Tytuł:
Applications of recombination chambers in the dosimetry of high energy radiation fields
Autorzy:
Zielczyński, M.
Golnik, M.
Gryziński, M. A.
Powiązania:
https://bibliotekanauki.pl/articles/147680.pdf
Data publikacji:
2008
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
initial recombination
ionization chambers
high energy radiation
Opis:
High energy radiation fields exist in space, in the atmosphere at the height of commercial flights and in the vicinity of some accelerators. The characteristic features of these fields are their complex composition and broad energy spectrum. Estimation of the absorbed dose in such fields cannot be performed by consideration of the doses from all the radiation field components. The physically possible way to solve the problem is to determine the operational quantity-ambient dose equivalent H* (10). The radiation detector used for the determination of H* (10) should be large enough in order to simulate the ICRU sphere. Its effective wall thickness should not be very different than 10 mm of tissue. The REM-2 type recombination chamber is an example of such a detector. The review paper presents specific challenges of high energy radiation field dosimetry and discusses a number of examples of measurements at high energy accelerators, including some international intercomparisons. We show that the REM-2 chamber is especially suitable for radiation monitoring in the vicinity of high energy accelerators.
Źródło:
Nukleonika; 2008, 53, suppl. 1; 45-52
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Specific heat of selected graphites used in calorimetry of electron beam and its influence on the accuracy of measurement of large dose
Autorzy:
Panta, P.
Głuszewski, W.
Powiązania:
https://bibliotekanauki.pl/articles/147858.pdf
Data publikacji:
2005
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radiation processing
radiation sterilization
electron beam (EB)
high dose calorimetry
calibration
electron energy
Opis:
Calorimetry is applicable to both absolute calibration of routine dosimeters and absolute measurements of electron beam (EB) intensity (for industrial radiation processing). Advantages of graphite as the absorbing calorimetric material are a good heat capacity and negligible heat defect of this material. Knowledge of the specific heat capacities of the calorimetric core materials is fundamental in making absolute dose measurements. Two kinds of high-purity graphite used in calorimeters were analysed, i.e. Union Carbide grade AGOT and nuclear grade graphite [10]. There are some differences of specific heat of these graphites, up to 2% , which influence dosimetric response of calorimeters made of them.
Źródło:
Nukleonika; 2005, 50,suppl.2; 55-57
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies