Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "grid impedance" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Adjusting output impedance using a PI controller to improve the stability of a single-phase inverter under weak grid
Autorzy:
Jiao, J.
Nelms, R. M.
Powiązania:
https://bibliotekanauki.pl/articles/136224.pdf
Data publikacji:
2016
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
grid impedance
inverter output impedance
LC filter
PI controller
single-phase inverter
Opis:
Explored in this paper is the grid impedance effect on the stability of a single-phase grid connected inverter with an LC filter based on an analysis of the inverter output impedance. For a single-phase grid connected inverter, a PI controller is often used to regulate the current injected into the grid. However, the control performance can be influenced when the inverter is connected to a weak grid. Also, the utility grid has background harmonic noise, which can make the injected current distorted. Therefore, analysis of the output impedance of a single-phase grid connected inverter is important for the robustness and stability of the system. By modeling the output impedance of inverter, it can be determined that the proportional gain and integral gain of the controller have an effect on the output impedance. Analytical results show that by adjusting the PI controller parameters, the ability for harmonic reduction and stability of the system can be improved. Simulation and experiments using a 1 kW single-phase grid connected inverter verify the effectiveness of the theoretical analysis.
Źródło:
Transactions on Environment and Electrical Engineering; 2016, 1, 4; 50-57
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lokalna identyfikacja wartości impedancji zwarciowej węzła sieci wysokiego napięcia
Local identification of actual value of a power grid bus impedance
Autorzy:
Jędrychowski, R.
Kacejko, P.
Powiązania:
https://bibliotekanauki.pl/articles/157804.pdf
Data publikacji:
2005
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
identyfikacja wartości impedancji zwarciowej
węzeł sieci wysokiego napięcia
wysokie napięcie
actual value of a power grid
impedance
Opis:
Znajomość aktualnej wartości impedancji zwarciowej węzła sieci elektroenergetycznej oraz wartości pradów zwarciowych obliczanych na jej podstawie pozwala dostosować działanie urządzeń do aktualnych warunków pracy sieci. Prezentowana metoda wykorzystuje sygnały analogowe mierzone lokalnie do identyfikowania impedancji zwarciowej Zk w wybranym węźle sieci elektroenergetycznej; istota zastosowania sztucznych sieci neuronowych (ANN) polega na tym, że impedancja zwarciowa Zk łatwa do obliczenia jest wielkością trudną do określenia w sposób bezpośredni na podstawie pomiarów. W proponowanej metodzie zostaje ona ustalona przy wykorzystaniu "inteligencji" sieci neuronowej.
Adjustment of load to actual conditions of power grid operation requires a knowledge of an actual value of a power grid bus fault impedance of as well as of fault current values that can be calculated on that basis. The presented method uses locally measured analog signals to identify fault impedance Zk in a selected power gird bar. the essence of the ANN application consists in that the fault impedance Zk that is easy to calculate at the same time is difficult to determine in a direct way, on the basis of measurements. Within the proposed method it is the neural network "intelligence" that is used to determine the discussed quantity.
Źródło:
Pomiary Automatyka Kontrola; 2005, R. 51, nr 3, 3; 11-13
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on improving low-frequency oscillation characteristics of wind power grid-connected power system with doubly-fed wind generator based on virtual impedance power system stabilizer
Autorzy:
He, Ping
Zhu, Yongliang
Li, Qiuyan
Fan, Jiale
Tao, Yukun
Powiązania:
https://bibliotekanauki.pl/articles/27309939.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
doubly-fed induction wind turbine
grid-connected wind power
low frequency oscillation
power system stabilizer
virtual impedance
Opis:
The grid integration of large-scale wind power will alter the dynamic characteristics of the original system and the power distribution among synchronous machines. Meanwhile, the interaction between wind turbines and synchronous machines will affect the damping oscillation characteristics of the system. The additional damping control of traditional synchronous generators provides an important means for wind turbines to enhance the damping characteristics of the system. To improve the low frequency oscillation characteristics of wind power grid-connected power systems, this paper adds a parallel virtual impedance link to the traditional damping controller and designs a DFIG-PSS-VI controller. In the designed controller, the turbine active power difference is chosen as the input signal based on residual analysis, and the output signal is fed back to the reactive power control loop to obtain the rotor voltage quadrature component. With DigSILENT/PowerFactory, the influence of the controller parameters is analyzed. In addition, based on different tie-line transmission powers, the impact of the controller on the low-frequency oscillation characteristics of the power system is examined through utilizing the characteristic root and time domain simulation analysis.
Źródło:
Archives of Electrical Engineering; 2023, 72, 3; 811--826
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies