Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "hyphenated techniques" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Food quality control by hyphenated separation techniques
Autorzy:
Walczak, J.
Pomastowski, P.
Buszewski, B.
Powiązania:
https://bibliotekanauki.pl/articles/2052456.pdf
Data publikacji:
2015
Wydawca:
Akademia Bialska Nauk Stosowanych im. Jana Pawła II w Białej Podlaskiej
Tematy:
food analysis
hyphenated techniques
liquid chromatography
mass spectrometry
Opis:
Food as complex mixture of proteins, lipids, vitamins, etc. cannot be separated and identified by using in only one method. This article presents a revision on the hyphenated chromatographic techniques and methods used in food analysis and described main application in food science research, and determination of xenobiotics and their metabolites in environmental. Also article discusses applications of “omics” in food analysis (proteomics, transcriptomics, genomics, metabolomis) and new discipline of – foodomics.
Źródło:
Health Problems of Civilization; 2015, 09, 1; 33-38
2353-6942
2354-0265
Pojawia się w:
Health Problems of Civilization
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analityka specjacyjna wybranych metali i metaloidów - arsen
Autorzy:
Michalski, R.
Szopa, S.
Jabłońska, M.
Łyko, A.
Powiązania:
https://bibliotekanauki.pl/articles/273732.pdf
Data publikacji:
2012
Wydawca:
Roble
Tematy:
arsen
techniki łączone
analityka specjacyjna
arsenic
hyphenated techniques
speciation analysis
Źródło:
LAB Laboratoria, Aparatura, Badania; 2012, 17, 2; 6-14
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analityka specjacyjna wybranych metali i metaloidów - antymon i tal
Autorzy:
Michalski, R.
Szopa, S.
Jabłońska, M.
Łyko, A.
Powiązania:
https://bibliotekanauki.pl/articles/273919.pdf
Data publikacji:
2012
Wydawca:
Roble
Tematy:
antymon
tal
analiza specjacyjna
techniki łączone
antimony
thallium
speciation analysis
hyphenated techniques
Źródło:
LAB Laboratoria, Aparatura, Badania; 2012, 17, 3; 26-33
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nanocząstki tlenku tytanu(IV) : zastosowanie w produktach użytkowych, badania właściwości i oznaczanie techniką spektrometrii mas z plazmą indukcyjnie sprzężoną pracującą w trybie pojedynczej cząstki
Titanium dioxide nanoparticles : application in consumer products, study of properties and determination by single particle inductively coupled plasma – mass spectrometry
Autorzy:
Gruszka, Jakub
Malejko, Julita
Godlewska-Żyłkiewicz, Beata
Powiązania:
https://bibliotekanauki.pl/articles/172064.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Chemiczne
Tematy:
nanocząstki tlenku tytanu(IV)
rozdzielanie
techniki łączone
titanium dioxide nanoparticles
separation
hyphenated techniques
Opis:
The rapid growth in the production and use of nanomaterials is observed in recent years. Nanoparticles of titanium dioxide (TiO2NPs) are one of the most frequently used nanomaterials. Sunscreens, food additives, food contact materials and textiles are the major fields of current application of TiO2NPs. Due to increasing use of nanomaterials in daily life and thus increasing exposure to them, concerns have been raised about their safety. Likely routes of human exposure to released TiO2NPs as well as their health and environmental effects are presented in this paper. At present, our knowledge about the risk of nanomaterials is incomplete. However, it is known that toxicity of nanoparticles depends on their size, shape, crystal structure, surface morphology, surface area, charge, concentration and solubility (the possibility of dissolution into ionic forms). Therefore, it is necessary to use several complementary analytical techniques to fully characterize the NPs. Common approaches used for the characterization of nanomaterials include microscopy based techniques e.g. transmission electron microscopy (TEM), X-ray techniques e.g. X-ray diffraction (XRD), methods based on optical properties e.g. dynamic light scattering (DLS). Separation of nanoparticulate and ionic forms of metal can be accomplished using chromatographic techniques (such as high performance liquid chromatography (HPLC), size exclusion chromatography (SEC), hydrodynamic chromatography (HDC)) or capillary electrophoresis (CE). Size-resolved NPs and dissolved (ionic) fractions can be further characterized by on-line detectors, such as ICP MS. Recently, single particle inductively coupled plasma mass spectrometry (sp ICP MS) has been gaining increasing attention as a technique for detection, characterization, and quantification of nanoparticles. This technique provides information on individual particles, including particle size, number size distribution, particle number concentration and mass concentration. In addition, sp ICP MS can distinguish dissolved and nanoparticulate forms of an element. The fundamentals, advantages and limitations of this technique, as well as its application for the characterization and quantification of TiO2NPs in different matrices (consumer products, food and environmental samples) are reviewed in this paper.
Źródło:
Wiadomości Chemiczne; 2019, 73, 5-6; 367-400
0043-5104
2300-0295
Pojawia się w:
Wiadomości Chemiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nanosrebro : zastosowanie, migracja i metody oznaczania
Nanosilver : uses, migration and methods of determination
Autorzy:
Malejko, J.
Godlewska-Żyłkiewicz, B.
Powiązania:
https://bibliotekanauki.pl/articles/171890.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Chemiczne
Tematy:
nanocząstki srebra
migracja
biodostępność
rozdzielanie
techniki łączone
silver nanoparticles
migration
bioavailability
separation
hyphenated techniques
Opis:
The rapid growth in the commercial application of silver nanoparticles (AgNPs) will certainly increase the exposure to these metals among humans and in the environment. Nano-size silver particles have a broad spectrum of antimicrobial activity and therefore are incorporated into various materials, including medical textiles, which claim to prevent infection, as well as more common textiles, like anti-odour sportswear, underwear, socks and gloves. On the market there is also a variety of home consumer products claiming to contain nanosilver, for example disinfecting sprays (to disinfect hard surfaces, towels, sheets, and clothing), kitchen cutting boards, washing machines, refrigerators, dishwashers, pillows and mattresses, toothbrushes, toilet seats, water filters, and cosmetics. Nanosilver is added to food contact materials to preserve the packaged food for a particularly long period of time by inhibiting the growth of microbes. There is a number of in vitro studies showing cytotoxic effects and genotoxic DNA damaging capacity of AgNPs to a variety of mammalian cell types [24]. However, there are only a few in vivo studies on their genotoxicity. Likely routes of human exposure to released nanoparticles include inhalation, ingestion and dermal penetration. Evaluation of the health impact of AgNPs requires information on how readily and in what forms this substance can be released from the material. At present, the availability of such data is limited (Tab. 1). Size of metal-based nanoparticles is an important factor determining their physical and chemical properties as well as their bioavailability and toxicity. The methods used for the size characterisation of AgNPs in different matrices (consumer products, biological and environmental samples) (Tab. 2), as well as for speciation analysis of various forms of silver, namely AgNPs and silver ions, are reviewed in this paper. Off-line methods such as centrifugal ultrafiltration, (ultra)centrifugation, dialysis, and cloud point extraction are used in order to distinguish between nanoparticles and dissolved forms of silver. Field-flow fractionation (FFF) in different modes is used for nanoparticle size dependent separation [50]. Size-resolved AgNPs fractions are further characterised by on-line detectors, such as UV-Vis, ICP OES or ICP MS. ICP MS in single-particle detection mode is used for simultaneous determination of nanosilver and silver ions [38]. The application of capillary electrophoresis [40] and liquid chromatography [41, 42] for the separation of nano and ionic forms of silver is also discussed in this work.
Źródło:
Wiadomości Chemiczne; 2015, 69, 9-10; 847-867
0043-5104
2300-0295
Pojawia się w:
Wiadomości Chemiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mobilne chromatografy gazowe łączone ze spektrometrami ruchliwości jonów do zastosowań w analizie zanieczyszczeń środowiska
Portable gas chromatographs joint with ion mobility spectrometers for analysis of environmental pollutants
Autorzy:
Grabka, M.
Budzyńska, E.
Witkiewicz, Z.
Puton, J.
Jasek, K.
Powiązania:
https://bibliotekanauki.pl/articles/270849.pdf
Data publikacji:
2017
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
spektrometria ruchliwości jonów
chromatografia gazowa
GC-IMS
analityczne techniki łączone
ion mobility spectrometry
gas chromatography
analytical hyphenated techniques
Opis:
W ostatnich latach w analizie zanieczyszczeń środowiska obserwuje się silną tendencję do prowadzenia analiz w miejscu występowania analitów (on-site). Podejście takie minimalizuje problemy przechowywania i transportu próbek z miejsca ich pobrania do laboratorium stacjonarnego, jak również skraca czas od pobrania próbki do uzyskania wyniku analizy. Obecnie do prowadzenia analiz polowych stosowane są między innymi mobilne urządzenia będące połączeniem chromatografu gazowego ze spektrometrem ruchliwości jonów (ang. Gas Chromatography – Ion Mobility Spectrometry – GC-IMS). Zalety techniki GC-IMS i możliwość jej potencjalnego wykorzystania w urządzeniach przenośnych dostrzeżono już w latach 70. XX wieku. W praktyce połączenie chromatografu gazowego ze spektrometrem IMS nastręczało wiele problemów technicznych. Dopiero wprowadzenie licznych rozwiązań konstrukcyjnych dedykowanych dla GC-IMS oraz miniaturyzacja chromatografów gazowych i spektrometrów ruchliwości jonów, o względnie prostej budowie i małym zużyciu energii, umożliwiły konstrukcję hybrydowych przyrządów przenośnych. Kompaktowe urządzenia są wykorzystywane w miejscach, w których przyrządy stacjonarne nie mają zastosowania, np. w polowych analizach zanieczyszczeń środowiska, sygnalizatorach skażeń bojowymi środkami trującymi czy w sondach kosmicznych. W dziedzinie analitycznych urządzeń przenośnych przyrządy GC-IMS stanowią alternatywę dla urządzeń GC-MS, przewyższając je pod względem mobilności, prostoty konstrukcji oraz niektórych właściwości analitycznych (np. bardzo dobrej wykrywalności). Urządzenia tego typu charakteryzują się jednak niższą selektywnością niż przyrządy GC-MS. W pracy zawarto opis rozwoju mobilnych urządzeń GC-IMS od koncepcji poprzez pierwsze konstrukcje aż do obecnie dostępnych rozwiązań.
In the chemical analysis of environmental pollutions there is a strong tendency to perform fast on-site analysis using portable devices. This approach minimizes the problem of sample storage and transport from the place of collection to the stationary laboratory as well as reduces sampling-to-result time. Recently on-site analysis are often performed using mobile devices which are a combination of a gas chromatograph and ion mobility spectrometer (GC-IMS). Advantages of GC-IMS technique and its suitability for application as portable devices has already been noticed in the seventies of the twentieth century. As the first attempts have shown, the combination of a gas chromatograph and IMS detector in one device posed numerous technical issues. The gradual introduction of dedicated design solution and miniaturization of gas chromatographs and ion mobility spectrometers, allowed the construction of portable devices based on the joint technique. Compact devices are used in places where stationary instruments do not fit, e.g.: on-site analysis of environmental pollutions, portable CWA detectors or space probes. In the field of mobile analytical devices GC-IMS technique constitutes an alternative to GC-MS. GC-IMS devices exceeds GC-MS instruments in terms of mobility, simplicity, and some certain analytical characteristics (e.g. significantly lower detection limits). However device based on GC-IMS technique have a much lower selectivity than GC-MS instruments. This study presents an overview of the development of mobile GC-IMS devices from conception through the first constructions to currently available solutions in this domain.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2017, 22, 2; 107-116
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies