Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "heart rate monitoring" wg kryterium: Temat


Tytuł:
Energy expenditure of athletes endurance and strength in the light of the Polish energy intake standards
Autorzy:
Frączek, Barbara
Grzelak, Andrzej
Klimek, Andrzej T.
Powiązania:
https://bibliotekanauki.pl/articles/2161987.pdf
Data publikacji:
2019-02-27
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
athletes
heart rate monitoring
daily energy expenditure
training energy expenditure
endurance sports
power sports
Opis:
Objectives The purpose of the study was to estimate training energy expenditure (TEE) and daily energy expenditure (DEE) in the Polish elite athletes engaged in endurance sports and power sports, and to compare their levels with the Polish energy intake standards. Material and Methods The study sample consisted of 30 athletes (15 women and 15 men) whose energy expenditure was estimated based on heart rate monitoring. Results The mean values of DEE obtained for women engaged in endurance sports (WE – women endurance) and power sports (WP – women power) were 3201±533 kcal and 3217±554 kcal, respectively. In the group of male athletes, the respective values were 4518±717 kcal for endurance athletes (ME – men endurance) and 4459±837 kcal for power athletes (MP – men power). The mean values of TEE for female athletes were 819±240 kcal (WE) and 1047±248 kcal (WP). Those obtained for male athletes were significantly higher: 1440±675 kcal (ME) and 1337±331 kcal (MP). Conclusions Unlike the demands of particular sport disciplines, an athlete’s sex proved to be a factor causing significant differences between the TEE and DEE of athletes representing different sport disciplines. Individual athletes were found to differ significantly in their demand for energy, which in some cases was considerably different from what energy intake standards propose. Int J Occup Med Environ Health. 2019;32(1):1–13
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2019, 32, 1; 1-13
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of MEMS accelerometer for baby apnea monitoring under home conditions
Zastosowanie akcelerometrów MEMS do monitorowania bezdechu niemowląt w warunkach domowych
Autorzy:
Tewel, N.
Powiązania:
https://bibliotekanauki.pl/articles/261980.pdf
Data publikacji:
2010
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
akcelerometr MEMS
bezdech niemowląt
SIDS
monitorowanie tętna
monitorowanie oddechu
infant apnea
MEMS accelerometer
respiratory monitoring
heart rate monitoring
Opis:
Cleep apnea episedes may cause potential baby's life threateiiing events and can be one of t h e first syndromes of other 11-laesses. Apnea is supposed to be one of t h e risk factors of Sudden Infant Death Syndrome (SIDS). Infanfs breath monitoring and immediate apnea detection, not oniy in hospitals, but also under home conditions, mereases the baby's safety and aiiow recognition of cliseases at an earlier stage. This paper presents a model of n ew device for detection of apnea, consisting of a three-axis MEMS (Micro Electro-Mechanical Systems) accelerometer with digital output, microprocessor and sosie alarm Instruments. The deyice allows the monitoring of both, the breathing movements of the child's abdomen, as weil as the vibrations of th e abdominal wali associated with t h e heart action and enables early detection of central and obstractiye apnea. Another usefu! application of die described model i s the possibility of monitoring t h e baby- 'a position during sleep. The paper presents the hardware, apnea detection procedure and the performance of the physical model of the apnea monitor.
Bezdech senny stanowi potencjalne zagrożenie życia niemowląt i może być pierwszym syndromem innych schorzeń. Jest on uznawany za jeden z czynników ryzyka Zespołu Nagłego Zgonu Niemowląt (SIDS - Sudden Infant Death Syndrome). Monitorowanie oddechu niemowląt i szybkie rozpoznawanie stanów bezdechu nie tylko w szpitalu, ale także w warunkach domowych, zwiększa bezpieczeństwo dziecka i ułatwia wykrywanie innych chorób w ich wczesnym stadium. Przedstawiony artykuł opisuje model nowego urządzeniu przeznaczonego do wykrywania bezdechu, zbudowanego z akcelerometru MEMS (Micro Elektro-Mechanical Systems) o trzech osiach czułośći z wyjściem cyfrowym, mikroprocesora i elementów alarmujących. Urządzenie monitoruje ruchy oddechowe dziecka i wibracje ściany brzucha towarzyszące pracy serca, przez co umożliwia szybkie wykrywanie zarówno bezdechu centralnego, jak i obturacyjnego. Inną użyteczną funkcją prezentowanego modelu jest możliwość kontroli pozycji dziecka podczas snu. W artykule opisano układ, procedurę detekcji bezdechu oraz pierwsze wyniki uzyskane z wykorzystaniem przedstawionego modelu monitora.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2010, 16, 4; 389-393
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Distant Measurement of Plethysmographic Signal in Various Lighting Conditions Using Configurable Frame-Rate Camera
Autorzy:
Przybyło, J.
Kańtoch, E.
Jabłoński, M.
Augustyniak, P.
Powiązania:
https://bibliotekanauki.pl/articles/221113.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
photoplethysmography
remote patient monitoring
heart rate detection
video signal processing
Opis:
Videoplethysmography is currently recognized as a promising noninvasive heart rate measurement method advantageous for ubiquitous monitoring of humans in natural living conditions. Although the method is considered for application in several areas including telemedicine, sports and assisted living, its dependence on lighting conditions and camera performance is still not investigated enough. In this paper we report on research of various image acquisition aspects including the lighting spectrum, frame rate and compression. In the experimental part, we recorded five video sequences in various lighting conditions (fluorescent artificial light, dim daylight, infrared light, incandescent light bulb) using a programmable frame rate camera and a pulse oximeter as the reference. For a video sequence-based heart rate measurement we implemented a pulse detection algorithm based on the power spectral density, estimated using Welch’s technique. The results showed that lighting conditions and selected video camera settings including compression and the sampling frequency influence the heart rate detection accuracy. The average heart rate error also varies from 0.35 beats per minute (bpm) for fluorescent light to 6.6 bpm for dim daylight.
Źródło:
Metrology and Measurement Systems; 2016, 23, 4; 579-592
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fuzzy system for evaluation of fetal heart rate signals using FIGO criteria
Autorzy:
Czabański, R.
Jeżewski, M.
Wróbel, J.
Jeżewski, J.
Horoba, K.
Powiązania:
https://bibliotekanauki.pl/articles/333142.pdf
Data publikacji:
2009
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitoring płodu
tętno płodu
kryteria FIGO
fetal monitoring
fetal heart rate
signal classification
fuzzy systems
Opis:
Cardiotocography is a biophysical method of fetal monitoring during pregnancy and labour. It is mainly based on recording and analysis of fetal heart activity. The computerized fetal monitoring systems provide the quantitative description of the recorded signals but the effective methods supporting the conclusion generation are still needed. The evaluation of the signal can be made using criteria recommended by FIGO. Nevertheless, the quantitative description of the traces is inconsistent with qualitative nature of the obstetric knowledge. Therefore, we applied the fuzzy system based on Takagi-Sugeno-Kang model to evaluate and classify signals. FIGO guidelines were used for developing a set of fuzzy conditional rules defining the system performance. The proposed system was evaluated using data collected with computerized fetal surveillance system – MONAKO. The classification results confirm the improvement of the fetal state evaluation quality while using the proposed fuzzy system support.
Źródło:
Journal of Medical Informatics & Technologies; 2009, 13; 189-194
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prolonged job strain reduces time-domain heart rate variability on both working and resting days among cardiovascular-susceptible nurses
Autorzy:
Borchini, Rossana
Bertù, Lorenza
Ferrario, Marco M.
Veronesi, Giovanni
Bonzini, Matteo
Dorso, Marco
Cesana, Giancarlo
Powiązania:
https://bibliotekanauki.pl/articles/2176995.pdf
Data publikacji:
2015-02-24
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
nurses
job strain
heart rate variability
HRV
time-domain parameters
ECG-monitoring
Opis:
Introduction Modifications of hearth rate variability (HRV) constitute a marker of the autonomic nervous system (ANS) deregulation, a promising pathway linking job strain (JS) and cardiovascular diseases (CVD). The study objective is to assess whether exposures to recent and prolonged JS reduce time-domain HRV parameters on working days (WD) among CVD-susceptible nurses and whether the association also persists on resting days (RD). Material and methods 313 healthy nurses were investigated twice with one year interval to assess JS based on the demand-control and the effort-reward models. 36, 9 and 16 CVD-susceptible nurses were classified as low JS in both surveys (stable low strain – SLS), recent high JS (high JS at the second screening only-RHS) and prolonged high JS (high strain in both surveys-PHS), respectively. In 9, 7 and 10 of them, free from comorbidities/treatments interfering with HRV, two 24-h ECG recordings were performed on WD and RD. Differences in the time domain HRV metrics among JS categories were assessed using ANCOVA, adjusted for age and smoking. Results In the entire sample (mean age: 39 years, 83% females) the prevalence of high job strain was 38.7% in the second survey. SDNN (standard deviation of all normal RR intervals) on WD significantly declined among JS categories (p = 0.02), with geometric mean values of 169.1, 145.3 and 128.9 ms in SLS, RHS, PHS, respectively. In the PHS group, SDNN remained lower on RD as compared to the low strain subjects (142.4 vs. 171.1 ms, p = 0.02). Similar findings were found for the SDNN_Index, while SDANN (standard deviation of average RR intervals in all 5 min segments of registration) mean values reduced in the PHS group during WD only. Conclusions Our findings suggest that persistent JS lowers HRV time-domain parameters, supporting the hypothesis that the ANS disorders may play an intermediate role in the relationship between work stress and CVD.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2015, 28, 1; 42-51
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of instantaneous fetal heart rate extracted from abdominal and direct fetal electrocardiograms
Autorzy:
Matonia, A.
Kupka, T.
Jezewski, J.
Momot, A.
Jeżewski, M.
Bernys, M.
Powiązania:
https://bibliotekanauki.pl/articles/333262.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
elektrokardiografia płodu
tętno płodu
fetal monitoring
fetal electrocardiography
fetal heart rate
Opis:
This work is an attempt to assess the reliability of indirect abdominal electrocardiography as an alternative technique of fetal monitoring. As a reference signal we used the simultaneously acquired direct fetal electrocardiogram. Each recording consisted of four signals acquired from maternal abdomen and the reference signal acquired directly from fetal head. The first stage of our study concerned the signal loss episodes. In order to reduce the influence of incorrectly detected R-waves, some certain validation rules were applied. In the second stage, the corresponding intervals determined on basis of both acquisition methods were matched and the accuracy of fetal heart rate measurement was evaluated. Although the accuracy of abdominal electrocardiography turned out to be slightly lower than reported for ultrasound method, it still has some unique features deciding of its prevalence in a certain circumstances.
Źródło:
Journal of Medical Informatics & Technologies; 2012, 19; 101-107
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computerized fetal monitoring based on bioelectric signals from maternal abdomen
Autorzy:
Matonia, A.
Jeżewski, J.
Gacek, A.
Kupka, T.
Horoba, K.
Wróbel, J.
Powiązania:
https://bibliotekanauki.pl/articles/333805.pdf
Data publikacji:
2002
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
elektrokardiografia
tętno płodu
fetal monitoring
fetal abdominal
electrocardiography
fetal heart rate
Opis:
The paper presents an instrumentation set for effective diagnostics of early symptoms of fetal distress in high-risk pregnancy based on bioelectric signals recording. The representative database of records has been established that enabled the complex analysis of signals recorded on a surface of maternal abdomen. As an outcome, the effective algorithms have been developed for processing both the fetal electrocardiogram and the signal of electrical activity of a uterine muscle. This allowed the development of unique diagnostic system based on external biosignal measurement module connected to the standard personal computer. In this system, like in a classical fetal monitor, the fetal heart rate (FHR) signal together with contraction activity signal of uterine muscle and fetal movement become an essential source of information on fetal condition. In addition, there is a possibility for spectral analysis of FHR signal as well as a morphology assessment of fetal ECG signal.
Źródło:
Journal of Medical Informatics & Technologies; 2002, 4; MT37-47
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cardiovascular changes in workers exposed to fine particulate dust
Autorzy:
Bortkiewicz, Alicja
Gadzicka, Elżbieta
Stroszejn-Mrowca, Grażyna
Szyjkowska, Agata
Szymczak, Wiesław
Koszada-Włodarczyk, Wiesława
Szadkowska-Stańczyk, Irena
Powiązania:
https://bibliotekanauki.pl/articles/2178789.pdf
Data publikacji:
2014-03-22
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
ceramic industry
heart rate variability
air pollution
respirable dust
blood pressure monitoring
ABPM
Opis:
Objectives: Epidemiological studies provide evidence that airborne particulate matter may contribute to the increased incidence and mortality rates due to pulmonary and cardiovascular diseases. Only some of them address the problem of occupational exposure to particulate air pollution. The aim of our study was to assess cardiovascular reaction and autonomic regulation in workers exposed to fine particles. Materials and Methods: All workers had medical examination, resting ECG with heart rate variability analysis (HRV), 24-h ECG, and ambulatory blood pressure monitoring (ABPM) performed. The subjects were 20 male workers (mean age: 32.14.0 year) of a ceramic ware factory exposed to the dust and 20 workers who were not exposed (mean age: 39.4±7.8 year). The period of employment under exposure amounted to 5.6±2.1 year. Dust exposure was measured using individual dosimeters. Results: The geometric mean total dust concentration was 44±1.5 mg/m³ and the FPD (fine particulate dust) concentration amounted to 11.5±1.6 mg/m³. No abnormalities were noted in the resting ECG in both groups, in 24-h ECG 2 subjects, both from exposed and control groups, had ventricular heart rhythm and repolarization disturbances. Blood pressure in ABPM, both systolic as well as diastolic, was normal and did not differ between the groups. Resting heart rate in the exposed group was significantly lower (p = 0.038) than in the control group. In the exposed group STD R-R from short-term records was significantly higher (p = 0.01). Fast Fourier Transform (FFT) analysis showed that the low frequency power spectrum (LF) did not differ in the exposed and the control group, while high frequency (HF) was significantly higher in the exposed group. LF/HF ratio was significantly lower in the exposed in comparison with the control group. Conclusions: Although we did not reveal significant abnormalities in ECG as well as in ABPM in the exposed group, it seems that neurovegetative disturbances (parasympathetic predominance) may serve as an early indicator of fine particulate dust effect on cardiovascular system.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2014, 27, 1; 78-92
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of window size of autocorrelation function on fetal heart rate variability measurement using the Doppler ultrasound signal
Autorzy:
Roj, D.
Fuchs, T.
Przybyła, T.
Jeżewski, M.
Matonia, A.
Gacek, A.
Powiązania:
https://bibliotekanauki.pl/articles/333477.pdf
Data publikacji:
2008
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitoring płodu
tętno płodu
USG Dopplera
funkcja autokorelacji
fetal monitoring
fetal heart rate
Doppler ultrasound
autocorrelation function
Opis:
Commonly used noninvasive fetal monitoring is based on fetal heart rate (FHR) variability analysis of the Doppler ultrasound signal coming from the mechanical activity of the fetal heart. Estimation of periodicity of acquired signals using the autocorrelation technique is very important. The determination of cardiac intervals using the Doppler signal is more difficult than in electrocardiography, where the R-waves are evident. We investigated the influence of the autocorrelation window size on the FHR variability analysis. The indices describing the FHR variability calculated for signals obtained using two different autocorrelation techniques with various window lengths were compared with the reference ones obtained from fetal electrocardiogram. The optimal window was a compromise between artifacts resistance and the averaging level of instantaneous variability.
Źródło:
Journal of Medical Informatics & Technologies; 2008, 12; 111-116
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improving the periodicity measurement in fetal heart activity signal
Autorzy:
Roj, D.
Wróbel, J.
Horoba, K.
Przybyła, T.
Kupka, T.
Powiązania:
https://bibliotekanauki.pl/articles/332933.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
tętno płodu
USG metodą Dopplera
fetal monitoring
fetal heart rate
ultrasound Doppler
Opis:
In this paper we discussed the influence of preliminary processing of the ultrasound Doppler signal on accuracy of the fetal heart rate estimation as well as on reliability of the FHR instantaneous variability assessment. We attempted to develop an optimal processing channel of US Doppler signal in order to measure the periodicity of fetal heart activity with accuracy as close as possible to that ensured by FECG. The FHR values determined from the US signal were compared to the reference data obtained from direct FECG. In a final evaluation we used the parameters describing the FHR variability as the clinically important signal features being the most sensitive to any periodicity inaccuracy. The results proved that an application of proposed algorithms improves the accuracy of interval measurements and FHR instantaneous variability assessment in relation to the new-generation fetal monitors.
Źródło:
Journal of Medical Informatics & Technologies; 2010, 16; 19-26
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of predictive capabilities of quantitative cardiotocographic signal features
Autorzy:
Czabański, R.
Jeżewski, M.
Roj, D.
Szaszkowski, Z.
Kupka, T.
Wróbel, J.
Powiązania:
https://bibliotekanauki.pl/articles/332937.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
tętno płodu
klasyfikacja sygnału
fetal monitoring
fetal heart rate
signal classification
ROC analysis
Opis:
Cardiotocography (CTG) is the main method of assessment of the fetal state during pregnancy and labour used in clinical practice. It is based on quantitative analysis of fetal heart rate, fetal movements and uterine contractions signals. The evaluation of the CTG signals can be made using criteria recommended by International Federation of Obstetrics and Gynecology. Nevertheless, the diagnosis verification is possible only after the delivery on the basis of newborn assessment. In the proposed work we evaluated the capacity of quantitative analysis of CTG traces in predicting fetal outcome. The relationship between CTG signal features and attributes of fetal outcome was assessed on the basis of ROC curves analysis. The obtained results indicate the adequate predictive capabilities of the selected CTG features especially for fetal outcome assessed with Apgar score and suggest the necessity of applying the criteria for the CTG traces evaluation that are related to the gestational age. Our study also shows the value of the CTG monitoring as a screening procedure providing appropriate confirmation of fetal wellbeing.
Źródło:
Journal of Medical Informatics & Technologies; 2010, 16; 11-17
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Inconsistency in evaluation of clinical patterns in fetal heart rate waveforms
Autorzy:
Jeżewski, J.
Horoba, K.
Wróbel, J.
Gacek, A.
Powiązania:
https://bibliotekanauki.pl/articles/333801.pdf
Data publikacji:
2002
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
tętno płodu
przyspieszanie / zwalnianie
fetal monitoring
fetal heart rate
acceleration/deceleration
expert inconsistency
Opis:
Acceleration and deceleration patterns in fetal heart rate (FHR) are widely used as an assessment of fetal condition. The basis for both visual and automated quantitative analysis is correctly determined fetal heart rate baseline. There are many methods for automated fetal heart rate baseline estimation. Since there are no definitive criteria or "gold standard" to evaluate algorithms for baseline determination, a clinical expert could be considered as a reference. Taking into account that not the shape of baseline itself but the results of quantitative analysis obtained using this baseline are important, we stated that such evaluation should be done only on the basis of comparison of effects - the recognized accelerations and decelerations. However, the first step for such comparison is to check how well expert meets established FIGO definition of accelerations and decelerations patterns in FHR trace. The paper presents a method for evaluation of expert's interpretation of these definitions. Two indices describing the inconsistency among fetal monitoring system and experts have been defined. The results obtained indicate the essential differences in procedure of accelerations/decelerations recognition by the computerized system and human expert.
Źródło:
Journal of Medical Informatics & Technologies; 2002, 4; MT27-35
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Coincidence of maternal and fetal QRS complexes in view of fetal heart rate determination
Autorzy:
Kupka, T.
Jeżewski, J.
Matonia, A.
Wróbel, J.
Horoba, K.
Powiązania:
https://bibliotekanauki.pl/articles/333792.pdf
Data publikacji:
2002
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
brzuszne EKG płodu
monitorowanie płodu
tętno płodu
abdominal fetal electrocardiogram
fetal monitoring
fetal heart rate
Opis:
Indirect fetal electrocardiography is a developing diagnostic method in perinatal medicine. Signals of electrical activity being recorded from maternal abdomen surface contain more information than in till now used method of mechanical heart activity measurement based on ultrasound signals. The main problem relies on separation of basic useful component from a signal containing also dominant maternal electrocardiogram and muscles activity artifacts. The algorithms of maternal electrocardiogram suppression via subtraction are commonly used. Although regarding their complexity, these algorithms have limited applicability in systems for long-term monitoring of fetal heart activity. Other solution relies on simple blanking of maternal QRS complexes. However, in case of coincidence of fetal and maternal QRS complexes, this leads to partial loss of information about fetal heart rate variability. For evaluation of how often such coincidence of both complexes takes place, the algorithm has been developed which is described in this paper.
Źródło:
Journal of Medical Informatics & Technologies; 2002, 4; MT49-55
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fuzzy prediction of fetal acidemia
Autorzy:
Czabański, R.
Roj, D.
Jeżewski, J.
Horoba, K.
Jeżewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/333483.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
tętno płodu
klasyfikacja sygnału
systemy rozmyte
fetal monitoring
fetal heart rate
signal classification
fuzzy systems
Opis:
Cardiotocography is the primary method for biophysical assessment of a fetal state. It is based mainly on the recording and analysis of fetal heart rate signal (FHR). Computer systems for fetal monitoring provide a quantitative description of FHR signals, however the effective methods for their qualitative assessment are still needed. The measurements of hydronium ions concentration (pH) in newborn cord blood is considered as the objective indicator of the fetal state. Improper pH level is a symptom of acidemia being the result of fetal hypoxia. The paper proposes a twostep analysis of signals allowing for effective prediction of the acidemia risk. The first step consists in the fuzzy classification of FHR signals. The task of fuzzy inference is to indicate signals that according to the FIGO guidelines represent the fetal wellbeing. These recordings are eliminated from the further classification with Lagrangian Support Vector Machines. The proposed procedure was evaluated using data collected with computerized fetal surveillance system. The classification results confirmed the high quality of the proposed fuzzy method of fetal state evaluation.
Źródło:
Journal of Medical Informatics & Technologies; 2011, 17; 81-87
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A routing protocol for wireless network of bedside monitors in fetal surveillance system
Autorzy:
Seredynski, R.
Horoba, K.
Roj, D.
Bernys, M.
Przybyla, T.
Jezewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/333626.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
tętno płodu
sieci bezprzewodowe
protokoły rutowania
symulacja
fetal monitoring
fetal heart rate
wireless networks
routing protocol
simulation
Opis:
The paper presents the methodology of wireless network design, developed according to the requirements originating from existing wired fetal surveillance systems. The proposed network structure is based on popular radio frequency modules, operating in 433/866MHz band. The described solution is a simple and cost effective alternative to the wired networks, and it will vastly increase the mobility of fetal monitors. The authors also describe software tools which were designed for this purpose and the results of simulations performed on their basis.
Źródło:
Journal of Medical Informatics & Technologies; 2012, 21; 27-33
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies