Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "humidity sensor" wg kryterium: Temat


Wyświetlanie 1-10 z 10
Tytuł:
Heating control of heated twin radiosonde humidity sensor based on DMC
Autorzy:
Sun, N.
Zhang, Y.
Zhang, W
Cheng, E.
Liu, Y.
Powiązania:
https://bibliotekanauki.pl/articles/260018.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
DMC
twin heated humidity sensor
expanded responsible curve
heating control
Opis:
In order to effectively solve condensation and icing problems of radiosonde in low-temperature environment at high altitude, humidity sensor heated automatic alternately to remove pollution and improve the measurement accuracy. Heat experiments obtained the curve of rising temperature and responsible time on heated twin humidity sensor in normal temperature and pressure, by expanded responsible curve to obtain heated model of twin heated humidity sensor and by the analysis of heating model, use DMC and PID control for heating respectively. Simulation results show that the DMC control meets the practical requirements of measure at high altitude.
Źródło:
Polish Maritime Research; 2016, S 1; 52-58
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polimerowe czujniki wilgotności na bazie polietylenoiminy
Investigation of polymer humidity sensors based on polyethyleneimine
Autorzy:
Jasiński, G.
Chachulski, B.
Jasiński, P.
Nowakowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/153812.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
czujnik wilgotności
polietylenoimina
sieciowanie polimerów
pomiary impedancji
humidity sensor
polyethyleneimine
cross-linking of polymers
impedance measurements
Opis:
Przedstawiono wyniki badań nad polimerowymi czujnikami wilgotności na bazie polietylenoiminy (PEI). PEI jest rozpuszczalną w wodzie poliaminą. Praktyczne wykorzystanie PEI możliwe jest po ograniczeniu jej rozpuszczalności w wodzie. W pracy opisano metody chemicznej modyfikacji filmu polimerowego, jak również stosowane rozwiązania konstrukcyjne, mające na celu poprawę trwałości i właściwości metrologicznych czujników wilgotności. Główną metodą określania parametrów czujników jest pomiar ich widm impedancyjnych.
Properties of polymer humidity sensors based on polyethyleneimine (PEI) are presented. PEI is a water-soluble polyamine. Water resistance improvement is required for a practical usage of this material. Influence of various polymeric film chemical modification methods, as well as various sensor construction improvements on the sensor stability, durability and performance has been investigated. Basic sensors properties are characterised by impedance spectroscopy.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 3, 3; 106-109
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Residual life estimation of fabricated humidity sensors using different artificial intelligence techniques
Autorzy:
Bhargava, C.
Aggarwal, J.
Sharma, P. K.
Powiązania:
https://bibliotekanauki.pl/articles/201564.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
composite material
artificial intelligence
humidity sensor
accelerated life testing
SEM
materiał kompozytowy
sztuczna inteligencja
czujnik wilgotności
Opis:
Background: a humidity sensor is used to sense and measure the relative humidity of air. A new composite system has been fabricated using environmental pollutants such as carbon black and low-cost zinc oxide, and it acts as a humidity sensor. Residual life of the sensor is calculated and an expert system is modelled. For properties and nature confirmation, characterization is performed, and a sensing material is fabricated. Methodology: characterization is performed on the fabricated material. Complex impedance spectroscopy (CIS), Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD) and scanning electron microscopy (SEM) are all used to confirm the surface roughness, its composite nature as well as the morphology of the composite. The residual lifetime of the fabricated humidity sensor is calculated by means of accelerated life testing. An intelligent model is designed using artificial intelligence techniques, including the artificial neural network (ANN), fuzzy inference system (FIS) and adaptive neuro-fuzzy inference system (ANFIS). Results: maximum conductivity obtained is 6.4£10−3 S/cm when zinc oxide is doped with 80% of carbon black. Conclusion: the solid composite obtained possesses good humidity-sensing capability in the range of 30–95%. ANFIS exhibits the maximum prediction accuracy, with an error rate of just 1.1%.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2019, 67, 1; 147-154
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Applications of regression methods to humidity sensors calibration
Zastosowanie metod regresji w kalibracji sensorów wilgotności
Autorzy:
Majewski, J.
Boyko, O.
Powiązania:
https://bibliotekanauki.pl/articles/158930.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
metoda klasyczna kalibracji liniowej
metoda odwrotna kalibracji liniowej
kalibracja sensorów wilgotności
humidity sensor calibration
classical calibration method
inverse prediction method
Opis:
The classical and inverse linear calibration methods based on the regression of y on x and the regression of x on y, were applied to several humidity sensors. The predicted values for given values of the output value of sensors were calculated, and conclusions concerning the accuracy of prediction were drawn.
Zastosowano metodę klasyczną i metodę odwrotną kalibracji liniowej oparte, odpowiednio, na regresji y względem x oraz regresji x względem y do wyznaczenia równania prostej kalibracji dla kilku sensorów wilgotności oferowanych na rynku. Przedstawiono wyniki obliczeń wartości predykowanych wilgotności dla wybranych wartości sygnału wyjściowego sensorów oraz podano wnioski dotyczące dokładności predykcji.
Źródło:
Prace Instytutu Elektrotechniki; 2011, 252; 101-106
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Self-oscillating parametric humidity sensor with frequency output signal
Samooscylacyjny parametrycznyczujnik wilgotności z częstotliwościowym sygnałem wyjściowym
Autorzy:
Osadchuk, Iaroslav O.
Osadchuk, Oleksandr V.
Osadchuk, Vladimir. S.
Krylik, Lyudmila. V.
Powiązania:
https://bibliotekanauki.pl/articles/27315405.pdf
Data publikacji:
2023
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
self-oscillating parametric humidity sensor with frequency output
negative differential resistance
humidity-sensitive resistor
samooscylacyjny parametryczny czujnik wilgotności z wyjściem częstotliwościowym
ujemna rezystancja różnicowa
rezystor wrażliwy na wilgoć
Opis:
A self-oscillating parametric humidity sensor has been developed that implements the principle of "humidity-frequency" conversion into hybrid integrated circuit based on a microelectronic transistor structure with a negative differential resistance, in which the humidity-sensitive element is a resistor of the HR202 type. For the purposes of determining parameters self-oscillating parametric humidity sensor with frequency output a mathematical model has been developed that takes into account the effect of humidity on a sensitive resistive element, which is an integral element of the device. Based on the mathematical model, analytical expressions for the transformation function and the sensitivity equation are obtained. It is shown that the main contribution to the conversion function is made by relative humidity. The computer simulation and experimental studies of a self-oscillating parametric humidity sensor with a frequency output signal contributed to obtaining the main parameters and characteristics, such as the dependence of the generation frequency on changes in relative humidity in the range from 30% to 99%, the change in sensitivity on relative humidity, the dependence of the active and reactive components of the impedance in the frequency range from 50 kHz to 2 GHz; standing wave ratio, change in logarithmic magnitude and spectra of the output signal of a parametric humidity sensor with a frequency output signal in the LTE-800 Downlink frequency range. The obtained electrical characteristics confirm the operability of the developed device. The sensitivity of the developed self-oscillating parametric humidity sensor in the range of relative humidity change from 30% to 99% has a value from 332.8 kHz/% to 130.2 kHz/%.
Opracowano samooscylujący parametryczny czujnik wilgotności realizujący zasadę konwersji „wilgotność-częstotliwość” do hybrydowego układu scalonego opartego na mikroelektronicznej strukturze tranzystorowej o ujemnej rezystancji różnicowej, w której elementem czułym na wilgotność jest rezystor typu HR202 typ. Na potrzeby wyznaczania parametrów samooscylującego parametrycznego czujnika wilgotności z wyjściem częstotliwościowym opracowano model matematyczny uwzględniający wpływ wilgoci na czuły element rezystancyjny, będący integralną częścią urządzenia. Na podstawie modelu matematycznego uzyskuje się wyrażenia analityczne dla funkcji transformacji i równania wrażliwości. Pokazano, że główny udział w funkcji konwersji ma wilgotność względna. Symulacja komputerowa i badania eksperymentalne samooscylującego parametrycznego czujnika wilgotności z wyjściowym sygnałem częstotliwościowym przyczyniły się do uzyskania głównych parametrów i charakterystyk, takich jak zależność częstotliwości generacji od zmian wilgotności względnej w zakresie od 30% do 99%, zmiana czułości na wilgotność względną, zależność składowej czynnej i reaktywnej impedancji w zakresie częstotliwości od 50 kHz do 2 GHz; współczynnika fali stojącej, zmiany wielkości logarytmicznej i widma sygnału wyjściowego parametrycznego czujnika wilgotności przy częstotliwościowym sygnale wyjściowym w zakresie częstotliwości LTE-800 Downlink. Uzyskane charakterystyki elektryczne potwierdzają sprawność opracowanego urządzenia. Czułość opracowanego samooscylującego parametrycznego czujnika wilgotności w zakresie zmian wilgotności względnej od 30% do 99% przyjmuje wartość od 332,8 kHz/% do 130,2 kHz/%.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2023, 13, 1; 42--49
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System do badania wpływu wilgotności na czujniki gazów
System for examination of humidity influence on gas sensors
Autorzy:
Jabłoński, K.
Powiązania:
https://bibliotekanauki.pl/articles/268935.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
czujniki gazów
regulacja wilgotności
wpływ wilgotności
błędy czujników
gas sensors
humidity control
influence of humidity
errors of sensor
Opis:
Czujniki gazów są bardzo istotnym elementem wielu instalacji przemysłowych – nie tylko jako elementy bezpośredniej kontroli i obserwacji procesów chemicznych, ale także jako kluczowy komponent systemów bezpieczeństwa. Istotne jest więc zapewnienie odpowiednich parametrów metrologicznych tego typu sensorów, w tym odporności na działanie czynników zewnętrznych. Jednym z czynników mogących silnie wpływać na pomiary stężenia gazu jest jego wilgotność. Niniejszy artykuł przedstawia projekt i konstrukcję urządzenia pozwalającego na regulację wilgotności mieszanek kalibracyjnych gazów, a także jego testy i przeprowadzone z jego pomocą badania czujników katalitycznych i z absorpcją podczerwieni, dowodzące użyteczności zbudowanego prototypu w roli sprzętu laboratoryjnego.
Gas sensors are significant elements of many plants in industry. They do not only serve as indicators and elements of control loops in chemical processes, but also are the main part of the safety systems. In many situations a gas sensor is the first line of defence against leakage of dangerous substances. Therefore, ensuring its appropriate metrological parameters is crucial. The fact that sensors should not be sensitive to environmental parameters is very important. Unfortunately, influence of air humidity, which can strongly affect measurements, is difficult to measure. This paper proposes a system for preparation of gas mixtures with specific relative humidity. It allows to examine the reaction of gas sensors to changes of vapour concentration in calibration gases. One of assumptions of this project was low cost of manufacturing the system and simple, modular construction. The design, construction and examination of the device are presented. The exemplary tests of catalytic sensors and infrared sensors are also described. The accuracy and practical utility of the system were proved by results of conducted research.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2018, 59; 61-64
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Challenges in Integrating Wireless Sensor Network and Internet of Things for Environmental Monitoring
Autorzy:
Vijayalakshmi, S. R.
Muruganand, S.
Powiązania:
https://bibliotekanauki.pl/articles/1193537.pdf
Data publikacji:
2016
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Environmental monitoring
Internet of Things
Temperature and humidity measurement
Wireless Sensor Network
Opis:
Hardware technology developments and wireless communications enables the development of wireless sensor networks (WSNs). WSN will need to be connected to the Internet due to its variety of applications and their importance. This paper discusses the challenges in integrating WSN and IoT (Internet of Things). The best ways of integrating WSN and IoT for environmental monitoring are analyzed. The sensor node is developed to monitor environmental parameters such as temperature and humidity. The sensor SHT75 to sense the temperature and humidity of the environment, XBeePro to communicate with gateway, LCD to display information are interfaced with MSP430 Microcontroller. The microcontroller is used for processing, controlling and communicating the information. The sensor nodes are deployed to measure the parameter in the target area. The information is communicated to the world of Internet in one of the best integrating ways discussed in the paper.
Źródło:
World Scientific News; 2016, 41; 1-8
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kalibracja spektrofotometryczna modelu sondy odbiciowej do dynamicznego pomiaru wilgotności gleby
Spectrophotometric calibration in a reflection probe model for dynamic soil humidity measurement
Autorzy:
Wojciechowski, T.
Piechnik, L.
Powiązania:
https://bibliotekanauki.pl/articles/290014.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
wilgotność gleby
czujnik
odbicie
spektrofotometria
pomiar dynamiczny
soil humidity
sensor
reflection
spectrophotometry
dynamic measurement
Opis:
Upowszechnienie systemów rolnictwa precyzyjnego ograniczane jest przez brak lub małą dostępność wydajnych dynamicznych metod monitorowania środowiska glebowego. Rolę odegrać może tutaj zastosowanie metody odbiciowej pomiaru wilgotności gleb. W ramach prowadzonych działań opracowano metodykę dynamicznego pomiaru wilgotności gleby metodą odbiciową oraz sformułowano założenia i skonstruowano miernik z komercyjnym czujnikiem odbiciowym. Przeprowadzono badania spektrofotometryczne w zakresie NIR co pozwoliło na określenie długości fal najsilniej skorelowanych z wilgotnością gleb oraz ich porównanie z operacyjną długością fali czujnika optoelektronicznego miernika.
Popularisation of precise agriculture systems is limited by complete lack or low availability of efficient, dynamic methods for soil environment monitoring. Using a reflection method for soil humidity measurement may play a role here. In the scope of carried out works, the researchers developed a methodology for dynamic soil humidity measurement using the reflection method, formulated guidelines and designed a meter with commercial reflection sensor. Spectrophotometric tests in NIR range were carried out, allowing to determine wavelengths most strongly correlated with humidity of soils, and to compare them to an operating wavelength of sensor in an optoelectronic meter.
Źródło:
Inżynieria Rolnicza; 2010, R. 14, nr 2, 2; 285-292
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of Textile Resistive Humidity Sensors Made by Sputtering, Printing and Embroidery Techniques
Tekstylny rezystancyjny czujnik wilgotności wykonany techniką napylania, drukowania i haftowania
Autorzy:
Frydrysiak, Michał
Powiązania:
https://bibliotekanauki.pl/articles/234366.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
textile
sensor
humidity
intelligent material
PVD process
printing process
embroidery
tekstylia
czujnik
wilgotność
materiał inteligentny
proces PVD
proces drukowania
haftowanie
Opis:
This paper presents various constructions of flexible textile humidity resistive sensor prototypes which can be used in textronic clothing applications and can be easily integrated with fabric. They can be also used as sensors applied to sheets in hospitals and nursing homes, as well as in special medical clothing, especially for protecting elderly people. The author describes a method of manufacturing such sensors by three different techniques, such as embroidery, printing and sputtering (PVD). Also presented are electrical properties of the textile sensors under various environmental conditions. The resistance of the sensors was studied in a wide range of humidity, from 30 to 90%, and at temperatures of 30 °C and 40 °C. The author then chose the right type of textile substrate on which the sensors should be made. A microscopic examination of the upper electroconductive layer of the prototype sensors was also conducted. These novel methods of sensor creation for humidity measurement on flexible textile substrates and their comparison could be used for clothing functionalisation.
W artykule przedstawiono różne konstrukcje elastycznych, rezystancyjnych czujników wilgotności, które można wykorzystać w aplikacjach tekstronicznych. Przedstawione sensory cechuje łatwość integracji z wyrobami odzieżowymi. Badane czujniki mogą być stosowane w aplikacjach szpitalnych, domach opieki, a także jako czujniki w specjalnej odzieży medycznej, przeznaczonej w szczególności do ochrony osób starszych. Autor opisał metodę produkcji takich czujników za pomocą trzech różnych technik, takich jak haftowanie, drukowanie i napylanie (PVD). Przedstawił także charakterystyki czujników tekstylnych, zmian rezystancji w funkcji wilgotności, w różnych warunkach otoczenia. Parametry czujników badano w szerokim zakresie wilgotności: 30-90% oraz w temperaturach: 30-40 °C. Autor wybrał dwa rodzaje podłoża tekstylnego, na którym wykonane są czujniki, które według niego będą odpowiednie do zastosowań w tekstronicznych aplikacji odzieżowych. Przedstawił również zdjęcia mikroskopowe warstw elektroprzewodzących prototypowych czujników, badania zmian wilgotności w warunkach laboratoryjnych na stanowisku testowym oraz warstwie pododzieżowej na ochotnikach podczas kontrolowanej próby wysiłkowej.
Źródło:
Fibres & Textiles in Eastern Europe; 2020, 5 (143); 91-96
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Informatyczna obsługa stanowiska laboratoryjnego pomiarów wilgotności gleby
It service of the laboratory stand for measuring soil humidity
Autorzy:
Piechnik, L.
Frieske-Górska, E.
Powiązania:
https://bibliotekanauki.pl/articles/288089.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
program informatyczny
badania laboratoryjne
wilgotność gleby
pomiar w ruchu
czujnik
computer program
laboratory research
soil humidity
measurement in motion
sensor
Opis:
W artykule zaprezentowano rezultaty opracowanego i testowanego programu informatycznego o nazwie "Pomiar wilgotności gleby". Program jest przeznaczony do obsługi sondy z czujnikiem optoelektronicznym w obrotowym kanale glebowym. Wchodzi w skład stanowiska laboratoryjnego, na którym dokonywano pomiarów wilgotności gleby w ruchu. Pomiar taki nazwano pomiarem dynamicznym. Do mierzenia zastosowano czujnik optoelektroniczny, który pracuje metodą odbiciową w zakresie bliskiej podczerwieni (NIR). Zadaniem testowanego programu jest bieżąca rejestracja pomiarów z miernika wartości prądowych oraz przeliczanie ich na wartości wilgotności gleby. Program umożliwia wybór formuły matematycznej (aproksymacji), pozwalającej kalibrację czujnika względem badanego gatunku gleby. Rejestruje i oznacza względem czasu poszczególne serie pomiarowe oraz oblicza wartość średnią. Oprócz obsługi pomiarów dynamicznych program umożliwia rejestracje i pozostałe czynności przy pomiarach statycznych, wykonywanych ręcznie podczas opracowywania formuł kalibracyjnych czujnika względem wybranego gatunku gleby. Program przeszedł pozytywnie funkcjonalny etap testowania oraz etap współpracy z różnym sprzętem informatycznym. W efekcie został wdrożony do praktycznego użytkowania w Instytucie Inżynierii Rolniczej Uniwersytetu Przyrodniczego w Poznaniu.
The paper presents results of the developed and tested computer program named "Soil humidity measurement". The program is intended to work with a meter with an optoelectronic sensor in a rotary soil canal. It is a part of the laboratory test station, which is used to measure the soil humidity in motion. Such measurement was named the dynamical measurement. An optoelectronic sensor was used for measuring. It works with a reflection method, in near infrared range (NIR). The main task of the tested program is on-line recording of measurements from an electrical current meter and conversion of the raw values into soil humidity values. The program allows to choose the mathematical formula (of approximation), allowing to calibrate the sensor, adjusting it to the examined soil type. It records subsequent measurement series, marks them with regard to time and calculates the mean value. Apart from operating the dynamical measurement, the program allows recording and performing other activities during the static measurements, carried out manually during elaboration of calibration formulas for the sensor with regard to the selected type of soil. The program has positively undergone a stage of functional testing and a stage of cooperation with various computer devices. As an effect, it was implemented for a practical use in the Institute of Agricultural Engineering, at Poznan University of Life Sciences.
Źródło:
Inżynieria Rolnicza; 2012, R. 16, nr 4, t. 1, 4, t. 1; 321-329
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies