Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "insulation system" wg kryterium: Temat


Tytuł:
Comparison of concentrated winding topologies considering transient voltages in the winding system of inverter-driven low-voltage machines
Autorzy:
Pauli, Florian
Driendl, Niklas
Mönninghoff, Sebastian
Hameyer, Kay
Powiązania:
https://bibliotekanauki.pl/articles/2172796.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
d/d
electrical machines
insulation system
inverters
transient voltages
Opis:
To reduce the losses of the power electronic inverter, the voltage slew rate (d u/d t) of the electric motors supplying voltage is increasing. As steep voltage slopes excite high frequencies in the megahertz range, transient phenomena in the winding of the electrical machine occur. To design the insulation system, the maximum electric potential difference between the conducting elements must be predicted. General design rules can lead to a significant overengineering of the interturn insulation, particularly when considering smaller stators with a known wire distribution. Therefore, two different winding topologies are studied comparing the voltage distribution in a round-wire winding and a winding with preformed coils.
Źródło:
Archives of Electrical Engineering; 2022, 71, 4; 865--880
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of conductive particle contaminationon the insulation system of rotating electrical machines with direct oil cooling
Autorzy:
Yang, Liguo
Pauli, Florian
Zhang, Shimin
Hambrecht, Fabian
Hameyer, Kay
Powiązania:
https://bibliotekanauki.pl/articles/2135735.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cooling
insulation system
particle contamination
partial discharge
surface resistance
Opis:
An integration of the electrical machine and the gearbox is attracting particular attention for the design of modern electric and hybrid drive trains, since it saves overall space and subsequently increases the power density. Another benefit of a high level of integration is that it enables a combined application of oils as both cooling fluid for the electrical machine and as lubrication fluid for the transmission system. In this way, the power density of the integrated drive train can be further increased. During the oil cycling, conductive contaminations may be introduced and subsequently have an influence on the function of the insulation system of the electrical machine. In the present work, the influences of the cooling oil and its conductive contaminations, conductive particles as well as their combination with humidity, on the electrical and dielectric properties of the insulation system are studied. The results show that by application of the cooling oil, the partial discharge inception voltage (PDIV) of the winding insulation increases significantly so that an electrical breakdown is prone to happen before a partial discharge (PD) occurs. With increasing particle contamination, the PDIV of the insulation system decreases significantly, while the capacitance increases. Besides, conductive particles and humidity decrease the surface resistance and surface breakdown voltage of the insulation papers significantly. The results indicate that the conductive particle contaminations can play an important role for the electrical degradation of the insulation system.
Źródło:
Archives of Electrical Engineering; 2022, 71, 3; 789--804
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The application of a molecular sieve for drying the insulation system of a power transformer in terms of improving its perational reliability
Autorzy:
Cybulski, Mateusz
Przybyłek, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2172034.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
power transformer
insulation system
drying
molecular sieve
mineral oil
natural ester
synthetic ester
Opis:
The first research objective was the assessment of the selectivity of water and hydrogen adsorption by the 3A molecular sieve (MS) in the terms of the safety of using the DGA (Dissolved Gas Analysis) method as a diagnostic technique. The second objective was to demonstrate the efficiency of drying the insulation system consisting of cellulose insulation impregnated with various insulating liquids in terms of improving safety and extending the service life of power transformers. In order to achieve the assumed objectives, measurement systems were prepared and material tests were carried out, based mainly on chromatographic analyzes and measurements of water content using the Karl Fischer titration method. On the basis of the obtained test results and the conducted physical analyzes, the selectivity of MS sorption was shown and it was explained that the facilitator of the adsorption of water molecules is their polar nature related to their large dipole moment. The high efficiency of drying cellulose insulation impregnated with various insulating liquids using MS was also demonstrated.
Źródło:
Eksploatacja i Niezawodność; 2022, 24, 3; 502--509
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania systemu ETICS z polistyrenem EPS i wełną mineralną
Testing of the ETICS system with EPS polystyrene and mineral wool
Autorzy:
Krause, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2055947.pdf
Data publikacji:
2021
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
system ocieplania
ETICS
metoda lekka mokra
styropian
wełna mineralna
izolacja cieplna
badanie laboratoryjne
metoda badań
ściana ocieplona
rozkład temperatury
badanie wilgotności
thermal insulation system
light-weight method
EPS
expanded polystyrene foam
mineral wool
thermal insulation
laboratory test
test method
thermoinsulated wall
temperature distribution
humidity examination
Opis:
W celu określenia wpływu wzajemnego połączenia zróżnicowanych izolacji cieplnych w systmie ETICS na stan ochrony cieplno-wilgotnościowej zrealizowano badania w skali laboratoryjnej.
In order to determine the influence of the mutual connection of different thermal insulations in the ETICS system on the condition of thermal and humidity protection, laboratory scale tests were carried out.
Źródło:
Przegląd Budowlany; 2021, 92, 11-12; 90--93
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of thermal-mechanical stress on the insulation system of a low voltage electrical machine
Autorzy:
Yang, Liguo
Pauli, Florian
Hameyer, Kay
Powiązania:
https://bibliotekanauki.pl/articles/1841343.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
insulation system
material fatigue
thermal-mechanical stress
system izolacji
zmęczenie materiału
naprężenie cieplno-mechaniczne
Opis:
Varying ohmic loss in the winding of electrical machines, which are operated atvarious operating points, results in temperature changes during operation. Particularly, when the temperature is varying dynamically, the insulation system suffers from repeated thermal-mechanical stress, since the thermal expansion coefficients of the insulating materials and copper conductors are different. For the appropriate design of an insulation system, the effect of thermal-mechanical stress must be known. In the present work, motorettes are subjected to repeated thermal cycles. The expected lifetime is estimated and compared to the life time which is achieved by applying a lifetime-model which only considers thermal aging while ignoring thermal-mechanical stress effects. In addition, the hotspot temperature is simulated, the lifetime at the hotspot is estimated as the worst case. As expected, the results indicate that the thermal-mechanical stress plays a significant role during dynamic thermal aging of the winding insulation system. To better understand the thermal-mechanical stress effect, the resulting thermal-mechanical stress in a single wire is analyzed by the finite element method. A preliminary analysis of the aging mechanism of materials due to cyclic thermal-mechanical stress is performed with the theory of material fatigue.
Źródło:
Archives of Electrical Engineering; 2021, 70, 1; 233-244
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Procedura doboru sposobu termorenowacji budynków zabytkowych w aspektach konserwatorskich, technicznych, środowiskowych i ekonomicznych
Procedure for selecting a method of thermal renovation of historic buildings within the scope of conservation, technical, environmental and economic issues
Autorzy:
Rogalska, Magdalena
Hejducki, Zdzisław
Powiązania:
https://bibliotekanauki.pl/articles/1857852.pdf
Data publikacji:
2021
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
budynek zabytkowy
termorenowacja
ocieplanie
metoda ocieplania
wymagania konserwatorskie
ocena techniczna
historic building
thermal renovation
external thermal insulation
thermal insulation system
conservation requirements
technical assessment
Opis:
W niniejszej pracy zaproponowano analizę doboru systemów termorenowacji budynków zabytkowych przy zastosowaniu algorytmu uwzględniającego zalecenia konserwatorskie, ochronę środowiska, prawidłowość techniczną i efektywność ekonomiczną. Rozwiązanie ma na celu umożliwienie doboru systemu termomodernizacji budynków zabytkowych, z uwzględnieniem następujących aspektów: ingerencji w substancję historyczną budynków, energię wcieloną w cyklu życia obiektu zabytkowego, zanieczyszczenia środowiska, kosztów izolacji w cyklu życia budynku, czasu trwania obiektu, wykorzystania lokalnych materiałów i technologii, efektywności ekonomicznej i energetycznej rozwiązań.
This paper proposes an analysis of the selection of thermal rehabilitation systems for historic buildings using an algorithm that takes into account conservation recommendations, environmental protection, technical correctness and economic efficiency. The solution aims to enable the selection of the system for thermo renovation of historic buildings, taking into account the following aspects: interference in the historical substance of buildings, embodied energy in the life cycle of the historic building, environmental pollution, insulation costs in the life cycle of the building, duration of the building, use of local materials and technologies, economic and energy efficiency of the solutions.
Źródło:
Przegląd Budowlany; 2021, 92, 7-8; 113-118
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza systemów termoizolacyjnych nieingerujących w fasadę budynku
Analysis of thermal insulation systems which do not interfere with the building facade
Autorzy:
Ksit, Barbara
Jankowiak, Magdalena
Powiązania:
https://bibliotekanauki.pl/articles/973553.pdf
Data publikacji:
2020
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
ocieplanie od wewnątrz
system ocieplania
izolacja cieplna
budynek zabytkowy
poliuretan
współczynnik przewodzenia ciepła
dyfuzja pary wodnej
analiza termiczna
metoda numeryczna
Wufi
internal thermal insulation
thermal insulation system
thermoinsulation
historical building
polyurethane
heat conduction coefficient
water vapour diffusion
thermal analysis
numerical method
Opis:
W artykule przedstawiono doświadczalne systemy występujące na rynku budowlanym, przeznaczone do ocieplania budynków od wewnątrz. Zaprezentowano wytyczne prawne dotyczące termoizolacji, powołując się na Dyrektywę Parlamentu Europejskiego oraz normy polskie. Zestawiono podstawową wiedzę na temat syntetycznych materiałów komórkowych i przedstawiono odmiany stosowane przy ocieplaniu od wewnątrz. Sklasyfikowano systemy ze względu na dyfuzję otwartą oraz zamkniętą. Wybrane parametry techniczne systemów przedstawiono w postaci wykresów. Przedstawiono algorytm postępowania w przypadku modelowania przegrody uwzględniające parametry klimatyczne, zacinające deszcze, występujące w danej okolicy, zawilgocenie budynku oraz magazynowanie ciepła i wilgoci prze przegrodę.
The article presents experimental systems available on the construction market, intended for internal insulation of buildings. It describes legal guidelines for thermal insulation with reference to the Directive of the European Parliament as well as to Polish standards. It compiles basic knowledge on synthetic cellular materials and presents the variants used for internal insulation. It also contains a classification of the systems according to open and closed diffusion. Selected technical parameters of the systems have been presented in the form of charts. An algorithm of conduct in the case of partition modeling has been presented, taking into account climatic parameters, slanting rains occurring in a given area, moisture content of the building and storage of heat and moisture by the partition.
Źródło:
Przegląd Budowlany; 2020, 91, 11; 39-42
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis on Acoustic Disturbance Signals Expected During Partial Discharge Measurements in Power Transformers
Autorzy:
Kunicki, Michał
Powiązania:
https://bibliotekanauki.pl/articles/1953519.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
acoustic emission
partial discharge
insulation system
measurements
power transformers
Opis:
This paper presents comparative analysis of various acoustic signals expected during partial discharge (PD) measurements in operating power transformer. Main purpose of the paper is to yield relevant and reliable method to distinguish between various acoustic emission (AE) signals emitted by PD and other sources, with particular consideration of real-life results rather than laboratory simulations. Therefore, selected examples of real-life AE signals registered in seven different power transformers, under normal operation conditions, within few years are showed and analyzed. Five scenarios are investigated, which represent five types of AE sources: PD generated by artificial sources, and next four real-life sources (including PD in working transformer, oil flow, oil pumps and core). Several different signal processing methods are applied and compared in order to identify the PD signals. As a result, an energy patterns analysis based on the wavelet decomposition is found as the most reliable tool for identification of PD signals. The presented results may significantly support the process of interpretation of the PD measurement results, and may be used by field engineers as well as other researchers involved in PD analysis using AE method. Finally, observed properties also provide a solid basis for establishing or improving complete classification method based on the artificial intelligence algorithms.
Źródło:
Archives of Acoustics; 2020, 45, 4; 733-746
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Low voltage winding insulation systems under the influence of high du/dt slew rate inverter voltage
Autorzy:
Pauli, Florian
Ruf, Andreas
Hameyer, Kay
Powiązania:
https://bibliotekanauki.pl/articles/140993.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
life time
partial discharge
SiC semiconductors
winding insulation system
Opis:
Variable speed and low voltage electrical drives are commonly operated by frequency converters. According to recent developments, there is a trend in the area of semi-conductors, that switching frequency and voltage slew rate will increase significantly. The aim of these semiconductors is to reduce the switching losses and to increase the switching frequency, which enables to reduce the size of passive components in the powerelectric circuit. This results in less material effort and lower cost, for the power electronic component. However, electric motors operated by high slew rate inverters show problems in the winding insulation, which have to be analyzed. Such problems are well known for high voltage machines. Due to the increasing slew rate, this problematic occurs in low voltage machines nowadays as well. Here, the influence of fast switching semiconductors on the winding insulation system is studied, using accelerated ageing tests with fast switching high-voltage generators.
Źródło:
Archives of Electrical Engineering; 2020, 69, 1; 187-202
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Okresowe oceny stanu technicznego elewacji budynków. Cz. 1. Wymagania ogólne
Periodic assessments of the technical condition of building facades. Part 1. General requirements
Autorzy:
Runkiewicz, Leonard
Sieczkowski, Jan
Kopyłow, Ołeksij
Powiązania:
https://bibliotekanauki.pl/articles/128956.pdf
Data publikacji:
2020
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
elewacja
elewacja wentylowana
ETICS
metoda lekka mokra
system ociepleń
ocena okresowa
stan techniczny
elevation
ventilated facade
light-wet method
thermal insulation system
periodic assessment
technical condition
Opis:
Elewacje budynków mają znaczący wpływ na ich bezpieczeństwo, trwałość i szeroko rozumiany komfort użytkowania, a także na wartość nieruchomości. Niewykryte w odpowiednim czasie uszkodzenia obniżają wartości estetyczne i użytkowe budynków, a w stadium zaawansowanym mogą być przyczyną awarii, a nawet katastrof budowlanych. Przedmiotem artykułu są zagadnienia związane z okresowymi ocenami stanu technicznego elewacji. Przedstawiono wspólne dla wszystkich typów elewacji procedury badań i ocen, zwrócono uwagę na konieczność stosowania sprzętu specjalistycznego do oceny technicznej elewacji.
Building facades have a significant impact on their safety, durability and widely understood comfort of use, as well as on the value of the property. Damages not detected in a timely manner reduce the aesthetic and functional values of buildings, and in the advanced stage they can cause failures or even construction disasters. The subject of the paper are issues related to periodic assessments of the technical condition of the facade. Inspection procedures common to all types of facades were presented, and the need to use specialized equipment for technical assessment of facades was pointed out.
Źródło:
Builder; 2020, 24, 7; 15-17
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Okresowe oceny stanu technicznego elewacji budynków Cz. 3. Systemy ETICS
Periodic assessments of the technical condition of building facades. Part 3. External Thermal Insulation Composite Systems (ETICS)
Autorzy:
Runkiewicz, Leonard
Sieczkowski, Jan
Kopyłow, Ołeksij
Powiązania:
https://bibliotekanauki.pl/articles/129455.pdf
Data publikacji:
2020
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
metoda lekka mokra
system ocieplania
ocieplanie
ściana zewnętrzna
ocena okresowa
stan techniczny
elewacja
uszkodzenie
degradacja
ETICS
external thermal insulation composite system
periodic assessment
technical condition
elevation
damage
degradation
Opis:
Złożone systemy ocieplania ścian ETICS należą do najbardziej rozpowszechnionych systemów elewacyjnych we współczesnym polskim budownictwie. Są one masowo stosowane ze względu na bardzo dobre właściwości termoizolacyjne, walory estetyczne, a także relatywnie niską cenę. Poprawnie zaprojektowany i wykonany system elewacyjny poddawany regularnym konserwacjom pozwala na długoletnią bezawaryjną eksploatację elewacji. Dlatego bardzo istotne jest objęcie takich systemów elewacyjnych monitoringiem pozwalającym na wczesne wykrycie uszkodzeń i zachodzących zmian. Przedmiotem artykułu są zasady przeprowadzania okresowych badań i ocen stanu technicznego elewacji wykonanych w systemach ETICS. Na podstawie wieloletnich doświadczeń eksperckich, a także analiz protokołów kontroli budynków przedstawiono podstawowe narzędzia oraz tryb postępowania podczas kontroli okresowych, niezbędne do wiarygodnych ocen stanu technicznego elewacji. Przedstawiono podstawowe typy uszkodzeń omawianych systemów elewacyjnych oraz wskazano przyczyny ich występowania.
External Thermal Insulation Composite Systems (ETICS) belong to the most common facade systems in contemporary Polish construction. They are used on a large scale due to very good thermal insulation properties, aesthetic values, as well as a relatively low price. A properly designed and constructed facade system subject to regular maintenance allows for long-term trouble-free operation of the facade. That is why it is very important to cover the façade system with monitoring, allowing for early detection of damage and occurring changes. The subject of the article are the rules for conducting periodic tests and assessments of the technical condition of facades made in ETICS systems. On the basis of many years of expert experience, as well as analyzes of building control protocols, basic tools and procedures for periodic inspections necessary for reliable assessment of the technical condition of the facade were presented. The basic types of damages of the discussed façade systems are presented and the reasons for their occurrence are indicated.
Źródło:
Builder; 2020, 24, 9; 19-23
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Płytki ceramiczne w systemach ociepleniowych
Autorzy:
Chruściel, Barbara
Niziurska, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/36081585.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
zewnętrzne systemy ocieplenia
płytki ceramiczne
External Thermal Insulation Composite System
ceramic tiles
Opis:
Płytki ceramiczne są materiałem powszechnie używanym w budownictwie. Wysokie odporności na ścieranie i statyczne obciążenia mechaniczne pozwalają na wykorzystanie ich jako materiał wykończeniowy podłóg. Dzięki tym cechom oraz odporności na działanie wody wykorzystywane są jako wykończenie nie tylko podłóg ale i ścian w wilgotnych pomieszczeniach tj. kuchnie, łazienki, baseny itp. Jednak własności mechaniczne i trwałość nie są wyłącznym powodem tak powszechnego zastosowania płytek w naszym otoczeniu. Bardzo ważną cechą jest możliwość wytwarzania ich w szerokiej gamie kolorystycznej oraz możliwość zdobienia różnorodnymi wzorami, co umożliwia uzyskanie wysokich wartości estetycznych każdego wnętrza, a wg najnowszych trendów również elewacji budynków. To właśnie wysoka trwałość i odporność na uderzenie spowodowały, że płytki ceramiczne znalazły powszechne zastosowanie jako elementy wykończenia ścian zewnętrznych również w systemach ocieplenia ścian zewnętrznych ETICS.
Ceramic tiles are a material commonly used in construction. High abrasion resistance and static mechanical loads allow them to be used as a floor finishing elements. Thanks to these features and resistance to water, they are used as a finish not only for floors but also for walls in wet rooms, such as kitchens, bathrooms, swimming pools, etc. However, mechanical properties and durability are not the only reason why tiles are so widely used in our surroundings. A very important feature is the possibility of producing them in a wide range of colors and the possibility of decorating with various patterns, which allows obtaining high aesthetic values of any interior, and according to the latest trends, also the facades of buildings. It is the high durability and impact resistance that made ceramic tiles widely used as external wall finishing elements, also in External Thermal Insulation Composite System (ETICS).
Źródło:
Szkło i Ceramika; 2020, 71, 4; 33-34
0039-8144
Pojawia się w:
Szkło i Ceramika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy technologiczno-materiałowe w realizacjach systemów ociepleń z okładziną nieciągłą
Technological and material problems in the implementation of external thermal insulation composite systems with discontinuous cladding
Autorzy:
Francke, Barbara
Zamorowska, Renata
Powiązania:
https://bibliotekanauki.pl/articles/128768.pdf
Data publikacji:
2020
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
ocieplanie
metoda lekka mokra
ściana zewnętrzna
okładzina nie ciągła
płytka ceramiczna
wełna mineralna
styropian
ciężar własny
przemieszczenie
external thermal insulation composite system
external wall
discontinuous cladding
ceramic tile
mineral wool
expanded polystyrene
dead load
displacement
Opis:
W artykule przeanalizowano mechanizm utraty właściwości funkcjonalnych systemów ETICS z okładziną nieciągłą, ze szczególnym uwzględnieniem zachowania obciążenia swobodnego. Przedmiotem dyskusji jest zewnętrzny system izolacji termicznej z płytką ceramiczną wyciętą z cegły, ułożoną na dwóch różnych podłożach, tj. wełnie mineralnej i styropianie. Podstawą oceny są zastosowane maksymalne obciążenie własne, maksymalna różnica przemieszczeń uzyskana dla omawianego rozwiązania podczas badań wykonanych w warunkach laboratoryjnych.
In the paper there was analyzed a mechanism of loss of functional properties of external thermal insulation composite system with discontinuous cladding, with particular emphasis on dead load behavior. The subject of discussion is the external thermal insulation composite system with a ceramic tile cut from brick, laid on two different substrates, i.e. wool and expanded polystyrene. The basis of the assessment are maximum dead load applied, maximum difference of displacement obtained during the tests made in laboratory conditions for the discussed solution.
Źródło:
Builder; 2020, 24, 3; 20-23
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zastosowania materiałów poliizocyjanurowych do izolacji przegród w systemowym budownictwie szkieletowym z drewna
Analysis of the applications of polyisocyanurate materials for the insulation of partitions in systemic frame construction
Autorzy:
Walerjańczyk, Mateusz
Ksit, Barbara
Powiązania:
https://bibliotekanauki.pl/articles/162009.pdf
Data publikacji:
2019
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
budownictwo szkieletowe
termoizolacja
materiał termoizolacyjny
pianka PIR
system STEICO
stropodach
para wodna
frame building
thermal insulation
thermal insulation material
PIR foam
STEICO system
flat roof
steam
Opis:
W artykule przedstawiono kilka przykładów rozwiązań termoizolacji przegród budowanych w systemie szkieletowym z drewna na przykładzie rozwiązań systemu (STEICO). Opisano istotę uwzględniania w projektowaniu przegród transferu pary wodnej przez ich strukturę oraz przeanalizowano przypadek zaprojektowania przegrody zamkniętej dyfuzyjnie z zastosowaniem materiałów z pianek PIR.
The article presents a few examples of thermal insulation solutions for partitions built in a timber frame system based on the example of (STEICO) system solutions. The essence of taking into consideration the design of water vapor transmission partitions through their structure was described and the case of designing a closed diffusion partition using PIR foam materials was analyzed.
Źródło:
Przegląd Budowlany; 2019, 90, 12; 48-51
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Systemy budownictwa z drewna księżycowego
Autorzy:
Kownacki, Dominik
Błaszczyński, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/162108.pdf
Data publikacji:
2019
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
drewno księżycowe
system budownictwa
Holz100
drewno lite
właściwości
przegroda zewnętrzna
współczynnik przenikania ciepła
izolacyjność akustyczna
moon wood
building system
solid wood
properties
building envelope
heat transfer coefficient
sound insulation characteristics
Opis:
W pracy opisane zostały dostępne systemy produkcji drewna litego wraz z przykładami ich zastosowania. Na podstawie systemu drewna litego, księżycowego, łączonego na kołki, Holz100 firmy Ing. Erwin Thoma Holz GmbH, przedstawiono parametry możliwe do uzyskania decydujące o wykorzystaniu tego materiału do budowy budynków zrównoważonych o możliwie najniższych parametrach termicznych.
Źródło:
Przegląd Budowlany; 2019, 90, 10; 110-114
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies