Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "implanty kości" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Bioszkła i organiczno-nieorganiczne kompozyty dla inżynierii tkankowej kości
Bioglasses and organic-inorganic composites for bone tissue engineering
Autorzy:
John, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/172492.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Chemiczne
Tematy:
biomateriały
bioszkło
organiczno-nieorganiczne hybrydy
hydroksyapatyt
implanty kości
in vitro
biomaterials
bioglasses
organic-inorganic hybrid
hydroxyapatite
bone implants
Opis:
The most demanded biomaterials for bone tissue engineering could be classified in two main sol-gel derived groups: bioglasses and organic-inorganic composites. The first of these include bioactive ceramics such as calcium phosphates (Tab. 2) [1], glasses and glass ceramics [2], and so-called inert ceramics (Tab. 1) such as Al2O3, zirconium and titanium dioxide, and carbon-based materials [3, 4]. Second-group of compounds constitute bioactive organic-inorganic hybrids, generally based on organic matrix and various inorganic dopants. Biomaterials in contact with human plasma and bone stem cells form, on their surface, hydroxyapatite Ca10(PO4)6(OH)2 (HAp) and its derivatives (Tab. 2). HAp-layer initiates bone growth and reconstruction of treated fragment (Fig. 2). These materials, due to the high degree of biocompability are considered as the most valuable compounds for bone surgery [5]. Extremely rapid development of biomaterials used in medicine caused the production of implants with different properties (Scheme 1). The real revolution and technological progress have brought biomimetic composites that mimic naturally occurring solutions in living organisms. The role of such implants is not only replacing the damaged parts of body, but – due to the appropriate morphology and composition – stimulating the growth of living cells (Fig. 3) and final bone regeneration. This article is devoted to this type of biomaterials proposed for bone tissue engineering.
Źródło:
Wiadomości Chemiczne; 2012, 66, 1-2; 21-39
0043-5104
2300-0295
Pojawia się w:
Wiadomości Chemiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania powierzchni klamer NiTi użytych w zespoleniach złamań jarzmowo-szczękowo-oczodołowych
Surface studies of NiTi staples used in zygomatico-maxillo-orbital osteosynthesis
Autorzy:
Lekston, Z.
Łosiewicz, B.
Winiarski, A.
Jędrusik-Pawłowska, M.
Kromka-Szydek, M.
Miernik, K.
Powiązania:
https://bibliotekanauki.pl/articles/283947.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
klamry NiTi
zespolenia kości twarzoczaszki
implanty
NiTi staples
osteosynthesis
implants
Źródło:
Engineering of Biomaterials; 2010, 13, no. 96-98; 29-33
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimal selection of dental implant for different bone conditions based on the mechanical response
Autorzy:
Roy, S.
Das, M.
Chakraborty, P.
Biswas, J. K.
Chatterjee, S.
Khutia, N.
Saha, S.
Roychowdhury, A.
Powiązania:
https://bibliotekanauki.pl/articles/307549.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
wytrzymałość kości
implanty stomatologiczne
analiza FEM
pacjent
bone condition
porous dental implant
FE Analysis
patient specific
Opis:
Bone quality varies from one patient to another extensively; also, Young’s modulus may deviate up to 40% of normal bone quality, which results into alteration of bone stiffness immensely. The prime goal of this study is to design the optimum dental implant considering the mechanical response at bone implant interfaces for a patient with specific bone quality. Method. 3D model of mandible and natural molar tooth were prepared from CT scan data while, dental implants were modelled using different diameter, length and porosity and FE analysis was carried out. Based on the variation in bone density, five different bone qualities were considered. First, failure analysis of implants, under maximum biting force of 250N had been performed; next, the implants, those survived were selected for observing the mechanical response at bone implant interfaces under common chewing load of 120N. Result. Maximum Von Mises stress did not surpass the yield strength of the implant material (TiAl4V). However, factor of safety of 1.5 was considered and all but two dental implants survived the design stress or allowable stress. Under 120N load, distribution of Von Mises stress and strain at the bone-implant interface corresponding to the rest of the implants for five bone conditions were obtained and enlisted. Conclusion. Implants, exhibiting interface strain within 1500-3000 microstrain range show the best bone remodelling and osseointegration. So, implant models, having this range of interface strains were selected corresponding to the particular bone quality. A set of optimum dental implants for each of the bone qualities were predicted.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 2; 11-20
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Supersprężyste implanty NiTi dla ciągłej dystrakcji kości
Superelastic NiTi implants for continuous bone distraction
Autorzy:
Lekston, Z.
Stróż, D.
Morawiec, H.
Powiązania:
https://bibliotekanauki.pl/articles/284862.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stop Ni-Ti
nadsprężyste implanty
ciągła dystrakcja kości
sprężyny dla kranioplastyki
NiTi alloy
superelastic implants
continuous bone distraction
springs for cranioplasty
Opis:
Zasadniczym założeniem tej pracy było osiągnięcie nadsprężystości implantów użytych do dystrakcji kości dla korekcji deformacji czaszkowo-twarzowych. Opisano dwie możliwości przygotowania nadsprężystych, sprężynowych implantów użytych w kranioplastyce. W pierwszej użyto nadsprężyste, proste druty jako sprężyny w kształcie Omega lub U. Nadsprężystość jest indukowana w drutach przez wstępną deformację na zimno i wyżarzanie poniżej temperatury rekrystalizacji. Struktura dyslokacyjna i mało-kątowe granice ziaren są charakterystyczne dla struktury tych drutów. Druga możliwość indukowania nadsprężystości w sprężynach pierścieniowych bazuje na umocnieniu wydzieleniowym. W tym celu użyto stop z wyższą zawartością niklu (51%at.), w którym wydzielanie koherentnych cząstek fazy Ni4Ti3 prowadzi do umocnienia osnowy i pozwala osiągnąć wyraźne plateau naprężania na krzywej naprężenie-odkształcenie. Przydatność uzyskanych implantów wykazano w zastosowaniach klinicznych.
The basic assumption of his work was to achieve the superelastic behaviour of implants used for bone distraction for correction craniomaxillofacial deformities. This paper describes two possibilities of preparing the superelastic spring implants used in cranioplasty. In the first one the superelastic straight wires were used for Omega and U-shape springs. The superelasticity is induced to the wires by a proper cold deformation and annealing below the recrystallization temperature. Dislocation cells and low angle grain boundaries are characteristic for the structure of these wires. The second possibility of the superelasticity induction into ring springs is based on the precipitation hardening. For this purpose an alloy with higher amount of nickel (51 at%) was used at which precipitation of the Ni4Ti3 coherent particles leads to the matrix hardening and allows to achieve a distinguish stress plateau on the stress-strain curve. The obtained implants have shown their usefulness in clinical applications.
Źródło:
Engineering of Biomaterials; 2007, 10, no. 67-68; 38-42
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies