Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "frequency stability" wg kryterium: Temat


Tytuł:
Laser frequency stability estimation and velocity measurement in the atmosphere with self-heterodyne
Autorzy:
Zhang, H.
Wang, H.
Zhao, S.
Powiązania:
https://bibliotekanauki.pl/articles/174066.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
frequency stability
atmospheric propagation
self-heterodyne
Doppler velocity
Opis:
We present a novel method of self-heterodyne for laser frequency stability estimation in the atmosphere. At the same time, it is used in the Doppler velocity measurement for moving targets in the atmosphere. The transmission range is 16.2 km (round-trip propagation with 8.1 km) in the horizontal atmospheric path, and the measuring results showed that the frequency stability of the whole laser detection system is 53.4 kHz with 20.7 kHz stand deviation. This frequency stability is the integrated influence with the whole detection system not just for the laser, but it can be considered as the estimation of the laser’s frequency stability. It is much more practical for the heterodyne detection in the atmosphere. At last, the method of self-heterodyne was used for 16.2 km round trip velocity measurement. It is showed that the velocity absolute error is less than 1.5 cm/s in the turbulent atmosphere, and the relative error is not higher than 5%.
Źródło:
Optica Applicata; 2016, 46, 2; 305-316
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
HVDC auxiliary emergency power control strategy for power disturbance in two different positions of AC/DC interconnection system
Autorzy:
Li, Congshan
He, Ping
Wang, Youyi
Ji, Yuyi
Yang, Cunxiang
Powiązania:
https://bibliotekanauki.pl/articles/141502.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
unbalanced power
emergency control
power angle stability
frequency stability
control logic
Opis:
High voltage direct current (HVDC) emergency control can significantly improve the transient stability of an AC/DC interconnected power grid, and is an important measure to reduce the amount of generator and load shedding when the system fails. For the AC/DC interconnected power grid, according to the location of failure, disturbances can be classified into two categories: 1) interconnected system tie-line faults, which will cause the power unbalance at both ends of the AC system, as a result of the generator rotor acceleration at the sending-end grid and the generator rotor deceleration at the receiving-end grid; 2) AC system internal faults, due to the isolation effect of the DC system, only the rotor of the generator in the disturbed area changes, which has little impact on the other end of the grid. In view of the above two different locations of disturbance, auxiliary power and frequency combination control as well as a switch strategy, are proposed in this paper. A four-machine two-area transmission system and a multi-machine AC/DC parallel transmission system were built on the PSCAD platform. The simulation results verify the effectiveness of the proposed control strategy.
Źródło:
Archives of Electrical Engineering; 2019, 68, 2; 245-263
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new optical frequency transfer method via fibre based on active phase noise compensation with single acousto-optic modulator
Autorzy:
Wang, Guoyong
Yao, Yuanbo
Yan, Tao
Bian, Lang
Meng, Yansong
Powiązania:
https://bibliotekanauki.pl/articles/221592.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acousto-optic modulator
optical frequency transfer over fibre
phase noise compensation
relative frequency stability
Opis:
In this paper, we propose and experimentally demonstrate a new method for optical frequency transfer over fibre. Instead of dual acousto-optic modulators (AOMs) as adopted in the traditional fibre phase noise compensation setup, here an active fibre phase noise compensation scheme with a single acousto-optic modulator (AOM) is used. The configuration simplifies the equipment of the user end while maintaining a high-performance optical frequency transfer stability. We demonstrate an actively stabilized coherent transfer at an optical frequency of 193.55THz over 10-km spooled fibre, obtaining a relative frequency stability (Allan deviation) of 3.84 x 10-16/1 s and 4.08 x 10-18/104 s, which is improved by about 2~3 orders of magnitude in comparison with the one without any phase noise compensation that achieves a relative frequency stability of 1.81 x 10-14/1 s and 2.48 x 10-15/104 s.
Źródło:
Metrology and Measurement Systems; 2019, 26, 1; 115-124
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The conception of the use of multi-level inverters in the shipping shaft generator systems of high power
Koncepcja wykorzystania falowników wielopoziomowych w układach z okrętową prądnicą wałową dużej mocy
Autorzy:
Tarnapowicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/360407.pdf
Data publikacji:
2010
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
prądnica wałowa
stabilizacja częstotliwości
falownik wielopoziomowy
shaft generator
stability of frequency
multilevel inverter
Opis:
The fundamental problem of using the shaft generators of high power in the shipping systems is bound up with the stability of frequency. Electronic systems used nowadays are based on the thyristor inverters which entails vices of such solutions. The article presents the conception of the use of multi-level inverters built on the basis of fully controllable valves (transistors IGBT).This solution eliminates the defects of thyristor inverters.
Zasadniczy problem stosowania w systemach okrętowych prądnic wałowych dużej mocy związany jest ze stabilizacją częstotliwości. Stosowane obecnie układy energoelektroniczne opierają się na wykorzystaniu falowników tyrystorowych, które implikują wady takich rozwiązań. W artykule przedstawiono koncepcję wykorzystania falowników wielopoziomowych, zbudowanych w oparciu o zawory w pełni sterowalne (tranzystory IGBT), które pozbawione są wad falowników tyrystorowych.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2010, 22 (94); 67-70
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Źródła czasu i częstotliwości. Kluczowe parametry
Time and Frequency Standards. Key Parameters
Autorzy:
Masiukiewicz, Antoni
Powiązania:
https://bibliotekanauki.pl/articles/509367.pdf
Data publikacji:
2018
Wydawca:
Akademia Finansów i Biznesu Vistula
Tematy:
stałość częstotliwości
wzorce czasu i częstotliwości
wzorce atomowe
wzorce kwarcowe
stability of frequency
time and frequency standards
atomic clocks
quartz crystal oscillators
Opis:
W artykule przedstawiono najważniejsze parametry wzorców czasu i częstotliwości oraz omówiono właściwości eksploatacyjne wzorców w zależności od technologii ich wykonania. Porównano parametry różnych wzorców ze szczególnym uwzględnieniem stałości częstotliwości. Przedstawiono postęp w stałości wzorców częstotliwości na przykładzie NIST.
The article presents the most important parameters of time and frequency standards, and discusses their features depending on the technology of their production. We compared the performance of different standards with particular emphasis on frequency stability. The progress in standards frequency stability is shown on the example of NIST.
Źródło:
Zeszyty Naukowe Uczelni Vistula; 2018, 59(2) Informatyka; 72-87
2353-2688
Pojawia się w:
Zeszyty Naukowe Uczelni Vistula
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multicomponent ceramic materials on the basis of PZT for the production of piezoelectric resonators
Autorzy:
Bochenek, D.
Surowiak, Z.
Gavrilyachenko, S. V.
Kupriyanov, M. F.
Powiązania:
https://bibliotekanauki.pl/articles/176898.pdf
Data publikacji:
2005
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
PZT
piezoelectric transducers
resonance frequency
thermal stability
Opis:
Investigations on the influence of the PbTiO3 content on the crystalline and domain structure of PZT-based four-component solid solutions have been performed. It has been shown that there is a close relation between the structure and temperature stability of the resonance frequency (fr) of the fabricated piezoceramic transducers. Better and more stable results have been obtained by doping and modifying the basic chemical composition obtaining Pb(Zr1-x Tix)O3. The compositions with minimal Δ fr / fr, within the temperature range T = 213–358 K (in relation to room temperature Tr = 293 K), exhibited (i) the smallest internal friction (Q-1m), (ii) the highest mechanical quality (Qm), (iii) high values of spontaneous deformation of the elementary cell (δT and δRe), (iv) the complex a-c-domain structure in the tetragonal phase (T) and the simple domain structure in the rhombohedral phase (Re). The practical result of the present work was the fabrication of piezoceramic electric band filters exhibiting Δ fr / fr < 0.2% and a high mechanical quality factor (Qm = 3225).
Źródło:
Archives of Acoustics; 2005, 30, 1; 87-107
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Importance of seismic wave frequency in FEM-based dynamic stress and displacement calculations of the earth slope
Autorzy:
Fuławka, Krzysztof
Kwietniak, Anna
Lay, Vera
Jaśkiewicz-Proć, Izabela
Powiązania:
https://bibliotekanauki.pl/articles/2073762.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
slope stability
numerical analysis
seismic load
frequency analysis
Opis:
Reliable assessment of earthen dams' stability and tailing storage facilities widely used in the mining industry is challenging, particularly under seismic load conditions. In this paper, we propose to take into account the effect of the dominant frequency of seismic load on the stability assessment of tailing/earthen dams. The calculations are performed by finite element modelling (FEM) with the Mohr–Coulomb failure criteria. To separate the frequency content from other dynamic parameters describing the seismic wave, synthetic waveforms with identical amplitude and attenuation characteristics, but differing spectral characteristics have been used. The analysis has been performed for three different slope angles and two scenarios of seismic wave propagation. Consequently, the changes of total displacement and shear stresses depending on the frequencies have been determined and clearly show that lower frequencies cause higher stress levels and displacement. Finally, the response surface methodology has been applied to determine how different parameters affect the slope stability under dynamic load conditions. Overall, this study is a first step to improve the existing methods to assess slope stability when considering seismic load.
Źródło:
Studia Geotechnica et Mechanica; 2022, 44, 1; 82--96
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of energy-efficient IBC with IGBT module for photovoltaic applications
Autorzy:
Kumar, C. Prasanna
Rao, Anand
Powiązania:
https://bibliotekanauki.pl/articles/1193903.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
interleaved boost converter
efficiency
stability
power converter
switching frequency
Opis:
The proposed study is improvised value-engineered modifications for the basic interleaved boost converter (IBC) by including relevant modifications in circuits, which is expected for a better performance in switching with reduction in losses. The newly modified IBC circuit with insulated gate bipolar transistor (IGBT) along with converter has been experimented by simulations and the results are tabulated to modified IBC with metal oxide silicon field effect transistors. Further experimental analysis and validations of the proposed simulation with hardware developed adopting model SKM195GB066D consisting of IGBTs is presented. This study further enhances and summarises the optimum utilisation and the performance of IBC with the proposed IGBT modules that synchronises power diode. Enhancing the simulation outcomes, the hardware is proposed and developed to be tested for a load up to 1.5 kW with the evaluation of key parameters such as efficiency of the converter.
Źródło:
Power Electronics and Drives; 2020, 5, 40; 73-81
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczenie odchylenia względnego częstotliwości oraz niestabilności częstotliwości wzorców
Measurement of fractional frequency difference and frequency stability calculation
Autorzy:
Gadomska, A.
Górecki, M.
Powiązania:
https://bibliotekanauki.pl/articles/209179.pdf
Data publikacji:
2008
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
czas
częstotliwość
niestabilność
odchylenie Allana
time
frequency
stability
Allan deviation
Opis:
Praca prezentuje metodę pomiaru odchylenia względnego częstotliwości (o.w.cz.) oraz wyznaczania niestabilności częstotliwości (odchylenie Allana) wzorców częstotliwości za pomocą komparatora fazy i częstotliwości w połączeniu z częstościomierzem cyfrowym. Dane pomiarowe zbierane są automatycznie i przeliczane przy pomocy arkuszy kalkulacyjnych oraz specjalistycznego oprogramowania do analizy danych w dziedzinie częstotliwości Stable 32. W pracy zawarto również analizę źródeł niepewności występujących przy pomiarach częstotliwości oraz opisano sposób wyznaczania poprawki związanej z prognozą o.w.cz. wzorca odniesienia.
This paper presents a method of fractional frequency difference measurement and frequency stability (Allan deviation) calculation of frequency standards with frequency and phase comparator in connection with a frequency counter. Measurement data are collected automatically and calculated with calculation sheets or with special purpose software Stable 32 for time- and frequency-domain data analysis. This paper presents also the sources of uncertainties that occur during frequency measurement and reveals the method of reference standard accuracy prognosis calculation.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2008, 57, 2; 367-376
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic stability of a stepped drillstring conveying drilling fluid
Autorzy:
Zhao, G.-H.
Tang, S.
Liang, Z.
Li, J.
Powiązania:
https://bibliotekanauki.pl/articles/280899.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
drill string
stepped fluid-conveying pipe
complex frequency
stability
FEM
Opis:
Taking into account differences between a drill pipe (DP) and a drill collar (DC), the drillstring in a vertical well is modeled as a stepped pipe conveying a drilling fluid downwards to the bottom inside the string and then upwards to the ground from the annulus. An analytical model that describes lateral vibration of the drillstring and involves the drillstring gravity, weight on bit (WOB), hydrodynamic force and damping force of the drilling fluid is established. By analysis of complex frequencies, the influences of WOB, borehole diameter, DP length, velocity and density of the drilling fluid on the stability of the system are discussed.
Źródło:
Journal of Theoretical and Applied Mechanics; 2017, 55, 4; 1409-1422
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie synchronicznej pętli fazowej (PLL) w przetwornikach pomiarowych
Autorzy:
Sidor, T.
Powiązania:
https://bibliotekanauki.pl/articles/156439.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
phase lock loop
PLL stability
phase detection
frequency demodulation
homodyne amplifier
Opis:
Układy Synchronicznej Pętli Fazowej (SPF lub PLL - Phase Lock Loop) są powszechnie stosowane we współczesnych urządzeniach telekomunikacyjnych do synchronizacji, powielania i detekcji częstotliwości. Wynika to w naturalny sposób z genezy ich powstania. Idea PLL powstała bowiem już w latach trzydziestych ubiegłego wieku jako pewna metoda odbioru i detekcji sygnałów radiowych [1]. Nie zyskała jednak dużej popularności ze względu na trudności techniczne przy stosowanej wówczas technice układów elektronicznych. Dopiero od momentu kiedy pojawiły się układy scalone zawierające wszystkie podzespoły pętli w jednym chipie zaczęto powszechnie je stosować, gdyż posiadają bardzo ciekawe własności i stwarzają rozliczne możliwości ich wykorzystywania. Układy PLL mogą też służyć do budowy elementów różnych elektronicznych przetworników pomiarowych, zastępując z powodzeniem istniejące inne rozwiązania układowe, a także, ze względu na swoje unikalne własności stwarzają duże pole do inwencji w tej dziedzinie. Jednak wiedza na ich temat nie jest powszechna w środowisku metrologów i m.in. z tego powodu podstawy działania układów PLL zostaną szerzej omówione we wstępie.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 1, 1; 18-21
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The magnitude optimum design of the PI controller for plants with complex roots and dead time
Autorzy:
Cvejn, Jan
Powiązania:
https://bibliotekanauki.pl/articles/2106500.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
dead time
frequency response
magnitude optimum
PID controller
process control
stability margin
Opis:
Analytical design of the PID-type controllers for linear plants based on the magnitude optimum criterion usually results in very good control quality and can be applied directly for high-order linear models with dead time, without need of any model reduction. This paper brings an analysis of properties of this tuning method in the case of the PI controller, which shows that it guarantees closed-loop stability and a large stability margin for stable linear plants without zeros, although there are limitations in the case of oscillating plants. In spite of the fact that the magnitude optimum criterion prescribes the closed-loop response only for low frequencies and the stability margin requirements are not explicitly included in the design objective, it reveals that proper open-loop behavior in the middle and high frequency ranges, decisive for the closed-loop stability and robustness, is ensured automatically for the considered class of linear systems if all damping ratios corresponding to poles of the plant transfer function without the dead-time term are sufficiently high.
Źródło:
Archives of Control Sciences; 2022, 32, 1; 5--35
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Generalized feedback stability for periodic linear time-varying, discrete-time systems
Autorzy:
Orłowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/201050.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
discrete-time systems
time-varying systems
non-stationary systems
feedback stability
frequency analysis
Opis:
The paper proposes a novel method for feedback stability evaluation for linear time-varying, discrete-time control systems. It is assumed that the time-varying system can be described by the general discrete-time, time-varying state space model and by the equivalent linear input-output (transfer) operator. The method extends feedback stability concepts for systems given in a general linear time-varying, discrete-time form, not only in the Lurie form. In the paper selected short-time stability concepts are employed for inference about feedback stability of systems defined on an infinite time-horizon. Theoretical considerations are complemented by numerical examples.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2012, 60, 1; 171-178
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of control parameters on synchronization stability of virtual synchronous generator
Autorzy:
Zhang, Yanxia
Cheng, Yachao
Liu, Kaixiang
Han, Yue
Powiązania:
https://bibliotekanauki.pl/articles/2172794.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
control parameter
frequency modulation coefficient
phase plane method
synchronization stability
virtual synchronous generator
Opis:
Different from the synchronization mechanism of synchronous generators, the non-synchronous generators must be synchronized with the grid through a controller. Generally, the virtual synchronous generator (VSG) control strategy is adopted for this purpose. In view of the current situation, where the control loops are not comprehensively considered in the research of the synchronization stability of the VSG, this paper considers multiple control loops, such as active frequency loops, virtual governors, power filters and current constraint control, to establish the mathematical model of the VSG and infinite system. On this basis, the correlation formula between power angle difference and control parameters is deduced. Adopting the phase plane method, the influence of different control loops and their parameters on the transient synchronization stability is analyzed. Finally, a setting principle of the frequency modulation coefficient of virtual governors is proposed, which not only meets the response speed of control systems, but also has good control performance.
Źródło:
Archives of Electrical Engineering; 2022, 71, 4; 811--828
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Damping low-frequency oscillations in a multi-machine power system using a fuzzy-multi-band power system stabilizer
Autorzy:
Essallah, Sirine
Khedher, Adel
Powiązania:
https://bibliotekanauki.pl/articles/41178019.pdf
Data publikacji:
2022
Wydawca:
Politechnika Warszawska, Instytut Techniki Cieplnej
Tematy:
power system stability
low-frequency oscillations
Fuzzy-MB-PSS
stabilność systemu elektroenergetycznego
niska częstotliwość
oscylacje
Opis:
Synchronous generators are usually eguipped with power system stabilizers (PSS) to damp low-freguency oscillations. Among the various types of PSS, it has recently been demonstrated that the Multi-Band PSS (MB-PSS) has a better performance to handle all global, inter-area and local modes. However, the performance of this PSS may degrade since the power supply system is intrinsically non-linear and its operating conditions freguently change. This paper introduces a new design of MB-PSS based on Mamdani Fuzzy inference (Fuzzy-MB-PSS). Compared to the IEEE standard MB-PSS, the proposed stabilizer is more efficient owing to its ability to deal with oscillations at different operating points. The controller is tested on a power system benchmark under various disturbance conditions to prove its robustness and to demonstrate its superiority over conventional PSS and MB-PSS.
Źródło:
Journal of Power Technologies; 2022, 102, 4; 140-148
1425-1353
Pojawia się w:
Journal of Power Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies