Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "gas detection" wg kryterium: Temat


Tytuł:
Remotely measuring the hydrogen gas by using portable Raman lidar system
Autorzy:
Choi, In Young
Baik, Sung Hoon
Choi, Young Soo
Powiązania:
https://bibliotekanauki.pl/articles/1835765.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
Raman lidar
photon counter
hydrogen gas
remote gas detection
Opis:
A Raman lidar system is able to detect the range of gas distribution and measure the hydrogen gas concentration remotely. This paper discusses the development of a photon counting Raman lidar system for remotely measuring the hydrogen gas concentration. To verify the developed photon counting Raman lidar system, experiments were carried out in outdoor conditions. As the results indicate, the developed photon counting Raman lidar system is possible to measure 0.66 to 100 vol% hydrogen gas concentrations at a distance of 30 m. In addition, the measuring average error measured 0.54% and the standard deviation is 2.42% at a distance of 30 m.
Źródło:
Optica Applicata; 2021, 51, 1; 37-49
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Infrared imaging fourier transform spectrometer as the stand-off gas detection system
Autorzy:
Kastek, M.
Piątkowski, T.
Trzaskawka, P.
Powiązania:
https://bibliotekanauki.pl/articles/220556.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gas detection
hyperspectral detection
imaging Fourier-transform spectrometer
stand-off detection
Opis:
The article presents the detection of gases using an infrared imaging Fourier-transform spectrometer (IFTS). The Telops company has developed the IFTS instrument HyperCam, which is offered as a short- or long-wave infrared device. The principle of HyperCam operation and methodology of gas detection has been shown in the paper, as well as theoretical evaluation of gas detection possibility. Calculations of the optical path between the IFTS device, cloud of gases and background have been also discussed. The variation of a signal reaching the IFTS caused by the presence of a gas has been calculated and compared with the reference signal obtained without the presence of a gas in IFTS's field of view. Verification of the theoretical result has been made by laboratory measurements. Some results of the detection of various types of gases has been also included in the paper.
Źródło:
Metrology and Measurement Systems; 2011, 18, 4; 607-620
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination Of Gas Mixture Components Using Fluctuation Enhanced Sensing And The LS-SVM Regression Algorithm
Autorzy:
Lentka, Ł.
Smulko, J. M.
Ionescu, R.
Granqvist, C. G.
Kish, L. B.
Powiązania:
https://bibliotekanauki.pl/articles/221708.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
LS-SVM algorithm
resistance gas sensor
fluctuation enhanced sensing
gas detection
Opis:
This paper analyses the effectiveness of determining gas concentrations by using a prototype WO3 resistive gas sensor together with fluctuation enhanced sensing. We have earlier demonstrated that this method can determine the composition of a gas mixture by using only a single sensor. In the present study, we apply Least-Squares Support-Vector-Machine-based (LS-SVM-based) nonlinear regression to determine the gas concentration of each constituent in a mixture. We confirmed that the accuracy of the estimated gas concentration could be significantly improved by applying temperature change and ultraviolet irradiation of the WO3 layer. Fluctuation-enhanced sensing allowed us to predict the concentration of both component gases.
Źródło:
Metrology and Measurement Systems; 2015, 22, 3; 341-350
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Portable exhaled breath analyzer employing fluctuation-enhanced gas sensing method in resistive gas sensors
Autorzy:
Kwiatkowski, A.
Chludziński, T.
Smulko, J.
Powiązania:
https://bibliotekanauki.pl/articles/220591.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
resistance gas sensor
fluctuation enhanced sensing
flicker noise
gas detection
breath sample collection
Opis:
This paper presents a portable exhaled breath analyser, developed to detect selected diseases. The set-up employs resistive gas sensors: commercial MEMS sensors and prototype gas sensors made of WO3 gas sensing layers doped with various metal ingredients. The set-up can modulate the gas sensors by applying UV light to induce physical changes of the gas sensing layers. The sensors are placed in a tiny gas chamber of a volume of about 22 ml. Breath samples can be either injected or blown into the gas chamber when an additional pump is used to select the last breath phase. DC resistance and resistance fluctuations of selected sensors using separate channels are recorded by an external data acquisition board. Low-noise amplifiers with a selected gain were used together with a necessary bias circuit. The set-up monitors other atmospheric parameters interacting with the responses of resistive gas sensors (humidity, temperature, atmospheric pressure). The recorded data may be further analysed to determine optimal detection methods.
Źródło:
Metrology and Measurement Systems; 2018, 25, 3; 551-560
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of ammonia leak in laboratory conditions using a FLIR 306 camera and a portable gas detector
Autorzy:
Lisowska-Lis, Agnieszka
Siudut, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/93176.pdf
Data publikacji:
2020
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Tarnowie
Tematy:
thermal imaging
infrared
gas detection
ammonia
obrazowanie termiczne
podczerwień
wykrywanie gazu
amoniak
Opis:
The study aimed to analyse detection methods of ammonia leakage by various electrical methods. Rapid detection of the escape of hazardous technical gases is extremely important in large chemical plants. The basis of the research was the use of a specialized camera, model FLIR GF306, to detect a leak of selected gases in a narrow infrared band. In laboratory conditions, the controlled emission of gaseous ammonia at various concentrations was simulated and gas detection was performed: a) using a narrow infrared thermography method, b) by a portable electrochemical detector dedicated to detecting ammonia. The turbulent flow of gas into the environment and high thermal contrast between the expanding gas and the background are the conditions for effective gas detection with a thermal imaging camera operating in a narrow infrared band.
Źródło:
Science, Technology and Innovation; 2020, 8, 1; 35-41
2544-9125
Pojawia się w:
Science, Technology and Innovation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sensitive detection of acetylene by second derivative spectra with tunable diode laser absorption spectroscopy
Autorzy:
Deng, H.
Sun, J.
Li, P.
Liu, Y.
Yu, B.
Li, J.
Powiązania:
https://bibliotekanauki.pl/articles/174963.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
tunable diode laser absorption spectroscopy
TDLAS
signal processing
Savitzky–Golay filter
trace gas detection
Opis:
A tunable diode laser absorption spectrometer was developed for trace acetylene gas analysis, the system performance was evaluated by combing an appropriate digital signal processing methods, i.e., Savitzky–Golay smoothing and differentiation algorithm. The calculation of the derivative spectra by this method is accompanied by simultaneous data smoothing. Based on the 2nd deriv- ative spectra detection method, the Allan variance technique indicates a C2H2 detection limit of 1.7ppm for 1-s averaging time, and a minimum noise level of 62ppb (parts per billion), at the optimum integration time of ~60s. The calculated 2nd derivative spectra with better resolution, lower detection limits, save signal processing time, and improve the ability to distinguish unresolved spectral signals.
Źródło:
Optica Applicata; 2016, 46, 3; 353-363
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optoelektroniczne metody detekcji gazów
Optoelectronic gas detections methods
Autorzy:
Bielecki, Z.
Wojtas, J.
Brudnowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/210551.pdf
Data publikacji:
2006
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
detekcja gazów
urządzenia optoelektroniczne
czujniki optoelektroniczne
pomiar stężenia gazu
gas detection
optoelectronic devices
opotelectronic sensors
gas concentration measurement
Opis:
W artykule omówiono optoelektroniczne metody wykrywania gazów. Szczególną uwagę zwrócono na technikę CRDS (ang. Cavity Ring Down Spectroscopy), którą zastosowano do detekcji NO₂. Czułość tej metody umożliwia pomiary śladowych ilości gazu, nawet o koncentracji rzędu kilku ppb. W pracy przeprowadzono analizy teoretyczne dotyczące wpływu wybranych czynników konstrukcyjnych na czułość metody CRDS. Opracowano unikatowe stanowisko badawcze, w którym zastosowano wnękę optyczną wyposażoną w zwierciadła sferyczne o dużym współczynniku odbicia, półprzewodnikowy laser impulsowy (414 nm) oraz fotopowielacz współpracujący ze wzmacniaczem fazoczułym i z oscyloskopem cyfrowym.
The paper presents optoelectronic methods of gas detection. Particular attention was given to Cavity Ring-Down Spectroscopy (CRDS) technique with blue laser diodes-based system for nitrogen dioxide (NO₂) detection. The sensitivity of this method allows to measure trace level of gas concetrations, even at ppb level. Theoretical analyses concerning influance of selected factors on sensitivity of CRDS method were conducted. A unique experimental setup was constructed. The setup includs the resonance optical cavity, which is equipped with spherical and high reflectance mirrors, the pulsed diode laser (414 nm) and photomultliplier wihch is connected to the digital oscilloscope and the lock-in.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2006, 55, 2; 37-51
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Surface acoustic waves application for gas leakage detection
Zastosowanie akustycznych fal powierzchniowych do detekcji wycieku gazów
Autorzy:
Pasternak, Mateusz
Jasek, Krzysztof
Grabka, Michał
Powiązania:
https://bibliotekanauki.pl/articles/327742.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
surface acoustic waves
gas detection
diagnostic of sealing
akustyczne fale powierzchniowe
detekcja gazów
diagnostyka uszczelnień
Opis:
Surface Acoustic Waves (SAW) are by their nature very sensitive to changes in physical propagation conditions. This statement relates primarily to the properties of the substrate, i.e. the surface on which these waves propagate, but under certain conditions it also refers to the parameters of the gaseous environment directly in contact with the substrate. The influence of this environment on SAW parameters can be used to detect specific gases that are present in this environment and change its density. The basic research problem was to determine the dependence of the resonant frequency and attenuation of waves in a resonator with SAW on the parameters and concentrations of specific gases in the gaseous environment in which the resonator works. The secondary objective was to determine whether this dependence is strong enough to be used for the construction of sensors and whether it is possible to identify gases present in the environment based on such measurements. Two-port resonators from SAW and measuring stand of our own design were used for the research. The analyses conducted and laboratory measurements confirmed the existence of the abovedescribed dependence. It was found that it increases with the increase of the difference between the molar mass of the gas being tested and the average molecular mass of the gaseous environment. This fact makes the proposed method suitable for detection of gases of relatively low or high molar masses. In air it is possible to detect hydrogen, helium, krypton, xenon and vapour of volatile compounds with sufficiently high molar masses.
Akustyczne fale powierzchniowe (AFP) są ze swej natury bardzo czułe na zmiany fizycznych warunków propagacji. Stwierdzenie to dotyczy przede wszystkim własności ich podłoża tj. powierzchni, po której te fale się propagują, jednak w pewnych warunkach odnosi się ono także do parametrów otoczenia gazowego bezpośrednio stykającego się z tym podłożem. Wpływ tego otoczenia na parametry AFP można wykorzystać do detekcji specyficznych gazów znajdujących się w tymże otoczeniu i zmieniających jego gęstość. Podstawowym problemem badawczym było określenie zależności częstotliwości rezonansowej i tłumienia fal w rezonatorze z AFP od parametrów i stężeń określonych gazów znajdujących się w otoczeniu gazowym, w którym tenże rezonator pracuje. Ustalono też czy zależność ta jest dostatecznie silna aby dało ją się wykorzystać do budowy czujników oraz czy możliwa jest na podstawie takich pomiarów identyfikacja gazów obecnych w otoczeniu. Do badań wykorzystano dwuportowe rezonatory z AFP oraz własnej konstrukcji stanowisko pomiarowe. Stwierdzono, że wymieniona zależność rośnie w miarę wzrostu różnicy masy molowej oznaczanego gazu od przeciętnej masy cząsteczkowej otoczenia gazowego. Fakt ten powoduje, że proponowana metoda nadaje się w do detekcji gazów o stosunkowo niskich lub wysokich masach molowych. W powietrzu można w ten sposób wykrywać wodór, hel, krypton, ksenon oraz pary lotnych związków o odpowiednio wysokiej masie molowej.
Źródło:
Diagnostyka; 2020, 21, 1; 35-39
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda analizy i oceny ryzyka potencjalnych zdarzeń zagrażających w projektowaniu systemu detekcji gazów wybuchowych w obiektach przemysłowych
Method of analysis and risk assessment of potential incidents in the designing system detection of explosive gases in industrial facilities
Autorzy:
Rogala, I.
Kosmowski, K. T.
Powiązania:
https://bibliotekanauki.pl/articles/267675.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ryzyko
wybuch
detekcja
niezawodność
bezpieczeństwo funkcjonalne
ATEX
risk of explosion
gas detection
reliability
functional safety
Opis:
W celu zmniejszenia ryzyka związanego z potencjalnym wybuchem gazów tworzących atmosferę wybuchową stosuje się systemy detekcji gazów. Ich zadaniem jest wykrycie zagrożenia i odpowiednia reakcja w celu zredukowania ryzyka np. przez poprzez odpowiednie ostrzeżenie i uruchomienie odpowiedniej wentylacji. Systemy te powinny spełniać standardy przemysłowe, a w określonych warunkach powinny być zaprojektowane zgodnie z wymogami bezpieczeństwa funkcjonalnego. W ramach analizy i oceny ryzyka związanego z zagrożeniem wybuchu można uzyskać istotną poprawę stanu bezpieczeństwa poprzez właściwy dobór systemów detekcji gazów wybuchowych, posługując się odpowiednią metodyką. W artykule zostanie przedstawiony przykład analizy ryzyka i doboru urządzeń systemu detekcji gazów, z uwzględnieniem określenia wymaganego poziomu SIL i weryfikacji tego poziomu dla przykładowego systemu detekcji.
Reducing risks associated with potential explosion of explosive gases may be achieved by using gas detection systems. Their task is to detect hazards to enable appropriate operator or system response in order to reduce the risk eg. through appropriate warning and ventilation. These systems must meet industry standards, and under certain conditions they should be designed in accordance with the requirements of functional safety. Through analysis and risk assessment of explosion risk it can be achieved a significant improvement in the field of safety through the proper selection of explosive gas detection systems, using the appropriate methodology. The article is an example of risk analysis and equipment selection of gas detection system, including determining the required SIL and verification that level for given detection system.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 51; 163-166
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method of selecting the LS-SVM algorithm parameters in gas detection process
Sposób doboru parametrów algorytmu LS-SVM w procesie detekcji gazów
Autorzy:
Lentka, Ł.
Smulko, J.
Powiązania:
https://bibliotekanauki.pl/articles/267849.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
gas detection
optimal parameters selection
support vector machine (SVM)
artificial immune system
detekcja gazów
optymalny dobór parametrów
maszyna wektorów nośnych
sztuczny system immunologiczny
Opis:
In this paper we showed the method of resistive gas sensors data processing. The UV irradiation and temperature modulation was applied to improve gas sensors’ selectivity and sensitivity. Noise voltage across the sensor’s terminals (proportional to its resistance fluctuations) was recorded to estimate power spectral density. This function was an input data vector for LS-SVM (least squares – support vector machine) algorithm, which predicted a concentration of gas present in sensor’s ambient atmosphere. The algorithm creates a non-linear regression model at learning stage. This model can be used to predict gas concentration by recording resistance noise only. We have proposed a fast method of selecting LS-SVM parameters to determine high quality model. The method utilizes a behavior of immune system to determine optimal parameters of the LS-SVM algorithm. High accuracy of the applied method was proved for the recorded experimental data.
W artykule pokazano metodę przetwarzania danych z rezystancyjnych czujników gazów, stosowaną do wykrywania gazów. W celu zwiększenia czułości i selektywności czujników zastosowano modulację temperaturową oraz oświetlenie diodą LED UV aby zebrać więcej danych. Szumy napięciowe rejestrowane na zaciskach czujnika (proporcjonalne do fluktuacji jego rezystancji) zostały wykorzystane do wyznaczenia gęstości widmowej mocy. Ta funkcja stanowiła wektor danych wejściowych dla algorytmu maszyny wektorów nośnych według kryterium najmniejszych kwadratów (LS-SVM), umożliwiając określenie stężenia gazu występującego w atmosferze otaczającej czujnik. Nieliniowy charakter algorytmu pozwala na tworzenie w fazie uczenia modelu na podstawie danych uzyskanych z pomiarów za pomocą metody odniesienia. Pokazano szybki sposób doboru optymalnych parametrów algorytmu LS-SVM, gwarantujących skuteczność szacowania stężenia gazu. W badaniach wykorzystano metodę symulującą działanie systemu odpornościowego. Analiza danych eksperymentalnych potwierdziła skuteczność prezentowanej metody.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 46; 69-72
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection, Identification, and Quantification of SF6 Point-Source Emissions Using Hyper-Cam LW Airborne Platform
Wykrywanie, identyfikacja i kwantyfikacja punktowych źródeł emisji SF6 z użyciem Hyper-Cam LW zainstalowanego na platformie powietrznej
Autorzy:
Kastek, Mariusz
Firmanty, Krzysztof
Saute, Benjamin
Gagnon, Jean-Philippe
Lariviere-Bastien, Martin
Pawelski, Daniel
Powiązania:
https://bibliotekanauki.pl/articles/2068621.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
hyperspectral imaging
gas detection
quantification
spectral imaging
thermal imaging
infrared
stand-off
remote sensing
obrazowanie hiperspektralne
detekcja gazu
kwantyfikacja
obrazowanie spektralne
obrazowanie termiczne
podczerwień
zdalna detekcja
Opis:
Detection, identification, and quantification of greenhouse gases is essential to ensure compliance with regulatory guidelines and mitigate damage associated with anthropogenic climate change. Passive infrared hyperspectral imaging technology is among the solutions that can detect, identify and quantify multiple greenhouse gases simultaneously. The Telops Hyper-Cam Airborne Platform is an established system for aerial thermal infrared hyperspectral measurements for gas survey applications. In support of the Hypercam, is developing a suite of hyperspectral imaging data processing algorithms that allow for gas detection, identification, and quantification in real-time. In the Fall of 2020, the Hyper-Cam-LW Airborne platform was flown above a validated SF6 gas release system to collect hyperspectral data for gas quantification analysis. This measurement campaign was performed to document performance of the Hyper-Cam gas quantification capabilities against known quantities of released gas.
Wykrywanie, identyfikacja i kwantyfikacja gazów cieplarnianych jest niezbędna do zapewnienia zgodności z wytycznymi regulacyjnymi i złagodzenia szkód związanych z antropogenicznymi zmianami klimatu. Technologia pasywnego obrazowania hiperspektralnego w podczerwieni należy do rozwiązań, które mogą wykrywać, identyfikować i kwantyfikować wiele gazów cieplarnianych jednocześnie. Platforma lotnicza Telops Hyper-Cam jest uznanym systemem do lotniczych pomiarów hiperspektralnych w termicznej podczerwieni do zastosowań związanych z badaniem gazów. W ramach wsparcia dla Hypercam, opracowywany jest zestaw algorytmów przetwarzania danych obrazowania hiperspektralnego, które pozwalają na wykrywanie, identyfikację i kwantyfikację gazów w czasie rzeczywistym. Jesienią 2020 r. platforma Hyper-Cam-LW Airborne została umieszczona nad zatwierdzonym systemem uwalniania gazu SF6 w celu zebrania danych hiperspektralnych do analizy kwantyfikacji gazu. Ta kampania pomiarowa została przeprowadzona w celu udokumentowania wydajności możliwości kwantyfikacji gazu Hyper-Cam w odniesieniu do znanych ilości uwolnionego gazu.
Źródło:
Pomiary Automatyka Robotyka; 2021, 25, 3; 37--41
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Seismic modelling as a tool for optimization of downhole microseismic monitoring array
Autorzy:
Pasternacki, A.
Święch, E.
Maćkowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/184420.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
gas accumulation
shale formation
detection
Opis:
Hydraulic fracturing processes employed to release natural gas accumulations trapped in shale formation causes cracks in fractured media occurred as microseismic events. Those events can be detected with either surface or downhole monitoring technique. One of the advantages of downhole microseismic monitoring technique is the relative high detection moment magnitude threshold, compared to surface and quasi surface arrays (Maxwell 2014). The epicenters of detected microseismic events are located with certain accuracies (Eisner et al. 2010). The uncertainties in location are mainly caused by simplification of a very complex geological structure, geometry of the monitoring network, arrival time pick uncertainty and naturally selected processing method. The correct assessment of macroseismic events locations with their uncertainties is the key to proper interpretation of the results. In this study, authors present an analysis of optimizing geometry of the downhole microseismic monitoring array minimalizing location error and taking into account level of detectability. To achieve this goal, several different downhole array geometries were tested. The study is located in Northern Poland where active exploration of shale gas deposits takes place. In the investigated area three wells are located, one vertical (W-1) and two horizontal, which have been drilled in the same azimuths but different direction and slightly different depths (W3H – deeper and W2Hbis – shallower). As there is possibility that these wells will be stimulated in close period of time, the chosen array placed in the monitoring well should be optimal for depths. As Eisner stated in his work, best downhole array should have to consist of 3C sensors placed below and above of the planed depths of stimulation to reduce uncertainty of the event locations (Eisner et al. 2009). Both treatment wells have relatively high horizontal distance, which results with high distance between receivers and possible events (in ranges between 500 m to 1700 m), which is quite high compared to literature examples (Warpiński & Natl 1994). To perform this analysis, GeoTomo MiVu TM Microseismic Processing System was used, which includes a Vecon modeling engine. This software has been granted to AGH UST for research and educational purposes. The passive seismic modelling was done with GRTM method (generalized reflection transmission coefficients) (Kennet 1980). This kind of mixed procedure is relatively fast to perform and allows checking many different configurations of downhole array. Based on the 3D seismic survey provided by PGNiG in the investigated area authors have decided to use simple layered velocity model which sufficiently describes the local geological conditions. The synthetic microseismic events were located using TGS (Traveltime Grid Search) algorithm available in MiVu software. Based on presented analysis authors were able to choose optimal geometry of downhole micro seismic array for both prospective intervals which fulfill condition of being good compromise between costs and location accuracy of possible events.
Źródło:
Geology, Geophysics and Environment; 2016, 42, 1; 112-113
2299-8004
2353-0790
Pojawia się w:
Geology, Geophysics and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A study on optimization of sample preparation for gas chromatographic methods used in routine irradiated foodstuffs detection
Autorzy:
Virgolici, M.
Medvedovici, A. V.
Manea, M. M.
Cutrubinis, M.
Moise, I. V.
Georgescu, R.
Powiązania:
https://bibliotekanauki.pl/articles/148092.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
irradiated foodstuffs detection
gas chromatography
Opis:
The study is focused on the optimization and minimization of sample preparation procedures given in EN 1784 and EN 1785 standardized methods for the detection of irradiated foodstuffs which contain fats. The techniques used in this study were gas chromatography (GC) with a flame ionization detector (FID) for hydrocarbons (HC) detection and GC coupled with mass spectrometry (MS) for 2-alkylcyclobutanones detection. Our work revealed that alternative extraction and clean-up procedures as well as alternative injection modes like large volume injection can significantly reduce the total analysis time and costs with comparable results.
Źródło:
Nukleonika; 2009, 54, 2; 115-121
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Natychmiastowa detekcja nielegalnego poboru gazu u odbiorców ze zdemontowanym gazomierzem
Immediate detection of illegal gas consumption at consumers with a disassembled gas meter
Autorzy:
Łach, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/2143401.pdf
Data publikacji:
2021
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
nierozliczone ilości gazu
nielegalny pobór gazu
kradzież gazu
detekcja nielegalnego poboru gazu
unaccounted-for gas lost
illegal gas consumption
gas theft
detection of illegal gas consumption
Opis:
Jednym ze źródeł nierozliczonych ilości gazu w sieci dystrybucyjnej są kradzieże gazu. Najczęściej do tego typu procederu dochodzi poprzez ingerencję w gazomierz u odbiorcy indywidualnego. Operatorzy, starając się minimalizować straty gazu, prowadzą ciągłą kontrolę urządzeń pomiarowych, mającą na celu wychwycenie nieautoryzowanych ingerencji. W przypadku wykrycia nieprawidłowo- ści gazomierz może zostać skierowany na badanie metrologiczne lub/i mechanoskopijne w akredytowanym do tego celu laboratorium, którego zadaniem, jako niezależnej strony trzeciej, jest określenie stopnia ingerencji oraz wyznaczenie błędu wskazań gazomierza. Pozwala to operatorowi sieci na oszacowanie poniesionych strat oraz wystosowanie konkretnych roszczeń w stosunku do konsumenta. Kolejnym źródłem strat przedsiębiorstwa gazowniczego mogą być kradzieże gazu z całkowitym pominięciem układów pomiarowych. Może do nich dochodzić np. po rozwiązaniu umowy z konsumentem lub nawet przed jej zawarciem. W takich przypadkach kontrola punktów pomiarowych jest szczególnie trudna, a dochodzenie należności z tytułu nielegalnego poboru gazu łatwe do zakwestionowania ze względu na brak możliwości wyznaczenia ilości pobranego gazu. Sytuację pogarsza fakt negatywnego wpływu tego typu połączeń na bezpieczeństwo działania sieci gazowej. W ramach prac badawczych prowadzonych w INiG – PIB podjęto próbę opracowania urządzenia umożliwiającego detekcję nielegalnego poboru gazu z pominięciem gazomierza. W artykule przedstawiono zagrożenia oraz skutki prawne, jakie niesie ze sobą nielegalny pobór gazu z pominięciem gazomierza, w szczególności gdy proceder jest realizowany za pomocą np. dętki. Następnie omówiono, jakie wymagania powinno spełniać urządzenie, które pozwoliłoby ograniczyć problem nielegalnego poboru gazu u odbiorców ze zdemontowanym gazomierzem. W dalszej części artykułu omówiono technologię spełniającą wskazane założenia oraz zaprezentowano rysunek koncepcyjny urządzenia. W efekcie przedstawiono sposób wykonania pierwszej wersji prototypu oraz potwierdzono poprawność jego działania. Opisana na łamach artykułu druga wersja prototypu posłużyła do zgłoszenia wynalazku do Urzędu Patentowego Rzeczypospolitej Polskiej.
One of the sources of unaccounted-for gas in the distribution network is gas theft. Most thefts occur by gas residential consumers tampering with gas meters. In an attempt to minimize losses, operators conduct a constant control of metering equipment in order to detect unauthorized interference. If any irregularities are detected, the gas meter can be sent for metrological and/or mechanoscopic examination in a laboratory accredited for that purpose. Its task, as an independent third party, is to determine the degree of interference and determine the error in the gas meter readings. This allows the gas network operator to estimate the losses incurred and to make specific claims against the consumer. Another source of losses for the gas company may be thefts of gas involving total bypassing of metering systems. This may occur e.g. after the termination of a contract with a consumer or even before its conclusion. In such cases, control of metering points is particularly difficult, and the recovery of amounts due to illegal gas consumption may be easily questioned due to the impossibility of determining the volumes of gas taken. The situation is exacerbated by the fact that such connections have a negative impact on the operational security of the gas network. As part of research work conducted at the Oil and Gas Institute – National Research Institute, an attempt was made to develop a device that would enable the detection of illegal gas consumption bypassing the gas meter. The article presents the risks and legal consequences of such an illegal gas consumption, in particular when carried out by means of, for example, an inner tube. Then the article discusses what requirements should be met by a device that would reduce the problem of illegal gas consumption by consumers with a dismantled gas meter. Further in the article, the technology the indicated assumptions is demonstrated and a conceptual drawing of the device is presented. As a result, the method of constructing the first version of the prototype was presented and the correctness of its operation was confirmed. The second version of the prototype, described in the article, was used to file and application for the invention at the Patent Office of the Republic of Poland.
Źródło:
Nafta-Gaz; 2021, 77, 12; 805-811
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przegląd metod wykrywania nieszczelności sieci gazowych
An overview of methods for detecting gas network leaks
Autorzy:
Holewa-Rataj, J.
Kukulska-Zając, E.
Powiązania:
https://bibliotekanauki.pl/articles/1835320.pdf
Data publikacji:
2017
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
gazociągi
sieci gazowe
wykrywanie nieszczelności
gas pipelines
gas networks
leakage detection
Opis:
Wycieki gazu ziemnego z sieci przesyłowej i dystrybucyjnej są poważnym zagrożeniem dla środowiska ze względu na emisję metanu do atmosfery. Niniejszy artykuł stanowi przegląd dostępnych i stosowanych metod wykrywania nieszczelności gazociągów. Opisano w nim metody techniczne, nietechniczne oraz obliczeniowe, szczególnie zwracając uwagę na możliwość wykorzystania tych metod podczas prowadzenia pomiarów wielkości emisji metanu.
Gas leaks from natural gas transmission and distribution networks are a serious threat to the environment due to the emission of methane into the atmosphere. This article reviews the available and used gas leak detection methods. It also describes the available technical, non-technical and calculation methods including the possible use of these methods when conducting measurements of methane emissions.
Źródło:
Nafta-Gaz; 2017, 73, 11; 871-877
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies