Tytuł:
Research to estimate energy efficiency of a ventilation and air conditioning heat pump system inside a production premise with ventilation air recovery
Autorzy:
Bezrodny, Myhailo Kostiantynovych
Misiura, Tymofii Oleksiyovych
Powiązania:
https://bibliotekanauki.pl/articles/1955060.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
air conditioning
heat pump system
refrigeration efficiency
recuperation
Opis:
The research provides a thermodynamic analysis of the theoretical model of a ventilation and air conditioning heat pump system with the ventilation air cold energy recovery depending on outside air parameters, the recovery efficiency and characteristics of a premise. A confectionery production workshop was taken as a prototype where technological conditions (temperature and humidity) must be maintained during the warm season. Calculations using the method of successive approximations to estimate air parameters at system’s nodal points were conducted. It allowed to determine theoretical refrigeration efficiency of the studied system and proved advantages of heat recuperation for smaller energy consumption. The model can be applied for design of heating, ventilation, and air conditioning units which work as a heat pump. The studied system has the highest energy efficiency in the area of relatively low environment temperatures and relative humidity which is suitable for countries with temperate continental climates characterized by low relative humidity.
Źródło:
Archives of Thermodynamics; 2021, 42, 4; 69-86
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania mocy cieplnej w pompie zębatej 3PZ4
Autorzy:
Osiński, P.
Huss, W.
Bury, P.
Kiec, K.
Powiązania:
https://bibliotekanauki.pl/articles/304497.pdf
Data publikacji:
2018
Wydawca:
Wydawnictwo Druk-Art
Tematy:
pompa zębata
ciepło strat
przegrzanie cieczy hydraulicznej
układ hydrauliczny
wymiana ciepła
gear pump
heat of loss
overheating of the hydraulic fluid
hydraulic system
heat exchange
Opis:
Zbyt wysoka temperatura cieczy hydraulicznej uniemożliwia poprawną pracę układu hydraulicznego i skraca trwałość jego elementów. Pompa zębata o zazębieniu zewnętrznym, z powodu ograniczonej sprawności wynikającej z cech konstrukcyjnych, jest znacznym źródłem ciepła w układzie. Ciepło to w znacznej części odbierane jest przez ciecz hydrauliczną w warunkach konwekcji wymuszonej oraz przez powietrze otoczenia, głównie poprzez konwekcję naturalną. W artykule zaprezentowano wyniki badań dotyczące wzrostu temperatury cieczy hydraulicznej pomiędzy stroną tłoczną a ssawną oraz źródeł ciepła w pompie 3PZ4 produkcji WPH. Wykonano w ramach projektu p.t. „Opracowanie konstrukcji wysokociśnieniowych pomp zębatych”, realizowanego w ramach Programu Badań Stosowanych w ścieżce A Umowa Nr PBS3/A6/22/2015.
Too high hydraulic fluid temperature prevents the correct operation of the hydraulic and reduces the durability of its components. Gear pump with external gear due to reduced efficiency resulting from construction is a significant source of heat in the system. The heat is largely received by hydraulic fluid under conditions of forced convection and ambient air, mainly through natural convection. The article presents the results of tests on the hydraulic fluid temperature rise between the discharge and suction and heat sources in the pump 3PZ4 WPH production. Was performed within the framework of the project entitled “Development of a design of the high-pressure gear pumps” in the framework of the Research Used in the path A, the agreement No PBS3/A6/22/2015.
Źródło:
Napędy i Sterowanie; 2018, 20, 3; 110-114
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative Analysis of Heating, Ventilation and Electricity Costs on the Example of Residential Building in the Near Zero-Energy Standard
Analiza porównawcza kosztów ogrzewania, wentylacji i energii elektrycznej na przykładzie budynku mieszkalnego w standardzie niemal zeroenergetycznym
Autorzy:
Krajewska, M.
Szopińska, K.
Powiązania:
https://bibliotekanauki.pl/articles/385421.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
low-energy-consumption building
operating cost
natural gas
heat pump
photovoltaic system
budynek o niskim zużyciu energii
koszty eksploatacji
gaz ziemny
pompa ciepła
system fotowoltaiczny
Opis:
This article deals with an analysis of the operating costs of a building designed in the “near zero-energy” standard, with various technological solutions for heating and ventilation supported by a photovoltaic system (three technological variants). Following the analysis, a technological variant using an economic criterion based on the minimization of annual operating costs was selected.
W artykule przedstawiono analizę kosztów eksploatacji budynku projektowanego w standardzie “niemal zeroenergetycznym”, przy różnych wariantowych rozwiązaniach technologicznych ogrzewania i wentylacji wspomaganych systemem fotowoltaicznym (trzy warianty technologiczne). W następstwie przeprowadzonych analiz zarekomendowano wybór wariantu technologicznego przy zastosowaniu kryterium ekonomicznego opartego na minimalizacji rocznych kosztów eksploatacji.
Źródło:
Geomatics and Environmental Engineering; 2018, 12, 3; 55-64
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy zarządzania energią elektryczną i termiczną przykładowego pojazdu elektrycznego
Problems of electricity and thermal management of an exemplary electric vehicle
Autorzy:
Lechowicz, A.
Augustynowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/1196930.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
pojazd elektryczny
układ chłodzenia i ogrzewania pojazdu
pompa ciepła
electric car
cooling and heating system
heat pump
Opis:
The article presents the work characteristics and energy balance of the Renault ZOE electric ca heating and cooling system. The vehicle uses an innovative solution for an air-based cooling system based on a controlled heat pump that can work as a cooling and heating system. The presented work presents a diagram of this solution and an analysis of its operation and energy consumption with particular emphasis on the heat pump during the heating up of the vehicle. As part of these tests, an emergency mode test was also carried out when the state of charge of the traction battery reached the minimum value of the capacity.
W artykule przedstawiono charakterystykę pracy i bilans energii systemu ogrzewania i chłodzenia samochodu elektrycznego Renault ZOE. W pojeździe tym zastosowano rozwiązanie powietrznego systemu chłodzenia opartego na sterowanej pompie ciepła, która może pracować jako układ chłodzący i podgrzewający. W prezentowanej pracy przedstawiono schemat tego rozwiązania oraz przeprowadzono analizę jego pracy i zużycia energii ze szczególnym uwzględnieniem pompy ciepła w czasie nagrzewania pojazdu. W ramach tych badań przeprowadzono również test trybu awaryjnego, gdy stan naładowania akumulatora trakcyjnego osiągnął minimalną wartość pojemności.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2018, 3, 119; 77-81
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of heat source location on surface temperature distribution of the indoor side of external walls in an uninsulated apartment in Warsaw during the heating season
Autorzy:
Różycki, K.
Powiązania:
https://bibliotekanauki.pl/articles/104195.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
air-to-air heat pump
uninsulated building
thermovision
alternative heating system
wall
Opis:
This article presents the influence of the heat source location to surface temperature distribution of the indoor side of external walls in an uninsulated apartment in Warsaw during the heating period. The apartment is located in a multi-family residential building. This building has never been thermomodernized and therefore it is highly energy-consuming. In 2016, an air-to-air heat pump was installed in the apartment and replaced the existing heat source, a dual-function gas boiler. The device is used both for heating the apartment during the heating period and cooling it during the summer. Such system works particularly well in non-insulated objects, in which the partition’s internal surface temperature changes dynamically as the outside temperature changes. This article describes the results of the thermovision test of the walls of this flat. The surface internal temperature distribution on the selected three walls was examined under different atmospheric conditions while maintaining similar internal conditions.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 3; 65-72
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza i propozycja zastosowania pomp ciepła w geotermalnym systemie c.o. w Poddębicach
Analysis and proposal for heat pump use in the geothermal district heating system in Poddębice
Autorzy:
Pająk, L.
Skrzypczak, R.
Kępińska, B.
Powiązania:
https://bibliotekanauki.pl/articles/203971.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
Poddębice
wody geotermalne
pompy ciepła
geotermalny system c.o
odbiorcy energii
Poddębice region
geothermal water
heat pump
geothermal heating system
energy consumers
Opis:
Artykuł informuje o zasobach geotermalnych dostępnych w rejonie Poddębic w odniesieniu do dolno-kredowego poziomu wodonośnego. Scharakteryzowano infrastrukturę i moc systemu ciepłowniczego wykorzystującego tamże ciepło jego wód. Scharakteryzowano także potencjalnych nowych odbiorców ciepła z tego systemu. Przedstawiono model źródła energii dla obecnych i przyszłych odbiorców ciepła oraz przeanalizowano różne warianty jego pracy, w tym szczytowe zastosowanie pomp ciepła. Dla kolejnych wariantów oceniono efekty: energetyczny, ekonomiczny i ekologiczny. W odniesieniu do pracy systemu z uwzględnieniem nowych odbiorców ciepła wskazano na zasadność skorzystania wówczas z pomp ciepła, lecz jako efektywniejsze rozwiązanie zarekomendowano politykę obniżania wymaganej temperatury zasilania instalacji grzewczej u odbiorców i obniżania temperatury powrotu wody.
The article informs about the geothermal resources available in the Poddębice region in relation to the Lower Cretaceous aquifer. It characterizes the infrastructure and power of the heating system utilizing the heat of its water. This is also characterized by potential new heat recipients from this system. A model of the source of energy for current and future heat consumers was presented, and various variants of its operation were analyzed, including the peak use of heat pumps. For further variants, the following effects were evaluated: energetic, economic and ecological. With respect to the operation of the system with regard to new heat consumers it was pointed out that the use of heat pumps was a good idea, but as a more effective solution, the policy of reducing the required flow temperature of the heating system the part of the customer and lowering the return temperature was recommended.
Źródło:
Technika Poszukiwań Geologicznych; 2017, R. 56, nr 2, 2; 33-52
0304-520X
Pojawia się w:
Technika Poszukiwań Geologicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of the method of implementing the forced air flow through the cooling system on the temperature of the coolant in heavy-duty engines
Autorzy:
Worsztynowicz, B.
Powiązania:
https://bibliotekanauki.pl/articles/133256.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
heavy duty engine
cooling system
heat transfer
coolant pump
fan
silnik dużej mocy
układ chłodzenia
wymiana ciepła
pompa cieczy chłodzącej
wentylator
Opis:
The article discusses the problem how forced air flow is implemented through the cooling module of heavy-duty engines. The kinematic connection between the coolant pump and the crankshaft of the engine, results in the fact that the pump performance often does not correspond to the engine demand at its part load. In conjunction with the fan drive method, the temperature of the coolant may be too low or too high for part load. The study was carried out in order to calculate the parameters of the cooling system in heavy-duty engines for maximum power and maximum torque, taking into account a mechanical fan drive, a hydraulic fan drive and an electric fan drive.
Źródło:
Combustion Engines; 2017, 56, 4; 51-55
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected issues of the economic analysis of a heating system with the direct evaporation heat pump
Wybrane aspekty analizy ekonomicznej systemu grzewczego z zastosowaniem pomp ciepla bezposredniego odparowania
Autorzy:
Tucki, K.
Sikora, M.
Karlikowska, M.
Bedkowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/792271.pdf
Data publikacji:
2016
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
heating system
heat pump
evaporation
modernization
economic analysis
investment
cost
calculation
energy consumption
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2016, 16, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected issues of the technical analysis of a heating system using the direct evaporation heat pump
Wybrane aspekty analizy technicznej systemu grzewczego z zastosowaniem pomp ciepla bezposredniego odparowania
Autorzy:
Tucki, K.
Sikora, M.
Karlikowska, M.
Bedkowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/792573.pdf
Data publikacji:
2016
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
heating system
heat pump
evaporation
renewable energy
renewable energy source
energy management
environment
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2016, 16, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utilization of the horizontal ground heat exchanger in the heating and cooling system of a residential building
Autorzy:
Hanuszkiewicz-Drapała, M.
Bury, T.
Powiązania:
https://bibliotekanauki.pl/articles/240110.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat pump
ground heat exchanger
heating system
numerical modelling
pompa ciepła
gruntowy wymiennik ciepła
system grzewczy
modelowanie numeryczne
Opis:
This paper presents the results of thermodynamic analyses of a system using a horizontal ground heat exchanger to cool a residential building in summer and heat it in the autumn-winter period. The main heating device is a vapour compression heat pump with the ground as the lower heat source. The aim of the analyses is to examine the impact of heat supply to the ground in the summer period, when the building is cooled, on the operation of the heating system equipped with a heat pump in the next heating season, including electricity consumption. The processes occurring in cooling and heating systems have an unsteady nature. The main results of the calculations are among others the time-dependent values of heat fluxes extracted from or transferred to the ground heat exchanger, the fluxes of heat generated by the heat pump and supplied to the heated building by an additional heat source, the parameters in characteristic points of the systems, the temperature distributions in the ground and the driving electricity consumption in the period under analysis. The paper presents results of analysis of cumulative primary energy consumption of the analyzed systems and cumulative emissions of harmful substances.
Źródło:
Archives of Thermodynamics; 2016, 37, 1; 42-72
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A study of a heat pump ground collector
Badania wymiennika gruntowego pompy ciepła
Autorzy:
Szreder, M.
Powiązania:
https://bibliotekanauki.pl/articles/792689.pdf
Data publikacji:
2014
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
ground source heat pump
vertical collector
spiral compressor
heat source
coefficient performance
heating system
power consumption
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2014, 14, 3
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza czynników niskotemperaturowych do instalacji grzewczej w jednorodzinnym budynku mieszkalnym
Analysis of low temperature factors for a heating system in a detached residential building
Autorzy:
Lenz, M.
Piwowarski, M.
Stępień, R.
Wiśniewski, D.
Hałacz, J.
Powiązania:
https://bibliotekanauki.pl/articles/208492.pdf
Data publikacji:
2012
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
energetyka
instalacja grzewcza
pompa ciepła
energetics
heating system
heat pump
Opis:
W niniejszej pracy przeprowadzono analizę projektową instalacji grzewczej opartej na sprężarkowej pompie ciepła. Instalacja ta zasila systemy centralnego ogrzewania i przygotowania ciepłej wody użytkowej w jednorodzinnym budynku mieszkalnym znajdującym się w miejscowości Koleczkowo. W analizie zawarto ocenę strat i zysków cieplnych budynku, obliczenia zapotrzebowania na moc cieplną analizowanego obiektu oraz koncepcyjne rozwiązania instalacji grzewczej. Zaproponowano wariant optymalny ze względu na maksymalną sprawność, do którego dobrane zostały jego główne elementy. Przeanalizowano wpływ grupy wybranych czynników chłodniczych na sprawność oraz parametry pracy zaproponowanej pompy ciepła.
This study involves a design analysis of the heating system based on a compression heat pump. This installation supplies central heating and tap water heating systems in a detached residential building situated in Koleczkowo. The analysis includes an assessment of heat loss and gain of the building, calculations of the demand for the heating power of the building under analysis and conceptual solutions concerning the heating system. The optimal variant was proposed with regard to its maximum efficiency, for which the main elements were chosen. The effects of the set of selected cooling factors on the efficiency and operating parameters of the proposed heat pump are also analysed.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2012, 61, 2; 331-345
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the influence of variable insulating power of a storing tank on energy effects in the conversion system of solar radiation
Autorzy:
Kurpaska, S.
Latala, H.
Powiązania:
https://bibliotekanauki.pl/articles/793373.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
solar collector
heat pump
storing tank
insulation
solar radiation
conversion
hybrid system
thermal balance
energy stream
water temperature
daily change
heat balance
analysis
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 2
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency of the heat pump cooperating with various heat sources in monovalent and bivalent systems
Efektywnosc pompy ciepla wspolpracujacej z dolnymi zrodlami ciepla w systemie mono i biwalentnym
Autorzy:
Kurpaska, S.
Latala, H.
Lapczynska-Kordon, B.
Mudryk, K.
Powiązania:
https://bibliotekanauki.pl/articles/792536.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
heat pump
heat source
heat distribution
monovalent system
bivalent system
compressor heat pump
vertical exchanger
horizontal exchanger
coefficient performance
heating system
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Symulacja efektywności wykorzystania pompy ciepła w okrętowych instalacjach klimatyzacyjnych
Simulation of efficiency of utilization of the heat pump in the ship air-conditioning system
Autorzy:
Pojawa, B.
Trzebiński, S.
Powiązania:
https://bibliotekanauki.pl/articles/395463.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
efektywność energetyczna
badania symulacyjne
pompa ciepła
okrętowa instalacja klimatyzacyjna
efficiency of utilization
simulation
heat pump
ship air-conditioning system
Opis:
W procesie eksploatacji siłowni okrętowych ciągle aktualną jest potrzeba oceny ich efektywności energetycznej oraz emisji szkodliwych dla środowiska naturalnego produktów spalania. Potrzebę prowadzenia badań w tym zakresie, wymuszają również w pewnym stopniu, obowiązujące uregulowania prawne w zakresie efektywności energetycznej oraz ochrony środowiska. Z uwagi na powyższe podjęto się wstępnych badań mających na celu poprawę efektywności energetycznej siłowni okrętowej oraz zmniejszenie emisji szkodliwych produktów spalin poprzez zastosowanie w okrętowej instalacji klimatyzacyjnej pompy ciepła. W artykule przedstawiono identyfikację instalacji klimatyzacyjnej oraz sposób określania zapotrzebowania energii na jej potrzeby. Na podstawie teorii obiegów lewobieżnych oraz bilansowania energetycznego opracowano uproszczony model matematyczny umożliwiający dokonywanie bilansowania energii na potrzeby instalacji klimatyzacyjnej, dla różnych parametrów stanu dolnego i górnego źródła ciepła. Symulacja efektywności wykorzystania pompy ciepła w okrętowej instalacji klimatyzacyjnej, z udziałem opracowanego modelu matematycznego, pozwala na określenie ilości paliwa możliwej do zaoszczędzenia oraz towarzyszącej temu zmniejszonej emisji związków szkodliwych spalin.
The need for assessment of efficiency of marine power plants as well as of emissions of combustion products harmful for the environment still remains a topical issue regarding the process of exploitation of these plants. The need for research in this scope is also enforced, to a certain extent, by legal regulations in respect of energy efficiency and environment protection. Taking the above into consideration, preliminary research was undertaken which aims at the improvement of energy efficiency of marine power plants and at the decrease of the emissions of harmful exhaust products, to be achieved by means of the application of a heat pump in the ship air-conditioning system. The article presents the identification of the air-conditioning system as well as the way of defining the demand for energy consumed by such a system. Basing on the theory of the counterclockwise cycles and energy balancing, a simplified mathematical model was elaborated, which makes it possible to balance the energy indispensable for the air-conditioning system, for various parameters of the state of the top and bottom heat sources. Simulation of efficiency of utilization of the heat pump in the ship air-conditioning system, with the help of the elaborated mathematical model, allowed defining the volume of fuel possible to be spared as well as the accompanying decreased emissions of harmful exhaust compounds.
Źródło:
Postępy Nauki i Techniki; 2012, 15; 134-144
2080-4075
Pojawia się w:
Postępy Nauki i Techniki
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies