Tytuł:
The Formation of Gaseous Atmosphere in a Molten Cast Iron/MouldingSand Contact System
Autorzy:
Mocek, J.
Powiązania:
https://bibliotekanauki.pl/articles/382409.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
moulding sand
cast iron melt
gas in metal
mould atmosphere
masa formierska
żeliwo
Opis:
Drops of molten cast iron were placed on moulding sand substrates. The composition of the forming gaseous atmosphere was examined. It was found that as a result of the cast iron contact with water vapour released from the sand, a significant amount of hydrogen was evolved. In all the examined moulding sands, including sands without carbon, a large amount of CO was formed. The source of carbon monoxide was carbon present in cast iron. In the case of bentonite moulding sand with sea coal and sand bonded with furan resin, in the composition of the gases, the trace amounts of hydrocarbons, i.e. benzene, toluene, styrene and naphthalene (BTX), appeared. As the formed studies indicate much higher content of BTX at lower temperature it was concluded that the hydrocarbons are unstable in contact with molten iron.
Źródło:
Archives of Foundry Engineering; 2014, 14, 1; 79-84
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical Strength of MV Ship-switchgear During Fault Arc
Wytrzymałość mechaniczna okrętowych rozdzielnic średniego napięcia podczas zwarć łukowych
Autorzy:
Partyka, R.
Kowalak, D.
Powiązania:
https://bibliotekanauki.pl/articles/397187.pdf
Data publikacji:
2015
Wydawca:
ENERGA
Tematy:
metal enclosed switchgear
fault arc
gas pressure
gas temperature
mechanical stresses in enclosures
rozdzielnice osłonięte
łuk zwarciowy
ciśnienie gazów
temperatura gazów
Opis:
In this paper the analysis of pressure stressed in an enclosure during fault arc inside switchgear is also presented. There is introduced the method based on determining stresses which are the sum of tensile stresses (membrane) and deflection stresses. For tensile stresses analysis the energy method, for unrestrainedly supported rectangular plate, was used. Further in the paper, the calculations and measurements results of enclosure stresses were shown. Dimensions of analyzed enclosure were 0.48 x 0.52. Also, an oscillogram record from laboratory tests was given further in the paper. There were demonstrated the results of calculations of maximum stresses σysum in an enclosure an analyzed cable compartment of marine switchgear during fault arc. In the presented paper the calculation method of pressure and temperature of gases inside MV marine switchgear during fault arc was presented. Simultaneous equation (1) gives a thermodynamic model of processes concurrent to fault arcs inside air insulated switchgear. Simultaneous equation (1) enables calculation of pressure p and temperature T based on average arc power PL. The above mentioned model is particularly useful for analysis of pressure and temperature in switchgears equipped with slots or overpressure reducing canals. Calculated, according to (1), temperature is the average temperature in the area encompassed by the fault arc. Formulating it more strictly; that area is defined by the product of volume V and coefficient c. The method does not count a spatiotemporal distributions of temperature and pressure in the total volume of the compartment.
W artykule przedstawiono analizę naprężeń w elementach osłonowych rozdzielnic z izolacją powietrzną, poddanych działaniu ciśnienia gazów podczas wewnętrznych zwarć łukowych. Zaproponowano metodę opartą na wyznaczeniu naprężeń będących sumą naprężeń rozciągających (błonowych) i naprężeń zginających. Do analizy naprężeń rozciągających zastosowano metodę energetyczną dla płyt prostokątnych swobodnie podpartych. Przedstawiono też metodę obliczania ciśnienia i temperatury gazów wewnątrz rozdzielnicy okrętowej średniego napięcia podczas zwarcia łukowego. Układ równań (1) przedstawia model termodynamiczny procesów towarzyszących zwarciom łukowym wewnątrz rozdzielnic i umożliwia obliczanie ciśnienia p oraz temperatury T na podstawie średniej mocy łuku PL. Model ten jest szczególnie przydatny do analizy ciśnienia i temperatury w rozdzielnicach wyposażonych w szczeliny lub kanały wypływowe. Obliczona wg równań (1) temperatura jest średnią temperaturą w obszarze objętym zwarciem łukowym, a ściślej w obszarze definiowanym przez iloczyn objętości V i współczynnika c. Metoda nie uwzględnia rozkładu przestrzenno-czasowego temperatury i ciśnienia w całej objętości przedziału. W dalszej części artykułu przedstawiono wyniki obliczeń oraz pomiarów naprężeń w osłonie o wymiarach 0,48 x 0,52 m, jak również – oscylogram z prób laboratoryjnych. Podano wyniki obliczeń maksymalnych naprężeń σysum w osłonie analizowanego przedziału kablowego rozdzielnicy okrętowej podczas zwarcia łukowego.
Źródło:
Acta Energetica; 2015, 1; 98-107
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies