Tytuł:
Fatigue damage and reliability assessment of cemented hip prosthesis
Autorzy:
Doliński, K.
Powiązania:
https://bibliotekanauki.pl/articles/280275.pdf
Data publikacji:
1999
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
hip prosthesis
fatigue damage
material anisotropy
reliability
Opis:
Continuum damage mechanics model is used in the finite element calculation of fatigue process in a cemented hip prosthesis. The cement mantle is assumed to be subjected to the fatigue damage resulting in evolution of the damage-induced material anisotropy and leading, eventually, to loosening of the prosthesis. Fatigue parameters and loads are assumed to be random variables. The reliability analysis is carried out for a linear appriximation of the limit state function and, eventually, some corrections are presented to improve the fatigue lifetime probability distribution assessment.
Do modelowania procesu zniszczenia zmęczeniowego cementowanej protezy biodrowej zastosowano metodę elementów skończonych oraz kontynualny model mechaniki zniszzenia. Otoczka cementowa tworząca zamocowanie protezy narażona jest na uszkodzenia zmęczeniowe, kyóre powodują powstanie i ewolucję anizotropii materiału oraz prowadzą do obluzowania protezy. Parametry materiałowe charakteryzujące proces zmęczenia oraz obcążenia przyjęto jako zmienne losowe. W analizie niezawodności przyjęto liniową aproksymację warunku granicznego określającego przydatność protezy i zaproponowano pewne modyfikacje pozwalające efektywnie szacować rozkład prawdopodobieństwa czasu życia protezy.
Źródło:
Journal of Theoretical and Applied Mechanics; 1999, 3; 505-518
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Traumatic dislocation of the stem of hip joint uncemented endoprosthesis
Urazowe zwichnięcie wkładki protezy bezcementowej stawu biodrowego
Autorzy:
Poszepczyński, Jan
Andrzejewski, Krzysztof
Grabowski, Radosław
Lesman, Jędrzej
Majewski, Michał
Domżalski, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/2152239.pdf
Data publikacji:
2021-07-16
Wydawca:
Fundacja Edukacji Medycznej, Promocji Zdrowia, Sztuki i Kultury Ars Medica
Tematy:
cementless hip prosthesis
hip prosthesis insert
damage of the hip endoprosthesis
proteza bezcementowa biodra
wkładka protezy biodra
uszkodzenie endoprotezy biodra
Opis:
Traumatic dislocation of the stem of hip joint endoprosthesis is a complication which has not been reported so far in literature. It requires surgical treatment whose delay may result in soft tissue incrustation by metal filaments due to friction of the internal hip joint acetabulum and head of the endoprosthesis. In our center, a woman after low-energy(impact) injury was operated on due to painless shortening of limb length accompanied by subjective sensation of crepitus during joint movements.
Zwichniecie urazowe wkładki endoprotezy stawu biodrowego jest powikłaniem dotychczas nieopisywanym w literaturze. Wymaga natychmiastowego leczenia operacyjnego, którego odroczenie skutkować może inkrustacją tkanek miękkich opiłkami metalu pochodzącymi ze ścierającej się wewnętrznej powierzchni panewki stawu biodrowego i głowy endoprotezy. W naszym ośrodku operowaliśmy kobietę po urazie niskoenergetycznym, która zgłosiła się z powodu bezbolesnego skrócenia kończyny z towarzyszącym subiektywnym odczuciem „skrzypienia” podczas ruchu w stawie.
Źródło:
Polish Journal of Sports Medicine; 2021, 37(2); 95-101
1232-406X
2084-431X
Pojawia się w:
Polish Journal of Sports Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Postural stability and functional disorders in patients with loosened hip prosthesis
Autorzy:
Drzał-Grabiec, Justyna
Truszczyńska-Baszak, Aleksandra
Tarnowski, Adam
Powiązania:
https://bibliotekanauki.pl/articles/306972.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
postural stability
hip prosthesis loosening
balance disorders
stabilność postawy
endoproteza
zaburzenia równowagi
Opis:
The number of primary hip arthroplasties is growing every year. One of the most common long complications is the aseptic loosening of the prosthesis leading to serious complications in patients life, pain and following surgeries. In the literature, there is a lack of studies regarding balance impairment in this group of patients, which is why there was a need to conduct the study in order to find possible falling risk factors and simple functional, diagnostic test. The aim of the study was to assess functional state and static balance disorders in patients admitted to orthopaedic department due to loosened hip prosthesis prior to its replacement or removal. Methods: The study population were 30 patients (15 women and 15 men) admitted to Orthopaedic Department for diagnosis and treatment of loosened hip prosthesis. Patients’ mean age was 71.67 ± 9.21, body height 169.20 ± 8.75 cm, body weight 77.83 ± 12.96 kg. The clinical control group consisted of 30 healthy subjects age-, body height- and weight-matched, without degenerative disorders of lower extremities. Function was assessed with Harris Hip score. The static balance test was conducted in the mornings, in quiet separate room on bi-modular stabilometric platform CQStab2P, registering the movement of centre of foot pressure (COP). Results: Measurements with eyes open and closed showed significant differences in limb loads – the load to the healthy limb was several times greater. Results of tests on the platform with eyes closed showed significantly worse balance in patients group. Their total statokinesiogram path was longer, and their COP sways number was greater. Similarly to the test with eyes open, the load of the healthy limb was much greater. Conclusion: Hip replacement loosening results in significant worsening of balance parameters. Balance assessment could be an additional useful diagnostic tool for hip replacement loosening available for physiotherapists.
Źródło:
Acta of Bioengineering and Biomechanics; 2020, 22, 1; 41-46
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical assessment of a hip joint stem model made of a PEEK/carbon fibre composite under compression loading
Autorzy:
Dworak, M.
Błażewicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/307412.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
staw biodrowy
proteza
włókna węglowe
biomateriały
hip prosthesis
carbon fibres
PEEK matrix
stress shielding
composite stem
Opis:
Purpose: The aim of the work was to manufacture a composite stem model consisting of carbon fibres (CF) and polyether ether ketone (PEEK) and to perform the surface strain and stress distributions in the stem-femoral bone model under compression loading. Methods: Composite stems differing in elasticity were prepared. Three types of composite stems having different arrangements of carbon fibre reinforcements (carbon fibre roving, carbon fibre sleeves and their combinations) in the polymer matrix were made. The stems were cementless fixed in the femoral bone model channel or with the use of the polymer bone cement (PMMA). Mechanical behaviour of composite stems under compression loading was compared with a metallic stem by strain gauge measurements at different parts of stem/bone model systems. Results: The values of stresses in the proximal part of the bone model for cemented and cementless fixations of the composite stem in the femoral bone channel were higher than those noted for the metallic stem. The increase in proximal bone stress was almost similar for both types of fixation of composite stems, i.e., cemented and cementless fixed stems. Conclusions: The optimal range of mechanical stiffness, strengths and work up to fracture was obtained for composite stem made of carbon fibre sleeves and carbon fibres in the form of roving. Depending on the elasticity of the composite stem model, an increase in the stress in the proximal part of femoral bone model of up to 40% was achieved in comparison with the metallic stem.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 2; 71-79
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania doświadczalne zużycia główki endoprotezy stawu biodrowego ze stopu kobalt-chrom oraz z tlenku aluminium
An experimental study of the nano-scratch behavior of a femoral head
Autorzy:
Leshchynsky, V.
Soifer, Y.
Wierusz-Kozłowska, M.
Markuszewski, J.
Woźniak, W.
Bielousova, O.
Weinert, H.
Powiązania:
https://bibliotekanauki.pl/articles/211696.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Obróbki Plastycznej
Tematy:
endoprotezy stawu biodrowego
mechanizm zużycia
topografia powierzchni
mikroskopia sił atomowych
hip replacement prosthesis
wear mechanism
surface topography
atomic force microscopy (AFM)
Opis:
Artykuł dotyczy badań doświadczalnych zużycia główek endoprotez stawu biodrowego wykonanych w ramach zakresu badań na symulatorach ruchu endoprotez kolanowych i biodrowych prowadzonych w Instytucie Obróbki Plastycznej w Poznaniu we współpracy z Katedrą i kliniką Ortopedii i Traumatologii Uniwersytetu Medycznego w Poznaniu z udziałem Uniwersytetu Tel Aviv. Zużycie wciąż jest znaczącym czynnikiem wpływającym na uszkodzenia implantów. Badania in-vivo wykazują, że na większe zużycie wpływa chropowatość powierzchni protez główki kości udowej. W przypadku endoprotezy stawu biodrowego z wkładką z polietylenu, zuzycie bardziej miękkiego polietylenu jest powodowane chropowatością powierzchni główki, która niszczy powierzchnię polietylenu i odłącza jego cząstki. W artykule opisano wyniki badań morfologii powierzchni główki implantu po eksploatacji oraz wyniki modelowania procesu uszkodzenia tej powierzchni poprzez nanoindentację i nanozarysowania celem lepszego zrozumienia mechanizmu procesu zużywania się endoprotezy stawu biodrowego. Badania przeprowadzono metodą mikroskopii sił atomowych (AFM). Badania wykazały poważne uszkodzenia powierzchni kobaltowo – chromowej i ceramicznej główki. Stwierdzono, ze zarysowania na główce kości udowej w nanoskali powstają w wyniku formowania się bryłowatych wypukłości o niskiej gęstości, które mogą działać jako inicjatory powstawania produktów zużycia, co wydaje się być jedną z głównych przyczyn zużycia polietylenu w pierwszym etapie eksploatacji implantu stawu biodrowego.
Bearing wear continues to be a contributing factor to implant failure. Prosthetic femoral heads roughen in vivo which leads to increased wear. For a femoral head articulating against polyethylene, wear of softer polyethylene is known to be caused by the hard asperities on the surface of the femoral head, that destroy polyethylene surface and detach polyethylene particles. In the present work in order to better understand the mechanism of femoral head prosthesis wear process we studied the femoral head surface morphology after implant articulation and modeled the damage of the femoral head surface by nanoindentation and nanoscratching with Atomic Force Microscopy Technique. The Atomic Force Microscopy examination of scratching process revealed a severe surface damage cobalt-chrome and alumina femoral head surface. The nano-scale scratch of femoral heads is shown to result in formation of lumpy protuberances with low density which can act as a precursor for wear particles that seems to be one of the main reasons of polyethylene wear at least at the first (running) stage of the HIP implant articulation.
Źródło:
Obróbka Plastyczna Metali; 2009, 20, 4; 30-42
0867-2628
Pojawia się w:
Obróbka Plastyczna Metali
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Strenghth analysis of hip joint replacement revision implant
Autorzy:
Skowronek, Paweł
Twardoch, Krzysztof
Skawiński, Piotr
Żołnierz, Marcel
Powiązania:
https://bibliotekanauki.pl/articles/280287.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
implant
implant strength
prosthesis
hip joint
material loss
Opis:
The subject of the article is the evaluation of the strength of revision implants made of titanium or tantalum alloy, used during bone reconstruction of a hip joint while potentially using additional stabilizing screws, necessary due to significant bone loss. The article provides a preliminary strength analysis of implants, indispensable for further evaluation of strength limitations due to the risk of implant damage depending on the structure and number of additional screw holes. In the human locomotor system, the hip joint is the joint with the most load, hence the main problem is to establish an adequate load model which ought to be assumed for the needs of implant strength analysis. It is found necessary to perform a short, analytical review of the existing hip joint load models from the point of view of choosing the proper one, considering evaluation of implant strength by means of numerical studies using FEM. Differences in the implant load distribution depending on the used material are shown.
Źródło:
Journal of Theoretical and Applied Mechanics; 2019, 57, 1; 235-248
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Orthopedic diagnostics with ensembles of learning systems
Autorzy:
Szarek, A.
Korytkowski, M.
Rutkowski, L.
Scherer, R.
Szyprowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/99251.pdf
Data publikacji:
2012
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
hip joint
prosthesis
assessing orthopaedic data
classifier
staw biodrowy
proteza
ocena danych ortopedycznych
klasyfikator
Źródło:
Aktualne Problemy Biomechaniki; 2012, 6; 141-146
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zjawiska biomineralogiczne w endoprotezach stawu biodrowego
Biomineralogical phenomenon in hip joint endoprostheses
Autorzy:
Pawlikowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/344072.pdf
Data publikacji:
2018
Wydawca:
nakł. Maciej Pawlikowski
Tematy:
staw biodrowy
endoprotezy
elementy metalowe protezy
hip joint
endoprostheses
metal elements of prosthesis
acetabular
Opis:
Wykonano badania elementów endoprotez stawu biodrowego pod kątem starzenia się materiałów, rozpoznania struktur stosowanych metali oraz cementów służących do fiksacji endoprotez. Badaniom poddano także „zużyte" elementy endoprotez po różnych okresach ich funkcjonowania. Stwierdzono, że starzenie się polimerów prowadzi to ich spękania przez co skraca się czas prawidłowego funkcjonowania panewek i całych sztucznych stawów. W „pracujących” elementach metalowych (głowy endoprotez) zaobserwowano w stali wtrącenia mikro żużelków, które po wykruszeniu się ze stali pod czas stawu biodrowego niszczą gładź powierzchni głowy endoptotezy oraz wewnętrzna powierzchnię panewki. Długotrwałe obciążenie panewek prowadzi do zmiany struktury atomowej polipropylenu z którego wykonane są panewki. To pociąga za sobą szybsze niszczenie obciążanej panewki. Badane, dwuskładnikowe cementy fiksujące endoprotezę zawierały banieczki powietrza, co jest efektem mieszania składników. Ich obecność osłabia stabilizacje endoprotezy przyspieszając konieczność jej wymiany.
Tests were performed on elements of hip joint endoprostheses regarding aging of the materials, structures of the metals as well as the cements used to fix the implant to the bone.“Worn out” elements of endoprostheses after different periods of functioning were also studied It was determined that aging of the polymers leads to their cracking, which shortens the time of proper functioning of the acetabula and the whole artificial joints. In the “working” metal elements (femoral heads) creation of micro slag bits in the steel was observed. Those bits break out from the steel during the functioning of the hip joint, damaging the surface finishing of the head of the implant and the inner surface of the acetabulum. Long-term load on the acetabula leads to changes in the atomic structure of the polypropylene that they are built of. That causes the acetabula to wear out faster. Two-component fixing cements that were tested contained air bubbles as a result of mixing the components. Their presence weakens the endoprostheses stabilization, accelerating the necessity to replace it.
Źródło:
Auxiliary Sciences in Archaeology, Preservation of Relics and Environmental Engineering; 2018, 25; 71-88
1689-6742
Pojawia się w:
Auxiliary Sciences in Archaeology, Preservation of Relics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tribologia eliptycznych endoprotez stawu biodrowego
Tribology of elliptical hip joint prosthesis
Autorzy:
Wierzcholski, K.
Powiązania:
https://bibliotekanauki.pl/articles/188333.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
eliptyczna głowa kostna
eliptyczna endoproteza połowicza stawu biodrowego
konstrukcje
tribologia współpracujących powierzchni
eksploatacja
elliptical bone head
elliptical half prosthesis for hip joint
constructions
tribology of cooperating surfaces
exploitation
Opis:
Współczesne badania eksperymentalne wyposażone w mikroskopy najnowszej generacji potwierdzają, że głowy stawu biodrowego człowieka są z natury nie sferyczne lecz eliptyczne. Kształt elipsoidy jest formowany zazwyczaj cieńszą lub grubszą warstewką chrząstki stawowej na powierzchni głowy. Badania laboratoryjne potwierdzają, że warstewka chrząstki stawowej jest najszersza na górnym biegunie a najcieńsza na równiku. Przez górny biegun eliptycznej głowy a zarazem wzdłuż najdłuższej półosi elipsoidy przebiega oś szyjki uda. Ze względu na minimalną wartość oporów tarcia najkorzystniejszy jest obrót głowy kostnej biodra po kierunku równoleżnika, czyli po kierunku równika, ponieważ bryła elipsoidy kostnej jest obrotowa. Inne kierunki obrotu są również możliwe ale odznaczają się między innymi zwiększonymi oporami tarcia spowodowanymi minimalną różnicą długości półosi elipsy w przekrojowej płaszczyźnie obrotu elipsoidalnej głowy kostnej. Praca niniejsza przedstawia niektóre aspekty konstrukcji i eksploatacji w zakresie współpracy powierzchni eliptycznych endoprotezy stawu biodrowego, jak również omówione zostaną korzyści wynikające ze współpracy połowiczej endoprotezy eliptycznej z eliptyczną głową kostną. W przypadku zniszczonej panewki wszczepienie eliptycznej endoprotezy połowiczej panewki ułatwia współpracę z eliptyczną głową kostną.
The presented paper shows and gives the reasons for the contemporary failures occurring in alloplastic (human hip joint prosthesis) performances such as the locally boosted friction forces and stresses and breaks of the prosthesis pin. This paper was motivated by the application of a spherical rather than elliptical head of a prosthesis that is not sufficiently adapted to the elliptical geometry of the natural acetabulum surfaces. The negative effects are enlarged by the stochastic standard effects occurring during the prosthesis exploitation. Numerous contemporary studies and experimental measurements regarding the human hip joints indicate that the femoral head is in fact naturally elliptical. Therefore, the elliptical head in hip prosthesis must be better adapted to the elliptical surface geometry of the natural acetabulum in comparison with the spherical head. Half prostheses of hip joints are applied when joint acetabulum cartilage is well maintained. In the half prosthesis, the head is welded to the spindle or seated to the pin. When acetabulum cartilage is worn (used), a complete prosthesis is implanted. The elliptical femoral prosthesis was designed to solve the problem of the relationship between the femoral prosthesis head and the anatomical acetabulum and to minimize the various incidence of wear protrusion and pain effects. Performed clinical tests indicate that elliptical prosthesis heads have the most advanced technological shapes, because they are based on the anatomy and biomechanics features of the natural human hip joint. The biomechanics of an elliptical head femoral prosthesis can be taken as the appropriate shape in respect to the treatment of medical fractures of the neck of the femur. Taking into account the hydrodynamic theory of the lubrication of cooperating surfaces, we must find pressure distributions, friction forces, friction coefficients, and wear. To prepare these calculations, we first determine and calculate the fields of the regions of lubrication on the internal surface lying on the elliptical femoral prosthesis (i.e. acetabulum) and on the external elliptical surface of the artificial bone or femoral head.
Źródło:
Tribologia; 2014, 2; 167-174
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies