Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "heat plant" wg kryterium: Temat


Tytuł:
A co-generation power set with a combustion engine fuelled by wood waste gas
Autorzy:
Taler, J.
Mruk, A.
Cisek, J.
Majewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/245220.pdf
Data publikacji:
2015
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
biomass
combined heat and power (CHP) plant
wood gasification
renewable energy sources
internal combustion engine
Opis:
This paper presents a concept and a technical analysis of a co-generation power set with a combustion engine powered by syngas produced in the process of wood waste gasification. The set is composed of a wood waste gas generator fitted with a filter system, a combustion engine, a current generator and heat exchangers. The foundations of the gasification process are described together with the most common solutions used worldwide. Moreover, the methods of adapting spark-ignition and compression-ignition engines to be powered by syngas produced in the wood waste gasification process are presented. The advantages of the presented solution and its possible applications in industry are shown. The assumed technical parameters of the set are as follows: mechanical-electrical energy – 200 kWh, heat recovered from the gasifier – 250 kWh, heat recovered from the engine – 200 kWh. The concept and design of the module cogeneration set is the effect of actions taken by the Institute of Automobiles and Internal Combustion Engines and by the Institute of Thermal Power Engineering of the Cracow University of Technology.
Źródło:
Journal of KONES; 2015, 22, 2; 249-257
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A mathematical model of two-stage Solid Oxide Fuel Cell, SOFC, stacks for dynamic simulation of Combined Heat and Power system fed by natural gas
Autorzy:
Palus, Mateusz
Pianko-Oprych, Paulina
Powiązania:
https://bibliotekanauki.pl/articles/1849273.pdf
Data publikacji:
2021
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
dynamic model
natural gas
Solid Oxide Fuel Cell stacks
Combined Heat and Power
CHP
system
Balance of Plant
BoP
modelling
Catalytic Partial Oxidation
CPOx
reformer
steam reformer
Opis:
Zero-dimensional two-stage SOFC stacks dynamic model was developed to investigate the effect of operating parameters on stacks performance. The model resolves spatially thermal and thermo-electrochemical behaviour for electrochemical reactions, Catalytic Partial Oxidation and Steam Reforming processes. Design variables and thermo-electrochemical properties were obtained from in-house-fabricated SOFCs carried out by project partners. The completed SOFCs based Combined Heat and Power, CHP, system model was validated by data18 and numerical results obtained at steady-state mode showing its high-fidelity. A parametric study with respect to key operating parameters including changes in fuel utilization, lambda number and current density values was conducted. The global CHP system dynamic response, in term of the current/voltage delivered by two-stage SOFC stacks, under a fi xed fuel utilization, has been determined resulting in greater variations in the voltage of a single cell in the first stack in comparison to the corresponding values in the second stack.
Źródło:
Polish Journal of Chemical Technology; 2021, 23, 2; 1-11
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A mathematical model of two-stage Solid Oxide Fuel Cell, SOFC, stacks for dynamic simulation of Combined Heat and Power system fed by natural gas
Autorzy:
Palus, Mateusz
Pianko-Oprych, Paulina
Powiązania:
https://bibliotekanauki.pl/articles/1849268.pdf
Data publikacji:
2021
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
dynamic model
natural gas
Solid Oxide Fuel Cell stacks
Combined Heat and Power
CHP
system
Balance of Plant
BoP
modelling
Catalytic Partial Oxidation
CPOx
reformer
steam reformer
Opis:
Zero-dimensional two-stage SOFC stacks dynamic model was developed to investigate the effect of operating parameters on stacks performance. The model resolves spatially thermal and thermo-electrochemical behaviour for electrochemical reactions, Catalytic Partial Oxidation and Steam Reforming processes. Design variables and thermo-electrochemical properties were obtained from in-house-fabricated SOFCs carried out by project partners. The completed SOFCs based Combined Heat and Power, CHP, system model was validated by data18 and numerical results obtained at steady-state mode showing its high-fidelity. A parametric study with respect to key operating parameters including changes in fuel utilization, lambda number and current density values was conducted. The global CHP system dynamic response, in term of the current/voltage delivered by two-stage SOFC stacks, under a fi xed fuel utilization, has been determined resulting in greater variations in the voltage of a single cell in the first stack in comparison to the corresponding values in the second stack.
Źródło:
Polish Journal of Chemical Technology; 2021, 23, 2; 1-11
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aktualne uwarunkowania ekonomiczno-techniczne i formalno-prawne rozwoju przedsiębiorstwa kogeneracyjnego w Polsce
Current techno-economic and legal conditions affecting the development of a Combined Heat and Power Plant in Poland
Autorzy:
Kamiński, J
Stós, K.
Powiązania:
https://bibliotekanauki.pl/articles/282265.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
przedsiębiorstwo energetyczne
elektrociepłownia
rozwój
energy company
combined heat and power plant
development
Opis:
Niniejszy artykuł stanowi próbę kompleksowego podejścia do zidentyfikowania uwarunkowań rozwoju przedsiębiorstwa z branży energetycznej w Polsce i jest odpowiedzią na wybiórcze podejście do poruszanych zagadnień w literaturze przedmiotu. W artykule zostały przedstawione uwarunkowania, mające decydujący wpływ na długoterminowy rozwój przedsiębiorstwa energetycznego na przykładzie elektrociepłowni. Autorzy wyróżnili i omówili uwarunkowania formalno-prawne i ekonomiczno-techniczne. W ramach uwarunkowań ekonomicznych scharakteryzowali zagadnienia związane z popytem na ciepło i energię elektryczną, kwestię wpływu rosnącej efektywności energetycznej oraz sprawy związane z dostępnością oraz kosztami zakupu paliw.Wgrupie uwarunkowań formalno-prawnych przybliżyli kluczowe dokumenty i regulacje formalno-prawne wyznaczające ramy prowadzenia działalności energetycznej w Polsce. W ramach grupy uwarunkowań technicznych omówili czynniki wynikające z posiadanej infrastruktury technicznej i jej ograniczeń ze szczególnym zwróceniem uwagi na istotny problem bardzo zaawansowanego stopnia zużycia infrastruktury energetycznej.
This article is an attempt at a comprehensive approach to identifying the determinants of business development in the energy sector in Poland, and is a response to selective approaches to the issues discussed in other works. The article evaluates factors that have a decisive impact on the long-term development of an energy company, considering the case study of a combined heat and power plant. This includes a review of economic, technical, and legal/regulatory conditions. In the context of economic conditions, the paper characterizes matters related to the demand for heat and electricity, the impact of increasing energy efficiency, and the availability and cost of fuels purchased. In the group of legal/ regulatory conditions, key documents and regulations defining the legal framework for energy activities in Poland are described. Lastly, technical issues to be reviewed consider the existing infrastructure and its technical constraints, with special emphasis on the problem of obsolete energy sector infrastructure.
Źródło:
Polityka Energetyczna; 2014, 17, 3; 181-191
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An influence of fouling gathered on the heat transfer surfaces on the heat performance characteristics of the ship steam systems heat exchangers
Autorzy:
Hajduk, T.
Powiązania:
https://bibliotekanauki.pl/articles/1841551.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Morski w Gdyni. Wydział Nawigacyjny
Tematy:
marine power plant
gathering of fouling
heat transfer surface
heat performance characteristics
thermal resistance
heat trransfer
heat exchangers
Opis:
More than half of the incidents reported to EMSA relate to nautical events such as collision, groundings and contacts. Knowledge of accurate and high-integrity positioning is therefore not only a need for future automated shipping but a base for today’s safe navigation. Examples on accidents include Ever Given in the Suez Canal and HNoMS Helge Ingstad in Norway. A Network-RTK (NRTK) service can be used as an augmentation technique to improve performance of shipborne GNSS receivers for future positioning of manned and unmanned vessels in restricted areas, such as port areas, fairways, and inland water ways. NRTK service providers generate RTK corrections based on the observations of networks of GNSS reference stations which enables the users to determine their position with centimeter accuracy in real-time using a shipborne GNSS receiver. Selection of appropriate communication channels for dissemination of NRTK corrections data is the key to a secure positioning (localization) service. In PrePare-Ships project, the modern maritime communication system VDES (VHF Data Exchange System) is proposed to distribute SWEPOS (NRTK in Sweden) correction data to shipborne positioning modules. VDES is a very reliable technique and it is compatible with most onboard functionalities. In order to minimize the impact on the overall VDES data capacity in a local area, NRTK correction data shall only occupy a single VDES slot with a net capacity of 650 bytes. Update rates may vary but are preferably at 1Hz. However, NRTK correction data size changes instantly, depending on the number of visible GNSS satellites, and the data rate can therefore sometimes reach in excess of 1000 byte/s. In this study, a smart technique is proposed to reduce size of NRTK correction data to instantly adapt with the VDES requirements by choosing a combination of specific signals, satellites or even constellations such that the data rate is not more than 650 byte/s, and at the same time it achieves optimal positioning performance with the accuracy required by the PrePare-Ships project application.
Źródło:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation; 2021, 15, 1; 183-189
2083-6473
2083-6481
Pojawia się w:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza pracy elektrociepłowni geotermalnej z obiegiem ORC
Analysis of operating a geothermal heat and power plant with the ORC cycle
Autorzy:
Wiśniewski, S.
Powiązania:
https://bibliotekanauki.pl/articles/203890.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
elektrociepłownia geotermalna
siłownia ORC
czynnik roboczy
czynnik organiczny
energia geotermalna
geothermal heat
power plant
ORC Power plant
organic working fluid
geothermal energy
Opis:
W niniejszym artykule przedstawiona została wstępna analiza funkcjonowania elektrociepłowni wykorzystującej zasoby geotermalne Niżu Polskiego. W założeniach przyjęto, że strumień wydobywanej wody termalnej wynosi Vg = 100 m3/h, temperatura na wypływie tg1 = 100°C, mineralizacja S = 120 g/kg. System pozyskiwania energii geotermalnej składa się z dubletu geotermalnego. W warunkach Niżu Polskiego wydobywana woda termalna zazwyczaj charakteryzuje się wysoką mineralizacją, co zostało uwzględnione w obliczeniach związanych z możliwością wykorzystania tych zasobów, z uwagi na fakt zmienności pojemności cieplnej właściwej oraz gęstości wraz ze zmianą mineralizacji. W pracy przeanalizowano dwa warianty: wariant 1 (letni), wariant 2 (zimowy). W wariancie 1 woda termalna kierowana jest w pierwszej kolejności do układu ORC, a następnie do systemu ciepłowniczego. W wariacie drugim woda termalna najpierw przepływa przez wymiennik systemu ciepłowniczego, a następnie jest kierowana do układu ORC. Obliczenia wykazały, że w obu wariantach istnieje możliwość generacji energii elektrycznej w układzie ORC rozpatrywanej elektrociepłowni przy jednoczesnym dostarczaniu ciepła. Przedstawione rozwiązania dają również możliwość zmiany temperatury nośnika ciepła w sieci ciepłowniczej poprzez zmianę temperatury odparowania czynnika organicznego, zmianę wariantu lub wykorzystanie wymiennika regeneracyjnego.
This article presents a preliminary analysis of the operation of heat and power plants using geothermal resources in the conditions of the Polish Lowlands. The paper assumes that a stream of geothermal water is Vg =100 m3/h, the temperature at the outlet tg1 = 100°C, mineralization of S = 120 g/kg. The geothermal energy system consists of a geothermal doublet, which means that water is extracted one opening, and injected in the second. The paper analyzes two variants: variant 1 (summer), variant 2 (winter). In the variant 1 geothermal water is first directed to the ORC heat exchanger and then to the heating heat exchanger. In the second variant geothermal water flows through the heat exchanges and then is directed to the ORC. Calculations have shown that it is possible in both variants power generation in the ORC power plants while providing thermal energy. The presented solution also provides a possibility of changing the temperature of heat carrier in the district heating network by changing the evaporation temperature of the organic medium, the change variants or the use of a regenerative heat exchanger in the ORC circuit.
Źródło:
Technika Poszukiwań Geologicznych; 2016, R. 55, nr 2, 2; 155-167
0304-520X
Pojawia się w:
Technika Poszukiwań Geologicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza termodynamiczna i ekonomiczna hierarchicznej, dwuobiegowej elektrowni jądrowej z regeneracją ciepła
Autorzy:
Bartnik, Ryszard
Powiązania:
https://bibliotekanauki.pl/articles/2096857.pdf
Data publikacji:
2021
Wydawca:
Nowa Energia
Tematy:
analiza termodynamiczna
ekonomia
elektrownia jądrowa
regeneracja ciepła
thermodynamic analysis
economy
nuclear power plant
heat regeneration
Opis:
W pracach [1-3] przedstawiono termodynamiczną i ekonomiczną analizę hierarchicznej elektrowni jądrowej z jednym, chłodzonym helem wysokotemperaturowym reaktorem HTGR. W pracy [4] zaprezentowano natomiast analizę elektrowni z dwoma takimi reaktorami. W niniejszej pracy ponownie przeanalizowano elektrownię z dwoma reaktorami HTGR, jednak w porównaniu z [4] z tą istotną różnicą, że w wysokotemperaturowym obiegu Joule’a zastosowano regenerację ciepła (rys. 1, 2), która znacząco zwiększa jego sprawność.
Źródło:
Nowa Energia; 2022, 2; 86-97
1899-0886
Pojawia się w:
Nowa Energia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza termodynamiczna i ekonomiczna hierarchicznej elektrociepłowni gazowo-gazowej sprzęgniętej ze sprężarkową pompą ciepła
Autorzy:
Bartnik, Ryszard
Powiązania:
https://bibliotekanauki.pl/articles/31804076.pdf
Data publikacji:
2022
Wydawca:
Nowa Energia
Tematy:
analiza termodynamiczna
analiza ekonomiczna
elektrociepłownia gazowa
sprężarkowa pompa ciepła
thermodynamic analysis
economic analysis
gas power plant
compressor heat pump
Opis:
W pracy [1] przedstawiono analizę termodynamiczną i ekonomiczną hierarchicznych elektrowni i elektrociepłowni gazowo-gazowych (rys. 1). W [2] zaprezentowano ich pracę trójgeneracyjną z wykorzystaniem ziębiarek cieplnych i sprężarkowych.
Źródło:
Nowa Energia; 2022, 4; 86-100
1899-0886
Pojawia się w:
Nowa Energia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza termodynamiczna i ekonomiczna wpływu objętości akumulatora ciepła na jednostkowy koszt produkcji ciepła w elektrociepłowni gazowo-parowej
Autorzy:
Bartnik, Ryszard
Buryn, Zbigniew
Hnydiuk-Stefan, Anna
Powiązania:
https://bibliotekanauki.pl/articles/31804085.pdf
Data publikacji:
2022
Wydawca:
Nowa Energia
Tematy:
analiza termodynamiczna
analiza ekonomiczna
akumulator ciepła
produkcja ciepła
elektrociepłownia gazowo-parowa
thermodynamic analysis
economic analysis
heat accumulator
heat production
gas-steam combined heat and power plant
Opis:
Wysoka cena gazu ziemnego (szczególnie obecnie podyktowana imperialną polityką Niemiec i Rosji), którego koszt może zatem nawet przekraczać 70-75% rocznych kosztów działania elektrociepłowni gazowo-parowych [6], powoduje często nieopłacalność ekonomiczną ich zastosowania (rys. 4, 5). Opłacalność tę można poprawić przez zastosowanie w nich akumulatorów ciepła (rys. 5). Dzięki nim w sezonie ogrzewczym w szczycie potrzeb Krajowego Systemu Elektroenergetycznego (KSE) produkowana będzie w elektrociepłown dodatkowa ilość energii elektrycznej, a w sytuacji zmniejszonego na nią zapotrzebowania w dolinie obciążenia KSE będzie miało miejsce jej obniżenie.
Źródło:
Nowa Energia; 2022, 3; 64-79
1899-0886
Pojawia się w:
Nowa Energia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zagrożenia pożarowo-wybuchowego stwarzanego przez wybrane środki ochrony roślin wraz z oceną ich potencjalnego wpływu na środowisko
Analysis of the fire and explosion hazard posed by selected plant protection products with an assessment of their potential impact on the environment
Autorzy:
Kukfisz, B.
Powiązania:
https://bibliotekanauki.pl/articles/92616.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
środki ochrony roślin
charakterystyka wybuchowości
kinetyka generacji ciepła
plant protection products
explosion characteristics
heat release rate
Opis:
W artykule przedstawiono zagrożenia stwarzane przez wybrane środki ochrony roślin stosowane w rolnictwie zawierające substancje aktywne z grupy pyretroidów (lambda-cyhalotryna, beta-cyflutryna i deltametryna), które wytypowano na podstawie rejestru środków ochrony roślin dopuszczonych do obrotu zezwoleniem Ministra Rolnictwa i Rozwoju Wsi [1, 2]. Wyznaczono parametry wybuchowe stwarzane przez obłoki pyłów wybranych substancji i preparatów oraz zakwalifikowano je do odpowiednich klas wybuchowości [3, 4]. W zakresie zagrożenia pożarowego metodą kalorymetru stożkowego przy poziomym ułożeniu próbki przy obecności palnika pilotowego określono szybkość wydzielania ciepła [5].
The article presents the threats posed by selected plant protection products used in agriculture containing active substances from the pyrethroid group (lambda-cyhalothrin, beta-cyfluthrin and deltamethrin), which were selected on the basis of the register of authorized plant protection products granted marketing authorization by the Ministry of Agriculture and Rural Development [1, 2]. Explosive parameters created by dust clouds of selected substances and preparations were determined and classified in appropriate explosion classes [3, 4]. In terms of flammability danger, values of heat release rate were determined on the basis of calorimetric analysis of specimens exposed in the horizontal orientation to controlled levels of irradiation with an external igniter [5].
Źródło:
Materiały Wysokoenergetyczne; 2018, T. 10; 13-21
2083-0165
Pojawia się w:
Materiały Wysokoenergetyczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of heat load in a biomass-fired boiler
Analiza obciążenia cieplnego w kotle opalanym biomasą
Autorzy:
Bartoszewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/172829.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
biomasa
ciepłownia
kocioł ciepłowniczy
biomass
heat-generating plant
heating boiler
Opis:
This paper discusses an exemplary cooperation between a research center, industry and technical inspection authorities. The purpose of the investigations (carried out to find the failure of a biomass-fired boiler in a heating plant) is an analysis of the effect of operating water boiler conditions on the heat load of the heating surface. The analysis concerns the reasons for failure of the membrane heat exchanger of the water-gas type being a basic heating surface of the boiler burning biomass. During the operation of the boiler some cracks perforated the bottom and smoke tube endings occurred.
W artykule przedstawiono wyniki współpracy ośrodka naukowego, ciepłowni miejskiej i inspekcji technicznej realizowanych w celu wykrycia przyczyn awarii kotła opalanego biomasą. Przedstawiono wyniki analizy numerycznej oraz wizualizacji w ciepłowni w celu określenia tych przyczyn. Badania obejmowały analizę przepony wymiennika ciepła typu woda-spaliny, który stanowi podstawową powierzchnię wymiany ciepła w kotle spalającym biomasę. Przedstawione w pracy wnioski z analizy wskazują na przyczyny pęknięć płyty sitowej i końcówek płomieniówek wymiennika.
Źródło:
Archiwum Energetyki; 2011, 41, 1; 65-77
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the interrelation between the heat balance structure, type of plant cover and weather conditions
Autorzy:
Eulenstein, F.
Lesny, J.
Chojnicki, B.H.
Kedziora, A.
Olejnik, J.
Powiązania:
https://bibliotekanauki.pl/articles/25168.pdf
Data publikacji:
2005
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
weather condition
heat balance structure
environment
interrelation
evapotranspiration
latent heat
plant cover
sensible heat
Źródło:
International Agrophysics; 2005, 19, 2
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Applying the life cycle assessment method to an analysis of the environmental impact of heat generation
Autorzy:
Dzikuć, M.
Powiązania:
https://bibliotekanauki.pl/articles/955269.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
energia
ekologia
ciepło
elektrownia
life cycle assessment (LCA)
energy
ecology
heat
power plant
Opis:
The paper presents a method of Life Cycle Assessment (LCA) to determine the impact of the heat produced on the environment. In addition, the usefulness of this method to assess the energy sector has been shown. This paper presents the impact of heat generation on the environment in coal power plants. A detailed analysis by the method of LCA is made to compare the environmental impact of heat generation in the Legnica Power Plant and Polkowice Power Plant. It is pointed to the difference in the results obtained. Moreover, the causes of the reported environmental impacts are discussed. Measures are identified which will help to reduce in the future the impact of the electricity produced on the environment during the production of heat.
Źródło:
International Journal of Applied Mechanics and Engineering; 2013, 18, 4; 1275-1281
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of district heating needs and technical possibilities in the vicinity of a future polish nuclear power station
Autorzy:
Cholewiński, M.
Tomków, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/1189974.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
elektrownia jądrowa
kogeneracja
system ciepłowniczy
popyt na ciepło
nuclear power plant
cogeneration
district heating system
pressurised water reactor
heat demand
Opis:
Nuclear power plants can be a reliable source of heat supplying district heating systems. Importantly, thermal and flow parameters of a secondary loop in pressurized water reactor technologies are sufficient to supply a district heating networks. Therefore, NCHP (Nuclear Combined Heat and Power) systems seem to be a viable replacement for traditional coal-fired cogeneration units located in big cities and may contribute to environmental protection in both local and international scale. In this paper working conditions of a municipal heat network, such as a pressure drop and the heat loses, were calculated and adapted to expected Poland’s first nuclear power plant located in Pomerania Province. Cumulative probability distribution model of heat generation power in metropolitan area and future heat demand have been created and used to identify optimal size of NCHP heat output. Main parameters of heating network were presented and discussed. The positive effects on environment were assessed and summarized as well.
Źródło:
Interdisciplinary Journal of Engineering Sciences; 2017, 5, 1; 1--10
2300-5874
Pojawia się w:
Interdisciplinary Journal of Engineering Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cast construction elements for heat treatment furnaces
Autorzy:
Piekarski, B.
Drotlew, A.
Powiązania:
https://bibliotekanauki.pl/articles/382333.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
innovative foundry technology
innovative foundry material
heat treatment plant
innowacyjna technologia odlewnicza
innowacyjny materiał odlewniczy
zakład obróbki cieplnej
Opis:
The study presents sketches and photos of the cast creep-resistant components used in various types of heat treatment furnaces. The shape of the elements results from the type of the operation carried out in the furnace, while dimensions are adjusted to the size of the furnace working chamber. The castings are mainly made from the high-alloyed, austenitic chromium-nickel or nickel-chromium steel, selecting the grade in accordance with the furnace operating conditions described by the rated temperature, the type and parameters of the applied operating atmosphere, and the charge weight. Typical examples in this family of construction elements are: crucibles, roller tracks, radiant tubes and guides. The majority of castings are produced in sand moulds.
Źródło:
Archives of Foundry Engineering; 2011, 11, 3 spec.; 163-170
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies