Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "insulation" wg kryterium: Temat


Tytuł:
Proper selection of thermal insulation materials
Autorzy:
El-Shiekh, T. M.
Elsayed, A.A.
Powiązania:
https://bibliotekanauki.pl/articles/385057.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
thermal insulation
insulation material
economic selection
Opis:
Thermal insulation plays a key role in the overall energy management picture. It is interesting to consider that by using the insulation, the entire energy requirements of a system are reduced. Since, the main function of insulation is to reduce the heat transfer, the insulation material must have the appropriate characteristic to retard the transport of heat occurred by conduction, convection and radiation. The proper selection and application of various insulation materials are very important in the domain of heat transfer. This paper discusses how to select thermal insulation material and on what basis a decision is made for application, concerning material selection and costs, through brief discussion about major insulation materials, properties, steps for economic selection, applications, economics of insulation and thickness, location, case study and conclusion.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 2; 42-46
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Possibility of Using Sewage Sludge Pellets as Thermal Insulation
Autorzy:
Kosiński, Piotr
Kask, Bartosz
Franus, Małgorzata
Piłat-Rożek, Magdalena
Szulżyk-Cieplak, Joanna
Łagód, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/2201921.pdf
Data publikacji:
2023
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pellets
thermal insulation
sewage sludge
thermal insulation materials
Opis:
The storage and disposal of sewage sludge from municipal wastewater treatment plants is becoming an increasing problem on a global scale. The attention of scientists is directed to the search for unique technologies to manage them. Firing sewage sludge in furnaces and producing lightweight aggregates and granules constitutes an innovative method of its disposal. The resulting granules could be a substitute for commonly used materials such as perlite, vermiculite, expanded clay, or LSA, and could be used as a secondary material in the construction industry, including road construction, as various types of ballast, and as an equivalent to aggregate in concretes. However, given that sewage sludge is increasingly used in biogas production, it does not completely decompose in the process and is still a problematic waste for many municipal treatment plants. Therefore, the use of sewage sludge pellets in construction, or any other industry, could revolutionize the market. The purpose of the conducted research was to evaluate the heat-insulating properties of granules produced from sewage sludge from the Municipal Wastewater Treatment Plant "Łyna" in Olsztyn used as a heat-insulating material.
Źródło:
Advances in Science and Technology. Research Journal; 2023, 17, 2; 161--172
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Budowlane materiały izolacyjne
Building insulation materials
Autorzy:
Jura, J.
Powiązania:
https://bibliotekanauki.pl/articles/2065412.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska
Tematy:
izolacja budynku
termoizolacja
hydroizolacja
building insulation
thermal insulation
waterproofing
Opis:
W artykule przedstawiono zagadnienia dotyczące izolowania przegród budowlanych. Opisano możliwe do zastosowania materiały izolacyjne wpływające na funkcjonowanie przegród budowlanych całego budynku. Scharakteryzowano pojawiające się na rynku nowe materiały termoizolacyjne. Przedstawiono możliwe do wykorzystania hydroizolacje pozwalające na ochronę budynku przed szkodliwym działaniem wody i przeciwdziałające niszczeniu elementów konstrukcyjnych.
The article presents issues of isolation of the building. It describes possible to use insulating materials and their impact on the functioning building envelope. New insulation material appearing on the construction industry market is characterized. It also presents available for use waterproofing to protect the building against the harmful water action and anti-destroying components.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2015, 2 (16); 39--44
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The study of sound and vibration isolating materials applicable environmental protection
Autorzy:
Sikora, J.
Targosz, J.
Powiązania:
https://bibliotekanauki.pl/articles/241841.pdf
Data publikacji:
2012
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
materials
acoustic insulation
vibroisolation
Opis:
Prevention of composite material, characterized by a high acoustic insulation but satisfying spread of the dynamic interactions in the environment, the sound or vibration in materials requires new solutions task of isolation between the source of noise and vibration and the environment. These new solutions based on the idea of partition (of two or multilayer), the cores of granular materials, characterized by both good characteristics vibroisolation, sound absorption and vibration-damping materials. Using these solutions brings positive results in the reduction of acoustic energy, vibration isolation and acoustic damping material provided that they are the correct selection. The paper presents results of experimental investigations of acoustic insulation properties, parameters, physic - mechanical properties of selected structural elements made of materials belonging to the latest generation of noise and vibration safe guards applicable in the work environment and external environment. The paper presents the methodology and results of new materials used in Cathedrals: Vibroacoustics and Mechanics and Robotics and Mechatronics AGH, which should be standard in the selection of the parameters of vibroacoustic properties of the newly proposed structural engineering. The work was carried out in a research project 4875/B/TO2/2010/38 financed by Ministry of Science and Higher Education and projectII.B.12 (2011-2013) "New material solutions in the design of layered Barriers vibroacoustic protection of machinery and equipment", which is one of the objectives of the multiannual program "Improving the safety and working conditions," coordinated by CIOP - PIB in Warsaw.
Źródło:
Journal of KONES; 2012, 19, 4; 555-564
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zależność efektywności energetycznej przegrody z izolacją transparentną od grubości izolacji
Dependence of energy efficiency of the building envelope with transparent insulation on insulation thickness
Autorzy:
Świrska-Perkowska, J.
Jęglet, K.
Powiązania:
https://bibliotekanauki.pl/articles/131580.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Komisja Inżynierii Budowlanej PAN Oddział w Katowicach
Tematy:
izolacja transparentna
grubość izolacji
bilans energetyczny
transparent insulation
insulation thickness
energy balance
Opis:
This paper presents a numerical model of an collecting-accumulating solar wall with transparent insulation. The objective of the simulation was to evaluate the energy efficiency of solar walls in the case of different insulation thicknesses. The calculations simulated daily temperature changes of the partition in January days with a different cloud cover (sunny day, moderate cloud cover day, cloudy day). As a result, temperature distributions in the wall with insulation of various thickness at different times of the process and the energy balance of the wall were obtained.
Źródło:
Roczniki Inżynierii Budowlanej; 2017, 17; 15-26
1505-8425
Pojawia się w:
Roczniki Inżynierii Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka i dobór izolacji cieplnych w przegrodach zewnętrznych z punktu widzenia bezpieczeństwa cieplnego
Characteristics and selection of thermal isolation the external walls with respect heat safety
Autorzy:
Wyleciał, T.
Zajemska, M.
Wyczółkowski, R.
Pyrek, R.
Powiązania:
https://bibliotekanauki.pl/articles/103717.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Humanistyczno-Przyrodniczy im. Jana Długosza w Częstochowie. Wydawnictwo Uczelniane
Tematy:
izolacja cieplna
przewodzenie ciepła
materiały izolacyjne
heat insulation
heat conduction
insulation materials
Opis:
Izolacja cieplna powinna chronić obiekt przed stratami ciepła, przed jego napływem, a także stanowić materiał spełniający bezpieczeństwo i komfort cieplny. W artykule przedstawiono szczegółową analizę wybranych materiałów pochodzenia organicznego, nieorganicznego oraz z tworzyw sztucznych. Zakres pracy obejmował przeprowadzenie obliczeń, które pozwoliły wyznaczyć hierarchie użyteczności izolacji cieplnych w obiektach budowlanych, a także określić przenikanie i przewodzenie ciepła.
Thermal insulation should protect property against both heat loss, before the influx, as well as provide material that meets the security and comfort. The article presents a detailed analysis of selected materials of organic origin, inorganic and plastic. The scope of work included carrying out calculations that helped determine the usefulness of hierarchies of thermal insulation in buildings, as well as the determination of diffusion and heat conduction.
Źródło:
Prace Naukowe Akademii im. Jana Długosza w Częstochowie. Technika, Informatyka, Inżynieria Bezpieczeństwa; 2014, T. 2; 439-446
2300-5343
Pojawia się w:
Prace Naukowe Akademii im. Jana Długosza w Częstochowie. Technika, Informatyka, Inżynieria Bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An analysis of the influence of microclimate on partial discharge activity in emissions of electric machines in the conditions of industrial operation – own research
Autorzy:
Plutecki, Z.
Szymaniec, S.
Powiązania:
https://bibliotekanauki.pl/articles/141042.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
HV electrical machines
partial discharge in winding insulation
on-line insulation diagnosis
microclimate
Opis:
The article presents the results of diagnostic measurements of partial discharge signal propagation from the winding insulation in electrical machinery, which were performed using an on-line method. This paper describes the results of experiments and the acquired experience in the monitoring of winding insulation in high power and high voltage electrical machines which are important in industrial production processes. The authors show the measurement techniques employed in their research. Representative measurement results are presented along with their analysis. The authors use an SKF monitoring systems to measure: vibrations, temperature, and humidity, as major factors affecting partial discharge activity in the from winding insulation of electrical machines.
Źródło:
Archives of Electrical Engineering; 2013, 62, 4; 629-648
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transparent insulation materials market in Europe
Autorzy:
Radziszewska-Zielina, Elżbieta
Kuraj, Filip
Powiązania:
https://bibliotekanauki.pl/articles/118592.pdf
Data publikacji:
2020
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
survey study
transparent insulation
market
Opis:
This paper presents the European market of transparent insulation materials as viewed by manufacturers. The objective of the study was to analyse the application of transparent insulation materials in the construction sector across Europe, determine the popularity of various technologies and materials used to manufacture them, the competition among transparent insulation manufacturers, investment in the development of new transparent insulation technologies, and trends in demand for transparent insulation in Europe. The analysis was performed on the basis of a survey of manufacturers. The use of transparent insulation is associated with high cost, yet the potential return on investment in the form of savings over the course of a building’s life-cycle convinces many potential developers to apply these materials. Based on the results of the survey, it can be concluded that European companies follow the increase in energy-efficiency and the transparent insulation market is prosperous, yet differs from country to country. It was observed that the positive perception of indirect heat gain transparent insulation systems was the most prevalent in Germany. The paper also explores the situation on the author’s domestic market – the Polish transparent thermal insulation market.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2020, 29, 3; 377-387
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza metrologiczna układu do ciągłej kontroli stanu izolacji obiektu
Metrological analysis of on-line electrical insulation monitoring circuit
Autorzy:
Rochiński, P.
Guzik, J.
Powiązania:
https://bibliotekanauki.pl/articles/153088.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
izolacja elektryczna
ciągła kontrola stanu izolacji
electrical insulation
on-line monitoring of electrical insulation
Opis:
W pracy przedstawiono koncepcję i możliwe struktury układu do ciągłej kontroli stanu izolacji obiektu w 3-fazowej sieci uziemionej prądu przemiennego. Zaprezentowano i przeanalizowano także podstawowe właściwości metrologiczne omawianego układu (tj. jego czułość bezwzględną |S| i względną niepewność standardową urel (Ri) oszacowania wartości rezystancji izolacji Ri). Przedstawiono wyniki wybranych symulacji komputerowych, przeprowadzonych z uwzględnieniem dynamiki rezystancji upływowej.
In this paper the concept and possible two circuit structures for on-line monitoring of electrical insulation in a 3-phase AC grounded network are presented. The object of investigation is represented by leakage resistance. Increase in the leakage current value is the result of worsening the parameters characterising the investigated object electric insulation. There is shown the electrical insulation model in which the leakage resistance of a three-phase object is combination of leakage resistances of each phase. For on-line monitoring of electrical insulation (insulation resistance) of an AC object the authors used a DC signal (a source of DC voltage), while a test signal is the leakage current. Fig. 1 shows an electrical insulation monitoring circuit. For two positions of switch W (see. Fig. 1b, c) the insulation resistance values are described by Eqs. (3) and (5), respectively. Figs. 2-7 present chosen computer simulations which were carried out when taking into account the dynamics of leakage resistance. The most important metrological parameters (e.g. absolute sensitivity and insulation resistance relative standard uncertainty) of the presented circuit are analysed and presented, too. The proposed electrical insulation monitoring circuit makes the continuous insulation resistance measurement in a rough way (circuit structure of Fig. 1c) and exact way (circuit structure of Fig. 1b) possible with use of the standard resistance Rp. The insulation resistance measure-ment accuracy and linearity of the circuit transfer characteristics were good (see Figs. 3 - 5). The sensitivity of the presented insulation resistance monitoring circuit is high and directly propor-tional to the applied voltage value Eg.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 11, 11; 1274-1276
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka transformatorów olejowych hermetycznych i suchych
Diagnostics of hermetic and dry oil transformers
Autorzy:
Bernatt, Jakub
Gawron, Stanisław
Glinka, Tadeusz
Polak, Artur
Powiązania:
https://bibliotekanauki.pl/articles/2135015.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
transformator
izolacja główna
izolacja międzyzwojowa
badania diagnostyczne
transformer
main insulation
interturn insulation
diagnostic tests
Opis:
Diagnostyka transformatorów suchych i transformatorów olejowych hermetycznych obejmuje pomiar rezystancji uzwojeń, diagnostykę izolacji głównej i izolacji międzyzwojowej. Diagnostykę izolacji głównej przeprowadza się napięciem zmiennym i napięciem stałym. Napięciem zmiennym wykonuje się pomiar współczynnika stratności tgδ. Napięciem stałym przeprowadza się pomiar rezystancji R60, oraz w rozszerzonym zakresie badania polaryzacyjne. Badanie izolacji międzyzwojowej polega na rejestracji przebiegu napięcia na uzwojeniu po skokowym wyłączeniu prądu stałego.
Oil testing is not performed in hermetic oil transformers. Diagnostics of dry transformers and hermetic oil transformers include winding resistance measurement, diagnostics of main insulation and turn-to-turn insulation. Main insulation diagnostics are performed with alternating voltage and direct voltage. The loss factor tgδ is measured with the alternating voltage. The resistance R60, is measured with direct voltage, and in the extended range of polarization tests. The test of interturn insulation is based on the registration of the voltage waveform on the winding after a DC switching off.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2022, 3, 1 (127); 21--27
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wielokryterialna analiza porównawcza warstw izolacyjnych współczesnych dachów stromych
Multiple-criteria comparative analysis of the insulation layers in modern pitched roofs
Autorzy:
Drozd, W.
Powiązania:
https://bibliotekanauki.pl/articles/162150.pdf
Data publikacji:
2012
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
dach stromy
warstwa izolacyjna
izolacja cieplna
izolacja paroszczelna
analiza porównawcza
analiza wielokryterialna
pitched roof
insulation layer
thermal insulation
damp insulation
comparison analysis
multicriteria analysis
Opis:
Artykuł porusza problematykę związaną z izolowaniem współczesnych dachów skośnych. Podjęto w nim próbę porównania pod względem różnych kryteriów rozwiązań hydro i termoizolacji. Analizą objęto materiały izolacyjne różnych firm, dostępne obecnie na rynku budowlanym. Rozpatrzono parametry mające wpływ zarówno na trwałość izolacji, jak również łatwość montażu. Uwzględniono także koszt zakupu omawianych materiałów.
This article addresses issues relating to the insulation of modern pitched roofs. It attempts to compare, based on various criteria, some solutions used for water insulation and thermal insulation. The analysis covers insulation materials currently marketed by various firms. Parameters were considered which have an impact on both the durability of the insulation and the ease of installation. The purchase cost of the materials was also taken into consideration.
Źródło:
Przegląd Budowlany; 2012, R. 83, nr 9, 9; 24-27
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka izolacji zwojowej
Diagnostic tests of condition of turn-to-turn insulation
Autorzy:
Decner, Adam
Polak, Artur
Powiązania:
https://bibliotekanauki.pl/articles/2142554.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
izolacja zwojowa
diagnostyka izolacji
metoda fali rozmytej
maszyna elektryczna
turn insulation
insulation diagnosis
electric machines
Opis:
Badania diagnostyczne stanu izolacji zwojowej metodą fali rozmytej polegają na wyłączeniu prądu w obwodzie z badaną cewką lub uzwojeniem. Generuje to falę napięciową, którą można zaobserwować na zaciskach cewki lub uzwojenia. Częstotliwość generowanego napięcia zależy od parametrów uzwojenia i może służyć do porównywania stanu technicznego badanych cewek lub uzwojeń.
Diagnostic tests of condition of turn-to-turn insulation, using the method of fuzzy wave is based on breaking the current in the circuit with tested coil or winding. This generates a voltage wave, which can be observed on terminals of coil or winding. The frequency of generated voltage depends on the parameters of the winding and can be used to compare the technical condition of tested coils or windings.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2022, 3, 1 (127); 179--181
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The significance of marketing for the development of research and development institutions. Experiences of the the Research and Development Centre for Building Insulation Industry
Autorzy:
Śmiszek-Lindert, W.
Miros, A.
Powiązania:
https://bibliotekanauki.pl/articles/213917.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
marketing
research institutions
building insulation industry
Opis:
Experiences of the The Research and Development Centre for Building Insulation Industry in the development of research and development institutions is described in this article. Reasons for cooperation of R&D institutions and the business environment are explained. Promotional activity of the Research and Development Centre for Building Insulation Industry aie revealed and analysed.
Źródło:
Prace Instytutu Lotnictwa; 2012, 6 (227); 249-261
0509-6669
2300-5408
Pojawia się w:
Prace Instytutu Lotnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Streaming electrification of insulating liquid mixtures
Autorzy:
Zdanowski, Maciej
Maleska, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/141677.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
dielectric liquids
streaming electrification
transformer insulation
Opis:
Extensive efforts have been made for many years by the power generating industry to replace conventional solid and liquid insulation with synthetic materials. Those measures are aimed at increasing the load capacity, improved fire safety and extending transformer life during exploitation. Modern insulating materials include aramid fibre-based paper and insulating fluids made of synthetic and natural esters. The paper presents research results of the electrostatic charging tendency (ECT) of mixtures of fresh and aged mineral oil Trafo En with synthetic ester Midel 7131 and natural ester Midel 1204. The measurements were taken in a flow-through system using the pipes made of metal, cellulose and aramid paper. The influence of the liquid flow velocity, the type of material of the measuring pipe and the mixture content on the level of the streaming electrification current generation was determined.
Źródło:
Archives of Electrical Engineering; 2019, 68, 2; 387-397
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Diffusing Elements in a Reverberation Room on the Results of Airborne Sound Insulation Laboratory Measurements
Autorzy:
Mleczko, Dominik
Wszołek, Tadeusz
Powiązania:
https://bibliotekanauki.pl/articles/177423.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
reverberation room
airborne sound insulation
diffuseness
Opis:
The main problem in the measurement of airborne sound insulation is the measurement of the sound power radiated by the barrier, in practice performed by measuring the sound pressure level and the acoustic absorption in the receiving room. Large variations of the sound pressure level in a reverberation room indicate the presence of dominating strong standing waves, so that it becomes necessary to install diffusing elements. In ISO 10140, the limits have been defined in which the reverberation time at frequencies at and above 100 Hz should be included. Sometimes, however, in the case of rooms with a large volume, obtaining the required parameters is difficult and sometimes even impossible. It should then be checked whether the measured sound insulation depends on the reverberation time. The paper presents the results of sound insulation measurements at various reverberation time lengths in subsequent stages of diffusing elements installation in the receiving room. An analysis of diffusing materials amount and arrangement influence on the uniformity of the sound pressure level distribution and reverberation time in the room as well as the value of the measured sound insulation was carried out. Uncertainty of sound insulation measurement with partial uncertainties was adopted as a criterion supporting the assessment of the obtained results.
Źródło:
Archives of Acoustics; 2019, 44, 4; 739-746
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The energy parameters of formation of the porous structure
Autorzy:
Koshlak, H. V.
Pavlenko, A.
Piotrowski, J. Z.
Powiązania:
https://bibliotekanauki.pl/articles/402161.pdf
Data publikacji:
2016
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
thermal conductivity
porosity
swelling
heat insulation
Opis:
Research porosity thermal insulation of refractory materials is the important task of power engineering, because the thermal conductivity of porous materials depends on the shape and especially location of pore. Analytical review of existing technologies shows that research in this area is focused on the study of a process separately and generalized theories are not sufficient to clear analysis and model building process heat mass transfer of alumina porous material.
Źródło:
Structure and Environment; 2016, 8, 3; 206-210
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Materials Resistant to High Temperatures Obtained from Post-Production Fibrous Waste
Autorzy:
Kogut, K.
Kasprzyk, K.
Kłoś, R.
Powiązania:
https://bibliotekanauki.pl/articles/355061.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
waste
thermal insulation
ceramic
porosity
fibers
Opis:
This paper describes preparation methodology and research results of newly developed materials from post-production fibrous waste that are resistant to high temperatures. Widely available raw materials were used for this purpose. Such approach has significant impact on the technological feasibility and preparation costs. Obtained materials were verified via applying of various tests including characterization of shrinkage, porosity, density and water absorption as well as X-ray analysis (XRD), followed by mechanical bending and compressive strength determination. Based on the research results, the possible applications of materials as thermal insulators were indicated.
Źródło:
Archives of Metallurgy and Materials; 2020, 65, 2; 845-850
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Possibility of Limiting the Impact of Ground Vibrations Caused During Demolition of a Towers on Environment
Autorzy:
Targosz, J.
Bednarz, J.
Lisowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/177131.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ground vibrations
insulation layers
vibrations measurements
Opis:
Before disassemble and demolition of five granulation towers the authors planned and carried out measurements of the intensity of vibrations induced during the fall of the dismantled components of towers on the ground. The main aim of the study was to determine the maximum permissible weight of falling elements of the towers during the demolition, in terms of ensuring the protection of buildings and equipment located in the vicinity of the works. It was unacceptable to increase the vibration amplitudę displacement in each section of measurement on each of the three perpendicular axes by more than 2 µm peak-to-peak value and the absolute velocity of RMS of vibration amplitude couldn’t be increased by more than 1 mm/sec value than the background vibration during the demolition of the towers. Preliminary experimental studies were conducted on a test stand and the measurements were made on the real object. The amplitudes of vibration waves displacement and velocity were recorded on the measurement section in the direction of the protected building. The results of measurements were used to identify the propagation of the shock wave and the effectiveness of the proposed insulation layers.
Źródło:
Archives of Acoustics; 2016, 41, 4; 649-657
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ błędów wykonawczych na trwałość systemu docieplenia metodą ETICS
Influence of construction defects on durability of external thermal insulation composite system ETICS
Autorzy:
Kysiak, A.
Powiązania:
https://bibliotekanauki.pl/articles/2065373.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska
Tematy:
system docieplenia
metoda ETICS
wady robót dociepleniowych
external thermal insulation composite system
faulty insulating works
insulation system
Opis:
Artykuł przedstawia najczęstsze wady wykonania docieplenia ścian budynków metodą ETICS. Omówione zostało zagadnienie wpływu uszkodzeń poszczególnych elementów systemu ociepleniowego na jego trwałość i odporność.
The article presents the most frequent defects in insulation of building walls by light wet method. There was discussed the issue of the impact of damage specific elements of the insulation system on durability and resistance of the ETICS.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2014, 2 (14); 29--37
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Opracowanie nowych technologii wykonywania izolacji cieplnych w energetyce
New, environmentally friendly technologies of thermal insulation for power industry
Autorzy:
Witek, J.
Klecan, R.
Kleta, A.
Śliwa, A.
Powiązania:
https://bibliotekanauki.pl/articles/392480.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
przemysł energetyczny
materiał termoizolacyjny
izolacja ognioodporna
izolacja turbin
power industry
thermal insulating material
fireproof insulation
turbine insulation
Opis:
Opracowano nowe ognioodporne materiały termoizolacyjne wielokrotnego użycia, służące do izolacji cieplnej turbin i rurociągów pary przegrzanej w energetyce zawodowej. Wyroby te pozwalają zmienić technologię izolowania turbin i rurociągów pary przegrzanej, a w efekcie obniżyć koszty remontów, zdecydowanie poprawić warunki pracy ekip remontowych oraz wyeliminować problem powstawania, stwarzających duże zagrożenie ekologiczne, odpadów włóknistych.
New, fireproof insulation materials of the repeated use for thermal insulation of power station turbines and superheated steam pipelines were developed. This products allow to change the technology of turbines and superheated steam pipelines insulations and consequently to lower costs of repairs, improvement of repair teams working conditions and elimination the problem of generation of dangerous fibrous waste materials.
Źródło:
Prace Instytutu Szkła, Ceramiki, Materiałów Ogniotrwałych i Budowlanych; 2009, R. 2, nr 3, 3; 101-113
1899-3230
Pojawia się w:
Prace Instytutu Szkła, Ceramiki, Materiałów Ogniotrwałych i Budowlanych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wielowariantowa analiza termoizolacji od wewnątrz występujących na polskim rynku
Autorzy:
Ksit, Barbara
Jankowiak, Magdalena
Powiązania:
https://bibliotekanauki.pl/articles/161150.pdf
Data publikacji:
2019
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
termoizolacja wewnętrzna
system ocieplania
para wodna
wytyczne
DIN 4108-2
internal thermal insulation
insulation system
steam
guidelines
Opis:
W artykule przedstawiono klasyfikacje systemów izolacji termicznych od wewnątrz. Zaprezentowano wybrane rozwiązania i ich parametry techniczne oraz zawarto analizę dyfuzyjnie otwartych i zamkniętych systemów występujących na rynku polskim. Zebrano wszystkie wytyczne prawne dotyczące ocieplania budynku według wymagań zawartych w DIN 4108-2 dla nieprzezroczystych powierzchni płaskich o masie powierzchniowej większej od 100 kg/m2 i o masie powierzchniowej do 100 kg/m2 oraz według dokumentów UE. Zestawiono porównanie systemów termoizolacyjnych od wewnątrz, pod względem wybranych parametrów technicznych.
Źródło:
Przegląd Budowlany; 2019, 90, 10; 99-102
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ jakości wykonania szyb zespolonych na zachowanie ich parametrów użytkowych
The impact of quality performance insulating glass units to preserve their usefull parameters
Autorzy:
Balon-Wróbel, A.
Marczewska, A.
Powiązania:
https://bibliotekanauki.pl/articles/168902.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
szyba zespolona
właściwości użytkowe
izolacyjność cieplna
izolacyjność akustyczna
insulating glass unit
utility properties
thermal insulation
acoustic insulation
Opis:
Budownictwo pasywne wymaga zastosowania energooszczędnych wyrobów budowlanych. Dążenie do osiągnięcia wysokiej izolacyjności cieplnej przegród przezroczystych w budynkach znajduje odzwierciedlenie w produkcji szyb zespolonych stosowanych w tych przegrodach. Ważne jest, aby szyby zamontowane w obiekcie (oknie) były wysokiej jakości, gdyż tylko wtedy będą mogły spełniać swoją rolę. W artykule omówiono podstawowe funkcje izolacyjnych szyb zespolonych, wymagania normatywne oraz metody ich kontroli. Przedstawiono jakość izolacyjnych szyb zespolonych oraz czynnik wpływający na uzyskanie przez te materiały najkorzystniejszych parametrów użytkowych.
Passive construction requires the use of energy-efficient building materials. Striving to achieve high thermal insulation of buildings is reflected also in the production of insulating glass units. It is important that the glass installed in the building were of high quality because only then will be able to perform its function. The article discussed the basic functions insulating glass units, normative requirements and methods of their control. Presented quality insulating glass units and a factor in obtaining these materials good performance characteristics.
Źródło:
Szkło i Ceramika; 2015, R. 66, nr 4, 4; 9-12
0039-8144
Pojawia się w:
Szkło i Ceramika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania i możliwości zastosowań mikrosfer z popiołów lotnych
The research results and application possibilities of fly ash microspheres
Autorzy:
Łach, M.
Mikuła, J.
Powiązania:
https://bibliotekanauki.pl/articles/134734.pdf
Data publikacji:
2016
Wydawca:
ADVSEO
Tematy:
fly ashes
microspheres
insulation materials
alkali activation
Opis:
The paper presents a short description of aluminosilicate materials which are microspheres derived from fly ash from coal combustion in power stations. The most important properties of such materials, the conditions of their formation, methods of obtaining and selected areas of application are discussed. The microspheres that were tested came from the Power Plant Skawina. Analysis of particle size and wall thickness of the microspheres and the analysis of the chemical composition have been carried out. This article also presents preliminary results of the alkaline activation of the microspheres in order to obtain a fraction within the zeolite. Alkali activation was carried out in several variants, using aqueous solutions of sodium hydroxide and the obtained results allow to determine the suitability of the microspheres to obtain zeolites in their substrate. Observations with the scanning electron microscope showed the existence of significant quantities of specific forms of zeolites, after alkaline activation processes of microspheres.
Źródło:
Technical Issues; 2016, 3; 74-78
2392-3954
Pojawia się w:
Technical Issues
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System of Signal Injection and Extractioo for Protection and Insulation Monitoring in Medium Voltage Networks
Autorzy:
Kyrychenko, M.
Habrych, M.
Powiązania:
https://bibliotekanauki.pl/articles/410612.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
insulation
distribution network
ground fault
signal injection
Opis:
Simple overcurrent criterion is most often used for detection and elimination of ground faults in radial industrial medium voltage networks. Since in Poland medium voltage networks work with noneffectively grounded neutral point, the ground fault currents can reach very low values, especially under high resistance faults. Such faults cannot be detected by any protection. Therefore, new methods to detect ground faults and to control the insulation in medium voltage network are of great importance. In the paper the idea for monitoring insulation parameters of the system, based on the simultaneous use of two different signals of non-industrial frequency, injected into the controlled network, is presented and discussed.
Źródło:
Present Problems of Power System Control; 2017, 8; 23-30
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal insulating cover for the metal body of a rocket motor
Osłona termoizolacyjna metalowego korpusu silnika rakietowego
Autorzy:
Borkowska, Małgorzata
Mężyński, Jan
Moskalewicz, Maciej
Rasztabiga, Tomasz
Tulik, Marek
Powiązania:
https://bibliotekanauki.pl/articles/1065044.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
thermal insulation
rocket motor
termoizolacja
silnik rakietowy
Opis:
Wieloletnie doświadczenie firmy BUMAR AMUNICJA S.A. w zakresie konstrukcji i technologii produkcji amunicji i rakiet, pozwoliło na podjęcie się zadania, wspólnie z Instytutem IMPiB Oddziału Elastomerów i Technologii Gumy w Piastowie, stworzenia zmodernizowanej osłony termoizolacyjnej do metalowego korpusu silnika rakietowego do wyrobu GROM-M. Warstwa izolacyjna metalowego korpusu silnika rakietowego charakteryzuje się tym, że miejscowe narażenia termiczne występujące w czasie spalania paliwa rakietowego, często wywołują miejscowe przepalenia korpusu silnika. W przypadku zastosowanego składu warstwy izolacyjnej zależnie od temperatury spalania w danym miejscu silnika wywołują odpowiedni dla tej temperatury przebieg procesu karbonizacji. Zapewniając tym samym wystarczającą w tym miejscu warstwę kompozytu fazy węgiel-węgiel zwiększającą wytrzymałość silnika oraz zabezpieczającą wspomniany metalowy korpus przed narażeniem termicznym w czasie spalania paliwa rakietowego. Warstwa termoizolacyjna silnika rakietowego jest powłoką dwuwarstwową składającą się z warstwy mieszanki kauczukowej i warstwy impregnowanej tkaniny węglowej. Dla uzyskania jednolitej struktury warstwy izolacji i jej odporności termicznej, w składzie mieszanki kauczukowej i w mieszance kauczukowej do impregnacji kompozytu na bazie tkaniny węglowej stosowane są podobne składniki: ten sam typ kauczuku, ta sama żywica fenolowo-formaldehydowa oraz te same substancje wulkanizacyjne.
Źródło:
Materiały Wysokoenergetyczne; 2019, 11, 1; 31-38
2083-0165
Pojawia się w:
Materiały Wysokoenergetyczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Osłona termoizolacyjna metalowego korpusu silnika rakietowego
Thermal insulation shield of metal body of the rocket motor
Autorzy:
Borkowska, M.
Mężyński, J.
Moskalewicz, M.
Rasztabiga, T.
Tulik, M.
Powiązania:
https://bibliotekanauki.pl/articles/92784.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
termoizolacja
silnik rakietowy
thermal insulation
rocket motor
Opis:
Wieloletnie doświadczenie firmy BUMAR AMUNICJA S.A. w zakresie konstrukcji i technologii produkcji amunicji i rakiet, pozwoliło na podjęcie się zadania, wspólnie z Instytutem IMPiB Oddziału Elastomerów i Technologii Gumy w Piastowie, stworzenia zmodernizowanej osłony termoizolacyjnej do metalowego korpusu silnika rakietowego do wyrobu GROM-M. Warstwa izolacyjna metalowego korpusu silnika rakietowego charakteryzuje się tym, że miejscowe narażenia termiczne występujące w czasie spalania paliwa rakietowego, często wywołują miejscowe przepalenia korpusu silnika. W przypadku zastosowanego składu warstwy izolacyjnej zależnie od temperatury spalania w danym miejscu silnika wywołują odpowiedni dla tej temperatury przebieg procesu karbonizacji. Zapewniając tym samym wystarczającą w tym miejscu warstwę kompozytu fazy węgiel-węgiel zwiększającą wytrzymałość silnika oraz zabezpieczającą wspomniany metalowy korpus przed narażeniem termicznym w czasie spalania paliwa rakietowego. Warstwa termoizolacyjna silnika rakietowego jest powłoką dwuwarstwową składającą się z warstwy mieszanki kauczukowej i warstwy impregnowanej tkaniny węglowej. Dla uzyskania jednolitej struktury warstwy izolacji i jej odporności termicznej, w składzie mieszanki kauczukowej i w mieszance kauczukowej do impregnacji kompozytu na bazie tkaniny węglowej stosowane są podobne składniki: ten sam typ kauczuku, ta sama żywica fenolowo-formaldehydowa oraz te same substancje wulkanizacyjne.
Many years of experience of BUMAR AMUNICJA SA in the design and manufacturing technology of ammunition and rockets, allowed to together with the Institute IMPiB Department Elastomers and Rubber Technology in Piastów to take up the task to create an upgraded insulation shield of the metal body of the rocket motor for GROM-M. The insulating layer of metal body of the rocket motor characterizes with the local thermal exposure occurring during rocket propellant combustion, often causes local a burn to the engine body. In the case of the insulating layer composition used depending on the temperature of combustion in the engine the rocket propellant produces a site suitable for the temperature carbonization process. Thereby providing sufficient in this point, carboncarbon phase of the composite layer. It contributes to the strength of the motor and securing given metal body before exposure to heat during combustion of the rocket propellant. The thermal insulating layer of the rocket motor is a two-layer coating comprising a layer of rubber compound and a layer of impregnated carbon cloth. To obtain a uniform structure of the insulating layer and the heat resistance, the composition of the rubber mixture and the rubber mixture for the treatment of composite carbon-based fabrics are used in similar elements: the same type of rubber, the same phenol-formaldehyde resin and the vulcanization of the same substances.
Źródło:
Materiały Wysokoenergetyczne; 2013, T. 5; 78-84
2083-0165
Pojawia się w:
Materiały Wysokoenergetyczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zastosowania wibroizolacji w podrozjazdnicach na rozjazd
Effect of vibration insulation in sleepers onturnout
Autorzy:
Kwiatkowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/249033.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Komunikacji Rzeczpospolitej Polskiej
Tematy:
rozjazd
wibroizolacja
USP
rail turnout
vibration
insulation
Opis:
Praca poświęcona jest możliwości zastosowania podkładek na spodniej powierzchni podrozjazdnic. W opracowaniu zamieszczono wytyczne stosowania wibroizolacji na spodniej powierzchni podrozjazdnic strunobetonowych na liniach kolejowych stosowanych na kolejach austriackich i niemieckich. W pracy przedstawiono wstępne wyniki analizy wpływu zastosowania wibroizolacji w podrozjazdnicach strunobetonowych na rozjazd.
The possibility of using pads on the underside of sleepers has been presented in the paper. The study contains guidelines for the application of vibration isolation on the underside of prestressed concrete sleepers being in force on Austrian and German railways. The paper presents preliminary results of the analysis of the impact of the application of vibration isolation in prestressed concrete sleepers on the turnout.
Źródło:
Zeszyty Naukowo-Techniczne Stowarzyszenia Inżynierów i Techników Komunikacji w Krakowie. Seria: Materiały Konferencyjne; 2015, 2(106); 115-122
1231-9171
Pojawia się w:
Zeszyty Naukowo-Techniczne Stowarzyszenia Inżynierów i Techników Komunikacji w Krakowie. Seria: Materiały Konferencyjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling and Experimental Verification of Ultrasound Transmission in Electro Insulation Oil
Autorzy:
Wotzka, D.
Cichoń, A.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/177158.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasound transmission
numerical simulations
electro-insulation oil
Opis:
A verification study of ultrasound transmission numerical simulation results with experiment results is presented in this paper. The work considers a model of a transformer tank which is filled with electro insulating oil. In the experiment, performed under laboratory conditions, an ultrasound wave is generated by a piezoelectric transducer that is fixed in the centre of the tank and measured by another transducer mounted inside the tank at three distances: 10, 20 and 30 cm from the sound source. The transducer is able to measure and generate acoustic waves in the ultrasound frequency band up to 1 MHz. The simulation considers numerical calculation of acoustic pressure distribution inside the tank in which acoustic source emits waves with frequency equal to 100 kHz. Verification analysis has confirmed consistency of the numerically calculated values with the measurement results.
Źródło:
Archives of Acoustics; 2012, 37, 1; 19-22
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring of Partial Discharges in Cable Insulation and Cable Head Using Acoustic Method
Autorzy:
Ranachowski, Zbigniew
Wieczorek, Krzysztof
Ranachowski, Przemysław
Dębowski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2141672.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
partial discharges
medium voltage insulation
acoustic emission
Opis:
The article presents the application of Acoustic Emission (AE) method for detection and registration of partial discharges (PD) generated in medium voltage (MV) cable isolation and MV cable head. The insulation of the high voltage cable is made of a flexible material whose properties are characterised by a high coefficient of attenuation of the acoustic signals. For this reason, the AE method has not been used so far to detect PD in energetic cables. The subjects of the research were the MV cable and the standard T-type cable head. The cable contained defects which were the source of partial discharges. In case of cable head the PD were provoked by thin grounded electrode which was introduced into connector opening. The results of AE measurements are presented in the form of spectrograms. Acoustic Emission was evoked when the applied voltage level reached the value of 7.5 kV for the cable and 4 kV for the cable head. The authors used the acoustic instrumentation of their own design intended for future field use. Obtaining successful results of partial discharges measurements using the acoustic method in the cable insulation makes an original contribution of the presented work.
Źródło:
Archives of Acoustics; 2022, 47, 2; 259-265
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal Insulation and Mechanical Properties in the Presence of Glas Bubble in Fly Ash Geopolymer Paste
Autorzy:
Shahedan, Noor Fifinatasha
Abdullah, Mohd Mustafa Al Bakri
Mahmed, Norsuria
Liew, Yun Ming
Shayfull, Zamree Abd Rahim
Aziz, Ikmal Hakem A.
Kadir, Aeslina Abdul
Sandu, Andrei Victor
Ghazali, Mohd Fathullah
Powiązania:
https://bibliotekanauki.pl/articles/2048833.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
glass bubble
thermal insulation
geopolymers
fly ash
Opis:
The density, compressive strength, and thermal insulation properties of fly ash geopolymer paste are reported. Novel insulation material of glass bubble was used as a replacement of fly ash binder to significantly enhance the mechanical and thermal properties compared to the geopolymer paste. The results showed that the density and compressive strength of 50% glass bubble was 1.45 g/cm3 and 42.5 MPa, respectively, meeting the standard requirement for structural concrete. Meanwhile, the compatibility of 50% glass bubbles tested showed that the thermal conductivity (0.898 W/mK), specific heat (2.141 MJ/m3 K), and thermal diffusivity (0.572 mm2 /s) in meeting the same requirement. The improvement of thermal insulation properties revealed the potential use of glass bubbles as an insulation material in construction material.
Źródło:
Archives of Metallurgy and Materials; 2022, 67, 1; 221-226
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania eksperymentalne dotyczące wykorzystania metod stałoprądowych do diagnostyki izolacji maszyn elektrycznych
Experimental Tests Electrical Insulation of Electrical Machines Using Direct Current Measurement Methods
Autorzy:
Ławrowski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/1368331.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik indukcyjny
izolacja uzwojeń
diagnoza
metoda WMPS
współczynnik kondycji izolacji
wytrzymałość izolacji
wyładowań niezupełnych
Ramp Test
motor induction
winding insulation
diagnosis
method WMPS
diagnostic factor for insulation
insulation strength
partial discharges
Opis:
The paper will be presented the results of destructive isolation of high-power induction motors using different diagnostic methods on the same object. The purpose of these tests is to look for correlations that result in getting a good diagnosis.
W artykule zostaną przedstawione wyniki badań niszczących izolacji silników indukcyjnych dużych mocy z wykorzystaniem różnych metod diagnostycznych na tym samym obiekcie. Celem tych badań jest poszukiwanie wzajemnych korelacji, których skutkiem jest otrzymanie trafnej diagnozy.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 2, 99; 271-276
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Proektirovanie svetoprozracnyh orgazdenij energoeffektivnyh zdanij
Design of exterior glass constructions for energy efficient buildings
Autorzy:
Sergejcuk, O.
Powiązania:
https://bibliotekanauki.pl/articles/2065210.pdf
Data publikacji:
2013
Wydawca:
Politechnika Częstochowska
Tematy:
energy efficient buildings
windows
natural lighting
insolation
sun protection
sound insulation
heat insulation
budynki energooszczędne
okna
oświetlenie naturalne
nasłonecznienie
Opis:
Okna energoeffektivnyh zdanij dolzny udovletvorat’ mnogim usloviam, kasausciesa estestvennogo osvescenia, insolacii, zascita ot solnca, zvukoizolacii i teplozascity pomescenij. Eti uslovia vo mnogom avlautsa protivorecivymi. V stat’e analiziruutsa puti ulucsenia ukrainskih stroitel’nyh norm i standartov na proektirovanie svetoprozracnyh ograzdauscih konstrukcij v sovremennyh zdaniah.
Windows of energy efficient buildings must satisfy many conditions: relatively natural lighting, insolation, sun protection, sound insulation, and heat protection. These conditions are inconsistent in many respects. We analyze the ways how to improve the Ukrainian building regulations and standards on the design of windows in modern buildings.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2013, 2 (12); 103--109
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie laboratoryjne wybranych wypraw elewacyjnych w systemach ociepleń z zastosowaniem styropianu jako materiału termoizolacyjnego
Autorzy:
Konca, P.
Powiązania:
https://bibliotekanauki.pl/articles/362435.pdf
Data publikacji:
2005
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
wyprawy elewacyjne
styropian
materiał termoizolacyjny
ETICS (External Thermal Insulation Composite Systems)
layer facade plasters
foamed polystyrene
heat insulation material
Opis:
Wyprawy tynkarskie stosowane w zewnętrznych zespolonych systemach ocieplania ETICS (Extemal Thennal Insulation Composite Systems) ze styropianem znane są w naszym kraju od kilkunastu lat. Jednak w ostatnim czasie wprowadzono do stosowania nowe rodzaje wypraw tynkarskich. W referacie przedstawiono badania wybranych cech fizyko-mechanicznych jedenastu różnych zestawów cienkowarstwowych wypraw elewacyjnych, opartych na czterech różnych rodzajach tynków.
External Thermal Insulation Composite System s based on expanded polystyrene are well-known in our country from many years. New kin d s of plasterers expeditions were introduced to applying. Research of choose physical -mechanical eleven different sets of thin-layer material, leans on four different kinds of plasters, are presented in article.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2005, T. 1; 201-206
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka maszyn elektrycznych z magnesami trwałymi - metody wybrane
PM Electrical Machines Diagnostic - Selected Methods
Autorzy:
Barański, M.
Decner, A.
Powiązania:
https://bibliotekanauki.pl/articles/1368030.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
generator
magnesy trwałe
diagnostyka
drgania
izolacja główna
izolacja zwojowa
permanent magnets
diagnostics
vibration
main insulation
turn-to-turn insulation
Opis:
This article presents a several diagnostic methods that can be used to determine the technical condition of electrical machines, especially permanent magnets (PM) machines. Those machines are commonly used in small wind and water systems and vehicles drives. Those methods are preferred by the author in periodic diagnostic of electrical machines. The special attention should be paid for diagnostic methods of turn-toturn insulation and vibrations. Both of those methods were invented in the Institute of Electrical Drives and Machines Komel. Specific structural properties of machines excited by permanent magnets are used in vibration method - electromotive force (EMF) generated due to vibrations. Authors present similarity of machine excited by permanent magnets to electrodynamic sensor and the results of simulation and laboratory tests of electrical machine excited by permanent, in which an increased level of vibration was caused by unbalance.
Artykuł przedstawia metody diagnostyczne, które mogą być zastosowane do określenia stanu technicznego silników i generatorów z magnesami trwałymi, wykorzystywanymi, m.in. w elektrowniach wodnych i wiatrowych oraz napędach trakcyjnych pojazdów elektrycznych. Opisywane metody wykorzystywane są przez autorów w czasie okresowych badań diagnostycznych. W artykule zwrócono szczególną uwagę na metodę diagnostyki drganiowej oraz diagnostykę izolacji zwojowej, gdyż obie zostały opracowane w Instytucie KOMEL. Metoda dotycząca diagnostyki drganiowej wykorzystuje specyficzne właściwości konstrukcyjne maszyn ze wzbudzeniem od magnesów trwałych, mianowicie indukowanie się SEM pod wpływem drgań. Autorzy przedstawiają podobieństwo maszyny z magnesami trwałymi do czujnika elektrodynamicznego oraz wyniki symulacji i badań laboratoryjnych maszyn z magnesami trwałymi, w których zwiększony poziom wibracji spowodowany był niewywagą.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2015, 1, 105; 183-189
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka maszyn elektrycznych z magnesami trwałymi – wybrane metody
PM electrical machines diagnostic –selected methods
Autorzy:
Barański, M.
Decner, A.
Powiązania:
https://bibliotekanauki.pl/articles/302502.pdf
Data publikacji:
2016
Wydawca:
Wydawnictwo Druk-Art
Tematy:
generator
magnesy trwałe
diagnostyka
drgania
izolacja główna
izolacja zwojowa
permanent magnets
diagnostics
vibration
main insulation
turn-to-turn insulation
Opis:
Artykuł przedstawia metody diagnostyczne, które mogą być zastosowane do określenia stanu technicznego silników i generatorów z magnesami trwałymi, wykorzystywanych, m.in. w elektrowniach wodnych i wiatrowych oraz napędach trakcyjnych pojazdów elektrycznych. Opisywane metody wykorzystywane są przez autorów w czasie okresowych badań diagnostycznych. W artykule zwrócono szczególną uwagę na metodę diagnostyki drganiowej oraz diagnostykę izolacji zwojowej, gdyż obie zostały opracowane w Instytucie KOMEL. Metoda dotycząca diagnostyki drganiowej wykorzystuje specyficzne właściwości konstrukcyjne maszyn ze wzbudzeniem od magnesów trwałych, mianowicie indukowanie się SEM pod wpływem drgań. Autorzy przedstawiają podobieństwo maszyny z magnesami trwałymi do czujnika elektrodynamicznego oraz wyniki symulacji i badań laboratoryjnych maszyn z magnesami trwałymi, w których zwiększony poziom wibracji spowodowany był niewywagą.
This article presents a several diagnostic methods that can be used to determine the technical condition of electrical machines, especially permanent magnets (PM) machines. Those machines are commonly used in small wind and water systems and vehicles drives. Those methods are preferred by the author in periodic diagnostic of electrical machines. The special attention should be paid for diagnostic methods of turn-to-turn insulation and vibrations. Both of those methods were invented in the Institute of Electrical Drives and Machines Komel. Specific structural properties of machines excited by permanent magnets are used in vibration method - electromotive force (EMF) generated due to vibrations. Authors present similarity of machine excited by permanent magnets to electrodynamic sensor and the results of simulation and laboratory tests of electrical machine excited by permanent, in which an increased level of vibration was caused by unbalance.
Źródło:
Napędy i Sterowanie; 2016, 18, 5; 72-78
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przyczyny oraz najważniejsze skutki zawilgocenia izolacji transformatorów
Reasons for transformer insulation moistening and its most important effects
Autorzy:
Graczkowski, A.
Gielniak, J.
Walczak, K.
Bródka, B.
Powiązania:
https://bibliotekanauki.pl/articles/155794.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
izolacja transformatora
utlenianie celulozy
transformer insulation
cellulose oxidation
Opis:
W artykule przedstawiono najważniejsze przyczyny zawilgocenia izolacji. Omówiono rozkład chemiczny celulozy prowadzący do wydzielania wody. Przedstawiono wpływ zawilgocenia izolacji celulozowej na dynamikę starzenia termicznego, którego miarą jest stopień polimeryzacji. Omówiono wpływ zawilgocenia izolacji na zjawiska ważne z punktu widzenia eksploatacji transformatorów.
A problem of power transformer insulation moistening is very important. High level of moisture in paper insulation is responsible for decreasing mechanical and electrical strength, and also it can generate very dangerous phenomena like e.g. bubble effect. The authors collected all important information that allows understanding a mechanism of water generation in paper-oil insulation. The analysis of the processes on the material structure level allows also explaining how the process of cellulose aging results in degradation of power transformer functionality. The first part of the paper presents the process of cellulose chemical decomposition, especially as a result of oxidation. Figure 4 shows various reactions of cellulose oxidation. This process is the main source of water particle creation and leads to decreasing the cellulose chain length (DP - Degree of Polymerization) and, in consequence, the mechanical strength of paper. An important factor which accelerates the decomposition process is temperature. High temperature is also responsible for gas formation in oil-paper insulation. In the second part of the paper the influence of insulation moistening on processes important for transformer operation is described. Among others, there are mentioned the most crucial effects such as: bubble formation, increase in dielectric losses and partial discharges activity, decrease in mechanical properties and deterioration of oil quality. Taking into consideration the all described aspects, the authors conclude that the moistening level of power transformer insulation should be monitored as a very important factor determining its exploitation.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 1, 1; 41-43
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przykład termoizolacji przegród zewnętrznych obiektu zabytkowego w technologii Multipor
Example of thermal insulation envelope historic object technology MULTIPOR
Autorzy:
Zalewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/132010.pdf
Data publikacji:
2016
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
termoizolacja
Multipor
budynki zabytkowe
insulation
MULTIPOR
historical buildings
Opis:
W przypadku budynków o charakterze zabytkowym, objętych opieką konserwatorską, poprawa izolacyjności cieplnej przegród zewnętrznych jest możliwa jedynie poprzez ich docieplenie od strony wewnętrznej. Do termoizolacji ścian zewnętrznych obiektów zabytkowych chętnie jest stosowany system Multipor firmy Xella wykorzystujący mineralne płyty izolacyjne wykonane z bardzo lekkiej odmiany betonu komórkowego. Charakteryzuje się on łatwością montażu, uzyskaniem korzystnego mikroklimatu pomieszczeń, poprawą bezpieczeństwa przeciwpożarowego, a także możliwością wykończenia powierzchni ścian na wiele sposobów. W referacie przedstawiono technologię zastosowania ww. systemu na przykładzie obiektu XIX-wiecznej byłej fabryki guzików zlokalizowanej w Poznaniu.
In the case of buildings with historic character, under the care of conservation, improving the thermal insulation of the building envelope it is only possible through their insulation from the inside. Thermal insulation of external walls of historic buildings willingly system is used MULTIPOR Xella uses mineral insulation boards made of very lightweight cellular concrete variety. It is characterized by ease of installation, to obtain a favorable microclimate of the rooms, the improvement of fire safety, as well as the possibility of finishing the surface of the wall in many ways. The paper presents the technology of application of the said system on the example of the object nineteenth-century former button factory located in Poznan.
Źródło:
Modern Engineering; 2016, 1; 73-81
2450-5501
Pojawia się w:
Modern Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurements of physicochemical and electrical properties of insulating liquids
Autorzy:
Zdanowski, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/376406.pdf
Data publikacji:
2019
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
dielectric liquids
transformer insulation
electrical properties
streaming electrification
Opis:
This paper provides a comparative analysis of key physicochemical and electrostatic parameters of Trafo En oil and Midel 7131® synthetic ester, changing in temperature and accelerated thermal ageing. The parameters tested included the density, kinematic viscosity, conductivity and relative electric permittivity. In addition to that, Electrostatic Charging Tendency (ECT) tests of those fluids were performed in a flow system using cellulose and aramid paper pipes. The effect of liquid flow velocity combined with temperature variations and accelerated ageing time on the streaming electrification current generated was determined. The relationship between the fluid electrification degree and measuring pipe material was also investigated.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2019, 98; 181-193
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biographical sketch of Jerzy Ignacy Skowroński
Autorzy:
Chrzan, Krystian Leonard
Powiązania:
https://bibliotekanauki.pl/articles/2008103.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Jerzy Ignacy Skowroński
electrical engineering
high voltage insulation
Opis:
The life of Jerzy Ignacy Skowronski, Professor of High Voltages, Dean of the Faculty of Mechanical and Electrical Engineering and the first Dean of the Electrical Faculty of the Wrocław University of Science and Technology, member of the real Polish Academy of Sciences and President of the Wrocław Scientific Society, founder of the Wrocław Scientific School of Electrical Materials, was described. Documents contained in the Archives of the Wrocław University of Science and Technology, works published by Jerzy I. Skowronski, previously published publications on his scientific merits written by his former Ph.D. students and information from his grandson Jan Paweł Skowronski were used. The author's intention was to show unknown facts from the life of the Professor and his works unknown until now.
Źródło:
Nauka; 2021, 1; 149-157
1231-8515
Pojawia się w:
Nauka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wybranych właściwości mieszanek na bazie kauczuku EPDM jako izolacji termicznej silnika rakietowego
The study of selected properties of compositions based on EPDM rubber as thermal insulation rocket motor
Autorzy:
Florczak, B.
Maciejewski, W.
Powiązania:
https://bibliotekanauki.pl/articles/92618.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
izolacja termiczna
mieszanina kauczukowa
thermal insulation
polymer blend
Opis:
Przedstawiono wyniki badań dotyczące doboru składu i określenia właściwości fizykomechanicznych i ognioodporności badanych mieszanin polimerowych stosowanych jako izolacja termiczna wiążąca paliwo stałe ze ścianką komory silnika.
The results of studies regarding the selection of the composition and determine the physical and mechanical properties and flame retardancy studied polymer blends used as insulation solid propellant binding with the wall of the chamber.
Źródło:
Materiały Wysokoenergetyczne; 2015, T. 7; 90-94
2083-0165
Pojawia się w:
Materiały Wysokoenergetyczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of air humidity and temperature on thermal conductivity of wood-based materials
Autorzy:
Trochonowicz, Maciej
Galas, Monika
Powiązania:
https://bibliotekanauki.pl/articles/390811.pdf
Data publikacji:
2018
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
wood-based materials
thermal conductivity coefficient
thermal insulation
Opis:
The aim of this paper is to approximate the issues related to the influence of air humidity and test temperature on the thermal conductivity coefficient λ of wood-based materials. During the laboratory tests, the λ coefficient was determined depending on the test temperature and air humidity, material density and sorption were also tested
Źródło:
Budownictwo i Architektura; 2018, 17, 4; 77-86
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Izolacja termiczna w zespołach napędowych rakiet po długoletnim składowaniu
Thermal isolation in rocket motor units after long term storing
Autorzy:
Studencki, M.
Powiązania:
https://bibliotekanauki.pl/articles/235543.pdf
Data publikacji:
2008
Wydawca:
Wojskowy Instytut Techniczny Uzbrojenia
Tematy:
izolacja termiczna
zespoły napędowe
thermal insulation
power plants
Opis:
W artykule omówiono celowość stosowania izolacji termicznej w zespołach napędowych rakiet na paliwo stałe. Na podstawie własnych badań, przedstawiono budowę i technologię wykonania warstwy termoizolacyjnej w zespołach napędowych rakiet przeciwlotniczych „OSA”. W formie dokumentacji fotograficznej, zaprezentowano jedną z metod oceny stanu technicznego tej warstwy z wykorzystaniem aparatury endoskopowej. Przedstawiono wyniki badań własnych mających na celu ustalenie przyczyn spalenia powłoki lakierniczej na zewnętrznej powierzchni zespołu napędowego rakiety „OSA”. Wskazano na konieczność chronienia powierzchni komory spalania przed mechanicznymi uderzeniami i większymi statycznymi naciskami z zewnątrz.
The expediency of using thermal isolation in rocket solid propellant motor units is presented in the paper. The design and technology for getting a thermo-isolating layer in motor units of antiaircraft missiles OSA is provided on the base of own research work. Technical evaluation of this layer was carried out by the endoscopic instrument and some results presented in the pictures included. Some results of own research work are presented to show the reasons for burning the paint coating on the external surface of OSA motor. It was pointed that there is an expediency to protect the surface of the burning chamber against mechanical hits and greater static stresses from outside.
Źródło:
Problemy Techniki Uzbrojenia; 2008, R. 37, z. 106; 75-88
1230-3801
Pojawia się w:
Problemy Techniki Uzbrojenia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of mechanical properties and coefficients of sound insulation of innovative silicone composite material
Autorzy:
Lakov, L.
Ivanova, Y.
Jivov, B.
Aleksandrova, M.
Barovsky, N.
Powiązania:
https://bibliotekanauki.pl/articles/391426.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
composites
sound insulation
soundproofing materials
heat insulating materials
Opis:
A new non-combustible, non-flammable, waterproof, long-lasting, heat-insulating composite material was made of glass foam granules (derived from glass waste) and a hydraulic inorganic binder in the form of a white Portland cement solution (CEM I 52.5 N), zeolite, airborne agent and water. The resulting composite is resistant to climatic temperature fluctuations, characterized by a coefficient of thermal conductivity of λ = 0.047 W/mK and is potentially applicable for the production of sound and heat insulating panels for non-bearing partition walls and external insulation of buildings. The technology for obtaining the product is in line with the current tendencies for the development of ecological productions through the utilization of waste materials and provides the opportunity to produce various standard monolith products suitable for direct use or further processing. Experimental studies of the acoustic and mechanical performance of standard experimental samples made from the developed composite material were carried out. The average sound insulation value is 30 dB. An average tensile strength of 0.036 MPa and an average compressive strength of 0.55 MPa were found.
Źródło:
Prace Instytutu Odlewnictwa; 2017, 57, 4; 245-251
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary rezystancji izolacji silników elektrycznych
Measurements of insulation resistance of electric motors
Autorzy:
Olesz, Marek
Kostro, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/267037.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
rezystancja izolacji
diagnostyka
eksploatacja
insulation resistance
diagnostics
exploitation
Opis:
W artykule podano zasady wykonywania pomiarów rezystancji izolacji maszyn elektrycznych. Przedstawiono dostępne w literaturze temperaturowe współczynniki korekcyjne konieczne do przeliczania zmierzonych wartości rezystancji na wartość występującą w temperaturze odniesienia. Obserwowane różnice współczynników temperaturowych wynikają z rodzaju zastosowanego materiału izolacji, konstrukcji silnika oraz technologii impregnowania uzwojeń.
The paper presents principles for insulation resistance measurements of electric motors. The temperature correction coefficients available in the literature to converting the measured resistance value into a value occurring at the reference temperature were analyzed. Occurred differences of temperature coefficients results from the insulation type, construction of the motor and winding impregnation technology.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 64; 29-32
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation model and state analysis of ship transmission line
Autorzy:
Hu, Y.
Xu, M.
Li, Y.
Powiązania:
https://bibliotekanauki.pl/articles/259613.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
ship power
transmission line
simulation model
insulation deterioration
Opis:
In order to discuss the simulation model of the ship transmission line and the state of the transmission line, an early fault model is built according to the evolution principle of the short circuit fault of the transmission line and combining with the fault characteristics of the early fault. A small distributed ship transmission line system is built in MATLAB/ Simulink. Then, combined with the constructed fault module, the original short circuit module, and the load module, the various states (normal state, early fault state, severe early fault state, short circuit state) of the ship transmission line are stimulated, and the features of voltage signal in each state is analysed. It is concluded that, due to the normal operation of the ship transmission line system, the variation characteristics of the flow signal and voltage signal caused by the sudden load mutation, that is, the sudden load and the sudden increase load, are very similar to the changes caused by the early fault. Therefore, in order to find a more accurate early fault detection method, the state is divided into normal state, sudden load state, sudden increase and sudden decrease load state.
Źródło:
Polish Maritime Research; 2018, S 3; 36-42
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ograniczenia obciążalności transformatorów o zawilgoconej izolacji
Loading limitations of power transformers with moistened insulation
Autorzy:
Mościcka-Grzesiak, H.
Morańda, H.
Gielniak, J.
Graczkowski, A.
Przybyłek, P.
Walczak, K.
Powiązania:
https://bibliotekanauki.pl/articles/155773.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
zawilgocona izolacja
eksploatacja transformatorów
moistened insulation
transformer exploitation
Opis:
W artykule przedstawiono warunki wystąpienia "bubble effect'u" z uwzględnieniem rozkładu zawilgocenia izolacji. Zasady obciążania i przeciążania transformatorów o zawilgoconej izolacji powiązano z dopuszczalną temperaturą "Hot Spot'u". Wnioski sformułowano w oparciu o wyniki badania zawilgocenia 46 polskich transformatorów sieciowych. Zbadanym transformatorom przyporządkowano następujące dopuszczalne typy obciążenia: 22% jednostek - możliwa normalna praca typu A oraz przeciążenia awaryjne typu B i C, 36% jednostek - możliwa normalna praca typu A oraz przeciążenie awaryjne typu B, 33% jednostek - możliwa tylko normalna praca typu A, 9% jednostek - niemożliwa normalna praca typu A. Z przeprowadzonych badań wynika, że tylko 22% jednostek może być obciążanych i przeciążanych zgodnie z Instrukcją Eksploatacji Transformatorów, a 78% transformatorów sieciowych wymaga ograniczenia obciążenia.
The paper presents the conditions for appearance of the bubble effect in grid transformers in the case of different moisture distributions in insulation. The rules for loading and overloading transformers in normal and emergency state are given in the Instruction of Transformer Exploitation (Table 1). The moistening of transformer insulation and its distribution have been connected with the maximum value of Hot Spot temperature. Table 2 shows the critical values of moisture leading to the bubble effect at the assumed Hot Spot temperature. Combination of high moisture and insulation temperature results in the possibility of the bubble effect appearance. For example, the same chance of this phenomenon occurrence is for the following combinations of the moisture and temperature: 1.5% - 145 oC, 2% - 140 o C, 3% - 124 oC [1, 7]. The inhomogeneity of moisture in transformers is influenced mainly by two factors: temperature distribution, the precipitation of water dissolved in oil in the case of significant reduction of the oil temperature - mainly when the transformer is turned off. The inhomogeneity moisture insulation factor, as the ratio of the local moisture value to the average value has been defined. For calculations there has been assumed a moderate value of the inhomogeneity moisture insulation factor equal to 1.2 (in transformers with the natural circulation of the oil it can obtain the value of 1.4). The investigated transformers can operate under the following limit load: 22% of them - normal work of type A and emergency overloading of type B and C, 36% - normal work of type A and emergency overloading of type B, 33% - normal work of type A only, 9% - even the normal work of type A is impossible. Only 22% of grid transformers can be loaded and overloaded according to the Instruction of Transformer Exploitation without the risk of the bubble effect appearance, and 78% of operating units requires reduction of load. The conclusions have been formulated on the basis of the investigation results of 46 Polish grid transformers (about 1/4 of the total population).
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 1, 1; 47-49
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of a Phase Resolved Partial Discharge Pattern Analysis for Acoustic Emission Method in High Voltage Insulation Systems Diagnostics
Autorzy:
Kunicki, M.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/177912.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission
partial discharge
transformer diagnostics
insulation system
Opis:
An alternative method for analysis of acoustic emission (AE) signals generated by partial discharges (PD), based on a correlation between voltage phase run and AE pulses, so called phase resolved PD pattern (PRPD), is presented in the paper. PRPD pattern is a well-known analysis tool commonly used in such PD diagnostic methods as conventional electrical and UHF ones. Moreover, it yields various signal analysis abilities and allows a direct correlation indication between measurement results achieved using different methods. An original PRPD measurement methodology applied for AE method as well as some exemplary measurement results and further data analysis capabilities are presented in the paper. Also a comparative analysis of PRPD patterns achieved using various measurement methods and different PD source configurations have been investigated. All presented experiments were done under laboratory conditions using PD model sources immersed in the insulation oil. The main purpose of the presented research is to indicate an all-embracing analytical tool that yields an ability to direct comparison (qualitative as well as quantitative) of the AE measurement results with other commonly applied PD measurement methods. The presented results give a solid fundamental for further research work concerning a direct correlation method for AE and other described in the paper diagnostic techniques, mainly in order to continue PD phenomena analysis and assessment in real life high voltage apparatus insulation systems under normal onsite operation conditions.
Źródło:
Archives of Acoustics; 2018, 43, 2; 235-243
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selection Criteria of Thermo-Insulating Materials to Insulate Wooden Building Facilities
Kryteria wyboru materiałów termoizolacyjnych do izolacji obiektów z drewna
Autorzy:
Misztal, Barbara
Mielińska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2034267.pdf
Data publikacji:
2021
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
insulation
wood
wooden buildings
budynki drewniane
drewno
izolacja
Opis:
The article presents the structure of wood as a fibrous composite made up of cells susceptible to moisture absorption. Attention was paid to the impact of insulation materials on the durability of wood. The flow of moisture in materials such as wood and glass wool representing a group of porous and non-absorbing materials is shown. Microscopic pictures of pine and oak wood, wood fibre mats and glass wool are shown. The full construction of fibers of glass wool and other e. g. mineral wool, makes them extremely non-beneficial for warming partitions in buildings involving wood. Materials with a stable heat conductivity in terms of natural humidity changes in construction works were recommended.
W artykule przedstawiono badania dotyczące struktury drewna jako kompozytu włóknistego zbudowanego z komórek podatnych na wchłanianie wilgoci. Zbadano wpływ materiałów izolacyjnych na trwałość drewna. Pokazano przepływ wilgoci w materiałach takich jak wełna drzewna i szklana reprezentujących grupę materiałów o włóknach porowatych i pełnych, nie nasiąkliwych. Przedstawiono zdjęcia mikroskopowe drewna sosnowego i dębowego, maty z włókien drzewnych i wełny szklanej. Pełna budowa włókien wełny szklanej i innych np. wełny mineralnej, powoduje, że są one wyjątkowo niekorzystne do ocieplania przegród w budynkach z udziałem drewna. Zalecono materiały o współczynniku przewodzenia ciepła stabilnym w zakresie naturalnych zmian wilgotności w obiektach budowlanych.
Źródło:
Przestrzeń i Forma; 2021, 46; 87-100
1895-3247
2391-7725
Pojawia się w:
Przestrzeń i Forma
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Occupational risk resulting from exposure to mineral wool when installing insulation in buildings
Autorzy:
Kupczewska-Dobecka, Małgorzata
Konieczko, Katarzyna
Czerczak, Sławomir
Powiązania:
https://bibliotekanauki.pl/articles/2116490.pdf
Data publikacji:
2020-10-20
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
mineral wool
insulation
fibers
health effects
toxicity
labeling
Opis:
Mineral wool is widely used for thermal and sound insulation. The subject of the study is to identify hazards for employees resulting from exposure to mineral wool, when it is used to insulate buildings, and to assess the risk arising from this exposure. When installing mineral wool insulation, respirable mineral fibers, dust, and volatile organic compounds may pose a hazard at workplaces. Based on the results of concentration measurements, it was assessed that the probability of adverse health effects related to the work of insulation installers, resulting from exposure to mineral wool fibers, is low, but for dust associated with exposure, an average health risk was estimated. An additional threat may be the sensitizing effect of substances used as binders and additives improving the utility properties of mineral wool, for example, phenol formaldehyde resins. The paper also contains some information on the labeling of mineral wool; this is very important because the label allows downstream users to recognize mineral wools, the composition and properties of which cause that they are not classified as carcinogens.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2020, 33, 6; 757-769
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sound Insulation of Dwellings Façades : the Case of Santiago de Chile
Autorzy:
Meza, Leonardo
Delannoy, Jaime
Marzzano, Antonio
Fuentes, Mauricio
Powiązania:
https://bibliotekanauki.pl/articles/176347.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
sound reduction index
construction quality
acoustic insulation
façade
Opis:
The increment in the number of automobiles and the densification of the city has increased noise pollution rates. In addition, the lack of regulation in Chile regarding the acoustic insulation of façades is a problem of a growing concern. The main objective of the present study was to obtain a model of the Sound Insulation of housing, façades, stratified in Santiago, Chile, based on constructive variables. It is expected to serve as a basis for one future regulation for acoustic façades of houses. In the present study, tests based on the international ISO 140-5 standard were carried out in situ. An estimation model of the Standardized Level Difference Dls;2m;nT;w + C, was obtained based on the opening/façade proportion, and the type of glass used for the windows.
Źródło:
Archives of Acoustics; 2019, 44, 1; 99-104
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on Sound Transmission across a Floating Floor in a Residential Building by Using SEA
Autorzy:
Huang, Xianfeng
Lu, Yimin
Qu, Chen
Zhu, Chenhui
Powiązania:
https://bibliotekanauki.pl/articles/1953500.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
sound transmission
floating floor
impact noise
sound insulation
Opis:
For the purpose of reducing the impact noise transmission across floating floors in residential buildings, two main sound transmission paths in the floating floor structure are considered: the stud path and the cavity path. The sound transmission of each path is analysed separately: the sound transmission through the cavity and the stud are predicted by statistical energy analysis (SEA). Then, the sound insulation prediction model of the floating floor is established. There is reasonable agreement between the theoretical prediction and measurement, and the results show that a resilient layer with low stiffness can attenuate the sound bridge effect, resulting in higher impact noise insulation. Then, the influences of the floor covering, the resilient layer and the floor plate on the impact sound insulation are investigated to achieve the optimised structure of the floating floor based on the sound insulation.
Źródło:
Archives of Acoustics; 2021, 46, 1; 183-194
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improvement of Sound Insulation Through Double-Panel Structure by Using Hybrid Local Resonator Array
Autorzy:
Ri, Kyong-Su
Kim, Myong-Jin
Son-U, Se-Hyon
Powiązania:
https://bibliotekanauki.pl/articles/31339917.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
sound insulation
local resonance
insertion loss
sonic crystal
Opis:
In this paper, we present one approach to improve the soundproofing performance of the double-panel structure (DPS) in the entire audible frequencies, in which two kinds of local resonances, the breathing-type resonance and the Helmholtz resonance, are combined. The thin ring resonator row and slit-type resonator (Helmholtz resonator) row are inserted between two panels of DPS together. Overlapping of the band gaps due to the individual resonances gives a wide and high band gap of sound transmission in the low frequency range. At the same time, the Bragg-type band gap is created by the structural periodicity of the scatterers in the high audible frequency range. In addition, the number of scatterer rows and the filling factor are investigated with regard to the sound insulation of DPS with sonic crystals (SCs). Consequently, the hybrid SC has the potential of increasing the soundproofing performance of DPS in the audible frequency range above 1 kHz by about 15 dB on average compared to DPS filled only with glass wool between two panels, while decreasing the total thickness and mass compared to the counterparts with the other type of local resonant sonic crystal.
Źródło:
Archives of Acoustics; 2023, 48, 1; 63-70
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność ocieplenia czyli trwałość i estetyka elewacji
Autorzy:
Śliwiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/128811.pdf
Data publikacji:
2017
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
ocieplenie
efektywność
oszczędność energii
trwałość
estetyka
bezawaryjność
system ocieplania
thermal insulation
efficiency
energy savings
durability
esthetics
reliability
thermal insulation system
Źródło:
Builder; 2017, 21, 6; 78-80
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ cyklicznego zamrażania i rozmrażania wilgoci zawartej w materiale izolacyjnym na straty ciepła ściany nadwozia chłodniczego
Examining the degradation process of the heat/cold protecting insulation applied for construction of cooling bodies under the influence of water
Autorzy:
Rochatka, T.
Powiązania:
https://bibliotekanauki.pl/articles/313556.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
nadwozie chłodnicze
materiał izolacyjny
destrukcja materiału izolacyjnego
własności izolacyjne
refrigeration body
insulating material
destruction of materials
destruction of insulation
insulation properties
Opis:
Współczesny transport żywności łatwopsującej się oraz innych wrażliwych na zmiany temperatur ładunków jest realizowany w oparciu o specjalistyczne nadwozia izotermiczne i chłodnicze. Nadwozia te z punktu widzenia wymagań umowy ATP podlegają certyfikacji na różne klasy nadwozi w zależności od właściwości izolacyjnych. Mostki ciepła konstrukcyjne - wzmocnienia wprowadzone w strukturę płyt warstwowych na etapie produkcji i technologiczne - błędy wykonawcze, są stabilne w czasie eksploatacji. Właściwości izolacyjne nadwozi eksploatowanych pogarszają się skutkiem czego więcej ciepła przenika do nadwozia co z kolei powoduje wzrost zużycia paliwa do napędu agregatu chłodniczego i wzrost zagrożenia zdrowia i życia ludzi - przyszłych konsumentów przewożonych towarów. Przyczyną pogorszania się staniu izolacji nadwozi jest wnikanie wody do materiału ciepło/zimnochronnego oraz dalsza destrukcja własności izolacyjnych przez wilgoć, która w materiale izolacyjnym podlega cyklicznym procesom zamrażania i rozmrażania w zależności od temperatury przewożonych towarów. W artykule przedstawiono wyniki badań destrukcji materiału izolacyjnego pod wpływem cyklicznego zamrażania i rozmrażania wody, wprowadzonej do materiału izolacyjnego. Skutki eksploatacji zawilgoconego materiału izolacyjnego badano w zależności od ilości cykli zamrażania i rozmrażania uzyskując dużo większe pogorszenie własności izolacyjnych niż samo wprowadzenie wody do suchego materiału izolacyjnego.
Contemporary transport of perishable food and other cargoes sensitive for temperature changes is carried out basing on specialist isothermal and cooling bodies. The reason of the deterioration of the body insulation condition is the penetration of water into the heat/cold protecting material and the further destruction of the insulation properties by moisture which in the insulating material is subject to cyclic freezing and defrosting processes depending on the temperature of the transported goods. The paper presents the tests results on the destruction of the insulating material under the influence of cyclic freezing and defrosting of water introduced into the insulating material. The effects of servicing the damp insulating material were examined depending on the quantity of cycles of freezing and defrosting getting much worse deterioration of insulating properties than in case of entering water into the dry insulating material.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 12; 1271-1274, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preparation and Performance Optimization of Organosilicon Slag Exothermic Insulating Riser
Autorzy:
Lu, Jijun
Qian, Jiangbing
Yang, Lei
Wang, Huafang
Powiązania:
https://bibliotekanauki.pl/articles/27314121.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
organosilicon slag
exothermic insulation
optimization
żużel krzemoorganiczny
izolacje
optymalizacja
Opis:
The exothermic insulating riser played an important role in the solidification process of metal liquid for the improvement of casting quality. This paper focused on the use of organosilicon slag to replace part of the aluminum powder as an exothermic agent for the riser, to reduce production costs and turn waste into treasure. The experiments firstly studied the effect of organosilicon slag content on the combustion temperature and holding time and determined the components of the riser exothermic agent and organosilicon slag. On this basis, the effects of the content of Na3AlF6 flux and alkali phenolic resin binder on the combustion heating time and strength properties of the riser were studied. And the ratio of mixed oxidants was determined by single-factor orthogonal experiments to optimize the addition of three oxidants, Fe3O4, MnO2, and KNO3. Finally, the performance of the riser prepared after optimization was compared with that of the riser prepared with general aluminum powder. The results showed that with the mixture of 21% organosilicon slag and 14% aluminum powder as the exothermic agent, the highest combustion temperature of the prepared exothermic insulating riser was 1451℃ and the holding time was 193 s; the optimal content of Na3AlF6 flux was 4%, and the best addition alkali phenolic resin binder was 12%; the optimized mixing ratio of three oxidants was 12% for Fe3O4, 6% for MnO2, and 6% for KNO3. Under the optimized ratio, the maximum combustion temperature of the homemade riser was 52℃ and the heat preservation time was 14% longer compared with the conventional exothermic insulating riser with 25-35% aluminum powder.
Źródło:
Archives of Foundry Engineering; 2023, 23, 1; 75--82
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of Clothing Size on Thermal Insulation – A Pilot Study
Autorzy:
Młynarczyk, Magdalena
Orysiak, Joanna
Jankowski, Jarosław
Prus, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/24200936.pdf
Data publikacji:
2023
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
thermal insulation
air gap
air volume
3D scanning
Opis:
Thermal insulation may be influenced by the size of clothing and thus the volume of air gaps. The aim of this study was to determine the relationship between the size of outer wear clothing, and thus the indirect fit (the volume and size of air gaps), and thermal insulation in static and dynamic conditions. A set of underwear and two types of outerwear for workers of the energy sector and the chemical industry were selected for the study. Results showed that the value of thermal insulation (regardless of the type of outerwear) first increased with increasing clothing size.
Źródło:
Fibres & Textiles in Eastern Europe; 2023, 31, 1; 1--8
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The role of microparticles in initiating the electric breakdown in high–voltage vacuum insulation systems
Autorzy:
Opydo, W.
Opydo, D.
Bieliński, W.
Powiązania:
https://bibliotekanauki.pl/articles/97674.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
high–voltage vacuum insulation systems
metallic microparticles
electric breakdown
Opis:
The paper presents the hypotheses of initiating mechanisms of the electric breakdown in vacuum insulation systems caused by small material granules, i.e. the microparticles. The microparticles detached from the parent electrode have an electric charge and move in the inter–electrode area due to the electric field. The role of a microparticle in initiating the breakdown in a vacuum insulation system depends to a considerable extent on the microparticle energy at the moment of its impact against the opposite electrode, i.e. on its velocity at the impact time. The paper presents calculation of the microparticle velocity values at the moment of the impact against the opposite electrode under the conditions existing in practice in the vacuum insulation systems. It was assumed for purposes of the calculation that the microparticles are spherical and made of copper, aluminum or iron, and are subjected to constant electric field. Minimum values of the microparticle velocity necessary to cause plastic deformation of the electrode surface in result of the impact are determined. (The calculations have been carried out with the computer program developed in C# language on the Visual Studio 2013 environment.)
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 177-186
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Low voltage winding insulation systems under the influence of high du/dt slew rate inverter voltage
Autorzy:
Pauli, Florian
Ruf, Andreas
Hameyer, Kay
Powiązania:
https://bibliotekanauki.pl/articles/140993.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
life time
partial discharge
SiC semiconductors
winding insulation system
Opis:
Variable speed and low voltage electrical drives are commonly operated by frequency converters. According to recent developments, there is a trend in the area of semi-conductors, that switching frequency and voltage slew rate will increase significantly. The aim of these semiconductors is to reduce the switching losses and to increase the switching frequency, which enables to reduce the size of passive components in the powerelectric circuit. This results in less material effort and lower cost, for the power electronic component. However, electric motors operated by high slew rate inverters show problems in the winding insulation, which have to be analyzed. Such problems are well known for high voltage machines. Due to the increasing slew rate, this problematic occurs in low voltage machines nowadays as well. Here, the influence of fast switching semiconductors on the winding insulation system is studied, using accelerated ageing tests with fast switching high-voltage generators.
Źródło:
Archives of Electrical Engineering; 2020, 69, 1; 187-202
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examination of the Electric Field Intensity Distribution Between Wet Surfaces During Cable Aging Process
Autorzy:
Gunes, I.
Powiązania:
https://bibliotekanauki.pl/articles/1032064.pdf
Data publikacji:
2017-03
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
Cable insulation
electric field
dry band arcing
aging test
Opis:
In this study, electric field effect was investigated by dry band arcing test method. ADSS (all-dielectric self-supporting) cables are usually placed on power grids. These cables are affected by temperature and are exposed to many environmental effects such as wind and UV rays. In this study, the effect of water flow over ADSS cable on electric surface erosion on dry surfaces was investigated by electric arcing method, according to IEEE 1222 standard and the electric field intensity at the surface and the electric potential distribution were analyzed using the finite element method.
Źródło:
Acta Physica Polonica A; 2017, 131, 3; 548-550
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transient resonance of machines and devices in general motion
Rezonans przejściowy w maszynach i urządzeniach w ruchu ogólnym
Autorzy:
Michalczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/280512.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
transient resonance
vibratory machines
vibration insulation
limited power systems
Opis:
The new, more accurate and general possibility of assessments of maximum amplitudes of vibratory machines and vibroinsulated systems during their passage through the resonance was considered in the paper. The energy balance of the system was applied and the analytical solution for typical systems of several degrees of freedom during free coasting was given. The formulated method can be applied to systems of multiple degrees of freedom including continuous systems.
W pracy wskazano na nową , dokładniejszą,możliwość oszacowania amplitud maksymalnych maszyn o ruchu drgającym i układów wibroizolowanych, podczas przejścia przez rezonans. Wykorzystano w tym celu bilans energetyczny układu i podano rozwiązanie analityczne dla typowych układów o wielu stopniach swobody podczas wybiegu swobodnego. Sformułowana metoda może mieć zastosowanie dla dowolnych układów wielomasowych, w tym, układów ciągłych.
Źródło:
Journal of Theoretical and Applied Mechanics; 2012, 50, 2; 577-587
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ograniczenie wpływu oddziaływań dynamicznych podłoża na precyzję pracy mikrorobota
Limitation of dynamic influence of substratum on precision of micromanipulator work
Autorzy:
Targosz, J.
Powiązania:
https://bibliotekanauki.pl/articles/252109.pdf
Data publikacji:
2015
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
mikrorobot
medycyna
drgania
wibroizolacja
micromanipulator
medicine
vibrations
vibration insulation
Opis:
Problemem podjętym w pracy jest ograniczenie wpływu oddziaływań dynamicznych podłoża na dokładność pracy mikrorobota, mającego służyć celom medycznym. Drgania fundamentu na którym posadowiony jest mikrorobot mogą w sposób znaczny wpłynąć na dokładność pozycjonowania elementu wykonawczego. Jedną z metod ograniczenia tego niekorzystnego wpływu jest pasywna wibroizolacja mikrorobota. W pracy przedstawiono model matematyczny układu wibroizolacji, dobór jej parametrów oraz rezultaty wstępnych badań doświadczalnych.
The problem taken in the work is the limitation of the influence the substratum dynamic on the accuracy of the micromanipulator used for medical purposes. The vibrations of the foundation on which the micromanipulator is built on can have a significant effect on the positioning accuracy of the micromanipulator actuator. One of the solutions to reduce this negative impact is application of passive vibration isolation system of Micromanipulator. The paper presents a mathematical model of vibration isolation system, selection of its parameters and preliminary results of experimental studies.
Źródło:
TTS Technika Transportu Szynowego; 2015, 12; 1535-1538, CD
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ jakości oleju na spektrum napięcia powrotnego w układach modelowych papier-olej
Influence of oil quality on recovery voltage spectrum of oil-paper insulation models
Autorzy:
Szymański, J.
Graczkowski, A.
Walczak, K.
Powiązania:
https://bibliotekanauki.pl/articles/153189.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
recovery voltage spectrum
oil resistivity
equivalent circuit of insulation
Opis:
Zbyt uproszczona interpretacja spektrum napięcia powrotnego może prowadzić do błędnej oceny zawilgocenia układu izolacyjnego papier-olej. Najwięcej kontrowersji wzbudza nieuwzględnienie w interpretacji wpływu jakości oleju na parametry spektrum polaryzacyjnego (system pomiarowy Tettex 5462 plus firmowy program do interpretacji wyników). W badaniach wykorzystano symulację komputerową oraz układy modelowe izolacji papierowo-olejowej do określenia wpływu rezystywności oleju na spektrum napięcia powrotnego. Wyniki przedstawiono w niniejszym artykule.
Very simple interpretation of recovery voltage spectrum can be the reason for incorrect evaluation of moisture content in oil-paper insulation system. The software for the recovery voltage spectrum analysis offered by Tettex does not take into consideration such important parameter like oil resistivity. In research authors used computer simulation and models of oil-paper insulation system in order to determine influence of oil quality on recovery voltage spectrum. The results of the investigations were presented in this paper.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 10, 10; 709-712
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Variability of the Acoustic Emission Signals Generated by Partial Discharges in Mineral Oil
Autorzy:
Kunicki, Michał
Powiązania:
https://bibliotekanauki.pl/articles/177772.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
acoustic emission
partial discharge
insulation system
measurements
signal processing
Opis:
The main purpose of the presented research is to investigate the partial discharge (PD) phenomenon variability under long-term AC voltage with particular consideration of the selected physical quantities changes while measured and registered by the acoustic emission method (AE). During the research a PD model source generating surface discharges is immersed in the brand new insulation mineral oil. Acoustic signals generated by the continuously occurred PDs within 168 hours are registered. Several qualitative and quantitative indicators are assigned to describe the PD variability in time. Furthermore, some longterm characteristics of the applied PD model source in mineral oil, are also presented according to acoustic signals emitted by the PD. Finally, various statistical tools are applied for the results analysis and presentation. Despite there are numerous contemporary research papers dealing with long-term PD analysis, such complementary and multiparametric approach has not been presented so far, regarding the presented research. According to the presented research from among all assigned indicators there are discriminated descriptors that could depend on PD long-term duration. On the grounds of the regression models analysis there are discovered trends that potentially allow to apply the results for modeling of the PD variability in time using the acoustic emission method. Subsequently such an approach may potentially support the development and extend the abilities of the diagnostic tools and maintenance policy in electrical power industry.
Źródło:
Archives of Acoustics; 2019, 44, 2; 339-348
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Iniekcyjna technologia tworzenia horyzontalnych barier izolacyjnych: z laboratorium do warstwy wodonośnej
Trenchless technology of forming horizontal insulation barriers: from laboratory to aquifer
Autorzy:
Falkowicz, S.
Cicha-Szot, R.
Powiązania:
https://bibliotekanauki.pl/articles/170256.pdf
Data publikacji:
2018
Wydawca:
Poltegor-Instytut Instytut Górnictwa Odkrywkowego
Tematy:
warstwy wodonośne
bariera izolacyjna
krzemiany
aquifer
insulation barriers
silicates
Opis:
W artykule omówiono wyniki prac laboratoryjnych, których celem było określenie wpływu wybranych parametrów procesu tłoczenia ditlenku węgla do modelu porowatej warstwy wodonośnej na skalę i dynamikę jego wypływu z tejże warstwy. Określono objętość warstwy, przez którą wypływał ditlenek węgla oraz stopień nasycenia (saturacji) warstwy wodonośnej gazem. Punktowe zatłaczanie ditlenku węgla do warstwy wodonośnej jest jednym z pierwszych etapów wykonywania poziomych barier izolacyjnych, zgodnie z założeniami Technologii Horyzontalnych Barier Krzemianowych (THBK). Celem technologii THBK jest likwidacja pionowego przepływu płynów w ośrodku geologicznym, co daje szerokie pole zastosowań w ochronie wód podziemnych i górnictwie. W pracy wykonano symulację procesu oraz zoptymalizowano parametry zatłaczania cieczy zabiegowej. Podjęto także próbę przeniesienia uzyskanych w laboratorium wyników do warunków płytkich warstw wodonośnych
The article discusses the results of laboratory work, the objective of which was to determine the relevant parameters of technological process of aquifer saturation by carbon dioxide during forming horizontal insulating barriers, in accordance with the Technology of forming Horizontal Silicate Barriers (THBK). The main objective of the THBK technology is vertical control of fluid flow in porous media, what gives a wide field of applications in groundwater protection and mining. In this work simulation of saturation process and optimization of injection parameters were performed. Moreover, an attempt to transfer obtained laboratory results to shallow aquifers conditions was conducted.
Źródło:
Górnictwo Odkrywkowe; 2018, 59, 2; 85-91
0043-2075
Pojawia się w:
Górnictwo Odkrywkowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Variable Sound Insulation Structure with MFC Elements
Autorzy:
Górski, P.
Kozupa, M.
Powiązania:
https://bibliotekanauki.pl/articles/177289.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
sound insulation
active noise reduction
macro fiber composite (MFC)
Opis:
Additional sound sources are used as actuators in the vast majority of active noise reduction systems. One of the possible opportunities to extend the field of applications of active noise reduction systems is using active structures of variable sound insulation. The paper presents an analysis of ways of reducing noise with a structure of variable sound insulation consisting of a metal plate, active elements (Macro Fiber Composite), and a control system. The paper presents results of acoustic radiation simulations and measurements of sound intensity generated by the structure under the influence of stimulation by an acoustic wave. Simulations of mechanical vibrations and acoustic radiation for the plate were performed with the finite element method and ANSYS software. Simulation results made it possible to select locations for gluing the active elements and sensors. Analyses of the sound pressure level in the space to which the plate is radiating made it possible to determine dominant frequencies in the characteristics and, as a result, indicate vibration modes that can be reduced. Sound intensity measurements were performed with a three-way probe of USP mini Microflown. Results of simulations and measurements show that it is possible to achieve an improvement of the insulating power of a metal plate by approx. 10 dB.
Źródło:
Archives of Acoustics; 2012, 37, 1; 115-120
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examining the degradation process of the heat/cold protecting insulation applied for construction of cooling bodies under the influence of water
Autorzy:
Rochatka, T.
Powiązania:
https://bibliotekanauki.pl/articles/114327.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
degradation of insulation material
heat flux
thermovision
isothermal body
Opis:
Contemporary transport of perishable food and other cargoes sensitive for temperature changes is carried out basing on specialist isothermal and cooling bodies. The reason of the deterioration of the body insulation condition is the penetration of water into the heat/cold protecting material and the further destruction of the insulation properties by moisture which in the insulating material is subject to cyclic freezing and defrosting processes depending on the temperature of the transported goods. The paper presents the test results on the destruction of the insulating material under the influence of cyclic freezing and defrosting of water introduced into the insulating material. The effects of servicing the damp insulating material were examined depending on the quantity of cycles of freezing and defrosting getting much worse deterioration of insulating properties than in case of entering water into the dry insulating material.
Źródło:
Measurement Automation Monitoring; 2017, 63, 3; 119-121
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modele matematyczne transmisji promieniowania przez komórkowe izolacje transparentne
Mathematical models of solar transmission through transparent insulation
Autorzy:
Grudzińska, M
Powiązania:
https://bibliotekanauki.pl/articles/362459.pdf
Data publikacji:
2011
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
izolacje transparentne
transmisja promieniowania słonecznego
transparent insulation
solar transmission
Opis:
W artykule porównano najczęściej stosowane modele transmisji promieniowania płyt komórkowych, wykorzystywanych jako izolacje transparentne. Przedstawiono także własny, zmodyfikowany sposób obliczeń który może służyć opracowywaniu algorytmów komputerowych modelujących własności płyt transparentnych.
The paper presents basic mathematical models of solar transmission through the transparent insulation. Comparison between models shows the importance of including the radiation scattering during the calculation procedures.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2011, T. 6, nr 4, 4; 21-26
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uproszczona metoda badań izolacyjności akustycznej w polu fal płaskich
Simplified procedure of sound insulation research in the field of plane waves
Autorzy:
Wątły, J.
Jabłoński, M.
Powiązania:
https://bibliotekanauki.pl/articles/362804.pdf
Data publikacji:
2007
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
akustyka
badania akustyczne
izolacyjność akustyczna materiałów
acoustic
sound insulation
Opis:
W referacie przedstawiono opis stanowiska pomiarowgo zaprojektowanego do badań izolacyjności akustycznej próbek w polu fal płaskich.
Description of measurement station designet for research of sample's sound insulation in the field of plane waves has been presented in this paper.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2007, T. 2; 297-300
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Variability of the predicted insulation index of clothing in the Norwegian Arctic for the period 1971-2000
Autorzy:
Araźny, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/2051892.pdf
Data publikacji:
2006
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Norwegian Arctic
bioclimate
predicted insulation of clothing
atmospheric circulation
Źródło:
Polish Polar Research; 2006, 27, 4; 341-357
0138-0338
2081-8262
Pojawia się w:
Polish Polar Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calculation of Clothing Insulation by Serial and Parallel Methods: Effects on Clothing Choice by IREQ and Thermal Responses in the Cold
Autorzy:
Kuklane, K.
Gao, C.
Holmer, I.
Giedraityte, L.
Brode, P.
Candas, V.
Hartog den, E.
Meinander, H.
Richards, M.
Havenith, G.
Powiązania:
https://bibliotekanauki.pl/articles/90632.pdf
Data publikacji:
2007
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
cold protective clothing
insulation
IREQ
serial
parallel
calculation method
Opis:
Cold protective clothing was studied in 2 European Union projects. The objectives were (a) to examine different insulation calculation methods as measured on a manikin (serial or parallel), for the prediction of cold stress (IREQ); (b) to consider the effects of cold protective clothing on metabolic rate; (c) to evaluate the movement and wind correction of clothing insulation values. Tests were carried out on 8 subjects. The results showed the possibility of incorporating the effect of increases in metabolic rate values due to thick cold protective clothing into the IREQ model. Using the higher thermal insulation value from the serial method in the IREQ prediction, would lead to unacceptable cooling of the users. Thus, only the parallel insulation calculation method in EN 342:2004 should be used. The wind and motion correction equation (No. 2) gave realistic values for total resultant insulation; dynamic testing according to EN 342:2004 may be omitted.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2007, 13, 2; 103-116
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of concentrated winding topologies considering transient voltages in the winding system of inverter-driven low-voltage machines
Autorzy:
Pauli, Florian
Driendl, Niklas
Mönninghoff, Sebastian
Hameyer, Kay
Powiązania:
https://bibliotekanauki.pl/articles/2172796.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
d/d
electrical machines
insulation system
inverters
transient voltages
Opis:
To reduce the losses of the power electronic inverter, the voltage slew rate (d u/d t) of the electric motors supplying voltage is increasing. As steep voltage slopes excite high frequencies in the megahertz range, transient phenomena in the winding of the electrical machine occur. To design the insulation system, the maximum electric potential difference between the conducting elements must be predicted. General design rules can lead to a significant overengineering of the interturn insulation, particularly when considering smaller stators with a known wire distribution. Therefore, two different winding topologies are studied comparing the voltage distribution in a round-wire winding and a winding with preformed coils.
Źródło:
Archives of Electrical Engineering; 2022, 71, 4; 865--880
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fabrication of Agar-Silica Aerogel Nanocomposite Films
Autorzy:
Lee, Min-Jin
Jung, Hyun-Ah
Lee, Kyong-Jin
Hwang, Haejin
Powiązania:
https://bibliotekanauki.pl/articles/356287.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermal insulation film
silica aerogel
agar
thermal conductivity
transmittance
Opis:
In this study, agar-based nanocomposite films containing ultra-porous silica aerogel particles were fabricated by gel casting using an aqueous agar/silica aerogel slurry. The silica aerogel particles did not show significant agglomeration and were homogeneously distributed in the agar matrix. Transmission electron microscopy observations demonstrated that the silica aerogel particles had a mesoporous microstructure and their pores were not incorporated into the agar polymer molecules. The thermal conductivities of the agar and agar/5wt.% silica aerogel nanocomposite films were 0.36 and 0.20 W·m-1·K-1, respectively. The transmittance of the agar films did not decrease upon the addition of silica aerogel particles into them. This can be attributed to the anti-reflection effect of silica aerogel particles.
Źródło:
Archives of Metallurgy and Materials; 2019, 64, 3; 851-855
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of conductive particle contaminationon the insulation system of rotating electrical machines with direct oil cooling
Autorzy:
Yang, Liguo
Pauli, Florian
Zhang, Shimin
Hambrecht, Fabian
Hameyer, Kay
Powiązania:
https://bibliotekanauki.pl/articles/2135735.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cooling
insulation system
particle contamination
partial discharge
surface resistance
Opis:
An integration of the electrical machine and the gearbox is attracting particular attention for the design of modern electric and hybrid drive trains, since it saves overall space and subsequently increases the power density. Another benefit of a high level of integration is that it enables a combined application of oils as both cooling fluid for the electrical machine and as lubrication fluid for the transmission system. In this way, the power density of the integrated drive train can be further increased. During the oil cycling, conductive contaminations may be introduced and subsequently have an influence on the function of the insulation system of the electrical machine. In the present work, the influences of the cooling oil and its conductive contaminations, conductive particles as well as their combination with humidity, on the electrical and dielectric properties of the insulation system are studied. The results show that by application of the cooling oil, the partial discharge inception voltage (PDIV) of the winding insulation increases significantly so that an electrical breakdown is prone to happen before a partial discharge (PD) occurs. With increasing particle contamination, the PDIV of the insulation system decreases significantly, while the capacitance increases. Besides, conductive particles and humidity decrease the surface resistance and surface breakdown voltage of the insulation papers significantly. The results indicate that the conductive particle contaminations can play an important role for the electrical degradation of the insulation system.
Źródło:
Archives of Electrical Engineering; 2022, 71, 3; 789--804
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy termomodernizacji budynków wybudowanych metodą przemysłową w systemie „Cegły Żerańskiej” na przykładzie projektu termomodernizacji budynku zlokalizowanego w Warszawie na osiedlu Nowa Praga
Difficulties related to the thermal modernization of buildings built with industrial system „Żerańska Brick” (Cegła Żerańska) exemplified by technical thermomodernization project for a building located in the housing estate Nowa Praga in Warsaw
Autorzy:
Machnikowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/111145.pdf
Data publikacji:
2014
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
docieplanie cegły żerańskiej
termomodernizacja budynków
thermal insulation
Żerańska Brick
Opis:
Niniejszy artykuł ma na celu przedstawienie problemów technicznych związanych z dociepleniem budynków wykonywanych specyficzną metodą przemysłową. Opisano w nim niuanse mogące wpływać na dobór metody kotwienia warstw izolacji oraz wynikające z tego ograniczenia. Opisane ograniczenia wynikają głównie z występowania różnych warstw na elewacji budynku oraz jego wysokości sumarycznej.
This article aims to present technical problems occurring while conducting the thermal insulation of buildings with a specific industrial method. There are described nuances that may affect the choice of method of anchoring insulation layers and restrictions resulting from it. The restrictions mentioned in the article are mainly due to the presence of different layers on the facade of a building and its total height.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2014, 1; 21-28
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of selected parameters on the electrical strength of a high-voltage vacuum insulation system
Autorzy:
Lech, Michał
Węgierek, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/27309926.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
electrical breakdown
electrical contacts
electrical strength
switchgear
vacuum insulation
Opis:
The article presents the results of laboratory measurements of breakdown voltages in a high-voltage vacuum insulating system for different pressures, contact gaps, type of electrode contacts and type of residual gas inside the discharge chamber. First of all, the electrical strength of the discharge chamber with a contact system terminated with contact pads made of W70Cu30 and Cu75Cr25 material was compared for selected values of contact gaps. It was found that below a pressure of = 3.0×10−1 Pa the electrical strength reaches an approximately constant value for each of the set contact gaps . Analytical relationships were determined to calculate this value for each of the contact pads used. Above a pressure of = 3.0 × 10−1 Pa, the measured values of breakdown voltages decrease sharply. The values of breakdown voltages in the discharge chamber with residual gases in the form of air, argon, neon and helium were also determined for selected values of contact gaps . Depending on the residual gases used, significant differences were noted in the values of pressure at which the loss of insulating properties in the discharge chamber occurred. These values were 3.3 × 10−1 Pa for argon, 4.1 × 10−1 Pa for air, 6.4 × 10−1 Pa for neon, and 2.55 × 100 Pa for helium, respectively.
Źródło:
Archives of Electrical Engineering; 2023, 72, 3; 597--611
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis on Acoustic Disturbance Signals Expected During Partial Discharge Measurements in Power Transformers
Autorzy:
Kunicki, Michał
Powiązania:
https://bibliotekanauki.pl/articles/1953519.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
acoustic emission
partial discharge
insulation system
measurements
power transformers
Opis:
This paper presents comparative analysis of various acoustic signals expected during partial discharge (PD) measurements in operating power transformer. Main purpose of the paper is to yield relevant and reliable method to distinguish between various acoustic emission (AE) signals emitted by PD and other sources, with particular consideration of real-life results rather than laboratory simulations. Therefore, selected examples of real-life AE signals registered in seven different power transformers, under normal operation conditions, within few years are showed and analyzed. Five scenarios are investigated, which represent five types of AE sources: PD generated by artificial sources, and next four real-life sources (including PD in working transformer, oil flow, oil pumps and core). Several different signal processing methods are applied and compared in order to identify the PD signals. As a result, an energy patterns analysis based on the wavelet decomposition is found as the most reliable tool for identification of PD signals. The presented results may significantly support the process of interpretation of the PD measurement results, and may be used by field engineers as well as other researchers involved in PD analysis using AE method. Finally, observed properties also provide a solid basis for establishing or improving complete classification method based on the artificial intelligence algorithms.
Źródło:
Archives of Acoustics; 2020, 45, 4; 733-746
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wpływu stopnia zawilgocenia oraz zestarzenia papieru na charakterystyki prądu depolaryzacji
The assessment of the influence of dampness and aging degrees of paper of depolarization current characteristics
Autorzy:
Wolny, S.
Kędzia, J.
Powiązania:
https://bibliotekanauki.pl/articles/153199.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
izolacja papierowo-olejowa
prąd depolaryzacji
zawilgocenie i zestarzenie izolacji
transformatory energetyczne
paper-oil insulation
depolarization current
dampness and aging insulation
power transformers
Opis:
Artykuł przedstawia aproksymacyjną metodę analizy charakterystyk czasowych prądu depolaryzacji, wykorzystywaną w diagnostyce stanu systemów izolacji papierowo-olejowej transformatorów energetycznych. Do badań wykorzystano laboratoryjny układ przystosowany do przeprowadzania diagnostyki zgodnej z zaleceniami metody PDC (Polarization and Depolarization Current). Eksperymenty przeprowadzono na próbkach izolacji wykonanych z elektrotechnicznego papieru transformatorowego impregnowanego świeżym mineralnym olejem izolacyjnym, zróżnicowanych zarówno pod kątem stopnia zawilgocenia, jak i zestarzenia (degradacji termicznej celulozy). Uzyskane wnioski pozwalają dokonać wstępnej selekcji parametrów równań aproksymujących, pod kątem ich przydatności w opisywanej diagnostyce transformatorów energetycznych.
The paper presents the approximation method of depolarization current time characteristics used in diagnostics of paper-oil insulation condition of power transformers. A laboratory system adapted for diagnostics in compliance with the recommendations of the polarization and depolarization current (PDC) method was used. The experiments were carried out on insulation samples made of electrotechnical transformer paper impregnated with fresh mineral insulation oil which varied in the degrees of dampness and aging (thermal degradation of cellulose). The conclusions drawn make an initial selection of approximation equations possible, taking into account their usefulness in diagnostics of power transformers.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 10, 10; 723-726
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dwupłytowa struktura aktywna do ograniczania transmisji hałasu przez obudowy i przegrody dźwiękoizolacyjne
Double-layered active structure for reducing noise transmission through sound insulating barriers
Autorzy:
Morzyński, L.
Krukowicz, T.
Powiązania:
https://bibliotekanauki.pl/articles/181117.pdf
Data publikacji:
2017
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
hałas
obudowa dźwiękoizolacyjna
akustyczno-strukturalna aktywna redukcja hałasu
mikrofon wirtualny
noise
sound insulation
sound insulation enclosure
active structural acoustic control
virtual microphone
Opis:
Obudowy dźwiękoizolacyjne są jednym i podstawowych środków technicznych, stosowanych powszechnie do ograniczania hałasu. Izolacyjność przegród pasywnych maleje jednak ze spadkiem częstotliwości dźwięku. Izolacyjność w zakresie niskich częstotliwości może być zwiększona poprzez zastosowanie aktywnych metod redukcji hałasu. W artykule przedstawiono budowę i zasadę działania dwupłytowej struktury aktywnej do ograniczania transmisji hałasu przez przegrody. Do sterowania przegrodą korzystano algorytm z ekstrapolacją sygnału błędu w oparciu o sygnały z przetworników drganiowych Przedstawiono wyniki badań struktury na stanowisku laboratoryjnym.
Sound insulating enclosures are a basic technical measure commonly used to reduce noise. Insulation of passive sound insulating barriers, however, decreases with a decrease in frequency. Insulation in the low frequency range can be increased by using active noise control methods. This article presents the structure and principle of operation of a double-layered active structure to limit the transmission of noise through barriers. An algorithm, which extrapolates the error microphone signal based on signals from the vibration transducers, is used for structure control. This article presents structure performance in laboratory conditions.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2017, 10; 24-28
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przegląd metod dociepleń ścian zewnętrznych wykonywanych od strony wewnętrznej budynku
The review of the external wall insulation methods from the inside of a building
Autorzy:
Rejman, Mariusz
Dziadosz, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/1848338.pdf
Data publikacji:
2021
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
ocieplanie od wewnątrz
ściana zewnętrzna
tynk termoizolacyjny
perlit
płyta silikatowo-wapienna
external wall
internal thermal insulation
thermal insulation plaster
perlite
silicate-limestone board
Opis:
W artykule opisano trzy najczęściej stosowane obecnie w Polsce metody dociepleń ścian zewnętrznych od strony wewnętrznej budynków. Dla każdej z metod scharakteryzowano innowacyjne materiały termoizolacyjne oraz sposoby ich produkcji, opisano sposoby wykonania/montażu dociepleń. W podsumowaniu wskazano zalety, a także wady poszczególnych metod, dokonano ich porównania i oceny, wskazano konsekwencje dociepleń ścian zewnętrznych od strony wewnętrznej budynku oraz podano zalecenia projektowe i wykonawcze.
The article describes three methods of thermal insulation of external walls from the inside of buildings, most often used nowadays in Poland. For each of the methods, the authors have characterized the innovative thermal insulation materials ae well as the methods of their production, and the methods of assembling of the thermal insulation on buildings’ external walls. The summary indicates the advantages and disadvantages of the individual methods. The authors have made the comparison and evaluation of the methods as well as have indicated the consequences of thermal insulation of external walls from the inside of the building. In the conclusions the authors have given some design and implementation recommendations.
Źródło:
Builder; 2021, 25, 5; 40-43
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing Sleeping Bags According to EN 13537:2002: Details That Make the Difference
Autorzy:
Kuklane, K.
Dejke, V.
Powiązania:
https://bibliotekanauki.pl/articles/89984.pdf
Data publikacji:
2010
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
sleeping bag
mattress
thermal manikin
insulation
European standard
calculation method
Opis:
The European Standard on sleeping bag requirements (EN 13537:2002) describes a procedure to determine environmental temperature limits for safe usage of sleeping bags regarding their thermal insulation. However, there are several possible sources of error related to this procedure. The main aim of this work was to determine the influence of the various measuring parameters on the acuity of the respective parameters in order to judge the requirements. The results indicated that air velocity, mattress insulation and time between unpacking the bag and measurement had a significant impact on the result, with a difference of up to 5–15% in thermal insulation between minimum and maximum allowable parameter levels. On the other hand, manikin weight, thickness of the artificial ground and presence of a face mask were found to have a negligible influence. The article also discusses more general aspects of the standard including the calculation methods used.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2010, 16, 2; 199-216
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
High voltage harmonics induced modifications of PD phase-resolved patterns
Autorzy:
Florkowski, M.
Florkowska, B.
Zydroń, P.
Powiązania:
https://bibliotekanauki.pl/articles/141372.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrical insulation system
diagnostics
harmonics
partial discharges
phase-resolved patterns
Opis:
Partial discharges (PD) are influencing electrical insulating systems of high voltage electrical devices. Typically, in laboratory and diagnostics AC tests focused on measuring and analysis of PD, a pure sinusoidal voltage waveform is assumed. However, in practice the spectral content of the working voltage is rarely so ideal and additional spectral components have a significant impact on the discharge behaviour in electrical insulation systems. In this paper the influence of voltage harmonics on PD behaviour and phase-resolved PD patterns evolution is analysed. The presented experiments were conducted on a specimen representing a gaseous inclusion embedded in electrical insulation. The experimental results showed that various harmonic compositions superimposed on the fundamental sinusoidal waveform have a significant impact on PD intensity and maximum charge. In consequence, the derived patterns of PD phase, and magnitude distributions are distorted, and statistical parameters calculated on their basis are changed. In certain environments, neglecting harmonic content in the testing voltage may lead to a misleading interpretation and assessment of PD severity.
Źródło:
Archives of Electrical Engineering; 2018, 67, 2; 231--246
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of thermal insulation panels made of wood shavings
Autorzy:
Pásztory, Zoltán
Kókai, Péter
Adamik, Péter
Halász, Katalin
Börcsök, Zoltán
Powiązania:
https://bibliotekanauki.pl/articles/2010796.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Drewna
Tematy:
natural insulation
wood shavings utilization
urea formaldehyde
methyl diphenyl diisocyanate
Opis:
Natural insulations made from by-products available in large quantities are growing in importance. In the wood processing industry, among other materials, wood chips and shavings are available in large quantities. The aim of this research was to determine the optimal density of thermal insulation panels made of different wood shavings. Planer and drill shavings of spruce (Picea abies) were used as raw material. The same amount of both types of shavings was compacted. The thermal conductivity of both types of shavings asymptotically approached a value between 0.05 and 0.06 W/mK. After a preliminary experiment, panels were manufactured with densities from 55 to 400 kg/m3 with urea formaldehyde and with methyl diphenyl diisocyanate glue. The thermal conductivity and the bending strength of the panels increased with increasing density. The bending strength of the panels glued with methyl diphenyl diisocyanate was much higher than for the others with the same densities.
Źródło:
Drewno. Prace Naukowe. Doniesienia. Komunikaty; 2021, 64, 207; 73-86
1644-3985
Pojawia się w:
Drewno. Prace Naukowe. Doniesienia. Komunikaty
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie przepływu ciepła w przegrodach z instalacjami centralnego ogrzewania metodą brzegowych równań całkowych
Modelling of transient heat conduction in walls with heating instalations by means of the boundary integral equations method
Autorzy:
Teleszewski, T.J.
Sorko, S.A.
Powiązania:
https://bibliotekanauki.pl/articles/403057.pdf
Data publikacji:
2010
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
izolacje termiczne
metoda elementów brzegowych
thermal insulation
finite element method
Opis:
W artykule zaprezentowano algorytm obliczeń i wyniki obliczeń pól temperatury i przepływu ciepła w przegrodach budowlanych z instalacjami przewodów centralnego ogrzewania metodą brzegowych równań całkowych. Dla zobrazowania dokładności obliczeń zagadnień przepływu ciepła przy użyciu metody elementów brzegowych przedstawiono przykładowe wyniki obliczeń przenikania ciepła w ścianie zewnętrznej jednowarstwowej, porównując je z rezultatem rozwiązania analitycznego. W opracowaniu przedstawiono graficzne wyniki obliczeń pól temperatury, izoterm i adiabat oraz strumienia ciepła w przegrodach, w których znajdują się instalacje c.o. Dokonano porównania grafów cieplnych charakterystyk analizowanych elementów budowlanych z termogramami wykonanymi kamerą termowizyjną.
The paper aim was to present a solution concerning heat conduction problem using boundary element method in walls with central heating. The boundary integral equation method is a numerical method for solving partial differential equations encountered in mathematical physics and engineering. Only the boundary distributions of the unknown functions or one of its derivatives were solved in this method. The boundary integral equation method is the reduction of the dimension of the solution space with respect to physical space by one unit. The boundary element method is an alternative to the finite difference method and the finite element method. Numerical solutions were compared with the results of the theoretical solutions. Examples of heat calculations were presented.
Źródło:
Budownictwo i Inżynieria Środowiska; 2010, 1, 3; 245-250
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Suszenie transformatorów energetycznych na stanowisku pracy technologią grzania prądem niskiej częstotliwości – doświadczenia praktyczne
Practical experience in on-site drying of pow-er transformers with low frequency heating
Autorzy:
Lasota, M.
Owczarek, M.
Powiązania:
https://bibliotekanauki.pl/articles/154375.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator
suszenie izolacji
metoda LFH
transformer
insulation drying
LFH method
Opis:
W artykule przedstawiono stosowane metody suszenia transformatora na miejscu zainstalowania. Podano opis technologii grzania uzwojeń prądem niskiej częstotliwości (LFH). Przedstawiono elementy instalacji, opis przebiegu samego procesu i jego kluczowe parametry. Skuteczność działania metody LFH zaprezentowano na podstawie wybranych projektów, dla jednostek różnej wielkości, napięć i konstrukcji.
The introduction contains general information about presence and distribution of moisture in power transformers. Sources of water as well as corresponding threats influencing transformer operational safety and reliability are presented. Further, the authors briefly describe the methods typically used for on-site transformer drying as alternatives to Low Frequency Heating. The core of the paper is comprised of a detailed description of the LFH method, which is an advanced field service proposition of transformer condition improvement, engineered and deployed in numerous countries by ABB Transformer Service. The LFH installation components as well as the drying process description and key monitored parameters are given. The effectiveness of the LFH method is proven basing upon selected on-site projects pertaining transformers of different sizes, HV level, design and operation regime. Additional focus is placed on the significance of high vacuum in the drying process especially with regard to its effectiveness, which is then comparable with vapour phase factory drying. Finally, examples of the LFH combined with oil reclaiming during on-site projects are given. Through such approach, not only is the actual transformer condition improved and risk of failure diminished, but also the expected transformer lifetime may be significantly extended due to inhibited degradation of the oil-paper insulation system.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 146-151
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozwój rynku pianki szklanej jako materiału izolacyjnego w przemyśle i budownictwie
Development of the glass foam market as an insulating material in industry and construction
Autorzy:
Grzebielec, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/36114038.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
szkło spienione
materiał izolacyjny
właściwości
foamed glass
insulation material
properties
Opis:
Materiały z pianki szklanej są równie dobrym izolatorem jak powszechnie wykorzystywane materiały ze spienionych tworzyw sztucznych czy też wełna mineralna. A w wielu zastosowaniach są materiałem zdecydowanie lepszym. Chodzi chociażby o zastosowania kriogeniczne oraz zastosowania wysokotemperaturowe. Rynek pianek szklanych systematycznie się rozwija i coraz śmielej konkuruje z materiałami, które do tej pory były bezkonkurencyjne, zwłaszcza w branży budowlanej. Artykuł ma na celu przybliżyć właściwości materiału jak i sam rynek materiałów związanych ze spienionymi materiałami szklanymi.
Glass foam materials are as good an insulator as commonly used materials made of foamed plastics or mineral wool. And for many applications, they are a much better material. It is about cryogenic and high temperature applications. The market of glass foams is systematically developing and it competes more and more boldly with materials that have been unrivaled so far, especially in the construction industry. The aim of the article is to present the properties of the material as well as the market of materials related to foamed glass materials.
Źródło:
Szkło i Ceramika; 2022, 73, 1; 44-48
0039-8144
Pojawia się w:
Szkło i Ceramika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improving Sound Transmission Through Triple-Panel Structure Using Porous Material and Sonic Crystal
Autorzy:
Kim, Myong-Jin
Powiązania:
https://bibliotekanauki.pl/articles/177186.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
sound transmission loss
sonic crystal
triple-panel structure
sound insulation
Opis:
Main aim of this study is to combine the characteristics of the sonic crystal (SC) with acoustic panels and porous materials to improve the sound transmission loss (STL) through the triple-panel structure. SCs cause a bandgap centered around a certain frequency (Bragg’s frequency) due to generation of destructive interference. Initially, an analytical method is developed that extends the previous theory of double-panel structure to predict STL through a triple-panel structure. Finite element (FE) simulations are performer to obtain the STL through the triple-panel, which are validated with the analytical predictions. Various configurations are analyzed using the FE method based on the method of inserting the porous material and SCs between the panels to address the combined effect. STL through the triple-panel structure is compared with that through the double-panel structure having the same total weight and total thickness. It is found that the combined structure of the triple panel and the SC with glass wool as filler gives the best soundproof performance for the same external dimensions. For narrow air gaps, filing with glass wool is more advantageous than inserting one row of SC. In addition, the triple panel combined with a SC has better soundproofing than the two-panel counterparts.
Źródło:
Archives of Acoustics; 2019, 44, 3; 533-541
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aparaturowe aspekty pomiaru wyładowań niezupełnych maszyn elektrycznych. Część 1
Equipment aspects of electric machine diagnostics based on a PD. Part I
Autorzy:
Paduch, Piotr
Szymaniec, Sławomir
Powiązania:
https://bibliotekanauki.pl/articles/305097.pdf
Data publikacji:
2020
Wydawca:
Wydawnictwo Druk-Art
Tematy:
maszyny elektryczne
izolacja
diagnostyka maszyn
electric machines
insulation
machine diagnostics
Opis:
Według autorów, w przodujących ośrodkach naukowo-badawczych zajmujących się diagnostyką stanu izolacji uzwojeń maszyn elektrycznych zauważyć można cztery kierunkowe obszary prac badawczych: prace nad opracowywaniem nowych konstrukcji czujników do pomiarów wnz; prace nad opracowaniem uniwersalnego analizatora wnz z ulepszonymi osiągami w zakresie tłumienia szumów i zakłóceń; prace nad opracowaniem urządzeń przenośnych, mobilnych; prace nad opracowaniem coraz to bardziej złożonych analizatorów, umożliwiających pomiary i analizę sygnałów wnz w bardzo szerokim zakresie czasu i częstotliwości, analizatory te umożliwiają wyznaczenie np. funkcji korelacji.
Operation of electric machines is accompanied by partial discharges. Partial discharges have a very complex nature. Together with progressing use of machines, there is a change in the intensity of partial discharges with typical phase-resolved distributions. The diagnostics can be carried out using available partial charge detectors. The author’s solutions regarding detectors and devices for measurements of partial discharges in electric machines in industrial conditions have proved to be successful. Results of measurements of partial discharges in motors depend on: the condition of their insulation, motor load, temperature of windings, humidity, level of external interference, and characteristics of partial discharge detectors and partial discharge analysing devices.
Źródło:
Napędy i Sterowanie; 2020, 22, 5; 50-55
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aparaturowe aspekty pomiaru wyładowań niezupełnych maszyn elektrycznych. Część 2
Equipment aspects of electric machine diagnostics based on a PD. Part II
Autorzy:
Paduch, Piotr
Szymaniec, Sławomir
Powiązania:
https://bibliotekanauki.pl/articles/305192.pdf
Data publikacji:
2020
Wydawca:
Wydawnictwo Druk-Art
Tematy:
maszyny elektryczne
izolacja
diagnostyka maszyn
electric machines
insulation
machine diagnostics
Opis:
RTD to najczęściej stosowane czujniki termorezystorowe w maszynach elektrycznych, które oprócz swojej podstawowej funkcji mogą pełnić również rolę anten do detekcji wyładowań niezupełnych. Koszt stosowanych w maszynach elektrycznych termorezystorów waha się w granicach od kilku do kilkudziesięciu złotych, wyjątkowo kilkaset złotych.
Operation of electric machines is accompanied by partial discharges. Partial discharges have a very complex nature. Together with progressing use of machines, there is a change in the intensity of partial discharges with typical phase-resolved distributions. The diagnostics can be carried out using available partial charge detectors. The author’s solutions regarding detectors and devices for measurements of partial discharges in electric machines in industrial conditions have proved to be successful. Results of measurements of partial discharges in motors depend on: the condition of their insulation, motor load, temperature of windings, humidity, level of external interference, and characteristics of partial discharge detectors and partial discharge analysing devices.
Źródło:
Napędy i Sterowanie; 2020, 22, 5; 56-62
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza FDS w ocenie zawilgocenia izolacji transformatorów
FDS Analysis in Evaluation of Transformer Insulation Moistening
Autorzy:
Walczak, K.
Gielniak, J.
Graczkowski, A.
Morańda, H.
Powiązania:
https://bibliotekanauki.pl/articles/153197.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
metoda FDS
zawilgocenie izolacji transformatora
FDS method
transformer insulation moistening
Opis:
W artykule omówiono istotę modelowania i analizy w metodzie FDS w aspekcie oceny stopnia zawilgocenia izolacji papierowo-olejowej transformatora energetycznego. Przedstawiono czynniki mające wpływ na odpowiedź dielektryczną izolacji transformatora.
In the paper an idea of modeling and analysis in FDS method in aspect of moistening degree evaluation of paper-oil insulation of power transformer was discussed. Parameters having the influence on the dielectric response of the transformer insulation were presented.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 10, 10; 727-729
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania elektryzacji strumieniowej cieczy dielektrycznych
Investigation of streaming electrification in dielectric liquids
Autorzy:
Kędzia, J.
Zmarzły, D.
Powiązania:
https://bibliotekanauki.pl/articles/153312.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
elektryzacja strumieniowa
olej izolacyjny
transformatory
streaming electrification
insulation oil
transformers
Opis:
W artykule przedstawiono problematykę badawczą dotyczącą elektryzacji strumieniowej. Rozwijana była ona w Instytucie Elektroenergetyki w Katedrze Inżynierii Materiałowej i Elektrycznej. Inspirowały ją przede wszystkim zagrożenia izolacji transformatorów energetycznych z wymuszonym przepływem oleju, gdzie zjawiska elektryzacji prowadziły do przebicia izolacji i awarii transformatorów
In paper research problems of streaming electrification is presented. This matter has been developed at the Electrical Engineering Institute in Chair of Material and Electrical Engineering. The research projects were inspired by menace in power transformer insulation with forced oil cooling system. The streaming electrification lead to insulations breakdown and other failures in these systems.
Źródło:
Pomiary Automatyka Kontrola; 2006, R. 52, nr 10, 10; 39-42
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using Clustering Methods for the Identification of Acoustic Emission Signals Generated by the Selected Form of Partial Discharge in Oil-Paper Insulation
Autorzy:
Borucki, S.
Łuczak, J.
Zmarzły, D.
Powiązania:
https://bibliotekanauki.pl/articles/177657.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission method
acoustic signals
partial discharges
insulation
power transformer
Opis:
The article presents the results concerning the use of clustering methods to identify signals of acoustic emission (AE) generated by partial discharge (PD) in oil-paper insulation. The conducted testing featured qualitative analysis of the following clustering methods: single linkage, complete linkage, average linkage, centroid linkage and Ward linkage. The purpose of the analysis was to search the tested series of AE signal measurements, deriving from three various PD forms, for elements of grouping (clusters), which are most similar to one another and maximally different than in other groups in terms of a specific feature or adopted criteria. Then, the conducted clustering was used as a basis for attempting to assess the effectiveness of identification of particular PD forms that modelled exemplary defects of the power transformer’s oil-paper insulation system. The relevant analyses and simulations were conducted using the Matlab estimation environment and the clustering procedures available in it. The conducted tests featured analyses of the results of the series of measurements of acoustic emissions generated by the basic PD forms, which were obtained in laboratory conditions using spark gap systems that modelled the defects of the power transformer’s oil-paper insulation.
Źródło:
Archives of Acoustics; 2018, 43, 2; 207-215
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowe układy izolatorów galwanicznych sygnałów dolnopasmowych
The New Constructions of Insulation Amplifiers for Low-pass Signals
Autorzy:
Bień, A.
Boroń, A.
Szyper, M.
Wetula, A.
Żegleń, T.
Powiązania:
https://bibliotekanauki.pl/articles/151270.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
izolatory galwaniczne
tłumienie zakłóceń wspólnych
insulation amplifiers
common disturbance suppression
Opis:
Artykuł przedstawia właściwości metrologiczne nowych rozwiązań układowych izolatorów galwanicznych dwu rodzajów: z barierą pojemnościową oraz światłowodową. Uzyskano układy odporne na wysokie napięcia wspólne, o szerokim paśmie przenoszenia oraz innych właściwościach, które porównano z parametrami znanych układów. Przeprowadzone wstępne badania aplikacyjne opracowanych urządzeń wskazują na możliwe zastosowania, m. in. w pomiarach elektroenergetycznych.
The article describes a construction and metrological properties of two new insulation amplifier designs. The first amplifier features a capacitive insulation barrier, while the other uses an optical barrier and power transmission. Conducted experiments include estimation of static and frequency responses and nonlinearities, as well as breakdown tests for the capacitive amplifier. Obtained parameters were compared against popular commercial insulation amplifiers' parameters. Comparison shows that presented amplifiers feature the highest breakdown voltage in class, and very high common mode rejection ratio. Besides parameters estimation, preliminary application experiments were conducted for a capacitive amplifier. These experiments consisted acquisition and spectral analysis of an IGBT converter voltage using a resistive divider and the described amplifier. Presented results of these experiments suggest possible application areas, such as electrical power measurements and power electronic converter voltage analysis.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 12, 12; 1008-1011
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Data on acoustic and thermal properties of reflective insulation
Właściwości akustyczne i cieplne izolacji refleksyjnej
Autorzy:
Dachowski, R.
Piotrowski, J. Z.
Koruba, D.
Zender-Świercz, E.
Telejko, M.
Starzomska, M.
Lucas, X.
Powiązania:
https://bibliotekanauki.pl/articles/402505.pdf
Data publikacji:
2014
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
acoustics
reflective insulation
thermal resistance
akustyka
izolacja refleksyjna
opór cieplny
Opis:
The paper presents the test results of acoustic insulation properties of reflective insulation. The experiments were performed for three different types of insulation and two values of air gap, namely 2 cm and 4 cm. A significant reduction of the sound level was recorded. Selected thermal and mechanical properties are also given in the paper.
Źródło:
Structure and Environment; 2014, 6, 1; 38-42
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena ryzyka wystąpienia kondensacji pary wodnej na powierzchni ściany klatki schodowej przy wykorzystaniu MEB
Estimation of risk of surface condensation at staircase wall with BEM
Autorzy:
Werner-Juszczuk, A. J.
Rynkowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/404256.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Symulacji Komputerowej
Tematy:
MEB
kondensacja powierzchniowa
izolacja cieplna
BEM
surface condensation
thermal insulation
Opis:
W pracy przeprowadzono symulację rozkładu temperatury w miejscu połączenia ściany klatki schodowej ze stropem w wariancie z izolacją i bez izolacji w celu określenia ryzyka wystąpienia powierzchniowej kondensacji pary wodnej i określenia zasadności izolacji ścian pomiędzy klatką schodową a lokalem mieszkalnym. Przyjęto różne wartości temperatury oraz wilgotności względnej powietrza wewnętrznego. Obliczenia wykonano za pomocą autorskiego programu komputerowego wykorzystującego algorytm MEB do rozwiązania ustalonego procesu przewodzenia ciepła w obszarach wielospójnych.
In the paper, the temperature distribution in staircase wall – floor junction is determined in order to estimate the risk of surface condensation both with the necessity of insulation of staircase wall. The results were achieved for wall with and without insulation and for various conditions of inner temperature and relative humidity. The simulation was performed with the use of authoring program, assigned for solving the steady heat transfer problems in multi-regions.
Źródło:
Symulacja w Badaniach i Rozwoju; 2015, 6, 1; 57-65
2081-6154
Pojawia się w:
Symulacja w Badaniach i Rozwoju
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie modelu regresji do wyznaczenia współczynnika izolacyjności akustycznej przegrody niejednorodnej
Application of the regression model to determine sound insulation of a heterogeneous baffle
Autorzy:
Majkut, Leszek
Olszewski, Ryszard
Powiązania:
https://bibliotekanauki.pl/articles/315284.pdf
Data publikacji:
2019
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
izolacyjność akustyczna
modelowanie
analiza regresji
sound insulation
modelling
regression analysis
Opis:
W artykule przedstawiono zastosowanie modelu regresji do oszacowania współczynnika izolacyjności akustycznej przegrody niejednorodnej na przykładzie przegrody dwumateriałowej. Sformułowano model regresji, następnie zastosowano go do wyznaczenia izolacyjności płyty. Uzyskane wyniki porównano z wynikami pomiarów.
Paper discussed the regression model which was used to determine the sound insulation of a two-materials baffle based on the known sound insulation of its layers.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2019, 20, 12; 175-178
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Pressure Equalisation Elements on the Quality of Insulating Glass Units
Autorzy:
Respondek, Z.
Powiązania:
https://bibliotekanauki.pl/articles/2064912.pdf
Data publikacji:
2018
Wydawca:
STE GROUP
Tematy:
quality of building products
insulating glass unit
pressure
thermal insulation
Opis:
Continuous increase of expectations concerning improvement in quality of building partitions by means of increasing their thermal insulation properties brings, among others, a need of modification in standards that have been applied to the double glazed windows so far. Triple-glazed and quadruple-glazed IGUs are used more and more often. Such elements have better thermal properties, but they are more prone to deflection and stress resulting from climatic load, i.e. changes in temperature, atmospheric pressure and wind load. Due to the above certain concepts occurred that consist in equalising gas pressure in the gas-filled gaps with the atmospheric pressure. The article contains assessment of such solutions in the context of providing suitable technical parameters of glass panes: thermal insulation and susceptibility to climatic load. It was stated that the pressure-equalizing elements (capillaries) can result in a significant reduction in the quality of the glass partition in the event of the argon purging chamber or damage to the low-E emissions. The lower risk of using required thermal properties occurs when periodically active valves are used, they operate only in case of extreme pressure level differences. Further analysis concerned the idea of pressure equalisation between the gaps of a triple-glazed unit, as that can be done by using an edge spacer of appropriate design. On the basis of comparative analysis of static values it was shown that it is a reasonable solution. Such a unit maintains the properties of a tight unit, while the possibility of gas exchange between the gaps leads to relief of the central glass pane in the unit, thus allowing for decreasing its thickness to 2 mm.
Źródło:
Multidisciplinary Aspects of Production Engineering; 2018, 1, 1; 47--53
2545-2827
Pojawia się w:
Multidisciplinary Aspects of Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methodology for assessment of the cost effectiveness of simple energy efficient investments
Autorzy:
Szafranko, Elżbieta
Powiązania:
https://bibliotekanauki.pl/articles/2065620.pdf
Data publikacji:
2020
Wydawca:
Politechnika Częstochowska
Tematy:
cost effectiveness
energy efficient
thermal insulation
opłacalność
energooszczędność
izolacja cieplna
Opis:
The development of energy efficient buildings has been on the increase in recent years. This trend in architectural engineering reflects both the binding legal regulation and the rational approach of investors to the construction or refurbishment of buildings. When planning such an investment, it is necessary to scrutinize the underlying guidelines and the conditions in which the building will be developed, as well as its future useful life. Economic analysis of the effectiveness of investments in the building sector employs simple and discounted methods. Depending on the scope and complexity of envisaged construction work, it is possible to apply methods from both groups. However, simple methods should suffice for simple building projects, an example of which will be discussed in the article. Three variants of planned additional thermal insulation of external walls of a residential building will be presented. The results of our calculations showed that the payback period for such an investment would be too long, which is why it is recommended to combine the thermal insulation of outer walls with some broader measures so as to shorten the time needed to achieve a good return on investment ratio.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2020, 9, 2; 111--119
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Production and characterization of polyurethane/expanded graphite composites for industrial food preservation
Otrzymywanie i charakterystyka kompozytów poliuretan/grafit ekspandowany do konserwacji żywności metodą przemysłową
Autorzy:
Güngör Ertuğral, Tuğba
Powiązania:
https://bibliotekanauki.pl/articles/2202592.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
polyurethane
expanded graphite
composites
insulation
poliuretan
grafit ekspandowany
kompozyty
izolacja
Opis:
Thermal insulation materials extend the shelf life of food and reduce energy consumption. Polyurethane (PU) insulation materials are often used to keep food hot and cold. Improving the thermal insulation properties of PU can significantly contribute to energy savings and lower food-related costs in the food and pharmaceutical industries. Polyurethane/expanded graphite (PU/EG) composites were obtained by hot-pressing by adding expanded graphite (EG) to PU foams. Composites with 0.05%, 5%, and 10% EG were characterized by Fourier transform infrared spectroscopy (FTIR), scanning electron microscope (SEM), and thermogravimetric analysis (TGA).
Materiały termoizolacyjne wydłużają okres przydatności do spożycia żywności oraz zmniejszają zużycie energii. Poliuretanowe (PU) materiały izolacyjne są często stosowane do przechowywania żywności na gorąco i na zimno. Poprawa właściwości termoizolacyjnych PU może znacząco przyczynić się do oszczędności energii i obniżenia kosztów związanych z żywnością w przemyśle spożywczym i farmaceutycznym. Kompozyty poliuretan/ekspandowany grafit (PU/EG) wytworzono metodą prasowania na gorąco poprzez dodanie ekspandowanego grafitu (EG) do pianek PU. Kompozyty z udziałem 0,05% mas., 5% mas. i 10% mas. EG scharakteryzowano za pomocą spektroskopii w podczerwieni z transformacją Fouriera (FTIR), skaningowego mikroskopu elektronowego (SEM) i analizy termograwimetrycznej (TGA).
Źródło:
Polimery; 2022, 67, 11-12; 588--594
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Textile Waste from Woollen Yarn Production as Raw Materials for Thermal Insulation Products
Autorzy:
Vėjelis, Sigitas
Vaitkus, Saulius
Sankauskaitė, Audronė
Kremensas, Arūnas
Šeputytė Jucikė, Jurga
Powiązania:
https://bibliotekanauki.pl/articles/2200769.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
textile waste
sheep wool
polylactide fibre
thermal insulation
thermal conductivity
Opis:
In the current research, waste from woollen yarn production was analysed. Woollen yarn waste as raw material was used for the production of soft thermal insulation mats. Two types of mats were produced in a textile plant: thermally untreated and thermally treated. Properties such as the fibre composition, structure, and thermal conductivity of the thermally untreated and thermally treated mats were studied. During the composition analysis of the woollen yarn waste, the quantity of long, medium length, and short fibres was determined. The content of fats, salts, and other organic and synthetic impurities was investigated. The micro and macrostructures and contact zones between the fibres and the binding material were analysed. The dependences of the thermal conductivity on the density of the thermally untreated and thermally treated composites were obtained.
Źródło:
Fibres & Textiles in Eastern Europe; 2022, 5 (151); 8--16
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Degradacja izolacji uzwojeń maszyn elektrycznych pod wpływem czasu ich eksploatacji
Degradation of windings insulation of electrical machines conditioned by the time of exploiting
Autorzy:
Glinka, T.
Polak, A.
Decner, A.
Powiązania:
https://bibliotekanauki.pl/articles/329386.pdf
Data publikacji:
2005
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
diagnostyka
izolacja
maszyny elektryczne
degradacja
diagnostics
insulation
electrical machines
degradation
Opis:
Wyniki diagnostyki izolacji maszyn elektrycznych przeprowadzonej napięciem stałym umożliwiają wprowadzenie punktowej oceny stopnia degradacji izolacji. W artykule zaproponowano pięciostopniową skalę oceny (tabela 1). Punktowa skala ceny degradacji izolacji została poparta wynikami pomiarów, przeprowadzonych na prądnicach prądu stałego o parametrach: PN=4150kW; UN=730V; nN=500obr/min (rys. 2-6). W tabeli 2 zestawiono wyniki badań izolacji 20 maszyn przebadanych w 2000 i 2005 roku. Wyższa ocena niektórych maszyn w 2005 roku świadczy o tym, że maszyny zostały przezwojone.
Results of dc voltage diagnostic tests of electric machines' insulation (Fig.1) make possible the evaluation of insulation's degree of degradation in accordance with marking system. The paper presents marking system set from 5 to 1 - see Table 1. The relationship between marking system and characterictics/parameters of insulation system has been shown, basing on results of diagnostic tests of armature windings' insulation of dc generator rated at 4150 kW; 730 V; 500 rpm (Figs.2-6). Table 2 gives the marks for technical assessment of insulation of 20 machines tested in 2000 and 2005. If the marks for 2005 are higher than for 2000, then it means that the machines have been rewound.
Źródło:
Diagnostyka; 2005, 33; 217-222
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies