach-Dulska, Hanna
Walicka-Serzysko, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/772645.pdf
Data publikacji:
2015
Wydawca:
Wydawnictwo ALUNA
Tematy:
cystic fibrosis related diabetes
glucose monitoring
insulin
pump
Opis:
Diabetes is a common and severe complication of cystic fibrosis. If unrecognized, the condition not only causes deterioration of pulmonary function and failure to gain weight, but also a six-fold increase in mortality. Aim: 1. To evaluate the course of abnormal glucose tolerance and cystic fibrosis-related diabetes (CFRD), as well as the effects of treating these conditions in children with cystic fibrosis. 2. To analyze the association between the classes of mutations in both alleles of the CFTR gene and glucose intolerance. Materials and methods: analysis was undertaken of the clinical records of 12 children (from the years 2002 to 2014), who were under the care of the Diabetes Outpatient Clinic at the Medical University of Warsaw and the Cystic Fibrosis Centre of the Institute of Mother and Child in Warsaw. The patients were divided into groups based on glucose tolerance categories in the Oral Glucose Tolerance Test (impaired glucose tolerance - IGT, cystic fibrosis related diabetes without fasting hyperglycemia − CFRD FH(-) or with fasting hyperglycemia – CFRD FH (+)). The mean age of the children who were referred to the Diabetes Outpatient Clinic was 12.09±3.57 years and the mean HbA1c at the baseline versus the end of the follow up was 6.16±1,77% versus 6.03±1.05%, respectively. We used the continuous glucose monitoring system (CGMS) for the diagnostics of 4 patients. The mutations in the cystic fibrosis transmembrane conductance regulator (CFTR) gene were investigated in all the patients. All the children had mutations in at least one allele of the CFTR gene belonging to class I or II. Six (6/12) patients were homozygous, and 3 (3/12) patients heterozygous for the Phe508del (former F508del) mutation. Three children had other mutations (1717-1G>A/2183AA-G, R553X/3380delGAAG, G542X/2143delT). Results: In our study group we recognized impaired glucose tolerance (IGT) in 7 (7/12) patients and cystic fibrosis-related diabetes (CFRD) in 5 (5/12) patients; there were 4 patients with CFRD FH(+) and 1 patient with CFRD FH(-). During follow up we observed IGT deterioration of glucose tolerance towards CFRD FH(-) in 4(4/7) patients. Eight (8/12) patients were on functional insulin therapy, five of them (5/8) used insulin pumps. The remaining patients (4 individuals - 4/12), who were in good condition and on a high-glycemic index product restricted diet, did not require insulin. In the group treated with insulin we observed improvement in BMI z-scores (from-1.14 to -0.70). Conclusions: Glucose tolerance in children with cystic fibrosis deteriorates with age. Patients in a good condition and with good compliance to a low-glycemic index product diet, start insulin therapy later. Patients with a severe course of cystic fibrosis and diabetes require immediate insulin implementation. Insulin treatment improves their nutritional status. A continuous glucose monitoring system is a useful diagnostic tool which can be taken into account in therapeutic decisions. Prospective studies on the pediatric population with cystic fibrosis are needed in Poland for a better analysis of the associations between abnormal glucose tolerance, the class of mutation in the CFTR gene and the impact of glucose intolerance treatment on the clinical status of the patients.
Cukrzyca jest częstym i ciężkim powikłaniem mukowiscydozy. Nierozpoznana nie tylko prowadzi do pogorszenia czynności płuc i słabszych przyrostów masy ciała, lecz również zwiększa 6-krotnie śmiertelność. Cel: 1. Ocena przebiegu zaburzeń tolerancji glukozy i cukrzycy u dzieci z mukowiscydozą oraz efekty ich leczenia. 2. Ocena związku pomiędzy klasą mutacji w genie CFTR i nietolerancją glukozy. Materiały i metody: Przeanalizowano retrospektywnie dokumentację medyczną 12 dzieci (z lat 2002- -2014), będących pod opieką Poradni Diabetologicznej Kliniki Pediatrii Warszawskiego Uniwersytetu Medycznego i Zakładu Mukowiscydozy Instytutu Matki i Dziecka w Warszawie. Pacjentów podzielono według kategorii zaburzeń tolerancji glukozy w teście doustnego obciążenia glukozą (nieprawidłowa tolerancja glukozy, cukrzyca związana z mukowiscydozą bez hiperglikemii na czczo, cukrzyca związana z mukowiscydozą z hiperglikemią na czczo). Średni wiek dziecka w momencie skierowania do Poradni Diabetologicznej wynosił 12,09±3,57 lat, średnia wartość HbA1c na początku i na końcu obserwacji wynosiła 6,16±1,77% versus 6,03±1,05. U 4 pacjentów w trakcie diagnostyki zaburzeń przemiany węglowodanowej zastosowano ciągły monitoring glikemii. U wszystkich dzieci oznaczono klasy mutacji w genie CFTR. Wszyscy pacjenci mieli przynajmniej w jednym allelu genu CFTR mutacje należące do I lub II klasy. Sześcioro (6/12) pacjentów było homozygotami a troje (3/12) pacjentów heterozygotami mutacji Phe508del (dawniej F508del). Troje dzieci miało inne mutacje (1717-1G>A/2183AA-G, R553X/3380delGAAG, G542X/2143delT). Wyniki: U 7 (7/12) pacjentów z badanej grupy rozpoznano nieprawidłową tolerancję glukozy, u 5 (5/12) pacjentów cukrzycę związaną z mukowiscydozą w tym u 4 pacjentów z hiperglikemią na czczo a u jednego bez hiperglikemii na czczo. W trakcie obserwacji stwierdziliśmy u 4 (4/7) pacjentów z nieprawidłową tolerancją glukozy pogorszenie jej przebiegu w kierunku cukrzycy bez hiperglikemii na czczo. U 8 (8/12) pacjentów zastosowano insulinoterapię, u większości (5/8) pacjentów przy pomocy pompy insulinowej. Pozostali pacjenci (4 osoby -4/12), którzy byli w dobrym stanie klinicznym i przestrzegali diety z ograniczeniem produktów o wysokim indeksie glikemicznym, nie wymagali insulinoterapii. U pacjentów leczonych insuliną obserwowano wzrost BMI z-scores (z -1,14 do -0,70). Wnioski: Tolerancja glukozy u dzieci z mukowiscydozą pogarsza się z wiekiem. Pacjenci w dobrym stanie klinicznym i przestrzegający diety z ograniczeniem produktów o wysokim indeksie glikemicznym wymagają insulinoterapii w późniejszym okresie. Pacjenci z ciężkim przebiegiem mukowiscydozy i cukrzycą wymagają natychmiastowej insulinoterapii. Leczenie insuliną poprawia stan odżywienia. Ciągły monitoring glikemii jest przydatnym narzędziem diagnostycznym, który należy brać pod uwagę przy podejmowaniu decyzji terapeutycznych. Prospektywne badania większej populacji pediatrycznej chorych na mukowiscydozę w Polsce są potrzebne, celem lepszego poznania związku pomiędzy zaburzeniami tolerancji glukozy, klasą mutacji w genie CFTR, wpływu metody leczenia zaburzeń tolerancji glukozy na stan kliniczny pacjentów.
Źródło:
Developmental Period Medicine; 2015, 1; 80-91
1428-345X
Pojawia się w:
Developmental Period Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies