Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "heating network" wg kryterium: Temat


Wyświetlanie 1-12 z 12
Tytuł:
Low temperature district heating using waste heat from biogas plant
Autorzy:
Cenian, A.
Noch, T.
Powiązania:
https://bibliotekanauki.pl/articles/1190191.pdf
Data publikacji:
2019
Wydawca:
Gdańska Szkoła Wyższa
Tematy:
low-temperature district-heating network
biogas installation
co-generation
energy efficiency
Opis:
A biogas plant can be a source of waste-heat flows with different thermal parameters. Application of such flows in local, low-temperature district-heating networks is a very attractive option for highly efficient, energetically and economically, co-generation systems applying biogas as the primary energy source.
Źródło:
Eco-Energetics: technologies, environment, law and economy; 2019, 2; 19--28
2657-5922
2657-7674
Pojawia się w:
Eco-Energetics: technologies, environment, law and economy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structural analysis Kazakhstan cities heating networks
Analiza strukturalna sieci ciepłowniczych miast Kazachstanu
Autorzy:
Akbassov, A.
Sulemenov, B.
Mukhanov, B.
Gromaszek, K.
Powiązania:
https://bibliotekanauki.pl/articles/408822.pdf
Data publikacji:
2012
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
sieć ciepłownicza
modelowanie
analiza strukturalna
graf
heating network
modeling
structural analysis
graph model
Opis:
In this paper the structural analysis of Kazakhstan cities heating networks has been presented.
W tym artykule została przeprowadzona analiza strukturalna sieci ciepłowniczych miast Kazachstanu.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2012, 1; 39-41
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Possibility of using adsorption refrigeration unit in district heating network
Autorzy:
Grzebielec, A.
Rusowicz, A.
Jaworski, M.
Laskowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/240811.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
refrigeration
adsorption refrigeration
air conditioning
district heating network
chłodzenie
absorpcja
klimatyzacja
sieć ciepłownicza
Opis:
Adsorption refrigeration systems are able to work with heat sources of temperature starting with 50°C. The aim of the article is to determine whether in terms of technical and economic issues adsorption refrigeration equipment can work as elements that produce cold using hot water from the district heating network. For this purpose, examined was the work of the adsorption air conditioning equipment cooperating with drycooler, and the opportunities offered by the district heating network in Warsaw during the summer. It turns out that the efficiency of the adsorption device from the economic perspective is not sufficient for production of cold even during the transitional period. The main problem is not the low temperature of the water supply, but the large difference between the coefficients of performance, COPs, of adsorption device and a traditional compressor air conditioning unit. When outside air temperature is 25°C, the COP of the compressor type reaches a value of 4.49, whereas that of the adsorption device in the same conditions is 0.14. The ratio of the COPs is 32. At the same time ratio between the price of 1 kWh of electric power and 1 kWh of heat is only 2.85. Adsorption refrigeration equipment to be able to compete with compressor devices, should feature COPads efficiency to be greater than 1.52. At such a low driving temperature and even changing the drycooler into the evaporative cooler it is not currently possible to achieve.
Źródło:
Archives of Thermodynamics; 2015, 36, 3; 15-24
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Smart district heating networks in the era of energy transformation
Autorzy:
Wrzalik, Aleksandra
Powiązania:
https://bibliotekanauki.pl/articles/23944754.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
district heating
smart heating network
renewable energy sources
intelligent control
ciepłownictwo miejskie
inteligentna sieć ciepłownicza
odnawialne źródła energii
inteligentne sterowanie
Opis:
District heating, which accounts for half of the EU's energy consumption, still relies heavily on fossil fuels. This causes emissions of dust and greenhouse gases and into the atmosphere and leads to negative climate changes. For this reason, European Union countries have been implementing a climate and energy policy for many years, which in the area of heating is aimed at making it more efficient and sustainable. This requires the introduction of low-carbon technologies and the reduction of fossil fuel consumption by increasing the share of renewable energy sources. Modern, efficient and smart heating systems should guarantee reliable heat supply while reducing the environmental impact. The article discusses the direction of change and development of district heating systems through the introduction of innovative technologies. The new generations of 4GDH and 5 GDH district heating systems are described and the benefits of their use are indicated. The concept of smart district heating networks, their structure and the advantages of their implementation are discussed. The possibilities of creating smart energy systems using renewable energy sources and heat storage technologies were also indicated. The activities of Polish district heating companies in the introduction of smart heat networks are presented, based on research conducted.
Źródło:
System Safety : Human - Technical Facility - Environment; 2022, 4, 1; 58-66
2657-5450
Pojawia się w:
System Safety : Human - Technical Facility - Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Long-term Analysis of the Operation of the Urban Heating Network Including Aspects of Environmental Protection
Długoterminowa analiza eksploatacji miejskiej sieci ciepłowniczej z uwzględnieniem aspektów ochrony środowiska
Autorzy:
Muc, Adam
Szeleziński, Adam
Lizakowski, Piotr
Noch, Tadeusz
Powiązania:
https://bibliotekanauki.pl/articles/1811763.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
heating network
network monitoring
heat network malfunctions
environmental protection
pre-insulated networks
sieć ciepłownicza
monitoring sieci
awarie sieci ciepłowniczych
ochrona środowiska
sieci preizolowane
Opis:
The article presents methods for the location of leakages in heating pipelines. The advantages and disadvantages of each of the described methods are presented. The exploitation and modernization of the actual heating network in the city of up to 30,000 inhabitants over the space of 10 years have been characterized. The examined heating network was analyzed for the degree and categories of malfunctions occurring in the examined time space in the network and impact on the natural environment was determined. The article also examines the impact of various factors, such as the amount of make-up water, the amount of heat required to heat the supplementary carrier, the total cost of heat to replenish the carrier, networks total disruption and the amount of water exchange in the system and its impact on the natural environment. At the same time, an assessment of the impact of the modernization of the heating network combined with its munition to reduce the impact of these factors on environmental protection was made.
W artykule przedstawiono metody lokalizacji nieszczelności rurociągów ciepłowniczych. Przedstawiono wady i zalety każdej z opisanych metod. Scharakteryzowano eksploatację i modernizację rzeczywistej sieci ciepłowniczej w mieście do 30 tysięcy mieszkańców na przestrzeni 10 lat. W badanej sieci ciepłowniczej przeanalizowano stopień i kategorie awarii występujących w badanej przestrzeni czasu w sieci oraz określono ich wpływ na środowisko naturalne. W artykule zbadano również oddziaływanie rożnych czynników, takich jak: ilość wody uzupełniającej, ilość ciepła do podgrzania nośnika na uzupełnienie, koszt łączny ciepła przeznaczony do uzupełnienia nośnika, zład łączny sieci oraz ilość wymian wody w systemie i jej wpływ na środowisko naturalne. Równolegle, podjęto ocenę wpływu modernizacji sieci ciepłowniczej, połączonej z jej uzbrojeniem, na zmniejszenie oddziaływania wymienionych czynników na ochronę środowiska.
Źródło:
Rocznik Ochrona Środowiska; 2019, Tom 21, cz. 1; 330-342
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Narzędzia informatyczne do zarządzania i optymalizacji pracy systemu ciepłowniczego
Information implements in managing and optimizing district heating network
Autorzy:
Rak, Aleksandra
Powiązania:
https://bibliotekanauki.pl/articles/589014.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Ekonomiczny w Katowicach
Tematy:
Monitoring
Narzędzia informatyczne
Optymalizacja i modelowanie sieci ciepłowniczej
Systemy ciepłownicze
Heating systems
Information technology tools
Optimizing and modeling a district heating network
Opis:
Warunki eksploatacji miejskich sieci ciepłowniczych muszą sprostać wielu wyzwaniom, w tym restrykcyjnym wymaganiom UE, dotyczącym polityki zrównoważonego rozwoju, ograniczenia emisji zanieczyszczeń, zmniejszenia zużycia energii oraz poprawy efektywności energetycznej w całym systemie ciepłowniczym. Obecnie wiele przedsiębiorstw energetycznych wytwarzających lub przesyłających ciepło wdraża technologie informatyczne i opracowuje strategie operacyjne w celu zoptymalizowania kosztów i poprawy ogólnej pracy sieci. W artykule omówiono systemy i narzędzia informatyczne, w tym dwa nowoczesne programy dostępne na rynku europejskim, będące zaawansowanymi narzędziami do analizowania pracy sieci ciepłowniczych w zakresie bieżącej eksploatacji oraz planowania ich rozbudowy. Programy umożliwiają dokonanie wszelkich inżynierskich obliczeń hydraulicznych i termodynamicznych, zarówno statycznych, jak i dynamicznych.
The exploitation of district heating networks has to cope with many challenges, such as EU demands involving balanced development policy, carbon dioxide emission limits, energy usage reduction and increasing the energetic efficiency of the heating systems. Many energetic companies at present apply information technology and work on cost optimization strategies and improving their heating systems in general. The article covers the usage of different methods and technologies, including two modern computer systems available on the European market which are advanced devices for analyzing heating system exploitation and for planning its development. The computer programs enables hydraulic and thermodynamic calculation, both static and dynamic.
Źródło:
Studia Ekonomiczne; 2016, 308; 115-127
2083-8611
Pojawia się w:
Studia Ekonomiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda trygonometryczna w pomiarach przemieszczeń mostowej przeprawy miejskiej sieci ciepłowniczej
Trigonometric method in displacement surveys of bridge crossing of the urban heating network
Autorzy:
Cybulski, P.
Wyczałek, I.
Powiązania:
https://bibliotekanauki.pl/articles/383531.pdf
Data publikacji:
2018
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
obiekty mostowe
sieć ciepłownicza
konstrukcja nośna
czynniki eksploatacyjne
czynniki atmosferyczne
pomiary geodezyjne
przeprawy mostowe
bridge object
heating network
supporting structure
operational factors
atmospheric factors
geodetic measurements
bridge crossing
Opis:
Diagnostyka obiektów mostowych ma szczególne znaczenie w odniesieniu do przepraw sieci ciepłowniczej, gdzie stabilność konstrukcji nośnej jest głównym gwarantem bezawaryjnego transferu energii cieplnej przez rzekę. Jednym ze szczególnie wrażliwych elementów tego typu mostów jest nierównomierne przemieszczanie się ich elementów składowych spowodowane czynnikami eksploatacyjnymi i atmosferycznymi. W tym zakresie nieocenione wydają się okresowe pomiary geodezyjne przepraw mostowych dające obraz występujących na nich przemieszczeń. Artykuł obejmuje ocenę tachimetrycznych pomiarów przemieszczeń ciepłowniczej przeprawy mostowej, w oparciu o kilka serii obserwacji mostu wiszącego, zlokalizowanego w północno-wschodniej części Poznania. Pomiary poprzedzono wstępną analizą dokładności. Do oceny odkształceń mostu przyjęto 64 punkty kontrolowane, zlokalizowane parami na konstrukcji i odciągach oraz 3 punkty odniesienia znajdujące się poza badanym obiektem. Wykonano trzy serie pomiarowe i każdą z nich porównano z pomiarem odniesienia z 2010 roku. Wyniki analizy przedstawiono w postaci tabelarycznej, jako przemieszczenia poziome i pionowe od stanu bazowego. Wykazano, że uzyskane parametry dokładnościowe pozwalają na wiarygodną ocenę stanu geometrycznego tej klasy konstrukcji.
Diagnostics of bridge structures are of particular importance with regard to heating network crossings, where the stability of the supporting structure is the main guarantor of failure-free thermal energy transfer across the river. One of the particularly sensitive elements of this type of bridges is the uneven movement of their components caused by operational and atmospheric factors. In this respect, periodic trigonometric surveys of bridges seem to be invaluable giving an image of the displacements occurring on them. The article focuses on the estimation of displacement surveys of the heating bridge crossing, based on several series of observations of the suspension bridge, located in the north-eastern part of Poznań. The measurements were preceded by a preliminary analysis of accuracy. To assess the deformation of the bridge, 64 natural controlled points were selected, located on both sides of the structure and supporting ropes, and 3 reference points located outside the tested object. Three measuring series were made and each was compared with the reference measurement from 2010. The results of the analysis are presented in tabular form as horizontal and vertical displacements from the base state. It was shown that the obtained accuracy parameters allow for a reliable assessment of the geometrical state of this class of construction.
Źródło:
Archiwum Instytutu Inżynierii Lądowej; 2018, 27; 61-74
1897-4007
Pojawia się w:
Archiwum Instytutu Inżynierii Lądowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of neural networks for control of district heating
Wykorzystanie sieci neuronowych do regulacji w ciepłownictwie
Autorzy:
Chmielnicki, W. J.
Powiązania:
https://bibliotekanauki.pl/articles/230702.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
sieć neuronowa
regulacja
ciepłownictwo
zastosowanie
neural network
control
district heating
application
Opis:
The annual usage of heat for the demand of heating systems in municipal sector has been estimated as about 650PJ. It is mostly addressed for the demand of central heating systems and hot water consumption. The mode of adopted solutions concerning regulation and control, as well as energy management system, essentially influence its consumption. In the case of residential buildings, the costs of energy constitute the greatest share related to the total cost of building maintenance. Providing buildings with modern digital systems for control and regulation of heating installations is a basic condition enabling their rational usage. In currently employed solutions, algorithms PI or PID are usually applied. However, due to the non-linear properties of heating control systems, they do not secure proper quality. The sequences are often unstable and major control deviations occur. The application of neural networks is an alternative solution to those presently employed. They are especially recommended for adaptive control of non-stationary systems. Such cases occur in heating objects since they demonstrate non-linear properties with a great range of variability of parameters; this especially refers to district heating equipped with flux-through heat exchangers. A compile model of heating system control aided by neural networks is presented. The results of the investigation clearly prove the usefulness of such solutions, cause the quality of control is much better than that one applied in traditional systems. Presently, works on the implementation of the proposed solutions are under way.
Roczne zużycie ciepła na potrzeby ciepłownicze w Polsce w sektorze komunalno-bytowym, szacowane jest na około 650PJ. W znacznej części przeznaczone ono jest na potrzeby centralnego ogrzewania i ciepłej wody użytkowej. Instotny wpły na jego zużycie ma rodzaj przyjętych rozwiązań dotyczących regulacji i sterowania oraz systemów zarządzania energią. W przypadku budynków mieszkalnych koszty energii stanowią największy udział w stosunku do całkowitych kosztów związanych z eksploatacją budynku. Podstawowym warunkiem umożliwiającym racjonalne jej zużycie jest wyposażenie budynku w nowoczesne cyfrowe systemy do regulacji i sterowania instalacji ciepłowniczych. W stosowanych obecnie rozwiązaniach wykorzystuje się zwykle algorytmy Pl lub PlD. Jednak ze względu na nieliniowe właściwości ciepłowniczych obiektów regulacji, nie zapewniają one odpowiedniej jakości. Często przebiegi mają charakter niestabilny i dochodzi do znacznych odchyłek regulacji. Alternatywą do stosowanych obecnie rozwiązań jest wykorzystanie sieci neuronowych. Są one szczególnie zalecane do sterowania adaptacyjnego układów niestacjonarnych. Takie przypadki występują w obiektach cieplnych, gdyż mają one właściwości nieliniowe o bardzo dużym zakresie zmienności parametrów, dotyczy to zwłaszcza węzłów ciepłowniczych wyposażonych w przepływowe wymienniki ciepła. W pracy przedstawiono opracowany model sterowania węzłów ciepłowniczych za pomocą sieci neuronowych. Wyniki badań wyraźnie wskazują na celowość takich rozwiązań, gdyż jakość regulacji jest znacznie lepsza aniżeli w przypadku stosowania układów tradycyjnych. Aktualnie trwają prace nad wdrożeniem zaproponowanych rozwiązań.
Źródło:
Archives of Civil Engineering; 2010, 56, 3; 219-238
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected aspects of hydraulic issues in heating systems
Autorzy:
Rak, A.
Powiązania:
https://bibliotekanauki.pl/articles/112035.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
heating systems
issues of heat supply
structures of the heating
network
hydraulic issues
system ogrzewania
zaopatrzenie w ciepło
sieci ciepłownicze
Opis:
Rational and efficient use of thermal energy in recent years has resulted in significant changes in the heating system as well as technological progress. In order to design a heating system properly and exploit it correctly, an in-depth understanding of the hydraulic issues is necessary. Application of automatic control system in various sectors of heating network has resulted in a more dynamic and efficient work of the whole system. For proper operation of a thermal system it is also necessary to compile a correct heat balance and a regulation graph that allows to determine the optimal mass and parameters of heat medium. The article discusses the problems of supplying heat process, types of thermal systems and selected problems of hydraulic issues that occur in the heating networks.
Źródło:
Production Engineering Archives; 2017, 14; 27-32
2353-5156
2353-7779
Pojawia się w:
Production Engineering Archives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagospodarowanie schłodzonych i odsolonych wód termalnych w Podhalańskiej Sieci Ciepłowniczej
Cooled and desalinated thermal water utilization in the Podhale Heating System
Autorzy:
Tomaszewska, B.
Pająk, L.
Powiązania:
https://bibliotekanauki.pl/articles/216572.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
odsalanie wody
ultrafiltracja
odwrócona osmoza
geotermia
straty wody sieciowej
ciepłownictwo
water desalination
ultrafiltration
reverse osmosis
geothermics
network water losses
district heating
Opis:
Woda obiegowa w instalacjach ciepłowniczych musi posiadać odpowiednie parametry fizykochemiczne, uzależnione od wymagań technicznych producentów urządzeń, przez które przepływa. Nie powinna powodować powstawania kamienia kotłowego, pienić się oraz korozyjnie oddziaływać na elementy instalacji. W pracy przedstawiono badania dotyczące oceny możliwości wykorzystania odpadowych wód termalnych w celu uzupełnienia ubytków wody sieciowej w największym polskim geotermalnym systemie ciepłowniczym zlokalizowanym w obrębie niecki podhalańskiej. Obszar ten cechuje się dużymi zasobami wód termalnych, a jednocześnie deficytem wód zwykłych. Odpadowe wody termalne ze względu na wykazywane parametry fizykochemiczne mogą być wykorzystane w systemie dopiero po uzdatnieniu. Podczas badań zagospodarowana i uzdatniana była jedynie część całkowitego strumienia wody geotermalnej (do 5 m3/h), odpowiadająca mniej więcej zapotrzebowaniu systemu ciepłowniczego na świeżą uzdatnioną wodę obiegową (ok. 550 m3/miesiąc). Ubytki wody sieciowej wynikają z nieszczelności sieci, prowadzenia remontów, modernizacji lub obsługi sieci. Oczyszczanie przeprowadzone zostało z wykorzystaniem procesów membranowych w zintegrowanym systemie złożonym z ultrafiltracji (UF) i dwóch niezależnych stopni odwróconej osmozy (RO-1 i RO-2) połączonych szeregowo. Uzdatnianie prowadzone było przy częściowym wykorzystaniu artezyjskiego ciśnienia złożowego, co pozwoliło zredukować moc pomp obiegowych eliminując zużycie energii o około 0,7–0,9 kW. Dzięki podwyższonej temperaturze wody uzdatnionej zredukowana została moc cieplna o około 30 kW oraz efektywniej prowadzone były procesy oczyszczania i odgazowania wody. Uzyskano redukcję: zawartości żelaza ze stężenia około 4 do 0,013 g/m3, twardości ogólnej z 13,5 val/m3 do <0,02 val/m3, zasadowości z 4,45 val/m3 do <0,01 val/m3, fosforanów z 0,03 do <0,006 g/m3, uzyskując spełnienie wymagań określonych w normach, co po korekcie pH i odgazowaniu pozwala wykorzystać uzdatnione wody geotermalne dla uzupełnienia ubytków wody sieciowej w systemie ciepłowniczym. Polska Norma PN-85/C-04601 nie specyfikuje wymagań w zakresie dopuszczalnego stężenia m.in. chlorków i siarczanów w wodzie obiegowej, a więc anionów wpływających na korozyjność wody, głównie wżerową. Jony te tworzą rozpuszczalne związki z metalami, utrudniając powstawanie i wytrącanie tlenków metali. Zastosowanie przedstawionej technologii membranowej w odsalaniu wód termalnych pozwoliło na uzyskanie wysokiego stopnia retencji. Wynosi on dla chlorków 97% po RO-1 i 99% po RO-2, natomiast dla siarczanów 99% już po RO-1.
Distribution water that circulates in heating installations must meet certain parameters depending on the technical requirements set by the manufacturers of the equipment through which it flows. It should not cause scaling of boilers, should not corrode parts of the installation and should not foam. This paper examines the proposition the used of geothermal water to replenish network water losses in the largest Polish geothermal heating system located within the Podhale Basin reservoir. The area in question has considerable geothermal water resources while at the same time exhibiting a fresh water deficit. Only part of the total volume of geothermal water (up to 5 m3/h) was used and treated; this is roughly equivalent to the district heating system demand for treated fresh distribution water (ca. 550 m3/month). The treatment uses membrane processes within the framework of a integrated arrangement including ultrafiltration (UF) and two independent reverse osmosis stages (RO-1 and RO-2) connected in series. Artesian pressure was used to a certain extent during the treatment, which makes it possible to reduce the power required for the distribution pump, decreasing electrical power consumption by ca. 0.7–0.9 kW. Thanks to the fact that the temperature of the water to be treated is higher than the public supply, the thermal capacity requirement was reduced (30 kW) and both water treatment and degassing processes are more efficient. Iron content was reduced from ca. 4 to 0.013 g/m3, total hardness was reduced from 13.5 eq/m3 to <0.02 eq/m3, alkalinity was reduced from 4.45 eq/m3 to <0.01 eq/m3 and phosphate content was reduced from 0.03 to <0.006 g/m3. Thus the requirements set forth in the standards have been met and the treated geothermal water can be used to replenish network water losses in the district heating system following pH adjustment and degassing. The PN-85/C-04601 Polish Standard does not specify any requirements concerning the admissible concentrations of, inter alia, chloride and sulphate ions, i.e. anions that affect water corrosivity, mostly pitting corrosivity. These ions form soluble compounds with metals and thereby inhibit the formation and precipitation of metal oxides. The use of the membrane technology discussed here in the desalination of geothermal waters, also made it possible to achieve high retention coefficients – 97% after RO-2 for chlorides and 99% for sulphates already after RO-1.
Źródło:
Gospodarka Surowcami Mineralnymi; 2013, 29, 1; 127-139
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of self-heating susceptibility of Indian coal seams – a neural network approach
Ocena skłonności pokładów węgla w Indiach do samozapłonu – podejście oparte o wykorzystanie sieci neuronowych
Autorzy:
Panigrahi, D. C.
Ray, S. K.
Powiązania:
https://bibliotekanauki.pl/articles/219076.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
metoda badania potencjału utleniającego w procesie mokrym
samozapłon
badanie korelacji
sztuczne sieci neuronowe
temperatura przejścia
wet oxidation potential
spontaneous heating
correlation studies
artificial neural network analysis
CPT
Opis:
The paper addresses an electro-chemical method called wet oxidation potential technique for determining the susceptibility of coal to spontaneous combustion. Altogether 78 coal samples collected from thirteen different mining companies spreading over most of the Indian Coalfields have been used for this experimental investigation and 936 experiments have been carried out by varying different experimental conditions to standardize this method for wider application. Thus for a particular sample 12 experiments of wet oxidation potential method were carried out. The results of wet oxidation potential (WOP) method have been correlated with the intrinsic properties of coal by carrying out proximate, ultimate and petrographic analyses of the coal samples. Correlation studies have been carried out with Design Expert 7.0.0 software. Further, artificial neural network (ANN) analysis was performed to ensure best combination of experimental conditions to be used for obtaining optimum results in this method. All the above mentioned analysis clearly spelt out that the experimental conditions should be 0.2 N KMnO4 solution with 1 N KOH at 45°C to achieve optimum results for finding out the susceptibility of coal to spontaneous combustion. The results have been validated with Crossing Point Temperature (CPT) data which is widely used in Indian mining scenario.
W pracy omówiono możliwości wykorzystania metody elektro-chemicznej zwanej metodą określania potencjału utleniającego w procesie mokrym do określania skłonności węgla do samozapłonu. Dla potrzeb eksperymentu zebrano 78 próbek węgla z trzynastu kopalni w obrębie Indyjskiego Zagłębia Węglowego. Przeprowadzono 936 eksperymentów, w różnych warunkach prowadzenia procesu aby zapewnić standaryzację metody w celu jej szerszego zastosowania. Dla każdej próbki przeprowadzono 12 eksperymentów metodą badania potencjału utleniającego w procesie mokrym. Wyniki skorelowano z własnościami danego węgla przez przeprowadzenie badania petrograficznych i wytrzymałościowych parametrów węgla. Procedurę korelacji wykonano z wykorzystaniem oprogramowania Design Expert 7.0.0, następnie przeprowadzono analizę z wykorzystaniem sieci neuronowych w celu opracowania najkorzystniejszej kombinacji warunków eksperymentu do wykorzystania dla uzyskania optymalnych wyników. Badania wykazały, że najkorzystniejsze warunki dla procesu to zastosowanie roztworu 0.2 N KMnO4 z 1 N KOH przy 45°C dla uzyskania optymalnych wyników określania skłonności pokładów do samozapłonu. Walidację wyników przeprowadzono w oparciu o wyniki badania metodą określania temperatury przejścia (Crossing Point Temperature), szeroko stosowaną w przemyśle wydobywczym w Indiach.
Źródło:
Archives of Mining Sciences; 2014, 59, 4; 1061-1076
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Artificial Neural Network to the Control of the Parameters of the Heat Treatment Process of Casting
Autorzy:
Wróbel, J.
Kulawik, A.
Bokota, A.
Powiązania:
https://bibliotekanauki.pl/articles/382692.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat treatment
moving heat source
artificial neural network
numerical modelling
control system
heating process
obróbka cieplna
źródło ciepła ruchome
sztuczna sieć neuronowa
modelowanie numeryczne
system sterowania
proces nagrzewania
Opis:
In the paper the use of the artificial neural network to the control of the work of heat treating equipment for the long axisymmetric steel elements with variable diameters is presented. It is assumed that the velocity of the heat source is modified in the process and is in real time updated according to the current diameter. The measurement of the diameter is performed at a constant distance from the heat source (Δz = 0). The main task of the model is control the assumed values of temperature at constant parameters of the heat source such as radius and power. Therefore the parameter of the process controlled by the artificial neural network is the velocity of the heat source. The input data of the network are the values of temperature and the radius of the heated element. The learning, testing and validation sets were determined by using the equation of steady heat transfer process with a convective term. To verify the possibilities of the presented algorithm, based on the solve of the unsteady heat conduction with finite element method, a numerical simulation is performed. The calculations confirm the effectiveness of use of the presented solution, in order to obtain for example the constant depth of the heat affected zone for the geometrically variable hardened axisymmetric objects.
Źródło:
Archives of Foundry Engineering; 2015, 15, 1; 119-124
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-12 z 12

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies