Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "harmonic load" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Circuit for Balancing Harmonic-Polluted Three-Phase Networks
Autorzy:
Saied, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/262835.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
harmonic analysis
power quality
load balancing
frequency scan
Steinmetz circuit
Opis:
This paper presents a new circuit capable of balancing harmonics-polluted three-phase power networks supplying single-phase loads. It takes into account the negative and positive sequences exhibited by the fifth and seventh harmonics, respectively. The concept extends the relations of the Steinmetz circuit, which are based exclusively on fundamental frequency considerations. The Steinmetz circuit does not, therefore, guarantee the balancing of the different harmonics in the line currents. Furthermore, it can lead to resonances between the capacitive and inductive elements in the two added balancing branches. A procedure for identifying the topology and the circuit parameters of the proposed connection is given. The results of a detailed case study are presented in order to demonstrate the superiority of the proposed circuit over the conventional Steinmetz connection.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2013, 16, 1; 19-24
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of harmonic detection methods under non-ideal conditions in ship power network
Autorzy:
Xu, X.-Y.
Mindykowski, J.
Tarasiuk, T.
Cheng, C.
Powiązania:
https://bibliotekanauki.pl/articles/259840.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
distorted three-phase voltage
rapid-variation load
harmonic detection
average arithmetic
Opis:
An improved harmonic detection method based on average arithmetic is proposed. According to the research results, the designed solution uses an LPF (low-pass-filter) and a mean value module connected in series instead of the conventional mean value module, and simultaneously, a three-phase voltage phase-locked module instead of commonly used PLL (phase lock loop) module is applied in order to reduce the influence caused by three-phase distorted voltage and rapid variation of load. The experimental results show that the application of this solution leads to increase in the accuracy of harmonics detection for distorted three-phase voltage and rapid variation of load.
Źródło:
Polish Maritime Research; 2015, 3; 82-89
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Harmonic analysis of the wind-loaded bar dome at the Satellite Services Centre in Psary
Analiza harmoniczna kopuły prętowej Centrum Usług Satelitarnych w Psarach obciążonej wiatrem
Autorzy:
Szaniec, W.
Zielińska, K.
Powiązania:
https://bibliotekanauki.pl/articles/231008.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
obciążenie wiatrem
analiza harmoniczna
rezonans
drgania własne
drgania wymuszone
wind load
harmonic analysis
resonance
natural vibrations
forced vibrations
Opis:
The research paper presents the results of the dynamic analysis of an existing bar dome subjected to wind loads. The calculation model of the structure was constructed using the finite element method. The dome was subjected to the standard wind pressure, assuming that it is operates in a harmonic manner. The numerical analyses were performed with the application of Autodesk Robot and MES3D. The analysis focused on the impact of selected factors such as the frequency of forcing, wind gustiness coefficient and structural damping on the behaviour of structures.
Kopuły prętowe to obiekty inżynierskie charakteryzujące się dużymi rozmiarami przy stosunkowo niewielkich przekrojach elementów i jednocześnie dużej lekkości całej konstrukcji. Ustroje te, ze wzglądu na swoją małą sztywność, są wrażliwe na działanie czynników atmosferycznych, w szczególności wiatru. Obciążenie to charakteryzuje się dużą zmiennością, jest w znacznym stopniu czynnikiem losowym, co w sposób istotny utrudnia wykonywanie obliczeń. W przypadku projektowania takich obiektów, na podstawie geometrii obiektu, położenia i charakterystyki terenu przyjmuje się obciążenie w postaci parcia wiatru i na tej podstawie wykonuje obliczenia statyczne. W przypadku rozpatrywanych konstrukcji takie podejście nie zawsze wydaje się uzasadnione, niekiedy wskazane jest wykonywanie analiz dynamicznych. Nawet przy niewielkich siłach wymuszających, czasem trudno zauważalnych, istnieje niebezpieczeństwo wystąpienia zjawiska rezonansu, zarówno całej konstrukcji, jak i jej poszczególnych elementów. Obciążenie wiatrem może być przedstawione jako iloczyn statycznego parcia wiatru oraz funkcji zmieniającej tę wartość w czasie. W pracy przyjęto ją w postaci harmonicznej. Ze względu na brak rzeczywistych charakterystyk wiatrowych przyjęto dość szeroki zakres parametrów opisujących to obciążenie (częstość wymuszenia, współczynniki porywistości, prędkość bazowa).
Źródło:
Archives of Civil Engineering; 2016, 62, 1; 37-50
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement-based harmonic current modeling of mobile storage for power quality study in the distribution system
Autorzy:
Wenge, C.
Guo, H.
Roehrig, C.
Powiązania:
https://bibliotekanauki.pl/articles/140847.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrical vehicle
harmonic load modeling
harmonic measurement in power system
power quality
power system harmonics
Opis:
Electric vehicles (EVs) can be utilized as mobile storages in a power system. The use of battery chargers can cause current harmonics in the supplied AC system. In order to analyze the impact of different EVs with regardto their number and their emission of current harmonics, a generic harmonic current model of EV types was built and implemented in the power system simulation tool PSS®NETOMAC. Based on the measurement data for different types of EVs three standardized harmonic EV models were developed and parametrized. Further, the identified harmonic models are used by the computation of load flow in a modeled, German power distribution system. As a benchmark, a case scenario was studied regarding a high market penetration of EVs in the year 2030 for Germany. The impact of the EV charging on the power distribution system was analyzed and evaluated with valid power quality standards.
Źródło:
Archives of Electrical Engineering; 2017, 66, 4; 801-814
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of seepage on change in stress distribution scenario in static and seismic behaviour of earthen dams
Autorzy:
Nandi, N.
Roychowdhury, A.
Dutta, S. C.
Powiązania:
https://bibliotekanauki.pl/articles/266112.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
obciążenie harmoniczne
analiza elementów skończonych
kombinacja kwadratowa
complete quadratic combination method
harmonic load
finite element analysis
Opis:
The present study makes an effort to understand the damage of earthen dams under static and seismic loading condition. To make the investigation more realistic, behaviour of earthen dams considering the occurrence of a phreatic line indicating the submerged zone due to seepage within the dam body is considered. In case of earthen dams, homogeneous or nonhomogeneous, the consideration of the occurrence of a phreatic line or seepage line through the dam body is an important part of the earthen dam design methodology. The impervious material properties in the submerged zone below the phreatic line due to seepage may differ a lot in magnitudes as compared to the value of the same materials lying above this line. Hence, to have the exact stress distribution scenarios within the earthen dam, the different material properties above and below the phreatic line are considered in this present study. The study is first carried out by two-dimensional as well as three-dimensional finite element analysis under static loading condition. The work is further extended to observe the effect of seepage due to the consideration of the phreatic line on dynamic characteristics of earthen dams. Free vibration analysis and seismic analysis based on the Complete Quadratic Combination (CQC) method by considering twodimensional and three-dimensional modeling are carried out to present the frequencies, mode shapes and the stress distribution pattern of the earthen dam.
Źródło:
International Journal of Applied Mechanics and Engineering; 2018, 23, 1; 121-136
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Predictive regulation of the output voltage of a three-phase two-level voltage inverter with an LC filter
Autorzy:
Behrendt, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/135032.pdf
Data publikacji:
2019
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
uninterruptible power supply (UPS)
model predictive control (MPC)
predictive voltage regulator
load current prediction in the time domain
load current prediction in the frequency domain
total harmonic distortion (THD)
Opis:
The article has presented a predictive output voltage regulator of a three-phase two-level voltage inverter with an LC filter with a prediction of the receiver current in the time domain and the frequency domain. Simulations of the operation of the regulator were conducted for a three-phase receiver. The circuit model and simulations of the operation of the predictive voltage regulator were performed in the PSIM program. The algorithm of the predictive regulator was written in the C programming language in the Microsoft Visual Studio compiler and attached to the model performed in the PSIM program by a block that supports the Dynamic-Link Library.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2019, 57 (129); 79-87
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies