Wyszukujesz frazę "ground fault protection" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Frequency Response Testing of Zero-Sequence Current Transformers for Mining Ground Fault Protection Relays
Autorzy:
Kuliński, Krzysztof
Heyduk, Adam
Powiązania:
https://bibliotekanauki.pl/articles/1844476.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
zero-sequence current transformers
ground-fault protection relays
frequency response
Opis:
In Polish coal mining, medium voltage power distribution networks operate with an insulated neutral point. Zero-sequence current transformers are the basic sensors that generate input signals for earth-fault protection relays. In the literature, the problem of frequency response analysis of various types of current transformers has been examined many times, e.g. [1] [2], but not for zero-sequence current transformers so far. As part of the work, two types of zero-sequence current transformers in the range from 0.1 Hz to 100 kHz were tested. Both the change of the current ratio and the angular shift between the transformer secondary current and the total primary current were analyzed.
Źródło:
International Journal of Electronics and Telecommunications; 2020, 66, 4; 701--705
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sposób ochrony maszyn górniczych przed skutkami zwarć doziemnych w sieciach średniego napięcia
Method of a ground fault protection of mining machinery operating in MV network
Autorzy:
Miedziński, B.
Pyda, D.
Dzierżanowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/169739.pdf
Data publikacji:
2011
Wydawca:
Poltegor-Instytut Instytut Górnictwa Odkrywkowego
Tematy:
maszyna górnicza
ochrona ziemnozwarciowa
zwarcie doziemne
bezpieczeństwo w górnictwie
mining machines
ground fault protection
ground fault
safety in mining
Opis:
Niezawodna praca maszyn górniczych wymaga zapewnienia nie tylko odpowiednich, wymaganych warunków odnośnie do zasilania energią elektryczną, lecz również niezawodnej ochrony przed skutkami wszelkiego rodzaju awarii elektrycznych. Szczególnie istotna w tym przypadku jest skuteczna ochrona ziemnozwarciowa z uwagi na duże prawdopodobieństwo wystąpienia 1-fazowych zwarć doziemnych w sieciach średniego napięcia. W artykule przedstawiono i omówiono ideę wykorzystania charakterystycznych, wybranych cech harmonicznych parzystych w liniach zdrowych i uszkodzonych zasilanych z sieci średniego napięcia, do wykrywania 1-fazowych zwarć doziemnych.
Reliable operation of mining machinery requires stable and high quality electrical energy to supply as well as application of proper protection against any possible electrical disturbances. Particularly important is effective ground fault protection due to high probability of 1-phase fault occurrence in practice. In the paper is presented and discussed an idea of application of selected physical quantities of even current harmonics in faulty as well as healthy middle voltage feeders to detect and to clear ground faults.
Źródło:
Górnictwo Odkrywkowe; 2011, 52, 3-4; 55-57
0043-2075
Pojawia się w:
Górnictwo Odkrywkowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Warunki skuteczności kompensacji ziemnozwarciowej w sieciach SN o znacznej asymetrii doziemnej
Autorzy:
Lorenc, J.
Staszak, B.
Handke, J.
Powiązania:
https://bibliotekanauki.pl/articles/396974.pdf
Data publikacji:
2018
Wydawca:
ENERGA
Tematy:
asymetria doziemna
kompensacja ziemnozwarciowa
EAZ
to-ground unbalance
earth fault compensation
automatic protection systems
Opis:
Algorytmy działania urządzeń elektroenergetycznej automatyki zabezpieczeniowej i regulacyjnej w kompensowanych sieciach SN często muszą uwzględniać efekt doziemnej asymetrii naturalnej. Poziom takiej asymetrii określany jest przede wszystkim napięciem definiowanym różnicą potencjałów pomiędzy punktem neutralnym sieci a ziemią. Wartość tego napięcia ma znaczący wpływ na skuteczność działania zabezpieczeń ziemnozwarciowych oraz ogranicza często możliwości dokładnego strojenia cewek Petersena w procesie kompensacji ziemnozwarciowej. W artykule przedstawiono wyniki analiz warunków pracy sieci SN o znacznej asymetrii doziemnej. W praktyce eksploatacyjnej w sieciach terenowych o dużym udziale linii napowietrznych często stosowana jest metoda polegająca na zwiększaniu wartości współczynnika rozstrojenia kompensacji ziemnozwarciowej. Zdaniem autorów lepszym rozwiązaniem w tym zakresie jest stosowanie kompensacji dokładnej przy równoczesnym zwiększeniu współczynnika tłumienia. Pogarszając dobroć dławika, można zwiększyć współczynnik tłumienia nawet czterokrotnie w stosunku do jego naturalnej wartości. Za takim rozwiązaniem przemawia również efektywność dławika w gaszeniu zwarć łukowych.
Źródło:
Acta Energetica; 2018, 4; 88-92
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ground Fault Compensation Effectiveness Conditions in MV Grids with Significant To-Ground Unbalance
Autorzy:
Lorenc, J.
Staszak, B.
Handke, J.
Powiązania:
https://bibliotekanauki.pl/articles/397642.pdf
Data publikacji:
2018
Wydawca:
ENERGA
Tematy:
to-ground unbalance
earth fault compensation
automatic protection systems
asymetria doziemna
kompensacja ziemnozwarciowa
EAZ
Opis:
Operating algorithms of automatic power protection and regulation devices in compensated MV grids often must consider the effect of natural to-ground unbalance. The unbalance degree is determined primarily by the voltage defined by the difference between potentials of the grid’s neutral point and the ground. This voltage has a significant impact on the ground fault protection effectiveness and often limits the possibility of Petersen coils’ fine tuning in the ground fault compensation process. This paper presents results of an analysis of the operating conditions of an MV grid with a significant to-ground unbalance. In the practice of the operation of field grids with a large share of overhead lines, the method based on increasing the ground fault compensation detuning factor is often used. According to the authors, a better solution in this respect is the exact compensation while increasing the attenuation factor. By degrading the coil quality factor, the attenuation factor can be increased by up to four times of its natural value. This solution is also supported by the coil’s arc-suppression efficiency increase.
Źródło:
Acta Energetica; 2018, 4; 81-87
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quick-response protection system against electric shock in distributed generation systems
Autorzy:
Shkrabets, Fedir
Plaksin, Sergej
Ostapchuk, Oleksandr
Kuznetsov, Valeriy
Tymchenko, Irina
Muntian, Antonina
Powiązania:
https://bibliotekanauki.pl/articles/1840853.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
electric networks
protection
reliability
ground fault current
electrical safety
protection against electric shock
signal processing system
analog filtering
sieci elektryczne
ochrona
niezawodność
bezpieczeństwo elektryczne
ochrona przeciwporażeniowa
system przetwarzania sygnału
filtracja analogowa
Opis:
The peculiarities of the operation of distributed generation systems lead to a change in the requirements for the reliability and safety of the power distribution systems in which they are integrated. To meet the increased requirements, continuous monitoring of the insulation parameters (active resistance and capacitance to ground) is often used with operating artificial non-industrial frequency operational signals introduced into the network. In the case of a sudden touch, such a system is not effective, since the response time of the protection device, which consists of the signal processing time and the operating of the actuator, is crucially important. For the used operational signals with a frequency of 100 and 200 Hz, the processing time using the Fourier transform is 10 ms for 100 Hz and 5 ms for 200 Hz. Considering that the response time of the fastest actuators (based on vacuum switches) is from 3 to 7 ms, this is a rather significant period of time. To develop an effective resolver system, the capabilities of the Matlab environment were used to determine the most successful design of an analog prototype (Butterworth, Bessel, Chebyshev and Cauer of 6th order) for an operational signal with a frequency of 200 Hz. As a result, the processing time was established, which varies widely from 3.5 to 19 ms. Taking into account the known indicators, namely the frequency and number of operational signals, a signal processing system was developed using the vector-matrix analysis method. As a result of modeling the processing characteristics of functional signals (at a sampling rate of 1 kHz), the system quick-response was 3 ms, with the possibility of its further decrease as its productiveness increases.
Źródło:
Diagnostyka; 2021, 22, 3; 59-65
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quick-response protection system against electric shock in distributed generation systems
Autorzy:
Shkrabets, Fedir
Plaksin, Sergej
Ostapchuk, Oleksandr
Kuznetsov, Valeriy
Tymchenko, Irina
Muntian, Antonina
Powiązania:
https://bibliotekanauki.pl/articles/1840876.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
electric networks
protection
reliability
ground fault current
electrical safety
protection against electric shock
signal processing system
analog filtering
sieci elektryczne
ochrona
niezawodność
bezpieczeństwo elektryczne
ochrona przeciwporażeniowa
system przetwarzania sygnału
filtracja analogowa
Opis:
The peculiarities of the operation of distributed generation systems lead to a change in the requirements for the reliability and safety of the power distribution systems in which they are integrated. To meet the increased requirements, continuous monitoring of the insulation parameters (active resistance and capacitance to ground) is often used with operating artificial non-industrial frequency operational signals introduced into the network. In the case of a sudden touch, such a system is not effective, since the response time of the protection device, which consists of the signal processing time and the operating of the actuator, is crucially important. For the used operational signals with a frequency of 100 and 200 Hz, the processing time using the Fourier transform is 10 ms for 100 Hz and 5 ms for 200 Hz. Considering that the response time of the fastest actuators (based on vacuum switches) is from 3 to 7 ms, this is a rather significant period of time. To develop an effective resolver system, the capabilities of the Matlab environment were used to determine the most successful design of an analog prototype (Butterworth, Bessel, Chebyshev and Cauer of 6th order) for an operational signal with a frequency of 200 Hz. As a result, the processing time was established, which varies widely from 3.5 to 19 ms. Taking into account the known indicators, namely the frequency and number of operational signals, a signal processing system was developed using the vector-matrix analysis method. As a result of modeling the processing characteristics of functional signals (at a sampling rate of 1 kHz), the system quick-response was 3 ms, with the possibility of its further decrease as its productiveness increases.
Źródło:
Diagnostyka; 2021, 22, 3; 59-65
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies