Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "heat recovery system" wg kryterium: Temat


Tytuł:
Improving spark-ignited engines efficiency by heat energy recovery system
Autorzy:
Sutkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/132997.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
heat recovery system
turbo-compound
system odzysku ciepła
Opis:
The current trends in regulations changes focus more and more on emissions reduction. Earlier environment protection mechanisms covering emissions limits of particulates, nitrogen oxides, sulphur oxides and carbon monoxide were recently extended also to cover carbon dioxide emissions. One way to reduce carbon dioxide emission is the improvement of the efficiency of a powertrain system or main driver efficiency. This paper explains main limitations for efficiency improvement when conventional methods are used. The effective heat energy recovery system principles and its technical specification are described including its control principles. System was initially tested in the engine laboratory and experience from the laboratory tests is included in the paper. After successful and promising laboratory tests the solution was transferred to commercial operation which covered already period of more than 2 years. Statistics and operational data from commercial operation is shown with relevant examples of various operational modes. At the end of the paper simple feasibility study is shown. Alternative applications with basic evaluation of their feasibility and efficiency improvement potential are included in this paper as well.
Źródło:
Combustion Engines; 2015, 54, 2; 64-67
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Conceptual Design and Performance Analysis of an Exhaust Gas Waste Heat Recovery System for a 10000TEU Container Ship
Autorzy:
Ma, Zheshu
Yang, Dong
Guo, Qiang
Powiązania:
https://bibliotekanauki.pl/articles/259008.pdf
Data publikacji:
2012
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
exergy efficiency
marine diesel engine
thermal efficiency
waste heat recovery system
Opis:
According to operation characteristics of the main engine 9K98ME-C7, a combined turbines-exhaust gas waste heat recovery system is proposed to recover waste heat and increase system energy efficiency. Thermodynamic models based on the first thermodynamic law and the second thermodynamic law are formulated. The superheated steam yield, the total electric power yield, the first thermodynamic law efficiency, the exergy efficiency at different exhaust gas boiler working pressure, and the variation of the exergy efficiency under different feed water temperature and different steam turbine back pressure are analyzed. Thermodynamic results indicate that the most appropriate exhaust gas boiler pressure is 0.8MPa for studied main engine and the total thermal efficiency with combined turbines arrangement has climbed up to 53.8% from 48.5%.
Źródło:
Polish Maritime Research; 2012, 2; 31-38
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utilizacija tepla dvigatelejj mobilnykh ehnergeticheskikh sredstv
Heat recovery for engines of agricultural machinery
Autorzy:
Havrysh, V.
Shatohin, M.
Gruban, V.
Powiązania:
https://bibliotekanauki.pl/articles/78269.pdf
Data publikacji:
2015
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
agricultural machine
combine-harvester
tractor
heat recovery system
combustion engine
modernization
efficiency
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2015, 17, 2
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Issledovanie ehffektivnosti dizel-gazoturbinnojj ustanovki s termokhimicheskojj regeneraciejj tepla
Analysis of efficiency of diesel-gas turbine power plant with thermochemical heat recovery
Autorzy:
Cherednichenko, A.
Powiązania:
https://bibliotekanauki.pl/articles/76437.pdf
Data publikacji:
2015
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
diesel fuel
gas turbine
power plant
heat recovery system
waste heat
internal combustion engine
caloric value
thermodynamic property
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2015, 17, 2
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Verification of the effects of the secondary heat recovery from ventilation air in an animal house for the fattening of broiler chickens
Autorzy:
Adamovsky, R.
Adamovsky, D.
Kara, J.
Neuberger, P.
Powiązania:
https://bibliotekanauki.pl/articles/61735.pdf
Data publikacji:
2008
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
verification
secondary heat recovery
ventilation
air
animal house
fattening
broiler chicken
heat exchanger
gravitation thermal pipe
exchanger efficiency
thermal balance
specific energy consumption
energy consumption
heat recovery system
Opis:
This paper presents results of the verification of a heat exchanger composed of gravitation thermal pipes installed in a broiler chicken feeding facility. The objective of the study was to verify the possibility of the application of a power management system including a heat recovery system in a heavy-duty environment of a broiler chicken fattening facility and to specify effects of the system upon the specific consumption of energy for space heating and ventilation of the animal house. The calculation of the thermal balance of the animal house documents that the power management system that includes a heat recovery exchanger unit may reduce the thermal capacity of external sources of heat in the animal house by 26.5% even when subject to extreme conditions and at the atmospheric temperature of -12°C and the age of chickens being 1 day. The results of the metering and calculations of the efficiency have proven that the heat exchanger reaches the operational efficiency of 10–47% and thermal efficiency of 20–80% even during the most demanding operational first twenty days of the breeding cycle of broiler chickens. The specific consumption of energy for space heating and ventilation related to 1 kg of the live weight of chicken in the animal house facility A provided with a heat recovery exchanger unit at the average atmospheric temperature during the cycle being 4.3°C amounted to 278.5 Wh. In the animal house B as not provided with the heat recovery exchanger units hosting the same number of chickens and provided with the same process and thermal loss due heat transmission through peripheral structures being one half compared to the animal house A, the specific consumption of energy per 1 kg of the live weight of chicken was 420.5 Wh.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2008, 06
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of waste heat recovery systems on energy efficiency improvement of a heavy-duty diesel engine
Autorzy:
Ma, Z.
Chen, H.
Zhang, Y.
Powiązania:
https://bibliotekanauki.pl/articles/240819.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
energy efficiency design index
energy efficiency operational indicator
waste heat recovery system
performance analysis
reduction factor
wskaźnik efektywności energetycznej
wskaźniki eksploatacyjny efektywności energetycznej
system odzysku ciepła odpadowego
analiza wydajności
współczynnik redukcyjny
Opis:
The increase of ship’s energy utilization efficiency and the reduction of greenhouse gas emissions have been high lightened in recent years and have become an increasingly important subject for ship designers and owners. The International Maritime Organization (IMO) is seeking measures to reduce the CO2 emissions from ships, and their proposed energy efficiency design index (EEDI) and energy efficiency operational indicator (EEOI) aim at ensuring that future vessels will be more efficient. Waste heat recovery can be employed not only to improve energy utilization efficiency but also to reduce greenhouse gas emissions. In this paper, a typical conceptual large container ship employing a low speed marine diesel engine as the main propulsion machinery is introduced and three possible types of waste heat recovery systems are designed. To calculate the EEDI and EEOI of the given large container ship, two software packages are developed. From the viewpoint of operation and maintenance, lowering the ship speed and improving container load rate can greatly reduce EEOI and further reduce total fuel consumption. Although the large container ship itself can reach the IMO requirements of EEDI at the first stage with a reduction factor 10% under the reference line value, the proposed waste heat recovery systems can improve the ship EEDI reduction factor to 20% under the reference line value.
Źródło:
Archives of Thermodynamics; 2017, 38, 3; 63-75
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Alignment of the heat recovery potential with the local area heat demand for selected industrial entities in the city of Gliwice
Autorzy:
Banasik, Aleksandra
Kostowski, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/41185413.pdf
Data publikacji:
2023
Wydawca:
Politechnika Warszawska, Instytut Techniki Cieplnej
Tematy:
waste heat
heat recovery
district heating system
residential sector
energy management
strata ciepła
odzysk ciepła
system ciepłowniczy
sektor mieszkaniowy
zarządzanie energią
Opis:
Waste heat plays a significant role in obtaining the 4th and 5th generation of District Heating (DH) System in cities. This article presents the possibilities of integrating selected waste heat emitters into DH, with the objective of meeting the demand for heat for the selected residential area (approx. 4000 inhabitants) in the city of Gliwice (180 000 inhabitants). The total heating demand of the studied area was estimated at 19 800 GJ including both space heating and domestic hot water. The maximum thermal power was estimated at approx. 2.45 MW. The demand was calculated on the basis of registered metering values for individual buildings which were processed and summarized due to the lack of collective meters for the district. A detailed data classification, correction and completion procedure was elaborated to deal with non-uniform and low-quality data registration. Two industrial objects with waste heat generation were examined to be integrated with the local DH network. The waste heat generation potential equals 9.0 MW for plant #1 and 0.9 MW for plant #2. Apart from the constant generation declared by the industrial entities, realistic profiles including possible shaft-work and maintenance periods were created. It has been shown that the total heat demand for selected residential areas can be covered by integrating waste heat into the current DH network. Depending on the waste heat generation profile, the local area heat demand can be covered entirely or to a large degree (coverage factor ranges from 72 to 100%). The waste heat utilization factor ranges from 6.3 to 8.3%. To manage the remaining waste heat potential, it is required to build additional district heating pipelines and nodes connecting to the existing network to receive an additional 7.45 MW thermal power. The potential of waste heat recovery is significant at the scale of a medium sized city: integrating two large industrial emitters allows up to 13% decarbonization of heats production in the local district heating plan.
Źródło:
Journal of Power Technologies; 2023, 103, 2; 104-117
1425-1353
Pojawia się w:
Journal of Power Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza skuteczności odzyskiwania energii cieplnej z powietrza wywiewanego
Analyzing the operating efficiency of heat energy recovery from outlet air
Autorzy:
Besler, M.
Skrzycki, M.
Powiązania:
https://bibliotekanauki.pl/articles/236472.pdf
Data publikacji:
2009
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
odzyskiwanie energii
system wentylacji
system klimatyzacji
wymiennik ciepła
wymiana ciepła
wymiana masy
energy recovery
ventilation-conditioning system
air-conditioning system
heat exchanger
heat transfer
mass transfer
Opis:
W pracy wykazano celowość odzyskiwania ciepła z powietrza wywiewanego w systemach wentylacyjnych i klimatyzacyjnych w aspekcie oszczędności energii oraz omówiono wynikające z tego korzyści. Przedstawiono podstawy teoretyczne związane z odzyskiwaniem ciepła. Opisano przemiany zachodzące w trakcie procesów wymiany ciepła i masy w wymiennikach do odzyskiwania ciepła. Na podstawie rzeczywistych parametrów z wieloletnich pomiarów powietrza zewnętrznego badanych we Wrocławiu porównano pracę takich urządzeń, jak regeneracyjny obrotowy wymiennik ciepła, krzyżowo-płytowy wymiennik ciepła, regeneracyjny nieobrotowy wymiennik ciepła oraz rurka ciepła. Pracę urządzeń porównano z recyrkulacją powietrza oraz pracą układu bez odzyskiwania ciepła. Przeanalizowano te urządzenia pod kątem różnych trybów pracy w trakcie całorocznej eksploatacji oraz pod kątem wybranych typów paliw, wykorzystanych do wytworzenia ciepła do zasilania układu. Porównując koszt zużycia energii pierwotnej i koszty inwestycyjne urządzeń w różnych układach wentylacyjnych/klimatyzacyjnych wykazano, że w każdym z rozpatrywanych przypadków zastosowanie urządzeń odzyskujących energię z powietrza wywiewanego należy ocenić jako korzystne z punktu widzenia całkowitych kosztów eksploatacji instalacji wentylacyjnych.
The advantages of heat recovery from the outlet air in ventilation and air conditioning systems were analyzed in terms of energy savings and related benefits. The paper also includes theoretical explanations for the basic phenomena and processes dealt with in heat recovery, and describes (in the form of charts) the changes that occur in the state of the air during heat and mass transfer processes in heat exchangers. The study covered the time span of 1998 to 2007, where each year was divided into two thermal seasons: the cold season (temperatures <15 C) and the warm season (temperatures >15 C). Using the real parameter values obtained from many years' external air measurements conducted in the city of Wroclaw, the operating efficiencies were compared for the following devices: rotary heat exchangers, cross-flow heat exchangers, regenerative nonrotary heat exchangers and heat pipes. The operation of the devices was compared with the operation of a system with no heat recovery. The devices were analyzed according to the parameters of the system's operation throughout the year, as well as according to the type of the fuel used for generating the heat supplied to the system. The comparison of the costs of the original energy consumed and the capital costs for the devices of the ventilation/air-conditioning systems examined has revealed that in every instance the application of devices providing energy recovery from outlet air has to be regarded as advantageous in terms of the overall operating costs of the ventilation systems.
Źródło:
Ochrona Środowiska; 2009, 31, 1; 41-47
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System pozyskiwania energii cieplnej z sond geotermalnych
Integrated heat energy system of the livestock building and ground boreholes
Autorzy:
Kreis-Tomczak, K.
Powiązania:
https://bibliotekanauki.pl/articles/238919.pdf
Data publikacji:
2008
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
pompa ciepła
sonda geotermalna
odzysk ciepła
energia słoneczna
heat pump system
ground boreholes
heat recovery
solar energy
livestock building
Opis:
Z prac różnych badaczy dotyczących pozyskiwania energii z sond geotermalnych wynika, że temperatura gruntu z sondą geotermalną spada pod koniec okresu grzewczego, a w pobliżu sondy grunt ochładza się przez pierwsze 2-3 lata. Po tym okresie proces się stabilizuje, ale temperatura gruntu pozostaje niższa o 1-2 K w porównaniu z gruntem bez sondy. Symulacja tego procesu w okresie 25-letniej eksploatacji pokazała, że po tym okresie deficyt temperatury pozostaje na poziomie 0,1 K. Ponieważ odzysk ciepła z sondy geotermalnej może powodować zachwiania we właściwościach cieplnych gruntu, w IBMER podjęto prace nad przywróceniem tej równowagi. W pierwszym etapie badano system oparty na wymiennikach gruntowych bez podłączenia dachu energetycznego. Badania prowadzono w okresie od 26.01-16.03.2007. Dokonywano odczytów energii cieplnej uzyskanej z sond geotermalnych oraz energii, która została przesłana do obiegu górnego źródła (c.o.). Uzyskano 5,834 GJ energii cieplnej (1620,56 kWh), a dostarczono 447,1 kWh energii elektrycznej. Z obliczeń energii dostarczonej do uzyskanej wynika, że współczynnik COP wynosi 3,9. W tym okresie dostarczono do obiegu c.o. 5,836 GJ energii cieplnej.
Many studies by different researchers show that the temperature close to a borehole is dropping quickly in winter during first 2 years, only to stay more or less stable over the next years. In the summer time, initial temperatures are not achieved again, but the temperature drop is decreasing from year to year. According to computer simulation, a complete recovery will occur after an indefititely long time period; nevertheless, the remaining temperature deficit after 25 years since the operation has been stopped, at the level of 0.1 K only. Because the heat recovery from boreholes could disturb thermal properties of the ground, some research works were undertaken by IBMER, to bring this balance back. The aim of research dealing with the system which included energy roof, deep litter and ground boreholes, was to determine the efficiency of heat delivery/recovery to and from the boreholes, in aspects of hydrogeothermal processes near the boreholes. System of boreholes (without energy roof) was investigated at the first stage of research. Investigations were conducted since 26.01. to 16.03.2007. Amounts of the heat from boreholes and heat conveyed to the central heating system were recorded. Over investigation period 5.834 GJ (1620.56 kWh) of heat energy have been gained, in comparison to electric en-ergy input on the level 447.1 kWh. The input energy to the gained energy ratio (COP) amounted to 3.9. During investigations 5.836 GJ of heat energy were delivered to the central heating system.
Źródło:
Problemy Inżynierii Rolniczej; 2008, R. 16, nr 2, 2; 167-174
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exergy-based control strategy in a dwelling ventilation system with heat recovery
Oparta na egzergi strategia sterowania systemem wentylacji mieszkań z odzyskiem ciepła
Autorzy:
Voloshchuk, Volodymyr
Polishchuk, Mariya
Powiązania:
https://bibliotekanauki.pl/articles/407846.pdf
Data publikacji:
2020
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
ventilation system
exergy analysis
control
heat recovery
exergy saving
system wentylacji
analiza egzergii
kontrola
odzysk ciepła
oszczędność egzergii
Opis:
The paper presents energy and exergy analysis of a typical dwelling ventilation system with heat recovery for Ukrainian climatic conditions using a quasi-steady state approach over 24-hour time-steps. Evaluation of such systems on the base of the first law of thermodynamics demonstrates that heat recovery is beneficial for the whole variety of operational modes. Such methodology identifies as a thermodynamic inefficiency only energy losses to the surroundings with the exhaust air. The exergy-based analysis can detect additional inefficiencies due to irreversibilities within the components of the system. As a result the exergetic investigations show that for the ventilation systems there are operating conditions for which heat recovery increases exergy of fuel expended to provide the ventilation air compared to cases without bringing any recovery of heat and additional power consumption to drive the air flow by the fans. For the specified system, in case of switching ventilation unit to the operation mode of lower values of spent fuel exergy it is possible to provide annual saving of the primary energy sources from 5 to 15%.
W pracy przedstawiono analizę energetyczną i egzergetyczną typowego systemu wentylacji mieszkań z odzyskiem ciepła dla ukraińskich warunków klimatycznych z zastosowaniem podejścia quasi-stabilnego w 24-godzinnych krokach czasowych. Ocena takich systemów w oparciu o pierwsze prawo termodynamiki wykazuje, że odzysk ciepła jest korzystny dla całego szeregu trybów pracy. Taka metodologia identyfikuje jako nieefektywne termodynamicznie tylko straty energii do otoczenia wraz z powietrzem wylotowym. Analiza egzergetyczna może wykryć dodatkowe nieefektywności wynikające z nieodwracalności elementów systemu. W rezultacie badania egzergetyczne wykazują, że w systemach wentylacyjnych występują warunki pracy, dla których odzysk ciepła zwiększa egzergię paliwa zużytego do dostarczenia powietrza wentylacyjnego w porównaniu do przypadków, w których nie występuje żaden odzysk ciepła i dodatkowe zużycie energii elektrycznej do napędzania przepływu powietrza przez wentylatory. Dla określonego systemu, w przypadku przełączenia urządzenia wentylacyjnego na tryb pracy o niższych wartościach egzergii zużytego paliwa możliwe jest zapewnienie rocznych oszczędności pierwotnych źródeł energii od 5 do 15%.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2020, 10, 2; 44-47
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies