Wyświetlanie 1-3 z 3
Tytuł:
Assessment of gold with titanium alloy weldability in conditions of a dental technique laboratory
Autorzy:
Jania, G.
Żmudzki, J.
Topolska, S.
Powiązania:
https://bibliotekanauki.pl/articles/24200598.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
titanium alloy
gold
laser welding
prosthetic
implant denture
microstructure
stop tytanu
złoto
spawanie laserowe
protetyka
proteza implantu
mikrostruktura
Opis:
Purpose: In dental practice, there is necessary to weld gold with titanium under the conditions of a dental technique laboratory, which is difficult. The aim was to assess the weldability of pure gold with the titanium alloy Ti6Al4V using a prosthetic laser welding machine. Design/methodology/approach: Gold wire in a diameter of 0.4 mm made with the use of a jewellery drawbar (GOLDPORT, Szczecin, Poland) was welded to a titanium alloy Ti6Al4V substrate of dental implant abutment screw (MegaGen). Dental laser welding parameters (Bego Laser Star T plus) were 230 V; 6.5 ms; 2.5 Hz; laser spot 0.3 mm, and argon blow. Samples were included in resin, ground (500-4000 SiC), polished (Al2O3 suspension) and etched (Kroll solution) per 20 s before observation under a light microscope. Findings: There were well-welded and poorly joined zones. The discontinuities and voids there were not visible or sparse next to the initial weld point. Dendritic structure at well-welded remelting zones and two-phase microstructure of titanium and Ti3Au phase were found. The heat-affected zone was about of 20 microns. Research limitations/implications: Light microscopy was used, and precise phase identification required further investigations. Weld strength assessment requires further micro-hardness and load-bearing ability tests. Weldability concerns the model system with pure gold. Practical implications: In the case of elements with dimensions below 0.4 mm, the use of a laser with a smaller spot should be considered for better control of the remelting zone and mechanical positioning of the elements in order to stabilize and avoid discontinuities and voids. Originality/value: Prosthetic laser welding with a laser spot about of 0.3 mm allows to obtain well-welded parts of 0.3 mm in diameter under stable stitching conditions and higher than 0.4 mm in dimensions.
Źródło:
Archives of Materials Science and Engineering; 2022, 118, 1; 36--41
1897-2764
Pojawia się w:
Archives of Materials Science and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Full Contoured Tooth-Implant Supported 3-Pointic All-Ceramic Denture During Occlusal Load Transfer in Lateral Region
Autorzy:
Żmudzki, J.
Malara, P.
Chladek, G.
Powiązania:
https://bibliotekanauki.pl/articles/356267.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
biomaterials
denture
zirconium oxide
titanium implant
bone tissue
Opis:
Implant and a tooth supported dentures are avoided by dentists because of uneven distribution of occlusal loads between a stiffer implant and a more pliable tooth. The hypothesis was that a 3-point all-ceramic bridge supported on a natural second premolar tooth and a two-pieces typical implant bears safely mastication loads. The finite element analysis showed that the implant splinted by all-ceramic zirconium bridge with the second premolar was safe under lateral mastication load, but there was found an overload at wide zone of bone tissue around the implant under the load of 800 N. The patients can safely masticate, but comminution of hard food should be avoided and they should be instructed that after such an indiscretion they need to contact a dental professional, because, in spite of integrity of the prosthesis, the bone tissue around the implant may fail and there is a hazard of intrusion of the tooth.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 2A; 843-846
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the retention characteristics of various stud attachment systems for implant retained overdenture
Autorzy:
Gonuldas, F.
Tokar, E.
Ozturk, C.
Powiązania:
https://bibliotekanauki.pl/articles/306253.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
implant
zamocowanie
proteza
retencja
overdenture
implant-supported dental prosthesis
denture precision attachment
retention
Opis:
The purpose of the study was to analyze and compare retention characteristics of different stud attachments including a standard and two low profile attachments on two implant embedded test models. Methods: Three different stud attachment systems (Ball attachment and two different low profile stud attachments – Equator and Locator) were used in this study. Two dental implants were placed vertically into a custom-made acrylic resin block within a 22 mm distance. Strong and soft nylon inserts of each attachment system were tested using cyclic dislodgement test for 24 months simulation. Maximum forces during the test were recorded and 10 consecutive data at baseline, 1st to 24th months were analyzed. Repeated measures ANOVA and post-hoc Tukey’s test ( p 0.05) were used for statistical analysis. Results: Retentive forces of the tested attachments varied from 30.7 to 93.75 N at the baseline. The highest initial mean retention (93.75 N) was observed in Group LC (locator attachment with clear nylon inserts) and the lowest initial mean retention (30.7 N) was detected in both Group BO (ball attachment with orange nylon inserts) and Group EY (equator with yellow nylon inserts). After the 24 months simulation, locator groups illustrated more light retention than other tested attachment systems. Conclusions: All tested attachment systems showed a significant decrease in retention value at the end of the simulated period. The locator attachment had significantly higher reduction in retention values compared to other low profile stud attachment equator and ball attachment.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 4; 135-141
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies